Life Ionizers Next Generation LIFE MXL-5 C User manual

Type
User manual
1
LIFE MXL-5LifeIonizers.com/support
2
LIFE MXL-5 LifeIonizers.com/support
Welcome to the LIFE Ionizers family!
Congratulations on the purchase of your new alkaline mineral water
ionizer. We are grateful to our many customers for recognizing our
eorts in providing the best water ionizer available!
Ionized Alkaline Mineral Water promotes good health with its superi-
or hydration, mineralization, oxygenation and cellular detoxication.
Our ionizers use a series of internal and external ltration systems
and the nest-quality platinum-coated titanium plates, to create
alkaline water with the highest anti-oxidant potential in the industry.
What do I need to know?
Please read all safety warnings before the installation or
operation of your LIFE Ionizer to ensure proper product usage.
To receive warranty service, you must register your warranty
online. Please see enclosed warranty card for detailed instructions.
Refer to this manual when you have questions on adjustments
and how to change your lters. We also have instructional videos
and help guides online at LifeIonizers.com/support.
Changing your lters is important! To ensure optimal perfor-
mance and to guarantee your warranty, your ionizer has a new
RFID Technology built into the internal lters which will give you
a warning that your lter life is low and that you should replace
your lter. If the lter life runs out, the ionizer will not function
until the lter is changed. Its important to have lters changed
on time so the performance of your ionizer will continue.
3
LIFE MXL-5LifeIonizers.com/support
Table of Contents
Safety Guide
Product Specications
Package Contents
Important to Remember
Parts of the Ionizer
MXL-5 Installation
Quick Connect Fittings and Tubing
Display Overview
Function Options
MXL-5 Operation Method
Internal Filter Replacement
Filter Reset Indicators
Citric Acid (Scaling) Cleaning Filter
Filtration Media
Pre-Filter Replacement
Acidic Cleaning Instructions & Routine Maintenance
Common Problems and Solutions
Operation Warnings/Error Messages
How Alkaline Water is Made
Alkaline/Acidic/Puried Water
Uses of Ionized Alkaline/Acidic Water
Performance Features
Frequently Asked Questions
4
7
8
10
12
14
16
17
18
23
24
25
26
28
29
30
31
32
33
34
35
38
39
4
LIFE MXL-5 LifeIonizers.com/support
Safety Guide
Power Plug
As with most electrical appliances, electrical parts in this
ionizer are electrically live even when the switch is o.
Power cord should not be touched with wet hands
Use only (110v) in the USA, Mexico and Japan. Most
other countries require (220v). The power cord cannot
be altered from manufacturers specs.
Do not crimp or staple the power cord
Power cord should be plugged directly into an
electrical outlet
Dusty or dirty electrical outlets may cause safety
issues
Bending, twisting, pulling or putting heavy objects
onto the power word may cause electrical problems
including re.
If power cord, plug or electrical outlet are damaged,
discontinue use immediately.
Unplug the electric power when
not in use for a long time (over 3
days)
5
LIFE MXL-5LifeIonizers.com/support
Ionizer
Place machine in an upright position only
Do not install this unit in direct sunlight or near a heater,
replace or other heat source
Do not place the machine in humid areas such as
bathrooms
If wall mounted, secure rmly and correctly
Do not use water with a temperature of over 95
degrees Fahrenheit or 35 degrees Celsius
This machine should not be repaired or otherwise
disassembled by any unauthorized person as it may
cause electrical re or shock and will void the
manufacturers warranty
Do not clean this machine by spraying the ionizer with
water as it may cause electrical shock.
Do not use benzene, thinner, or chemicals to clean the
unit as it can damage the housing.
Do not block the unit vent as it can cause overheating
and/or electrical problems.
Do not block the water passage or tubing
Do not place anything on the unit
Don’t shake or drop
the unit
If the ionizer
machine falls into
water:
1. Unplug power cord
from electrical outlet
2. Wipe the machine
down and place in
shaded area
3. Contact your LIFE
Ionizer dealer
6
LIFE MXL-5 LifeIonizers.com/support
Ionized water
If inexperienced with drinking Ionized Alkaline Water,
users are encouraged to start with level 1
When drinking Ionized Alkaline Water - Do not take
prescription or other medications for approximately one
hour before and after drinking water. Ionized alkaline
water hydrates more eciently, therefore will deliver
more medication than tap water.
Store Ionized Alkaline Water in an air-tight glass
container and refrigerate for up to 2 days
DO NOT DRINK ACIDIC WATER
Do not store Alkaline or Acidic water in metal containers,
although you can put alkaline water in the Water for LIFE
Stainless Steel bottles as they are designed to maintain
pH and ORP
Aluminum and brass containers will be tarnished by
alkaline and acidic water
If not used for several days, run water through the unit
for 1 to 3 minutes before starting
If the machine will not be
used for several days:
1. Unplug the power cord
from the electrical outlet
2. Turn o the water valve to
avoid leaking
3. Remove lters, drain and
place in refrigerator in
plastic bags.
4. Let water run on the
“Puried Water setting for
at least 3-5 minutes
before any operation
7
LIFE MXL-5LifeIonizers.com/support
Product Specications
Special features Fully convertible: counter-top to
under counter
Cleaning function Advanced RADC Cleaning System
Display Full Color LED Display w/ Automatic
Voice Prompting
Filtration Dual Internal, Custom Pre-lter
Flow Control Automatic
Power in watts Adjusts up to 250 watts
ORP Output up to -500
(Enhanced ORP at drinkable levels)
pH Output pH range from 5.5 up to 10.3
Protection Automatic Heat Sensor
Power System MAX Yield SMPS Power System™
Rated Voltage Dual voltage input compatibility
110/220 volts. All you need is the
power plug or adapter. When
plugged into the power source the
unit automatically recognizes voltage.
Settings 1 Puried, 3 Acidic, 4 Alkaline
Warranty 7 Year Warranty
Dimensions 12.5” W | 15” H | 6.25” D
Plate Material Platinum over Industrial Titanium
8
LIFE MXL-5 LifeIonizers.com/support
Package Contents
Extra Fuse
1/4” Tubing Hose
User Manual
BTB Chemical
pH Color
Chart
Reagent Drops
(pH Test Drops)
Suction Cup
Located in the Power
Switch at the bottom
of the machine
Flexible
Hose
Pull down
Diverter Valve
9
LIFE MXL-5LifeIonizers.com/support
10
9.0
8.0
7.0
6.0
5.0
4.0
Alkaline
Water
Acid
Water
Neutral
PH Tester Kit Instructions:
1. Place 1-2 ounces of water you are
testing into a glass
2. Add 2-3 drops of Reagent Drops
3. Stir water to observe the color
change
4. Compare to “pH COLOR CHART
to determine pH and acid levels.
When handling the pH test (reagent drops):
1. Keep away from eye area. If eyes become irritated, ush
thoroughly and consult a doctor.
2. If accidentally swallowed, drink water and consult a doctor.
3. Store in an airtight container away from the reach of children.
4. Drops are ammable. Keep away from children.
How to measure the pH of your water
A pH color chart and a bottle of Reagent Drops are included with
your ionizer in case you would like to test the water from your new
ionizer.
10
LIFE MXL-5 LifeIonizers.com/support
You must run 2-3 gallons of water through the pre-lters before
you connect them to the ionizer. To do this, install the pre-lters
into their housings, connect a piece of tubing to the outlet con-
nection on the pre-lter housing and run it into the sink so you
can ush them out with water. This hydrates the lters and cleans
them from any loose media. After you nish this procedure, con-
nect your pre-lter back to your ionizer and run normally. This
needs to be done every time you put in new pre-lters.
The pre-lter housings must be replaced every 2 years.
SEE PAGE 14 FOR COUNTER TOP INSTALLATION INSTRUCTIONS
SEE PAGE 16 FOR UNDER COUNTER INSTALLATION INSTRUCTIONS
Important to Remember
Pre-lter Installation & Maintenance
Ionizer Installation
Plugs located on the bottom of the ionizer must be removed
before installation.
Do not overtighten the patch cable connection on the back of
the ionizer when plugging in patch cable.
Run the ionizer and check for leaks at all tubing locations from
the Diverter Valve to the Ionizer itself before operating the unit.
11
LIFE MXL-5LifeIonizers.com/support
Settings
Flow rate must be set before adjusting or running your ionizer.
Set ow rate no higher than 2.5 liters per minute. Anything higher
could cause internal damage.
When adjusting the settings, the buttons must be pressed
quickly as failure to do so will result in booting you out of the
program menu.
The unit must be dispensing water before pressing the buttons.
Adjust the ow rate (LPM) by slowing down the water ow to
ionizer from the source water:
- Cold Water Connect (for under undercounter units)
- Faucet Diverter ( for countertop units)
SEE PAGE 14 FOR COUNTER TOP INSTALLATION INSTRUCTIONS
SEE PAGE 16 FOR UNDER COUNTER INSTALLATION INSTRUCTIONS
Ionizer Care
Do not twist top of faucet. This will damage the faucet.
We recommend internal lters and pre-lters be changed
annually.
Citric acid cleaning lter should be used 3 to 4 times
per year.
Use cold water only with your ionizer
12
LIFE MXL-5 LifeIonizers.com/support
xxx-xxxxx-xx-x x
6
Inlet
Outlet
345
** Plugs must be removed before installation.
See page 18 for Quick Connect Fittings and Tubing instructions.
Parts of the Ionizer
BACK
BOTTOM
1. First Filter Cover
2. Wall Mount Screw
Holes
3. Speaker
4. Bar Code and Serial
Number
5. Second Filter
6. Under Counter
Installation
Plug/Connector
1. Source water inlet
2. Acidic outlet
3. On/O Power Switch
4. Fuse Box
5. Power Plug
5
1
2
3
4
13
LIFE MXL-5LifeIonizers.com/support
1. Control Panel
2. Flexible Spout
3. LCD Panel
2
1
3
FRONT
14
LIFE MXL-5 LifeIonizers.com/support
LIFE MXL-5 Installation
Refer to diagrams on page15.
(help video on LifeIonizers.com/support)
STEP 1: Unscrew the existing aerator from your faucet.
STEP 2: Use Teon plumbers tape on the threads. Make sure the black rubber
washer is inside the diverter valve before you screw it onto your
faucet. This assures a proper seal. (Three dierent sized adaptors
are included for non-standard sized faucets).
STEP 3: Unscrew the round nut from the side of the diverter valve. Place the
1/4” tubing through the nut and over the opening. Press 1/4” tube on
the barb tting and screw the nut back onto the diverter valve over
the tubing. Tubing should now t snugly onto the diverter valve.
STEP 4: Run the other end of the 1/4” tubing that you attached to the
diverter valve to the (IN) on the Pre-lter. Connect another piece of
1/4” tubing to the (OUT) on the Pre-lter. Run 2-3 gallons of water
through the pre-lter before connecting them to the unit. This tube
will then go to the inlet valve on the bottom of the ionizer in STEP 6.
STEP 5: Remove the plugs in the following manner: Lay the ionizer down
on its back and you will see two white elbows extruding from the
bottom of the machine. There will be an o-white collar around the
base of the elbow (see page 18). Push in the collar against the face of
the tting. With the collar held in this position, you can extract the
plug from the machine. It is sometimes helpful to use the back of a
butter knife or screw driver to remove the plugs.
STEP 6: Insert the 1/4” tubing from the (OUT) on the Pre-lter to the inlet
valve on the bottom of the ionizer using the quick connect instruc-
tions on page 18. Insert another 1/4” tube in the outlet elbow on the
bottom of the ionizer and run the other end into the sink securing it
with the suction cup provided. Some units may contain water
Don’t be alarmed; we test units for quality before shipment.
STEP 7: Run the ionizer and check for leaks at all tubing locations from
the Diverter Valve to the Ionizer itself before operating the unit.
15
LIFE MXL-5LifeIonizers.com/support
Inlet
Outlet
DIVERTER CONNECTION
STEP 1:
STEP 2:
aerator
STEP 3:
round nut
1/4” tubing
Diverter valve
STEP 4:
elbows
STEP 5:
Bottom of ionizer
Diverter valve
inlet valve
outlet
valve
Bottom of ionizer
suction
cup
Pre-Filters
In Out
plugs
(in green)
STEP 6:
NOTE: Run 2-3 gallons of water
through the pre-lters before you
connect them to the ionizer.
** Plugs must be removed before installation.
Pre-lters
Diverter valve
Option:
Diverter Valve Adapter if
needed for your type of sink.
16
LIFE MXL-5 LifeIonizers.com/support
Quick Connect Fittings
and Tubing
Push the tubing into the quick connect. The collar (gripper )
has teeth which hold the tubing rmly in position while the “O” Ring
provides a permanent leak proof seal.
Check the Seal: Pull on the tubing to see if the seal is secure.
Check for leaks.
Ensure system is depressurized before removing ttings. Push in the
collar against the face of the tting. With the collar held in this position,
the tube can be removed. The tting can then be re-used.
collar
To ensure an optimal seal, tubing should be cut with the end square.
An angled cut or distortion of the tubing will not provide an ecient seal
and may cause leaks. Determine the length of tubing needed for
the connection and cut the segment of tubing to the appropriate length.
push in collar
pull tubing out
quick connect
TO CONNECT:
TO DISCONNECT:
17
LIFE MXL-5LifeIonizers.com/support
1. ON/OFF Button
2. Alkaline Selector
3. Purify Selector
4. Acidic Selector
5. Menu/Function
6. Filter 1 Indicator
7. Filter 2 Indication
8. Filter 1/Life Indicator
9. Filter 2/Life Indicator
10. Operation Display Lamp
11. Level Indicator
12. Indicator Water Type (Alkaline/Acidic/Purify)
13. pH Indicator
1211
9
813
10
4325 6 7 1
Display Overview
18
LIFE MXL-5 LifeIonizers.com/support
Function Options
AMPS AND LITERS PER MINUTE (LPM)
NOTE: the unit must be dispensing water before pressing the buttons.
Press and hold “FILTER 1” & “FILTER 2” simultaneously for 5 seconds in
order to enable the display of the Amps & LPM reading indicator light.
Two numbers will then appear on the indicator.
The top number is the amps number followed by the digit A.
The bottom number is the Liters per Minute (LPM) followed by the
digit L.
Once the LPM is displayed, you can make the necessary adjustment
to the water ow in order to adjust the LPM to the unit. Adjust the
LPM by
slowing down water ow to ionizer from the source water:
- Under Counter - Cold Water Connect
- Counter Top - Faucet Adapter
KEY NOTE: The slower the ow, the stronger the alkaline or acidic
water is produced. We recommend that you set the machine
between a ow of 1.5-3.0LPM.
For strong 11+pH alkaline or 2.5 pH acid water, we recommend
that the ow rate be set at 1.1-1.5 LPM. Do not set below 1.0 LPM
because it will error out and display E1.
NOTE: Your pH will be determined by your water source. If youre
on well water, your water is soft, or your TDS is too low, then you
might need a remeneralizing cartridge or a pre-lter to add alkaline
minerals so your unit can ionize properly.
NOTE: FLOW RATE MUST BE SET TO GET PROPER PH LEVELS.
Recommended ow rate is 1.5-3.0 LPM
Amps & LPM (liters per minute) indicators
19
LIFE MXL-5LifeIonizers.com/support
Recommended ow rate is 1.5-3.0 LPM
SOUND/VOLUME ADJUSTMENT (F10)
To enter the Volume Adjustment please do the following:
Press and hold the “MENU” button for 5 seconds.
Once you do this VOL” will appear on the display and below that
it will show a number.
To increase volume, press and release the “FILTER 2” button, to
decrease the volume setting press and release the “FILTER 1”
button.
MENU
FILTER 1 FILTER 2
20
LIFE MXL-5 LifeIonizers.com/support
PH TESTING WITH DROPS
To test and to determine the pH of your water, you will have to select
the level you are testing as well as combining the liquid reagent pH
drops provided with the purchase of your ionizer with a sample of
water gathered from your ionizer.
1. To begin this process, you will need a small clear glass of some sort.
2. Turn on your water ionizer and select the level of alkaline or acidic
water you will want to test. Please wait 10 seconds before collect-
ing the water.
3. You will then need to add 2-3 liquid reagent pH drops to the glass
rst and collect 1 ounce (2 tbsp) of water from your ionizer.
4. After that you will need to compare the water you tested with the
color ph chart provided with the pH drops.
5. You will need to adjust the amperage levels depending on your
source water. We recommend you set water pH to ALK1-light
blue/ALK2-dark blue/ALK3-light purple/ALK4-dark purple.
6. To do this follow the F-20 steps on the next page.
2-3 dropssmall clear glass 2 tbsp water
Add to glass:
1.
+
ALK1
ALK2
ALK3
ALK4
2. 3.
4. 5.
Adjust amperage
levels by following
the F-20 steps on
the next page
6.
collect water
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52

Life Ionizers Next Generation LIFE MXL-5 C User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI