MITYFLEXPERISTALTICPUMPS
PERISTALTICPUMP
OWNERSMANUAL
907&908SERIES
QUALITYMANAGEMENTSYSTEMREGISTERED
TOISO9001INTERNATIONALSTANDARDS
ANKO PRODUCTS INC. PUMP DIVISION
www.ankoproducts.com
2
ThankyouforpurchasinganAnkoMityflex®Peristalticpump.Wearesureyou
willbecompletelysatisfiedwithitsperformance.Shouldyouneedassistanceor
havequestionsregardingtheuseorinstallation,pleasevisitourwebsiteat
www.ankoproducts.com.
TABLEOFCONTENTS
WARRANTY 3
WARNING 3
RETURNANDREPAIR 3
PUMPFEATURES 4
PUMPINSTALLATION 4
FLOWCHARTS 5
ROLLERSELECTION 6
FUSEINSTALLATION/FANASSEMBLY 6
TUBINGINSTALLATION 7
TUBINGINSTALLATIONPROCEDUREA 7
TUBINGINSTALLATIONPROCEDUREB 8
TUBINGINSTALLATIONPROCEDUREC
ROLLERBRACKETASSEMBLY
9
10
ILLUSTRATIONOFPUMPHEAD
ASSEMBLY 11
REPLACEMENTPARTSLIST 11
Everyprecautionforaccuracyhasbeentakeninthepreparationofthismanual,however,ANKO
PRODUCTS,INC.neitherassumesresponsibilityforanyomissionsorerrorsthatmayappearnor
assumesliabilityforanydamagesthatresultfromtheuseoftheproductsinaccordancewiththe
informationcontainedinthismanual.
3
LIMITEDWARRANTY
ANKOPRODUCTS,INC.,warrantsequipmentofitsmanufactureandbearingitsidentification
tobefreefromdefectsinworkmanshipandmaterial.ANKOPRODUCTS,INC.’sliabilityunder
thiswarrantyextendsforaperiodofoneyearfromthedateofdeliveryfromourfactoryor
authorizeddistributor.Itislimitedtorepairingorreplacinganydeviceorpartofanydevice
whichisreturned,transportationprepaid,tothefactorywithinoneyearofdeliverytothe
originalpurchaser,andwhichisproventobedefectiveuponexaminationbyus.ANKO
PRODUCTS,INC.disclaimsallliabilityforconsequentialdamageofwhatevernature,damage
ofequipmentduringtransportation,damage,damageduetoimproperhandling,installation
orimproperoperationorfordeterminingsuitabilityfortheparticularuseintendedbya
purchaser.Replaceablepartsincludingtubessuppliedwiththeproductarenotcoveredby
anywarrantieseitherexpressedorimplied.ANKOPRODUCTS,INC.,makesnowarranties
eitherexpressorimplied,includingimpliedwarrantyormerchantability,otherthanthose
statedabove.Norepresentativehasauthoritytochangeormodifythiswarrantyinany
respect.Jurisdictionandvenueforenforcementofthiswarrantymaybebroughtonlyinthe
StateofFlorida.Thiswarrantgivesyouspecificlegalrights,andyoumayalsohaveother
rightswhichvaryfromstatetostate.
WARNING
ANKOPRODUCTS,INC.assumesnoresponsibilityorliabilityforchemicalcompatibilityofour
tubinginspecificapplications.ALWAYSpretesttubinginaccordancewithtubing
manufacturer’sspecifications.Tubingthatshowssignsofswelling,embrittlement,orother
deteriorationshouldnotbeused.
RETURNANDREPAIRREQUESTS
Pleasedirectallwarrantyrequeststotheappropriatedistributortheproductwaspurchased
from.
4
TheMITYFLEX®907and908modelsarefixedspeedgeneralpurposepumpsfordispensing
fluidbasedonproducts.The907ishousedinacaseandiscontrolledbyasimpleon/off
switchthatactivatesthepump.The908ismanufacturedwithazincplatedsteelbracketand
sixinch
leadwiresforconvenientassemblytoyourOEMapplication.
FEATURES
1. ELECTRICAL:115VAC,60HZ;OPTIONS:24to240VAC;50Hz,60Hz,or50/60Hz;12&
24VDC.The907alsoincludes;On/Offswitch;6footpowercord.
2. PRIMING:Unitisselfprimingandwillholdvacuumwhenoff.
3. OPERATION:Pumpcanrundrywithoutdamagingthemotorordriveunit,howeverthe
tubinglifewillbereduced.
4. CONSTRUCTION:Polypropylenehousingandcaseusingstainlesssteelfasteners.
5. MAX.HEADPRESSURE:Maximumworkingpressure40PSI.
6. MAX.SUCTIONLIFT:29feet(8.8m)withHO.
7. RATING:ACUnits‐100%ofcontinuousoperationat25°Cambient;DCUnits‐100%
continuousoperationat40°Cambient.
8. FLOWRATE:.4987ml/min.Dependingonthetubingused.(Seepage5).
9. FUSE:(907only)Locatedontheexteriorofthecase.(Seepage6forreplacement
procedureandpage5forfusetype).
INSTALLATIONINSTRUCTIONS
1. POWERREQUIREMENTS:Voltageandfrequencyofpowersupplymustbethesameas
shownonunit.
2. WIRINGCONNECTIONS:Allwiringandelectricalconnectionsmustcomplywithlocal
andnationalelectricalcodes.
3. MOUNTING:(907)Caseenclosedmodelhasrubberfeetandmountingflanges.This
enablesittobeusedonaflatsurfaceorwallmounted.Besurethatoneofthesetsof
ventholeshasplentyofairforcirculation.(908)MountingbracketsforOEM
applications.Besurethereisplentyofspaceforaircirculation.Donotallowtubingto
becrimped.
4. MOUNTINGLOCATION:Pump
shouldbeplacedinadrylocationwithadequatecooling
provided.Theambienttemperatureshouldnotexceed25°CforACunitsor40°Cfor
DCunits..
WARNING
Thisunitshouldnotbeusedinoutdoororhazardouslocations.
5
MODEL907FLOWRANGECHART
FLOWRATES(ml/min.)FUSE/ FAN
Tubing
ID
.062In
(1.6mm)
.125In
93.2mm)
.187In
(4.7mm)
.250In
(6.3mm)
Fuse Fan
Unit# 
907002 .4 1.7 4 7 .5amp
907007 1.5 5.9 14 25 .5amp None
907014 3 12 28 48 1amp None
907023 5 19 46 81 1amp 1211151800
907028 6 24 56 98 2amp 1211151800
907036 8 30 72 126 1amp 1211152000
907049 10 41 98 172 5amp 1211152500
907058 12 49 116 208 2amp 1211151800
907075 16 63 150 263 3amp 1211151800
907108 23 91 216 378 3amp 1211161800
907129 27 108 258 452 3amp 1211161800
907172 36 144 344 602 3amp 1211161800
907203 43 170 406 711 3amp 1211161800
907282 60 237 564 987 5amp 1211161800
Flowratebasedonpumpingwaterar25°Cand0PSIusing60durometerthermoplasticelastomertubing.
MODEL908FLOWRANGECHART
(ml/min.)
Tubing
ID
.062In
(1.6mm)
.125In
93.2mm)
.187In
(4.7mm)
.250In
(6.3mm)
RPMS AMPS Fan
Unit# 
908002 .4 1.7 4 7 2 .37
908007 1.5 5.9 14 25 7 .37
908014 3 12 28 48 14 .37
908023 5 19 46 81 23 .42 1211161800
908028 6 24 56 98 28 .75 1211161800
908036 8 30 72 126 36 .90 1211162000
908049 10 41 98 172 49 1.0 1211162500
908058 12 49 116 208 58 1.2 1211161800
908075 16 63 150 263 75 1.5 1211161800
908108 23 91 216 378 108 1.9 1211151800
908129 27 108 258 452 129 2.2 1211151800
908172 36 144 344 602 172 2.2 1211151800
908203 43 170 406 711 203 3.3/2.2 1211151800
908282 60 237 564 987 282 3.3/2.2 1211151800
Flowratebasedonpumpingwaterar25°Cand0PSIusing60durometerthermoplasticelastomertubing.
6
ROLLER/TUBINGSELECTION
UsethefollowingcolorcodedrollerswiththeappropriatetubingI.D.Yourunitisassembled
withblackrollers.Redrollersareincludedinyourtubingkit.Seeseparateinstructionsfor
rollerreplacementenclosedinyourtubekit.
Roller TubingID ML/Revolution
Black 1/4”(.250) 3.5
Black 3/16”(.187) 2.1
Red 1/8”(.125) 0.8
Red 1/16”* 0.21
*The1/16”IDtubingmustbeinsertedinto3/16”(.187)IDX3/8”(.375)ODtubing(sleeve)for
operationinpump.
FUSEINSTALLATION(907)
(Seepage4forfusetypeandpage10forfuseorderinginformation)
1. Disconnectpowertopump.
2. Removefourscrewsfromcasefront.
3. Carefullyremovecasecoverbeingsurenottopullwiresapart.
4. Laytheunitonaflatsurface.
5. Findfuseholderandpullapart.
6. Removeoldfuseandreplacewithnewfuse.
7. Replacecasecover.
FANASSEMBLY
(Seepage4forreplacementnumber)
Disconnectthepowerfromthepump.
Thefanispressedontotherotorshaft.Onall907caseunits,thefanispressedonwithmetal
clipawayfromthemotor.OnallOEM908units,thefanispressedonwiththemetalclip
towardthedoor.
7
TUBINGINSTALLATION
Inspectalltubingregularlyandreplaceifanysignofdeteriorationoccurs.Alwayswearsafety
glassesandprotectiveclothingwhenworkingwithchemicals.Seechartbelowforproper
tubinginstallationprocedureforyourunit.
*90_002through90_014 ProcedureA(below)
90_023through90_049 ProcedureAorB(page6or8)
90_058through90_282 ProcedureAorC(page6or9)
*WARNING:MODEL907002,907007,907014,908002,908007and908014GEARTRAINS
CANBEDAMAGEDIFDRIVESHAFTISROTATEDBYHANDFORTUBEINSERTION.
PROCEDUREA
(Ifunitisnewstartwithstep#6.)
1. Disconnectpowertothepump.
2. Disconnectthesuctionanddischarge
tubingfromthepumptubing.
3. Removefourscrewsandpumpcover
frompumphead.
4. Pulloutoldpumptubinganddiscard.
5. Cleanrollerrace,removingand
particlesthatcoulddamagetubing.
6. Connectpowerandrunatslowest
speeduntilrollerbracketassemblyis
inpositionasshowninfigure1.
7. Pushnewtubingintoinletport,
anchoringtubingingrippers.Ifusing
a9”pieceoftube,11/2”shouldbe
extendedoutsideofinletport.(figure
2)
8. Continuetorunatslowestspeed
carefullyfeedingtubeintoraceasthe
rollersturn.(figure3)
(Keepfingersawayfromrollers).
9. Inserttubingintooutletport(figure
4)andreplacecover.
8
PROCEDUREB
Followsteps15inprocedureA,then
continuewiththefollowing.
6. Usingextrabracket(figure1),rotate
rollerbracketassemblyuntilitisin
positionasinfigure2.(Besurepower
isdisconnected).
7. Pushnewtubingintoinletport,
anchoringthetubingingrippers(see
figure3).Ifusing9”pieceoftube,1
1/2”shouldbeextendedoutsideof
inletport.
8. Continuetorotatetherollerbracket
assemblyusingtheextrabracket,
whilepushingthetubingintothe
rollerrace.(figure4)
9. Insertthetubingintotheouterport
(figure5)andreplacethecoverand
screws.
9
PROCEDUREC
Withoutremovingthepumpcover,runtheentireunitat
highRPM.Pulltheoldtubingoutfromoutletportpump.
Installnewtubebyinsertingintoinletport;continue
feedingtube1/4”inatatimeallowingtheroller
assemblytopushtubingthrough.Whentubingishalf
wayaroundtherace,putyourfingerovertheinlethole
ofthetubeandcontinuetofeedtubing1/4”atatime,
thisshouldmakeinstallationeasier.Continueuntil
desiredtubingextensionisobtained.Rununitforabout
oneminute.
WARNING
ANKOPRODUCTS,INC.assumesnoresponsibilityorliabilityforchemicalcompatibilityofour
tubinginspecificapplications.ALWAYSpretesttubinginaccordancewithtubing
manufacture’sspecifications.Tubingthatshowssignsofswelling,embrittlement,orother
deteriorationshouldnotbeused.
ROLLERBRACKETASSEMBLYINSTRUCTIONS
10
ForRollerReplacement
(Aplasticrollerbracketassemblyissuppliedwithunitsrangingfrom2to108RPM.Noassemblyisrequiredforthe
plasticbracket.Ifnewrollersarerequiredanewassemblymustbeordered).
1. Toremovetherollerbracketassemblyfromthepump,useaflatheadscrewdriverand
pryopenbothsidesofthespringstotheedgeofthebracket.
2. Pulltherollerbracketassemblyofftheshaftholdingontotherollerareaofthebracket.
3. Holdingthetopandbottomofthebracket,slidethespringofftothesideandlaythe
assemblyonaflatsurface.Trynottoletitfallapartasyouwillneedtoputittogether
thesamewayitisnow.
4. Removethetopbracketandtherollers.
5.
Ifarollerpincomesoutofitsrecess,replaceitatthistime.
6. Placethenewrollersonthepinsandreplacethetopbracket.Besurethattheflatinthe
innerholeofthetopbracketlinesupwiththeflatonthebottombracket.
7. Slidethespringfastenerbackoverthebracket.Donotsnapthespringtogether.
8. Matchingtherollerbracketflattotheoutputshaftflat,slidetherollerbracketassembly
downuntilitstopswithoutusingforce.
9. Snapthespringtogether.
Illustrationofthepumpassembly.


11
1 Fan 
2 Screw(1)832x7/8”
3 Gearmotor
4 MountingBracket(908only)
5 PumpHousing 
6 Tube
7 Screws(4)1032x11/4”
8 *NylonWasher
9 RollerBracketAssembly
10 PumpCover
11 Screws(4)832x5/8”
The908mountingbracketisreplacedwiththe907casecoveronthecasemodel.
ReplacementPartsList
Contactyourlocaldistributortoorder.Pleaserememberto includethecompletemodel
numberwhenyouplaceyourorderforreplacementparts.Forfanordersusethechartonpage
4forthepartnumber.
Item UnitNumber
PlasticRollerBracket(Red)………………………………………… RBA17180325
PlasticRollerBracket(Black)……………………………………… RBA17180125
BlackRollerBracketAssembly…………………………………… RB12120100
RedRollerBracketAssembly…………………………………….. RB12120300
PumpKit……………………………………………………………………. 907101000010
Includeshousing,cover,w/bearing,fourscrews,andwasher.
TubeKit……………………………………………………………………… TU1124000000
Includes9”ofeachofthefollowing:1/16”ID(inasleeve),1//8”ID,3/16”ID,and¼”IDthermoplasticelastomer
tubing.(Seechartonpage5fortubingandrollercompatibility).
Model907only:
Fuses.5amp(5/pack)……………………..FU11270005
Fuses1amp(5/pack)……………………..FU11270100
Fuses2amp(5/pack)……………………..FU11270200
Fuses3amp(5/pack)……………………..FU11270300
Fuses5amp(5/pack)……………………..FU11270500
*Nowashernecessaryforunitsusinganallplasticrollerbracketassembly.(2to36RPM)
(Copyright12/97)2840000000Revised2/13/2002
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11

ANKO 908 User manual

Category
Heat pumps
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI