FLIR ThermaCAM P65 Quick Start

Type
Quick Start

This manual is also suitable for

FLIR ThermaCAM P65 Below you will find brief product information for FLIR ThermaCAM P65 in order to help you get to know its most important features and possible uses: The FLIR ThermaCAM P65 is a handheld thermal imaging camera that can be used to visualize and measure temperature differences. It is equipped with a 320x240 pixel detector and a standard 25˚x19˚ lens, which gives it a theoretical IFOV of 1.36 mRad. This means that it can detect a 1-inch target at a distance of 61 feet. The P65 has a variety of features that make it a versatile tool for a variety of applications, including:

  • Auto and manual focus

FLIR ThermaCAM P65 Below you will find brief product information for FLIR ThermaCAM P65 in order to help you get to know its most important features and possible uses: The FLIR ThermaCAM P65 is a handheld thermal imaging camera that can be used to visualize and measure temperature differences. It is equipped with a 320x240 pixel detector and a standard 25˚x19˚ lens, which gives it a theoretical IFOV of 1.36 mRad. This means that it can detect a 1-inch target at a distance of 61 feet. The P65 has a variety of features that make it a versatile tool for a variety of applications, including:

  • Auto and manual focus
QuickStart: FLIR P60, P65
© 2011 The Snell Group / 322 N. Main St. / Suite 8 / Barre, VT / 05641 / 800.636.9820 / www.thesnellgroup.com
FLIR P60, P65 Page 1
1. MEMORY: Insert a Compact Flash memory card in to its slot under the rubber cover below the eyepiece.
Available memory card space is indicated in the Status LCD.
2. POWER: Slide the release tab forward, pivot the battery door open and insert a fully charged battery.
Battery life is indicated in the Status LCD.
3. START: Briefly press the green ON/OFF button to switch on the camera.
Pres and hold the ON/OFF button to turn the camera off.
NOTE: Depending on the model there are two viewing options.
Detachable LCD pad with controls. (buttons function as the matching buttons on the camera body) To
remove pad, pull straight back then pivot upwards, front first.
Eyepiece viewing display. You must individually adjust the focus of eyepiece so that the display’s menu
lettering is sharp and crisp.
FOCUS: Focus can be achieved by two methods: Auto focus and manually.
To Auto Focus (focus on objects in the center of the image) press and hold the “A” button for one or two
seconds.
Manually adjust focus by moving the Joystick up or down. While you are focusing, an indicator will appear
on the left side of the screen.
NOTE: 1. The Joystick is slightly offset or rotated clockwise for ergonomic reasons.
NOTE: 2. Earlier models might differ in the control buttons and functions.
4. AUTO ADJUST: (Level and Span) Momentarily pressing the “A” button will perform a one time auto adjustment
of the thermal Level and Span.
Battery Door
Laser ON/OFF
Laser Lens & Cap
Digital Camera Lens & Focus
Eyepiece
Programmable
Functions
Status LCD
Removable LCD
&
Control Pad
ON/OFF
Joystick
Battery Door Release
“C” (select/cancel)
“S” (pause/save)
“A” (auto)
QuickStart: FLIR P60, P65
© 2011 The Snell Group / 322 N. Main St. / Suite 8 / Barre, VT / 05641 / 800.636.9820 / www.thesnellgroup.com
FLIR P60, P65 Page 2
5. MANUAL ADJUST: (Level and Span) Press the Joystick straight in to
display the Horizontal menu bar.
Point to the [Image] menu then using the joystick move down to [Manual
Adjust] and press in on the joystick to put the camera into Manual Adjust
Mode. “Manual” will be displayed in the upper left display.
While in Manual Adjust Mode, pressing the “C” button will toggle
joystick function between its normal function (up/down=Focus &
left/right Zoom) and Level/Span (up/down=Level adjust &
left/right=Span adjust)
Note: Indicator arrows (Fig.3) will be displayed on the color Palette showing the direction of change.
6. PAUSE IMAGE: Momentarily pressing the “S” button will Pause or Freeze the displayed image. Momentarily
pressing the “S” again will return you live image mode.
7. SAVE IMAGE: To Save the displayed image we suggest that you first Pause/Freeze the image as above.
To Save a paused image momentarily pressing the “S” button.
To Save an image directly from live mode press and hold the “A” button.
8. RECALL IMAGE: Press the Joystick straight in to display the Horizontal menu bar.
Point to the [File] menu then using the joystick to move down to [Images] and press in on the joystick.
Using the joystick up/down or left/right, Highlight the desired image thumbnail.
Open by again pressing in on the joystick.
Press the “C” button to return to live image mode.
9. PALETTE: Press the Joystick straight in to display the Horizontal menu bar.
Point to the [Image] menu then using the joystick move down to [Palette] and press in on the joystick to
display the Palette Dialog Box.
Use the Joystick left/right to select a different palette.
10. RANGE: Press the Joystick straight in to display the Horizontal menu bar.
Point to the [Image] menu then using the joystick move down to [Range] and press in on the joystick to
display the Range Dialog Box.
Use the Joystick left/right to select a different Temperature Range.
11. EMISSIVITY: Press the Joystick straight in to display the Horizontal menu bar.
Point to the [Analysis] menu then us the joystick to move down to [Object Parameters] and press in on the
joystick.
Use the joystick up/down to highlight the current emissivity value.
Use the joystick left/right to change the value.
Press the “C” button to live image mode.
12. BACKGROUND (T. Reflective): Press the Joystick straight in to display the Horizontal menu bar.
Point to the [Analysis] menu then us the joystick to move down to [Object Parameters] and press in on the
joystick.
Use the joystick up/down to highlight T. Reflective.
Use the joystick left/right to change the value.
Press the “C” button to live image mode.
IFOV =1.36 mRad (Theoretical with 320x240 Detector and standard 25˚x19˚ lens) Detect 1in. target @ 61ft.
Span Level
Fig.3 Change Indicators
  • Page 1 1
  • Page 2 2

FLIR ThermaCAM P65 Quick Start

Type
Quick Start
This manual is also suitable for

FLIR ThermaCAM P65 Below you will find brief product information for FLIR ThermaCAM P65 in order to help you get to know its most important features and possible uses: The FLIR ThermaCAM P65 is a handheld thermal imaging camera that can be used to visualize and measure temperature differences. It is equipped with a 320x240 pixel detector and a standard 25˚x19˚ lens, which gives it a theoretical IFOV of 1.36 mRad. This means that it can detect a 1-inch target at a distance of 61 feet. The P65 has a variety of features that make it a versatile tool for a variety of applications, including:

  • Auto and manual focus

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI