Kohler 1124-RAW-0 Installation guide

Type
Installation guide
Installation and Care Guide
Whirlpool Bath with Heated Surface
Retain serial number for reference:
Conserver le numéro de série pour référence:
Guarde el número de serie para
referencia:__________________________
Français, page Français-1
Español, página Español-1
1204118-2-D
Installation Instructions
WARNING: When using electrical products, basic precautions should always be followed,
including the following:
DANGER: Risk of electric shock. Connect only to a circuit protected by a Ground-Fault
Circuit-Interrupter (GFCI)*.
Building materials and wiring should be routed away from the pump body and other heat-producing
components of the unit.
Install to permit access for servicing.
A pressure wire connector marked Earth/Ground is provided within the wiring compartment. To reduce
the risk of electric shock, connect this connector to the grounding terminal of your electric service or supply
panel with copper wire equivalent in size to the circuit conductor supplying this equipment.
Pressure wire connectors are provided on the exterior of the junction box or control within this unit to permit
connection of a bonding conductor between this unit and all other exposed metal in the vicinity, as needed to
comply with local requirements.
Grounding is required. The unit should be installed by a qualified service representative, and grounded.
WARNING: Risk of injury or property damage. Please read all instructions thoroughly before
beginning installation, including the following requirements.
WARNING: Risk of electric shock. A qualified electrician should make all electrical connections.
WARNING: Risk of electric shock. Disconnect power before servicing.
NOTICE: Follow all local plumbing and electrical codes. In Canada, install this unit in accordance with
the Canadian Electrical Code, Part 1.
*Outside North America, this device may be known as a Residual Current Device (RCD).
Product Information
Electrical Requirements
WARNING: Risk of burns, fire, electric shock, or injury. Do not operate the heater if the power
supply cord is damaged. For proper guidance to have this product repaired, please call:
1-800-4KOHLER from within the USA or Canada, or 001-800-456-4537 from within Mexico.
The installation must have a Class A Ground-Fault Circuit-Interrupter (GFCI)*. The GFCI protect against
line-to-ground shock hazard. Use a 120 V, 15 A, 60 Hz dedicated service for the bath.
If the pump supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly
qualified persons in order to avoid a hazard.
*Outside North America, this device may be known as a Residual Current Device (RCD).
Product Notices
WARNING: Unauthorized modification may cause unsafe operation and poor performance of
the whirlpool. Do not relocate the whirlpool pump, or make other modifications to the whirlpool
system, as this could adversely affect the performance and safe operation of the whirlpool. Kohler
Co. shall not be liable under its warranty or otherwise for personal injury or damage caused by any
such unauthorized modification.
1204118-2-D 2 Kohler Co.
Product Information (cont.)
Features
Factory-installed components include a whirlpool pump with power supply cord, harness, and an air switch
transmitter, a heated surface with power supply cord, user keypad, and a keypad cable.
The whirlpool pump and piping are factory-assembled.
Tools and Materials
100% Silicone Sealant
Plus:
Conventional Woodworking
Tools and Materials
• Drop Cloth
• Construction Adhesive (Optional)
• Cement* or Mortar (Optional)
• 2x4s
* Do not use gypsum cement.
Kohler Co. 3 1204118-2-D
1. Prepare the Site
NOTICE: Measure your actual product for site preparation. Note the model number located on the
whirlpool pump, then visit the product page at www.kohler.com for additional information.
NOTICE: Provide generous, unrestricted access to the pump. You must provide access for servicing the
pump. The access must be located immediately next to the pump.
NOTICE: Do not lift the whirlpool by the piping or pump, or use the piping or pump for structural
support of the whirlpool. To avoid damage to the whirlpool, lift at the sides of the whirlpool.
NOTICE: Do not support the load weight of the whirlpool by the rim.
NOTE: Drop-in, alcove, or corner installation is possible, depending on the product chosen.
Carefully unpack and inspect the new whirlpool for damage before installation. If there is damage
do not install the whirlpool; contact your dealer.
Make sure the flooring offers adequate support for your whirlpool, and verify that the subfloor is
flat and level.
Construct 2x4 stud framing.
Install an access panel for future pump servicing. The access panel must be at least 30 (762 mm)
wide by 15 (381 mm) high.
Install the rough plumbing.
Install the drain to the whirlpool according to the drain manufacturer’s instructions.
Protect the whirlpool surface by positioning a clean drop cloth in the basin bottom.
Access
Panel
Construct according
to the product dimensions.
Construct 2x4
stud framing
according to the
product dimensions.
Position the
rough plumbing.
Verify that the subfloor
offers adequate support,
and is flat and level.
Alcove Drop-In
Position the
rough plumbing.
Verify that the subfloor
offers adequate support,
and is flat and level.
1204118-2-D 4 Kohler Co.
2. Install the Whirlpool
NOTICE: Do not lift the whirlpool by the piping or pump, or use the piping or pump for structural
support of the whirlpool. To avoid damage to the whirlpool, lift at the sides of the whirlpool.
If the subfloor is not level, shim the whirlpool support blocks or molded supports as necessary.
Option 1: Install Using Construction Adhesive
NOTE: Some models come with support blocks; some models have molded supports.
Apply a generous amount of high-quality construction adhesive to the bottom of the support blocks
or molded supports. With help, carefully lift the whirlpool into position.
Option 2: Install Using a Cement or Mortar Bed
NOTE: Do not use gypsum cement or drywall compound for this application, as they will not provide an
acceptable, durable bond.
Set the basin area in 1 (25 mm) to 2 (51 mm) of mortar cement.
NOTE: The pump support (when the pump banding straps are cut) must rest directly on the subfloor.
The pump control should not be in contact with mortar.
Secure the Nailing-in Flanges (Alcove Units)
Drill a small pilot hole through the nailing-in flange at each stud. Add shims as needed.
Use large-head galvanized nails to secure the nailing-in flange to the studs.
Nail 1/4 (6 mm) thick furring strips to the studs.
Cut the Pump Banding Straps
Stud
Cement or
Mortar Bed
Clear space for pump.
Option 1
Furring
Strip
Nail
Option 2
Three Wall Alcove or
Corner Installations
Support Blocks
Apply construction
adhesive.
Banding Straps
Cut the Pump
Banding Straps
Drill a small hole
through the nailing-in
flange at each stud.
Kohler Co. 5 1204118-2-D
Install the Whirlpool (cont.)
IMPORTANT! Perform this step to make the whirlpool operate more quietly.
Cut the two pump banding straps from the whirlpool pump.
NOTE: Do not raise the pump higher than it was before you cut the straps. If the pump is raised too
high, it will not prime properly. Make sure the rubber isolation feet are in place.
Install the Plumbing
Insert the drain tailpiece into the trap. Secure the drain tailpiece to the trap.
Install the faucet valve.
Check the drain connections for leakage.
If required, install the grab bars according to the instructions.
1204118-2-D 6 Kohler Co.
3. Make the Electrical Connections
WARNING: Risk of electric shock. Make sure the power has been disconnected before performing
the following procedures.
WARNING: Risk of electric shock. Connect the junction box and whirlpool pump to a properly
grounded, grounding-type duplex receptacle protected by a Ground-Fault Circuit-Interrupter (GFCI)
or Residual Current Device (RCD). Do not remove the grounding pins from the plugs. Do not use
grounding adapters.
NOTE: A label identifying the model number and electrical rating of the whirlpool is located near the
whirlpool pump.
NOTICE: The whirlpool pump and junction box are equipped with two cords and plugs. A qualified
electrician must install a dedicated GFCI- or RCD-protected, 120 V, 15 A, grounded duplex outlet. No
other load should be on this circuit.
Install a duplex electrical outlet behind the bath, and within reach of the 24 (610 mm) power cord.
Plug the whirlpool pump and junction box into this outlet.
NOTE: Make sure the air actuator tubing is securely attached to the pump, and is not kinked or
damaged.
Bond in accordance
with applicable codes.
Junction Box
Power
Supply
24" (610 mm)
Maximum Distance
24" (610 mm)
Maximum Distance
Install a GFCI-protected
120 V, 15 A grounded outlet.
Kohler Co. 7 1204118-2-D
4. Complete the Installation
Test Run the Heated Surface
Operate the user keypad to test the temperature settings.
For additional information on heated surface operation, see the Operating Instructions - Heated
Surface section.
Test Run the Whirlpool
Fill the whirlpool to a level at least 2 (51 mm) above the top of the highest jet.
Operate the whirlpool for 5 minutes and check all whirlpool piping connections for leaks. Check for
leakage along the front, sides, and back of the whirlpool.
For additional information on whirlpool operation, see the Operating Instructions - Whirlpool
section.
Finish the Installation
Install water-resistant wallboard and all finished wall, deck, and floor materials.
Apply silicone sealant to seal all areas where the whirlpool and finished wall or deck meet.
Install the faucet trim.
Clean-up After Installation
When cleaning up after installation, do not use abrasive cleansers, as they may scratch and dull the
whirlpool surface. Use warm water and a liquid detergent to clean the surface of the whirlpool.
Remove stubborn stains or paint with turpentine or paint thinner. Do not allow cleaners containing
petroleum distillates to remain in contact with any whirlpool surface for long periods of time.
Remove plaster by carefully scraping with a wood edge. Do not use metal scrapers, wire brushes, or
other metal tools. Use a powder-type detergent on a damp cloth to provide mild abrasive action to
any residual plaster.
Important Safety Instructions
READ AND FOLLOW ALL INSTRUCTIONS
SAVE THESE INSTRUCTIONS
INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS
Fill with water at least 2" (51 mm)
above the highest jet.
Turn the jet trim ring
clockwise to
decrease the flow.
Position the jet
nozzles to direct
the water flow as
desired.
Turn the jet trim ring counterclockwise
to increase the flow.
1204118-2-D 8 Kohler Co.
Important Safety Instructions (cont.)
WARNING: When using electrical products, basic precautions should always be followed,
including the following:
DANGER: Risk of accidental injury or drowning. To reduce the risk of injury, do not permit
children to use this unit unless they are closely supervised at all times.
WARNING: Risk of personal injury. To avoid injury, exercise care when entering or exiting the
whirlpool.
WARNING: Risk of electric shock. Do not permit electric appliances (such as a hair dryer, lamp,
telephone, radio, or television) within 5’ (1.5 m) of this whirlpool.
WARNING: The use of alcohol, drugs, or medication can greatly increase the risk of fatal
hyperthermia. Prolonged immersion in hot water may induce hyperthermia. Hyperthermia occurs
when the internal temperature of the body reaches a level several degrees above the normal body
temperature of 98.6°F (37°C). The symptoms of hyperthermia include an increase in the internal
temperature of the body, dizziness, lethargy, drowsiness, and fainting. The effects of hyperthermia
include: (a) failure to perceive heat, (b) failure to recognize the need to exit the whirlpool, (c)
unawareness of impending hazard, (d) fetal damage in pregnant women, (e) physical inability to
exit the whirlpool, and (f) unconsciousness resulting in the danger of drowning.
WARNING: Risk of fetal injury. Pregnant or possibly pregnant women should consult a physician
before using the whirlpool.
WARNING: Risk of hyperthermia or drowning. Do not use the whirlpool immediately following
strenuous exercise.
WARNING: Risk of hyperthermia or drowning. Water temperature in excess of 100°F (38°C) may
cause injury. Test and adjust the water temperature before use.
WARNING: Risk of personal injury or drowning. Do not operate this unit without the guard
(cover) over the suction fitting.
WARNING: Risk of personal injury. Never drop or insert any object into any opening.
Use this whirlpool only for its intended purpose as described in this guide. Do not use attachments not
recommended by Kohler Co.
The whirlpool must be connected only to a supply circuit that is protected by a Ground-Fault
Circuit-Interrupter (GFCI)*. Such a GFCI should be provided by the installer and should be tested on a
routine basis. To test the GFCI, press the test button. The GFCI should interrupt power. Press the reset
button. Power should be restored. If the GFCI fails to operate in this manner, the GFCI is defective. If the
GFCI interrupts power to the whirlpool without the test button being pressed, a ground current is flowing,
indicating the possibility of an electric shock. Do not use this whirlpool. Disconnect the whirlpool and have
the problem corrected by a qualified service representative before using.
Flush your whirlpool system twice a month or more depending upon usage, as described in the Flush the
System section of this guide.
Repeated use of personal care products containing oils can damage plastic whirlpool components. Avoid
using bath oils.
Whirlpool hydro-massage action can cause even a small amount of bubble bath, bath soap, shampoo, or bath
oil to foam excessively. For this reason, please do not use these products during whirlpool operation.
Your new KOHLER whirlpool has been listed by Underwriter’s Laboratories, ensuring safety for you and
your family. This whirlpool also conforms to rigid ANSI and IAPMO standards set within the plumbing
industry.
*Outside North America, this device may be known as a Residual Current Device (RCD).
Kohler Co. 9 1204118-2-D
Operating Instructions Heated Surface
Keypad Operation
Power Icon - Turns the heater on and off.
Heat/Temperature Indicator - The [Flame] icon illuminates yellow, orange, or red depending on the
heat level. Yellow indicates low heat, orange indicates medium heat, and red indicates high heat.
Up Arrow - Increases the temperature.
Down Arrow - Decreases the temperature.
NOTICE: The heater will remain on until it is manually turned off by pressing the [Power] icon.
NOTE: After 60 minutes of inactivity, the heater will automatically reset to low heat if the temperature
was set to medium or high.
NOTE: The heater will turn on at the last selected temperature setting.
Error Codes
Heat indicator blinking red - The heater is not functioning.
Heat indicator blinking yellow - The temperature sensor is not functioning or is loose.
Refer to the Troubleshooting Procedures section to troubleshoot any problems.
Confirm Heating System Operation
Press the [Power] icon on the user keypad.
Observe that the heat indicator turns yellow and the heater produces low heat.
Press the [Up] arrow. Verify that the heat indicator turns orange and the temperature increases.
Press the [Up] arrow a second time. Verify that the heat indicator turns red and the temperature
increases.
Press the [Down] arrow. Verify that the heat indicator turns orange and the temperature decreases.
Press the [Down] arrow a second time. Verify that the heat indicator turns yellow and the
temperature decreases.
Press the [Power] icon to turn the heater off.
Increase Temperature
Decrease TemperaturePower On/Off
Heat/Temperature Indicator
1204118-2-D 10 Kohler Co.
Operating Instructions Whirlpool
NOTE: The water temperature in the whirlpool should never exceed 104°F (40°C).
Close the drain, then fill the whirlpool at least 2” (51 mm) above the top of the highest jet.
Use your hand to test the water temperature for comfort and safety, then carefully enter the
whirlpool.
Press the air switch to turn on the pump.
Adjust the jets for optimum air/water mixture. Turn the jet trim rings clockwise to reduce the flow
or counterclockwise to increase the flow. Position the jet nozzles to direct the water flow as desired.
Press the air switch a second time to turn off the pump.
Carefully exit the whirlpool, then open the drain and empty the water.
NOTE: If the whirlpool does not function properly, refer to the Troubleshooting Procedures section.
Care and Cleaning
For best results, keep the following in mind when caring for your KOHLER product:
Always test your cleaning solution on an inconspicuous area before applying to the entire surface.
Wipe surfaces clean and rinse completely with water immediately after applying cleaner. Rinse and
dry any overspray that lands on nearby surfaces.
Do not allow cleaners to soak on surfaces.
Use a soft, dampened sponge or cloth. Never use an abrasive material such as a brush or scouring
pad to clean surfaces.
For detailed cleaning information and products to consider, visit www.kohler.com/clean. To order Care &
Cleaning information, call 1-800-456-4537.
Flush the System
NOTE: Flush your whirlpool system twice a month or more, depending upon usage.
Turn the jet trim rings fully clockwise to reduce air induction.
Fill the whirlpool with hot water to a level at least 2 (51 mm) above the highest jet.
Add 2 teaspoons (10 ml) of a low-foaming, powder automatic dishwasher detergent and 20 ounces
(590 ml) of household bleach (5% - 6% sodium hypochlorite) to the water.
Run the whirlpool for 5 to 10 minutes. Turn off the whirlpool and drain.
If desired, rinse the bath surfaces with water.
Fill with water at least 2" (51 mm)
above the highest jet.
Turn the jet trim ring
clockwise to
decrease the flow.
Position the jet
nozzles to direct
the water flow as
desired.
Turn the jet trim ring counterclockwise
to increase the flow.
Kohler Co. 11 1204118-2-D
Flush the System (cont.)
Rinse the surfaces of the jets, faucet, grab bars, and drain, and wipe them dry with a soft cloth.
1204118-2-D 12 Kohler Co.
Troubleshooting Procedures
NOTICE: This section is for general aid only. A Kohler Co. Authorized Service Representative or
qualified electrician should correct any electrical problems. For warranty service, call 1-800-4KOHLER
from within the USA and Canada, or 001-800-456-4537 from within Mexico.
For service parts information, visit your product page at www.kohler.com.
Remove the Jets
NOTE: A special tool is provided with the replacement jets that will allow you to remove the jets from
the whirlpool. This tool is also supplied with each trim kit.
Position the jet ball nozzle so it is pointing upward.
