3D Systems 284107-00 User manual

Type
User manual

This manual is also suitable for

1
User Guide
ProJet
®
Cart Station
2
TABLE OF CONTENT
INTRODUCTION .............................................................................................................................................................................. 3
ABOUT THIS GUIDE ........................................................................................................................................................................ 3
COPYRIGHT .................................................................................................................................................................................... 4
IMPORTANT SAFETY INFORMATION ............................................................................................................................................ 5
SPECIFICATIONS and REQUIREMENTS ....................................................................................................................................... 6
FAMILIARIZATION ........................................................................................................................................................................... 7
FACILITY REQUIREMENTS ............................................................................................................................................................. 8
PREPARATION FOR WALL-MOUNT ............................................................................................................................................8-9
WALL-MOUNT INSTALLATION ..................................................................................................................................................... 10
TABLE-MOUNT INSTALLATION .................................................................................................................................................... 11
OPERATION ..............................................................................................................................................................................12-15
MAINTENANCE .............................................................................................................................................................................. 16
SERVICE and SUPPORT ............................................................................................................................................................... 17
SPARE PARTS ..........................................................................................................................................................................18-20
3
INTRODUCTION
Thank you for purchasing “ProJet® Cart Station. We pride ourselves in our ability to offer customers three dimensional printing
solutions. The 3D System team is condent your system will provide many years of service.
ABOUT THIS GUIDE
• Safety: Read prior to handling VisiJet® Materials or operating the printer. The safety sections inform you of handling the
material properly and avoid damage and injury when operating the printer. For more detailed material safety information,
refer to VisiJet® Material Handling Guide.
• System Requirements: Provides electrical requirements prior to plugging in your printer for operation.
• Familiarization: Provides a brief description of the Cart Station.
• Operations: Describe how the station functions.
• Error Messages: Denes the error messages you may see on the station’s display and provide the actions to take.
• Maintenance: List maintenance procedures which must be done to ensure optimum performance.
• Technical Support: List of contact numbers of sale and support personnel for your printer system.
4
COPYRIGHT
© 2013 by 3D Systems, Inc. All rights reserved. Subject to change without notice. This document is copyrighted and contains
proprietary information that is the property of 3D Systems, Inc. The licensed user, in the name of whom this document is registered
(the “Licensed User”) does not have the right to copy, reproduce, or translate this document in any way or to any media without the
prior written consent of 3D Systems, Inc. No copies of the document may be sold or given to any person or other entity.
ProJet®, the 3D logo and VisiJet® are registered trademarks of 3D Systems, Inc.
Improvements
3D Systems may (but shall not be obligated to) make improvements to this document from time to time. However, the Licensed
User acknowledges that at any time after the expiration of the date of issuance, 3D Systems may institute a periodic charge or fee
payable by the Licensed User in return for ongoing receipt of improvements. It is the responsibility of the Licensed User to pro-
vide 3D Systems with current information as to its name and address. The Licensed User also undertakes to notify 3D Systems
promptly in the event that it considers any of the data contained in this document to be incomplete or erroneous in any respect, in
connection with Licensed Users particular use or generally.
FCC Notice
This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in
a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used
in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment
in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his
own expense.
Changes or modications not expressly approved by 3D Systems could void your authority to operate this equipment.
Limitations of Warranty and Liability
This information is provided by 3D Systems for the convenience of its customers. It is believed to be reliable, but NO REPRESEN-
TATIONS, GUARANTEES, OR WARRANTIES OF ANY KIND ARE MADE AS TO ITS ACCURACY, FITNESS FOR A PARTICULAR
USE, OR THE RESULTS TO BE OBTAINED THEREFROM. The information is based in whole or in large part on laboratory work
and does not necessarily indicate performance in all conditions. