FS S5850 Series User guide

Category
Network switches
Type
User guide

FS S5850 Series switches are a powerful and versatile networking solution for data centers and enterprise networks. With a range of port options, including SFP28 and QSFP28, and a variety of features, including Layer 3 routing, PoE+, and stacking, the S5850 Series switches are ideal for a variety of applications, including server connectivity, data center aggregation, and campus networking.

FS S5850 Series switches are a powerful and versatile networking solution for data centers and enterprise networks. With a range of port options, including SFP28 and QSFP28, and a variety of features, including Layer 3 routing, PoE+, and stacking, the S5850 Series switches are ideal for a variety of applications, including server connectivity, data center aggregation, and campus networking.

SWITCHS MANAGEABLES L3 POUR CENTRES DE DONNÉES
MANAGED L3-SWITCHES FÜR RECHENZENTREN
MANAGED L3 DATA CENTER SWITCHES
V1.0
Quick Start Guide
Quick Start Anleitung
Guide de Démarrage Rapide
1
Introduction
Power Cord x2
Grounding Cable x1 Rubber Pad x4 M4 Screw x10
Sliding Rail x2
Console Cable DB9 to RJ45 x1 Cat 5e Cable x1
Accessories
EN
Thank you for choosing S5850 Series switches. This guide is designed to familiarize you with the layout
of the switches and describes how to deploy the switches in your network.
Rear Mounting Bracket x2
Front Mounting Bracket x2
S5850-48S8C-DC
S5850-48B8C
S5850-48S8C
Hardware Overview
Front Panel Ports
Front Panel LEDs
SS5850-48S8C-DC
2
EN
Ports Description
SFP28
QSFP28
SFP28 ports for 1/10G transceivers
QSFP28 ports for 40/100G transceivers
ID
SYS
ID indication function enable.
Blue
On
On
On
On
O
Green
O
O
Amber
Loop Blinking
O
ID indication function disable.
The system is normally running.
Alarm or error occurs in the system.
No power or the system is not running or abnormality.
MGT
Breakout
Green
Port is linked.
Port is not linked.
One or more 100G/40G ports are breakout.
None of the 100G/40G ports is breakout.
LEDs State Description
25G SFP28
100G QSFP28
S5850-48S8C-DC
Breakout
ID
MGT
SYS
25G SFP28
100G QSFP28
3
Back Panel
S5850-48S8C/S5850-48B8C
S5850-48S8C-DC
EN
SFP28
On
Blinking
Green
25G port is linked.
25G packets are receiving or transmitting.
On
Blinking
Amber
10G/1G port is linked.
10G/1G packets are receiving or transmitting.
O Port is not linked
QSFP28
On
Blinking
Green
100G/40G port is linked.
100G/40G packets are receiving or transmitting.
On
Blinking
Amber 10G/1G port is linked.
10G/1G packets are receiving or transmitting.
O Port is not linked.
LEDs State Description
ID SYS
CON
ETH
PS2 PS1
ID SYS
CON
ETH
PS2 PS1
ID
Power Supply Module
SYS
CONETH USB
ID
Power Supply Module
Grounding
point
SYS
CONETH USB
Installation Requirements
Safety Precaution
Back Panel LEDs
Power source should be removed before cleaning switches. Do not use wet rags to wipe
switches and clean switches with liquid.
The following precautions should be followed to avoid equipment damage and personal injury
caused by improper use:
Do not place switches near water or in a wet environment, and prevent water or moisture
from entering switch chassis.
Do not place switches on an unstable case or table, since the dropping would cause serious
harm to switches.
Maintain good indoor ventilation and clear air holes of switches.
Switches shall work normally under correct voltage, so make sure the operating voltage
agrees with the voltage marked on switches.
To reduce the risk of electric shock, do not remove its enclosure when a switch is working,
and don't do so at will even if it is not powered.
4
EN
ID
SYS
ID indication function enable.
Blue
On
On
On
On
O
Green
O
Blinking
O
Amber
ID indication function disable.
The system is normally running.
Alarm or error occurs in the system.
No power or the system is not running or
abnormality.
ETH Green
Port is linked.
Port is receiving or transmitting packets.
Port is not linked.
LEDs State Description
A power supply module port
Power Supply Module
RJ45 Console Port (CON)
ETH
USB
An RJ45 console port for serial management
An Ethernet management port
A USB management port
Ports Description
5
Anti-static gloves must be worn when replacing interface board to prevent static electricity
from damaging veneer.
Installation Site
Ensure that there are some spaces at the inlet and outlet of switch for heat dissipation of switch
chassis.
To ensure a normal work environment, S5850 series switches should have the following
requirements for workplace:
Ensure that rack and working platform have good ventilation and heat dissipation systems.
Ensure that rack and working platform are rm enough to support the weight of a switch and
its accessories for installation.
Ensure rack and working platform are well earthed.
Mounting the Switch
1. Install the front mounting brackets and the sliding rails on the switch.
Rack Mounting
EN
2. Fix the rear mounting brackets to the rack.
6
EN
3. Push the switch slightly into the rack along the sliding rails, and x the other end of front
mounting brackets upon the front hold strip of rack using screws and matching nuts.
7
1. Connect one end of the grounding cable to a proper earth ground, such as the rack in which the
switch is mounted.
2. Secure the grounding lug to the grounding point on the switch back panel with the washer and
screws.
Grounding the Switch
NOTE: 1. Only S5850-48S8C-DC can be grounded.
2. The earth connection cannot be removed unless all connections are disconnected.
EN
WARNING: Do not install power cables while the power is on.
1. Plug the AC power cord into the power port on the back of the switch.
2. Connect the other end of the power cord to a power source.
(The S5850-48S8C-DC power port is dierent from the power ports of S5850-48S8C and
S5850-48B8C. )
Connecting the Power
1. Plug the compatible SFP28 transceiver into the SFP28 port.
2. Connect a ber optic cable to the ber transceiver. Then connect the other end of the cable to
other ber devices.
Connecting the SFP28 Ports
8
EN
9
1. Plug the compatible QSFP28 transceiver into the QSFP28 port.
2. Connect a ber optic cable to the ber transceivers. Then connect the other end of the cable to
other ber devices.
Connecting the QSFP28 Ports
1. Connect the DB9 female connector of the mini USB to RS-232 serial port on the computer.
2. Insert the mini USB connector into USB port on the back of the switch.
Connecting the USB port
EN
USB
1. Insert the RJ45 connector of the console cable into the RJ45 console port on the back of the switch.
2. Connect the other end of the console cable to the RS-232 serial port on the computer.
Connecting the Console Port
1. Connect one end of a standard RJ45 Ethernet cable to the Ethernet port of a computer.
2. Connect the other end of the cable to ETH port on the back of the switch.
Connecting the ETH Port
10
EN
11
Configuring the Switch
Step 1: Connect the computer to the Management port of the switch using the network cable.
Step 2: Set the IP address of the computer to 192.168.1.x. ("x" is any number from 2 to 254.). Set the
subnet mask of the computer to 255.255.255.0
Configuring the Switch Using the Web-based Interface
Step 3: Open a browser, type http://192.168.1.1, and enter the default username and password,
admin/admin.
Step 4: Click sign in to display the web-based configuration page.
EN
?x
OK Cancel
General
IP address:
Subnet mask :
Default g a t e wa y :
You can get IP settings assigned au t omatically if your ne tw or k
supports this capabilit y . Othe r wis e , y o u need to ask your net w o r k
administrator for the a ppropriate IP settings .
Internet Protocol Version 4 (TCP/IPv4) Pr opert ies
Use the foll owing IP address:
Obtain an IP address automatically
Preferred DNS server:
Alternate DNS server:
Validate settings upon exit Advanced...
. . . 21168192
0255
255255
. . .
. . .
. . .
. . .
Obtain DNS server address automatically
Use the foll owing DNS server addre sses:
Step 1: Connect a computer to the switch's console port using the supplied console cable.
Step 2: start simulation software such as HyperTerminal on the computer.
Step 3: Set the parameters of the HyperTerminal: 115200 bits per second, 8 data bits, no parity, 1 stop
bit and no flow control.
Step 4: Enter the default username and password, admin/admin
Configuring the Switch Using the Console Port
x
Quick Connect
Protocol: Serial
Flow Control
DTR/DSR
RTS/CTS
XON/XOFF
Save sessionShow quick connect on startup
Open in a tab
Connect Cancel
COM3
115200
8
None
1
Port:
Baud rate:
Data bits:
Parity:
Stop bits:
Name of pipe:
12
EN
13
Troubleshooting
After loading fails, the system will keep running in the original version. At this time, users should
re-check if physical port connection are good rstly. If some ports are not connected, then
re-connect them to ensure that physical connections are correct, and begin re-loading. If physical
connections are correct, then check the loading process information displayed on the super terminal
to verify if there are input errors. If there are input errors, correct them and re-load.
Loading Failure Troubleshooting
If system password is lost or forgotten, the following method can be used to reset the password:
1. Connect the console port of the switch to the computer through the console cable.
2. Press ctrl + b to enter the Uboot mode.
3. Start the system with an empty configuration file with no password.
4. Bootrom#boot_flash_nopass
5. Bootrom#Do you want to revert to the default config file?[Y|N|E]:
User Password Lost Troubleshooting
Power System Troubleshooting
According to the power indicator on the front panel, the switches can be used to determine whether
the power system of the switch is faulty. If the power system is working normally,the power indicators
should remain lit. If the power indicator is unlit, the power supply system is not working. Please check
the following:
1. Whether the switch power cable is connected correctly.
2. Whether the power supply of the switch matches the required power supply.
NOTE: Forgetting your username and password and restoring them through console port
may cause configuration loss and business interruption. Please remember your username
and password.
EN
Online Resources
Download
Help Center
Contact Us
https://www.fs.com/products_support.html
https://www.fs.com/service/fs_support.html
https://www.fs.com/contact_us.html
Product Warranty
FS ensures our customers that any damage or faulty items due to our workmanship, we will oer a
free return within 30 days from the day you receive your goods. This excludes any custom made
items or tailored solutions.
Warranty: S5850 series switch enjoys 5 years limited warranty against defects in materials
or workmanship. For more details about warranty, please check at
https://www.fs.com/policies/warranty.html
Return: If you want to return item(s), information on how to return can be found at
https://www.fs.com/policies/day_return_policy.html
14
EN
5
S5850-48S8C-DC
S5850-48B8C
S5850-48S8C
Einführung
Netzkabel x2
Erdungskabel x1 Gummipad x4 M4-Schraube x10
Gleitschiene x2
Konsolenkabel (DB9 auf RJ45) x1 Cat 5e-Kabel x1
Zubehör
Vielen Dank, dass Sie sich für Switches der Serie S5850 entschieden haben. Diese Anleitung soll
Sie mit dem Layout der Switches vertraut machen und beschreibt, wie Sie die Switches in Ihrem
Netzwerk einsetzen.
Hintere Montagehalterung x2
Vordere Montagehalterung x2
15
DE
Hardware-Übersicht
Ports an der Vorderseite
LEDs an der Vorderseite
Port Beschreibung
SFP28
QSFP28
SFP28 für 1/10G Transceiver
QSFP28 Ports für 40/100G Transceiver
ID
SYS
ID-Anzeigefunktion aktivieren.
Blau
An
An
An
An
Aus
Grün
Aus
Aus
Braun
Blinkt dauernd
Aus
ID-Anzeigefunktion deaktivieren.
Das System läuft normal.
Im System ist ein Alarm oder Fehler aufgetreten.
Kein Strom oder das System läuft nicht oder es liegt
eine Fehlfunktion vor.
MGT
Breakout
Grün Der Port ist verbunden.
Der Port ist nicht verbunden.
Ein oder mehrere 100G/40G-Ports sind Breakouts.
Keiner der 100G/40G-Ports ist ein Breakout.
LED Status Beschreibung
16
DE
S5850-48S8C-DC
S5850-48S8C-DC
25G SFP28
100G QSFP28
Breakout
ID
MGT
SYS
25G SFP28
100G QSFP28
Rückseite
S5850-48S8C/S5850-48B8C
S5850-48S8C-DC
SFP28
An
Blinkt
Grün
25G-Port ist verbunden.
25G-Pakete werden empfangen oder gesendet.
An
Blinkt
Braun
10G/1G-Port ist verbunden.
10G/1G-Pakete werden empfangen oder gesendet.
Aus Der Port ist nicht verbunden.
QSFP28
An
Blinkt
Grün Der 100G/40G-Anschluss ist verbunden.
100G/40G-Pakete werden empfangen oder gesendet.
An
Blinkt
Braun
Der 10G/1G-Port ist verbunden.
10G/1G-Pakete werden empfangen oder gesendet.
Aus Der Port ist nicht verbunden.
LED Status Beschreibung
ID SYS
CON
ETH
PS2 PS1
ID SYS
CON
ETH
PS2 PS1
ID
Stromversorgung
SYS
CONETH USB
ID
Stromversorgung
Erdungspunkt
SYS
CONETH USB
17
DE
Installationsanforderungen
Sicherheitshinweise
LEDs an der Rückseite
Vor dem Reinigen von Switches sollte die Stromquelle entfernt werden. Verwenden Sie keine
nassen Lappen zum Abwischen der Switches und reinigen Sie die Switches nicht mit
Flüssigkeiten.
Die folgenden Vorsichtsmaßnahmen sollten befolgt werden, um Geräteschäden und Verletzungen
durch unsachgemäßen Gebrauch zu vermeiden:
Stellen Sie die Switches nicht in der Nähe von Wasser oder in einer feuchten Umgebung auf,
und verhindern Sie, dass Wasser oder Feuchtigkeit in das Gehäuse der Switches eindringt.
Stellen Sie die Switches nicht auf ein instabiles Gehäuse oder einen Tisch, da ein Herunterfallen
zu schweren Schäden an den Switches führen würde.
Sorgen Sie für eine gute Raumbelüftung und halten Sie die Luftlöcher der Switches frei.
Stellen Sie sicher, dass die Betriebsspannung mit der auf den Switches angegebenen Spannung
übereinstimmt.
Um die Gefahr eines Stromschlags zu verringern, nehmen Sie das Gehäuse nicht ab, wenn ein
Switch in Betrieb ist, und tun Sie dies auch nicht, wenn er nicht unter Spannung steht.
ID
SYS
ID-Anzeigefunktion aktivieren.
Blau
An
An
An
An
Aus
Grün
Aus
Blinkt
Aus
Braun
ID-Anzeigefunktion deaktivieren.
Das System läuft normal.
Im System ist ein Alarm oder Fehler aufgetreten.
Kein Strom oder das System läuft nicht oder es
liegt eine Fehlfunktion vor.
ETH Grün
Der Port ist verbunden.
Der Port empfängt oder sendet Pakete.
Der Port ist nicht verbunden.
LED Status Beschreibung
Ein Stromversorgungsmodulport
Stromversorgung
RJ45 Console-Port (CON)
ETH
USB
Ein RJ45-Console-Port für die serielle Verwaltung
Ein Ethernet-Verwaltungsport
Ein USB-Verwaltungsport
Port Beschreibung
18
DE
Beim Austausch der Schnittstellenkarte müssen antistatische Handschuhe getragen werden, um
zu verhindern, dass statische Elektrizität das Gehäuse beschädigt.
Installationsort
Stellen Sie sicher, dass am Ein- und Ausgang des Switches genügend Platz für
dieWärmeableitung des Switch-Gehäuses vorhanden ist.
Um eine normale Arbeitsumgebung zu gewährleisten, sollten die Switches der Serie S5850 die
folgenden Anforderungen an den Arbeitsplatz erfüllen:
Stellen Sie sicher, dass das Rack und die Arbeitsplattform über gute Belüftungs- und
Wärmeableitungssysteme verfügen.
Stellen Sie sicher, dass Gestell und Arbeitsbühne stabil genug sind, um das Gewicht eines
Switches und seines Zubehörs für die Installation zu tragen.
Stellen Sie sicher, dass Gestell und Arbeitsbühne gut geerdet sind.
Montage des Switches
1. Bringen Sie die vorderen Montagehalterungen und die Gleitschienen am Switch an.
Rack-Montage
19
DE
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46

FS S5850 Series User guide

Category
Network switches
Type
User guide

FS S5850 Series switches are a powerful and versatile networking solution for data centers and enterprise networks. With a range of port options, including SFP28 and QSFP28, and a variety of features, including Layer 3 routing, PoE+, and stacking, the S5850 Series switches are ideal for a variety of applications, including server connectivity, data center aggregation, and campus networking.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages