Remote Automation Solutions Bristol ACCOL II Owner's manual

  • Hello! I am an AI chatbot trained to assist you with the Remote Automation Solutions Bristol ACCOL II Owner's manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
www.EmersonProcess.com/Bristol
Reference Manual
D4044
May 2006
ACCOL II Software
ACCOL II Reference Manual
For use with DPC 3330, DPC 3335, RTU 3305, RTU 3310, and
3530-xx series units
BLANK PAGE
SECTION 2 – ODD HEADER
5/2006
i
Getting Additional Information
In addition to the information contained in this manual, you may receive additional assistance in
using this product from the following sources:
Help Files / Release Notes
Many Bristol software products incorporate help screens. In addition, the software typically
includes a ‘read me’ release notes file detailing new features in the product, as well as other
information which was available too late for inclusion in the manual.
Contacting Bristol Directly
The address for our world headquarters is:
Bristol, Inc.
a division of Emerson Process Management
1100 Buckingham Street
Watertown, Connecticut 06795 USA
Our main phone numbers are:
(860) 945-2200
(860) 945-2213 (FAX)
Regular office hours are Monday through Friday, 8:00AM to 4:30PM Eastern Time, excluding
holidays, and scheduled factory shutdowns. During other hours, callers may leave messages
using Bristol's voice mail system.
Telephone / E-Mail Support - Technical Questions
During regular business hours, Bristol's Application Support Group can provide telephone/e-mail
support for your technical questions.
SECTION 2 – EVEN HEADER
5/2006
ii
Please refer to the table, below, for a list of products, and their associated technical support
contact information:
Product Support Phone
Number(s):
E-Mail Address:
ControlWave series (hardware and
software)
(860) 945-2394
(860) 945-2286
Network 3000 hardware except for
TeleFlow series
(860) 945-2502 [email protected]
TeleFlow series (3530-xx)
(860) 945-8604. [email protected]
ACCOL, Open BSI, UOI, all other
software except for ControlWave and
OE.
(860) 945-2286 [email protected]
OpenEnterprise (OE) software
(860) 945-3865 [email protected]
Radio telemetry services (interfacing
Bristol hardware to radios)
(407) 629-9463
(407) 629-9464.
Non-Technical Questions, Product Orders, etc.
Questions of a non-technical nature (product orders, literature requests, price and delivery
information, etc.) should be directed to the nearest Bristol sales office or to your Bristol-
authorized sales representative. Please call the main Bristol number (860-945-2200) or visit our
web site, listed below, if you are unsure which office covers your particular area.
Visit our Site on the World Wide Web
For general information about Bristol, Inc. and its products, please visit our site on the World
Wide Web at: www.EmersonProcess.com/Bristol
Training Courses
Bristol's Training Department offers a wide variety of courses in Bristol hardware and software
at our Watertown, Connecticut headquarters, and at selected Bristol regional offices, throughout
the year. Contact our Training Department at (860) 945-2343 for course information, enrollment,
pricing, and schedules.
Who Should Read This Manual?
This manual is intended to be used by a System Engineer, or other
individual, who will be using the ACCOL II language to program a Bristol
Network 3000-series controller.
It assumes familiarity with the following subjects.
• Use of personal computers.
• Use of ACCOL Workbench software. See the ACCOL Workbench User
Manual (document# D4051) for details. Also see An Introduction to
ACCOL (document# D4056).
BLANK PAGE
Contents
What's New in ACCOL?.............................................................................. ix
Hardware and Software Requirements .....................................................xv
Summary of ACCOL II Structures..........................................................xxix
AAT ....................................................................................................... AAT-1
Abort ...................................................................................................Abort-1
AGA3 ................................................................................................. AGA3-1
AGA3Dens ................................................................................. AGA3Dens-1
AGA3Iter ..................................................................................... AGA3Iter-1
AGA3TERM ..............................................................................AGA3Term-1
AGA5 ................................................................................................. AGA5-1
AGA7 ................................................................................................. AGA7-1
AGA8 ................................................................................................. AGA8-1
AGA8Detail ............................................................................. AGA8Detail-1
AGA8Gross ............................................................................... AGA8Gross-1
ANIN/RANIN .................................................................................... ANIN-1
ANOUT/RANOUT ......................................................................... ANOUT-1
ARC_STORE ......................................................................... ARC_STORE-1
ATOOLS.INI (for DOS-based ACCOL Tools) .............................. ATOOLS-1
AUDIT/EAUDIT ................................................................................ Audit-1
Auto-Dial Modem Interface ........................................................ Auto-Dial-1
Averager ....................................................................................... Averager-1
BBTI Modules (GBBTI, LBBTI)........................................................ BBTI-1
Break ................................................................................................. Break-1
Buffers ............................................................................................. Buffers-1
Calculator ................................................................................... Calculator-1
Characterize ........................................................................... Characterize-1
Command ................................................................................... Command-1
Comment ..................................................................................... Comment-1
Communication Ports ................................................................Commport-1
Comparator ............................................................................. Comparator-1
Control Statements .............................................................. Control Stmts-1
Counter Modules.......................................................................... Counters-1
Custom ........................................................................................... Custom-1
Daccumulator ....................................................................... Daccumulator-1
Data Arrays ............................................................................. Data Arrays-1
Demux/EDemux .............................................................................. Demux-1
Differentiator ....................................................................... Differentiator-1
Digin/RDigin....................................................................................... Digin-1
ACCOL II Reference Manual
Page v
Digout/RDigout ................................................................................ Digout-1
Downloading...........................................................................Downloading-1
EAStatus ..................................................................................... EAStatus-1
EIntegrator ..............................................................................EIntegrator-1
Encode ............................................................................................. Encode-1
Error Reporting .....................................................................Error Report-1
ETOT/TRND ......................................................................... ETOT/TRND-1
EVP.......................................................................................................EVP-1
Expanded Node Addressing.............................................. Expanded Node-1
FOR/ENDFOR .................................................................................... FOR-1
Formats ......................................................................................... Formats-1
FPV....................................................................................................... FPV-1
Function ....................................................................................... Function-1
GOTO ............................................................................................... GOTO-1
GPA8173 ....................................................................................... GPA8173-1
GSV....................................................................................................... GSV-1
HCBO ............................................................................................... HCBO-1
HILOLIMITER ................................................................. HILOLIMITER-1
HILOSELECT ..................................................................... HILOSELECT-1
HSANIN ....................................................................................... HSANIN-1
HWSTI.............................................................................................HWSTI-1
IF/ENDIF/ELSE/ELSEIF....................................................................... IF-1
Integrator ................................................................................... Integrator-1
Internet_Protocol .......................................................................... Internet-1
IP_Client ..................................................................................... IP_Client-1
IP Client / Server Communications ................................... IPClient/Servr-1
IP Node Addressing ........................................................................ IPAddr-1
IP_Server ....................................................................................IP_Server-1
ISO5167 ......................................................................................... ISO5167-1
Keyboard ..................................................................................... Keyboard-1
LCBO ................................................................................................. LCBO-1
Lead/Lag.......................................................................................Lead/Lag-1
Liquid_Density ................................................................... Liquid_Density-1
Liquid Measurement Guidelines ..................................... Liquid_Measure-1
LLANIN/RLLANIN ..................................................................... LLANIN-1
Logger............................................................................................... Logger-1
Master/EMaster .............................................................................. Master-1
Master/Slave Communications............................................. Master/Slave-1
Mux/EMux .......................................................................................... MUX-1
Node Addressing .............................................................. Node Addressing1
Nodestatus ............................................................................... Nodestatus-1
PDM/RPDM.........................................................................................PDM-1
PDO/RPDO.......................................................................................... PDO-1
ACCOL II Reference Manual
Page vi
PID3TERM...............................................................................PID3TERM-1
Portstatus ................................................................................... Portstatus-1
Process I/O ............................................................................... Process I/O-1
Questionable Data Bit ...............................................................Ques Data-1
RBE ..................................................................................................... RBE-1
Redundancy .............................................................................Redundancy-1
Redundancy Concepts ............................................................... Redundcon-1
Resume ........................................................................................... Resume-1
RIOSTATS ................................................................................. RIOSTATS-1
Scheduler.....................................................................................Scheduler-1
Sequencer ................................................................................... Sequencer-1
Signals ............................................................................................. Signals-1
Signal Lists...............................................................................Signal Lists-1
Slave ................................................................................................... Slave-1
Smart .................................................................................................Smart-1
Stepper ........................................................................................... Stepper-1
Storage ........................................................................................... Storage-1
Suspend ......................................................................................... Suspend-1
System ............................................................................................. System-1
System Signals ................................................................... System Signals-1
System0 ......................................................................................... System0-1
SYS_3530.....................................................................................SYS_3530-1
Task ..................................................................................................... Task-1
TCheck ........................................................................................... TCheck-1
Timer ................................................................................................. Timer-1
TOT/TRND ............................................................................... TOT/TRND-1
Vlimiter ......................................................................................... Vlimiter-1
VMux ................................................................................................ VMUX-1
WAIT DELAY ............................................................................ Wait Delay-1
WAIT DI/RWAIT DI ..................................................................... WAIT DI-1
WAIT FOR................................................................................. WAIT FOR-1
WAIT TIME.............................................................................WAIT TIME-1
Watchdog ..................................................................................... Watchdog-1
XMTR_Interface...............................................................XMTR_Interface-1
Index
ACCOL II Reference Manual
Page vii
BLANK PAGE
What’s New in ACCOL?
ACCOL II Reference Manual
Page ix
New Features
New EAUDIT Modes for Protected Mode Users
Users with 386EX Protected Mode PLS/PLX/PES/PEX 04.43 (or newer) firmware
now have new Modes for the EAUDIT Module, that allow the module to start and
stop logging under user control.
Communication Enhancements Added for 186-level firmware
Certain communication enhancements such as dial-up-ack, and immediate response
delay, which had been included for other platforms, have now been extended to 186-
based versions of the DPC 3330, DPC 3335, and RTU 3310. Users require AM.20 (or
newer) firmware and ACCOL Workbench Version 8.3 (or newer) to take advantage
of these enhancements.
Support for New High Density High Speed Counter Board
Protected Mode controllers now support the High Density High Speed Counter
Board, allowing up to 8 high speed counter channels. This requires Protected Mode
PLS/PLX/PES/PEX 04.40 (or newer) firmware. See the ‘Process I/O’ section for
details.
Encode Module Enhancements
The Encode Module now incorporates two new functions (9 and 10). Function 9
takes the elements in a column of a logical array (or logical values from a signal
list) and converts them into the equivalent binary integer. Function 10 takes a
binary integer and converts it to logical values in a signal list or logical data array.
To use these new functions, you must have TeleFlow / TeleRTU firmware TFA01.28
/ TRA01.28 (or newer) firmware or Protected Mode PLS/PLX/PES/PEX 04.40 (or
newer) firmware. See the ‘Encode’ section for details.
ISO5167 Module Enhancements
The ISO5167 Module has been enhanced to support an additional method for
calculating the flow rate for orifice plates. The new method uses equations from the
1998 edition of the ISO5167 standard. This revision is available in Protected Mode
controllers with PLS/PLX/PES/PEX 04.40 or newer firmware. See the ‘ISO5167’
section for details.
What’s New in ACCOL?
ACCOL II Reference Manual
Page x
New System Signal - #ONLBAT..
Beginning with Protected Mode firmware PLS/PLX/PES/PEX 04.40, a new system
signal has been created to allow the user to prevent the on-line RAM backup
battery diagnostics from being performed. See the ‘System Signals’ section for
details.
Portstatus Module Changes
The Portstatus Module has been changed to support on-line changes in the mode
between Enron Modbus Slave and Gould Modbus Slave. NOTE: These changes
require TeleFlow/TeleRTU TFA/TFR 01.28 firmware, or Protected Mode
PLS/PLX/PES/PEX 04.40 firmware with PCP/PCE 04.40 custom firmware. For
details on these changes, see the ‘Portstatus’ section, and the ACCOL II Custom
Protocols Manual (document# D4066).
What’s New in ACCOL?
1
NOTE: The PLS or PES firmware can execute in a controller with the NPX, but the NPX
hardware will NOT be used. The PLX or PEX firmware CANNOT execute in a controller that does
NOT include the numeric NPX hardware.
ACCOL II Reference Manual
Page xi
ACCOL Firmware/ACCOL Tools Versions
ACCOL firmware may be purchased for several different platforms. Not all features
are common to all firmware versions. Which version is appropriate depends upon
the Network 3000 controller platform being used.
Firmware Version: Platforms Used With: Recommended revision of
ACCOL Workbench for
full compatiblity.
PLS04.43/PLX04.43
PLS is the standard
firmware; PLX is
required to make use of
the numeric co-processor
(NPX) hardware.
1
386EX Protected Mode
CPU versions of:
DPC 3330
DPC 3335
RTU 3310
Use ACCOL Workbench
8.3 (or newer)
PES04.43/PEX04.43
PES is the standard
firmware; PEX is
required to make use of
the numeric co-processor
(NPX) hardware.
1
386EX Protected Mode
CPU with Ethernet board
versions of:
DPC 3330
DPC 3335
Use ACCOL Workbench
8.3 (or newer)
RMS04.12 386EX Real Mode CPU
versions of:
DPC 3330
DPC 3335
RTU 3310
Use ACCOL Workbench
7.1 (or newer)
AM.20 186-based CPU versions
of:
DPC 3330
DPC 3335
RTU 3310
Use ACCOL Workbench
8.3 (or newer)
What’s New in ACCOL?
Firmware Version: Platforms Used With: Recommended revision of
ACCOL Workbench for
full compatiblity.
ACCOL II Reference Manual
Page xii
LS502.2 RTU 3305 Use ACCOL Workbench
8.0 (or newer)
TFA01.30 EGM 3530-10B TeleFlow,
EGM 3530-20B TeleFlow
Plus
Use ACCOL Workbench
8.3 (or newer)
TRA01.30 RTU 3530-15B TeleRTU
RTU 3530-25B TeleRTU
Plus
Use ACCOL Workbench
8.3 (or newer)
Notes About Using Older DOS-based ACCOL
Tools:
For support purposes, the ACCOL II Reference Manual includes many references
which are specific to DOS-based tools (AIC, Toolkit, Taskspy, ABC, REV, ACLINK
etc.) Although still available, development on these tools has been frozen at version
5.13, and no additional enhancements or releases are contemplated. These tools are
INCOMPATIBLE WITH ALL PROTECTED MODE FIRMWARE, AND ALL
VERSIONS OF TeleFlow/TeleRTU FIRMWARE. IN ADDITION, THERE ARE
LIMITS ON DOS-TOOL COMPATIBILITY WITH RTU 3305 FIRMWARE
REVISIONS HIGHER THAN LS500.
Users with other platforms (GFC 3308 as well as 186 and 386EX Real Mode
versions of the DPC 3330, DPC 3335, and RTU 3310) can still use the DOS-based
tools to create ACCOL loads, however, any features newer than ACCOL Version
5.13 will NOT be available.
All users with newer firmware are strongly urged to upgrade to ACCOL Workbench.
Optional Comm Port NOT Available in Protected Mode
The Optional Communication Port (TANO) is NOT available in 386EX Protected
Mode units. Support still exists in 186-based units, and in 386EX Real Mode units.
What’s New in ACCOL?
ACCOL II Reference Manual
Page xiii
No Synchronous Communication or Remote I/O (RIO) Support
for RTU 3310 with 386EX or for any 386EX unit without the
Enhanced Communication Board
RTU 3310 controllers with the 386EX CPU engine board, as well as any other
386EX unit which does not have an enhanced communication board, DO NOT
support synchronous communication. RIOR ports will not function, because of this
lack of synchronous communication capability. See the ’Communication Ports’
section for details.
Flash Program For Installing Field Upgrades of System
Firmware (For units with FLASH support ONLY)
To install field upgrades of system or custom protocol firmware, a copy of the Flash
Program FLASH.EXE is required. This program is available on diskette, together
with the Master Flash File FLASH.MST and the binary system (*.BIN) files needed
for various controller platforms. Information regarding the installation/use of this
program is included in a text file on the diskette containing the FLASH program.
BLANK PAGE
Hardware and Software Requirements
ACCOL II Reference Manual
Page xv
This chart shows the minimum ACCOL software tools and firmware revisions
necessary to use a particular ACCOL module or structure on a particular hardware
platform. For example, to use the AGA3 Module with a 186-based DPC 3330
requires ACCOL Tools version 4.0 (or newer) and S (or newer) level firmware.
Unless otherwise noted, modules available in a particular software or firmware
revision remain available in all subsequent revisions.
A check mark ’ ’ in the column for the 3350/3380/3385 indicates that a module or
structure is compatible, and has existed since before ACCOL tools version 4.2 and S
firmware.
All ACCOL Tools versions above Version 6.0 refer to ACCOL Workbench software.
A filling a particular table cell indicates that the module or structure is NOT
supported for this platform.
ACCOL Module
or Structure
3350 /
3380 /
3385
(See
Note 1)
3310,
3330,
3335
with 186
CPU
(See
Note 2)
3310,
3330,
3335
with
386EX
Real
Mode
CPU
(See Note
3)
3310,
3330,
3335
with
386EX
Protected
Mode
CPU
(See Note
4
)
3308-
10A,
3308-
30A,
3308-
10B,
3308-
30B,
3308-50B
(See Note 5)
3305
(See Note
11)
3530-10B,
3530-20B,
3530-15B,
3530-25B
(See Note
12)
AAT 8.01
PLS04.30
8.01
TFA01.26/TRA01.26
ABORT 4.0
S
5.10
RMS00
6.0
PLS00
5.4
A.01
5.13
LS500
ACCOL Workbench
(RM) 1.1
TFA01/TRA01
AGA3
4.0
S
5.10
RMS00
6.0
PLS00
ACCOL Workbench
(RM) 1.1
TFA01/TRA01
AGA3Dens 6.3
PLS03
AGA3ITER 5.7
AH
5.10
RMS00
6.0
PLS00
5.7
C.01
5.13
LS500
ACCOL Workbench
(RM) 1.1
TFA01/TRA01
AGA3TERM (See
Note 6)
5.4
AE
5.10
RMS00
6.0
PLS00
5.4
A.01
5.13
LS500
ACCOL Workbench
(RM) 1.1
TFA01/TRA01
Hardware and Software Requirements
ACCOL Module
or Structure
3350 /
3380 /
3385
(See
Note 1)
3310,
3330,
3335
with 186
CPU
(See
Note 2)
3310,
3330,
3335
with
386EX
Real
Mode
CPU
(See Note
3)
3310,
3330,
3335
with
386EX
Protected
Mode
CPU
(See Note
4
)
3308-
10A,
3308-
30A,
3308-
10B,
3308-
30B,
3308-50B
(See Note 5)
3305
(See Note
11)
3530-10B,
3530-20B,
3530-15B,
3530-25B
(See Note
12)
ACCOL II Reference Manual
Page xvi
AGA5 4.0
S
5.10
RMS00
6.0
PLS00
5.4
A.01
5.13
LS500
ACCOL Workbench
(RM) 1.1
TFA01/TRA01
AGA7 4.0
S
5.10
RMS00
6.0
PLS00
5.4
A.01
5.13
LS500
ACCOL Workbench
(RM) 1.1
TFA01/TRA01
AGA8
(1985 version)
5.2
AC.20
5.2
AC.10
5.10
RMS00
6.0
PLS00
5.4
A.01
5.13
LS500
AGA8DETAIL 5.7
AH
5.10
RMS00
6.0
PLS00
5.7
C.01
5.13
LS500
ACCOL Workbench
(RM) 1.1
TFA01/TRA01
AGA8GROSS 5.7
AH
5.10
RMS00
6.0
PLS00
5.7
C.01
5.13
LS500
ACCOL Workbench
(RM) 1.1
TFA01/TRA01
ANIN 4.0
S
5.10
RMS00
6.0
PLS00
5.4
A.01
5.13
LS500
ACCOL Workbench
(RM) 1.1
TFA01/TRA01
ANOUT 4.0
S
5.10
RMS00
6.0
PLS00
5.4
A.01
5.13
LS500
ACCOL Workbench
(RM) 1.1
TFA01/TRA01
ARC_STORE 6.0
PLS00
ACCOL
Workbench
(RM) 1.0
LS501
ACCOL Workbench
(RM) 1.1
TFA01/TRA01
AUDIT 5.1
AC.20
5.0
AA
5.10
RMS00
6.0
PLS00
AVERAGER
4.0
S
5.10
RMS00
6.0
PLS00
5.4
A.01
5.13
LS500
ACCOL Workbench
(RM) 1.1
TFA01/TRA01
BREAK 4.0
S
5.10
RMS00
6.0
PLS00
5.4
A.01
5.13
LS500
ACCOL Workbench
(RM) 1.1
TFA01/TRA01
C (comment) 4.0
S
5.10
RMS00
6.0
PLS00
5.4
A.01
5.13
LS500
ACCOL Workbench
(RM) 1.1
TFA01/TRA01
CALCULATOR 4.0
S
5.10
RMS00
6.0
PLS00
5.4
A.01
5.13
LS500
ACCOL Workbench
(RM) 1.1
TFA01/TRA01
Hardware and Software Requirements
ACCOL Module
or Structure
3350 /
3380 /
3385
(See
Note 1)
3310,
3330,
3335
with 186
CPU
(See
Note 2)
3310,
3330,
3335
with
386EX
Real
Mode
CPU
(See Note
3)
3310,
3330,
3335
with
386EX
Protected
Mode
CPU
(See Note
4
)
3308-
10A,
3308-
30A,
3308-
10B,
3308-
30B,
3308-50B
(See Note 5)
3305
(See Note
11)
3530-10B,
3530-20B,
3530-15B,
3530-25B
(See Note
12)
*
EAudit usage in RTU 3305 with LS501 (or newer) firmware requires ACCOL Workbench software. Older DOS-based
ACCOL Tools do NOT support EAudit in the RTU 3305 with any firmware revision newer than LS500.
ACCOL II Reference Manual
Page xvii
CHARACTERIZE
5.2
AC.20
5.2
AC.10
5.10
RMS00
6.0
PLS00
5.4
A.01
5.13
LS500
COMMAND
4.0
S
5.10
RMS00
6.0
PLS00
5.4
A.01
5.13
LS500
ACCOL Workbench
(RM) 1.1
TFA01/TRA01
COMPARATOR 4.0
S
5.10
RMS00
6.0
PLS00
5.4
A.01
5.13
LS500
ACCOL Workbench
(RM) 1.1
TFA01/TRA01
CUSTOM 4.0
S
5.10
RMS00
6.0
PLS00
5.4
A.01
5.13
LS500
ACCOL Workbench
(RM) 1.1
TFA01/TRA01
DACCUMULATOR
5.9
AK
5.10
RMS00
6.0
PLS00
5.13
LS500
ACCOL Workbench
(RM) 1.1
TFA01/TRA01
DEMUX 4.0
S
5.10
RMS00
6.0
PLS00
DIFFERENTIATOR
4.0
S
5.10
RMS00
6.0
PLS00
5.4
A.01
5.13
LS500
ACCOL Workbench
(RM) 1.1
TFA01/TRA01
DIGIN 4.0
S
5.10
RMS00
6.0
PLS00
5.6
B.01
5.13
LS500
ACCOL Workbench
(RM) 1.1
TFA01/TRA01
DIGOUT 4.0
S
5.10
RMS00
6.0
PLS00
5.6
B.01
5.13
LS500
ACCOL Workbench
(RM) 1.1
TFA01/TRA01
EASTATUS 5.6
AG
5.10
RMS00
6.0
PLS00
5.6
B.01
5.13
LS500
EAUDIT 5.4
AE
5.10
RMS00
6.0
PLS00
5.4
A.01
5.13
LS500
*
ACCOL Workbench
(RM) 1.1
TFA01/TRA01
EDEMUX 5.4
AE
5.10
RMS00
6.0
PLS00
5.4
A.01
5.13
LS500
ACCOL Workbench
(RM) 1.1
TFA01/TRA01
Hardware and Software Requirements
ACCOL Module
or Structure
3350 /
3380 /
3385
(See
Note 1)
3310,
3330,
3335
with 186
CPU
(See
Note 2)
3310,
3330,
3335
with
386EX
Real
Mode
CPU
(See Note
3)
3310,
3330,
3335
with
386EX
Protected
Mode
CPU
(See Note
4
)
3308-
10A,
3308-
30A,
3308-
10B,
3308-
30B,
3308-50B
(See Note 5)
3305
(See Note
11)
3530-10B,
3530-20B,
3530-15B,
3530-25B
(See Note
12)
ACCOL II Reference Manual
Page xviii
EINTEGRATOR 5.4
AE
5.10
RMS00
6.0
PLS00
5.4
A.01
5.13
LS500
ACCOL Workbench
(RM) 1.1
TFA01/TRA01
ELSE 4.0
S
5.10
RMS00
6.0
PLS00
5.4
A.01
5.13
LS500
ACCOL Workbench
(RM) 1.1
TFA01/TRA01
ELSEIF 4.0
S
5.10
RMS00
6.0
PLS00
5.4
A.01
5.13
LS500
ACCOL Workbench
(RM) 1.1
TFA01/TRA01
EMASTER 5.6
AG
5.10
RMS00
6.0
PLS00
5.6
B.01
5.13
LS500
EMUX 5.4
AE
5.10
RMS00
6.0
PLS00
5.4
A.01
5.13
LS500
ACCOL Workbench
(RM) 1.1
TFA01/TRA01
ENCODE (See
Note 7)
4.0
S
5.10
RMS00
6.0
PLS00
5.4
A.01
5.13
LS500
ACCOL Workbench
(RM) 1.1
TFA01/TRA01
ENDFOR 4.0
S
5.10
RMS00
6.0
PLS00
5.4
A.01
5.13
LS500
ACCOL Workbench
(RM) 1.1
TFA01/TRA01
ENDIF 4.0
S
5.10
RMS00
6.0
PLS00
5.4
A.01
5.13
LS500
ACCOL Workbench
(RM) 1.1
TFA01/TRA01
ETOT/TRND 5.12
AL
5.12
RMS02
6.0
PLS00
5.13
LS500
ACCOL Workbench
(RM) 1.1
TFA01/TRA01
EVP 7.1
PLS04
FOR
4.0
S
5.10
RMS00
6.0
PLS00
5.4
A.01
5.13
LS500
ACCOL Workbench
(RM) 1.1
TFA01/TRA01
FPV 4.0
S
5.10
RMS00
6.0
PLS00
5.4
A.01
5.13
LS500
ACCOL Workbench
(RM) 1.1
TFA01/TRA01
FUNCTION 4.0
S
5.10
RMS00
6.0
PLS00
5.4
A.01
5.13
LS500
ACCOL Workbench
(RM) 1.1
TFA01/TRA01
GBBTI 5.8
AJ
5.10
RMS00
6.0
PLS00
/