  • Hello! I am an AI chatbot trained to assist you with the THERMADYNE ® Control PCB Replacement User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
CONTROL PCB REPLACEMENT INSTRUCTIONS
0-5248 Rev AB 1 May 16, 2012
© 2012 by Thermadyne Industries
Kit Componants
The following components are included in this kit.
• ControlPanelPCBAssembly
• AntiStaticStrap
• MountingScrews(4)
• Instructions
Control PCB Replacement
NOTE
This process is the same for the Fabricator and the Transmig units. Transmig is shown in these in-
structions.
1. Disconnect power from the power supply
2. Locate the anti static strap in this kit and follow instructions for proper use and fit it to your body.
3. Removefour(4)ControlPanelscrews(#1).
#1
Art # A-1
Figure1:FrontPanelScrewRemoval(Transmigshown)
ThermadyneHoldingsCorporation
Suite300,16052SwingleyRidgeRoad
St.Louis,MO63017,USA
Telephone:1-800-426-1888•Fax:1-800-535-0557
www.thermalarc.com
Manual 0-5248
Control PCB Replacement and
Part Numbers for
Fabricator 252i US W7005381
Fabricator 252i EU W7005388
Transmig 250i W7005336
Assembly Instructions
CONTROL PCB REPLACEMENT INSTRUCTIONS
4. TiltpaneltowardyouanddisconnecttheRibbonCablebyippingthetwolockingtabsoutwardthenlifting
the harness connector from the board.
Art # A-10???
Figure2:ControlPCBAccess
5. Remove the control panel assembly and replace with the new one by reversing these procedures.
6. LocatethenewControlPanelPCBAssemblyandorientitliketheonejustremovedandattachtheribbon
cable making sure it snaps into place with both locking tabs being activated.
7. Carefullysetthecontrolpanelassemblybackintothefrontpanelandsecurewiththefourscrews.
8. Apply power to the unit and verify the control panel is working.
NOTE
Any information/calibrations previously stored are now gone. All information is now factory default
and any desired calibrations will need to be done again.
© 2012 Thermadyne Industries, Inc. www.thermadyne.com Printed in Mexico