Insert the removal tool, hooked end up, into the opening of the jet and hook the inside top of the
nozzle.
Grasp the tool firmly and place your thumb against the whirlpool wall. Pull steadily on the tool
until the jet assembly pulls free of the hole. Be careful not to lose the O-ring.
Reinstall the Jets
NOTE: To allow easy rotation and proper operation of the jet, the O-ring must be: (1) correctly positioned,
(2) lubricated, and (3) in good condition.
Install the O-ring onto the first shoulder of the jet.
Using the silicone lube packet (provided), lubricate the O-ring to prevent noisy operation of the jet.
Carefully insert the jet into the housing, then lightly push and rotate the jet until it snaps into
position. Do not force the jet.
Verify the jet is installed correctly. The jet should turn smoothly both clockwise and
counterclockwise. Remove and reinstall, if necessary.
Remove the Jets
Insert the tool hook as shown and pull the jet out of the
housing. The jet should be facing up when this is done.
Housing
Reinstall the Jets
Insert the jet into the housing, and lightly
push and rotate until it snaps in position.
Inspect and
lubricate the O-ring.
Slide the O-ring
onto the first
shoulder of the jet.
Kohler Co. 13 1204118-2-D
Troubleshooting Procedures (cont.)
Whirlpool
Symptoms Probable Causes Recommended Action
1. Whirlpool does not start
or stop.
A. No power to motor. A. Check that the pump and heater
are plugged in and that the GFCI
or RCD is switched to the correct
position. Plug in or reset the
GFCI/RCD as needed.
B. Air hose is loose or disconnected. B. Check that the hose is connected
at both the receiver/pump end
and to the air switch. Reconnect if
needed.
C. Air hose is pinched or kinked. C. Adjust hose to clear the
pinched/kinked area. If the
tubing is pinched/kinked and
cannot be readjusted, or no
noticeable pinch/kink is apparent,
poke a small hole in the tubing
with a tack and try the system
again.
D. Push button assembly is
damaged.
D. Replace the push button assembly.
E. Push button has grease in the
bleed area.
E. Disassemble the push button
assembly and wipe away any
excess grease. Reassemble the
button and retry the system.
F. Air hose is damaged. F. Replace the air hose.
G. Motor/pump does not work. G. Replace the motor/pump.
2. Motor starts, not all jets
are functioning.
A. Jet is closed. A. Rotate jet trim ring
counterclockwise to open.
B. Jet not installed correctly. B. Reinstall jet; check for O-ring
damage.
C. Jets are blocked. C. Remove blockage.
3. Pump does not prime. A. Pump shimmed too high. A. Lower pump support bracket.
4. Noisy operation. A. Pump banding straps have not
been cut. (Models with support
blocks only.)
A. Cut pump banding straps with tin
snips.
B. Jet O-ring dislodged. B. Remove jet, replace and lubricate
O-ring, and reinstall jet.
Heated Surface
Symptoms Probable Causes Recommended Action
5. Heated bath does not turn
on.
A. No power to power supply. A. Set/reset GFCI or RCD breaker;
check wiring.
B. User keypad cable loose or
damaged.
B. Check wire connections. If
necessary, replace user keypad
cable.
C. User keypad does not work. C. Check wire connections. Replace
user keypad.
D. Power supply does not work. D. Replace power supply.
6. Bath is turned on, but
there is little or no heat.
A. Heater cable loose or damaged. A. Check wire connections. If
necessary, replace heater cable.
B. Heater/insulation loose on the
bath.
B. Secure the heater/insulation to the
bath.
C. Heat indicator is yellow or
orange.
C. Press the [Up] arrow to increase
temperature.
D. Heater does not work. D. Replace the heater.
1204118-2-D 14 Kohler Co.
Troubleshooting Procedures (cont.)
Heated Surface
Symptoms Probable Causes Recommended Action
E. Temperature sensor does not
work.
E. Replace the heater.
7. Temperature does not
automatically reset to low
after 1 hour.
A. Temperature sensor does not
work.
A. Replace the heater and/or keypad.
8. Heat indicator is blinking
red.
A. Heating system needs to be
reset.
A. Press the [Power] icon to turn the
power off. Wait 10 seconds, then
turn the power on.
B. Heater does not work. B. Replace the heater.
9. Heat indicator is blinking
yellow.
A. Heating system needs to be
reset.
A. Press the [Power] icon to turn the
power off. Wait 10 seconds, then
turn the power on.
B. Temperature sensor does not
work.
B. Replace the heater.
Warranty
ONE-YEAR LIMITED WARRANTY
KOHLER plumbing products are warranted to be free of defects in material and workmanship for one year
from date of installation.
Kohler Co. will, at its election, repair, replace or make appropriate adjustment where Kohler Co. inspection
discloses any such defects occurring in normal usage within one (1) year after installation. Kohler Co. is not
responsible for removal or installation costs. Use of in-tank toilet cleaners will void the warranty.
To obtain warranty service contact Kohler Co. either through your Dealer, Plumbing Contractor, Home
Center or E-tailer, or by writing Kohler Co., Attn.: Customer Care Center, 444 Highland Drive, Kohler, WI
53044, USA, or by calling 1-800-4-KOHLER (1-800-456-4537) from within the USA and Canada, and
001-800-456-4537 from within Mexico, or visit www.kohler.com within the USA, www.ca.kohler.com from
within Canada, or www.mx.kohler.com in Mexico.
IMPLIED WARRANTIES INCLUDING THAT OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE ARE EXPRESSLY LIMITED IN DURATION TO THE DURATION OF THIS
WARRANTY. KOHLER CO. AND/OR SELLER DISCLAIM ANY LIABILITY FOR SPECIAL,
INCIDENTAL OR CONSEQUENTIAL DAMAGES. Some states/provinces do not allow limitations on how
long an implied warranty lasts, or the exclusion or limitation of special, incidental or consequential damages,
so these limitations and exclusions may not apply to you. This warranty gives you specific legal rights. You
may also have other rights which vary from state/province to state/province.
This is Kohler Co.’s exclusive written warranty.
Warranty
For Mexico
KOHLER CO.
It is recommended that at the time of purchase, you verify that all accessories and components are complete
in this package.
This Kohler product is warranted to be free of defects in material and workmanship for one (1) year from the
date of purchase as shown on the invoice or receipt.
1. Kohler Co. will only service its commercialized products through its authorized distributors.
2. To obtain warranty service, please present the invoice and corresponding warranty.
Kohler Co. 15 1204118-2-D
Warranty (cont.)
3. Through its authorized distributors, Kohler Co. promises to repair the defective product or provide a new
replacement or an equivalent model (in those cases that the model has been discontinued) when the product
is beyond repair, without any charge to the consumer.
4. The time of repair will not exceed six (6) weeks commencing on the date the product is received.
5. It is recommended that the consumer save the invoice or receipt as additional protection, as it may
substitute the warranty in the case that there is a discrepancy in the validity of the warranty.
EXCEPTIONS AND RESTRICTIONS
The Warranty will not be valid in the following cases:
1. When the product is not operated in accordance with the instructions concerning use and operation set
forth in the owner’s manual or installation instructions, and when the recommendations and warnings
included are not observed.
2. When the product has been modified or dismantled partially or totally; or has been used in a negligent
fashion and as a consequence has suffered damages attributable to the consumer, individual, or hardware not
authorized by Kohler Co.
3. This warranty does not cover the damages as a result of disaster such as fire or acts of God, including
flooding, earthquake, or electric storms, etc. To obtain a list of distributors in your area where you can
exercise your rights under this warranty, please call 001-800-456-4537.
KOHLER CO., KOHLER, WI 53044 U.S.A.
IMPORTER:
COMERCIALIZADORA INTERCERAMIC, S.A. DE C.V.
AV. CARLOS PACHECO NO. 7200, COL. MADERA 65
CHIHUAHUA, CHIH., MEXICO C.P. 31060
R.F.C. CIN141022IE9
TEL: 52 (614) 429-11-11
IMPORTER:
GAMA MATERIALES Y ACEROS, S.A. DE C.V.
AVE LOS ANGELES NO. 1800
COL VALLE DEL NOGALAR, SAN NICOLAS DE LOS GARZA
N.L. MEXICO
R.F.C. GMA901220U11
TEL: 81-1160-5500
1204118-2-D 16 Kohler Co.
Garantie (cont.)
AVE LOS ANGELES NO. 1800
COL VALLE DEL NOGALAR, SAN NICOLAS DE LOS GARZA
N.L. MEXIQUE
R.F.C. GMA901220U11
TÉL.: 81-1160-5500
1204118-2-D Français-18 Kohler Co.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52

Kohler 1124-RAW-0 Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI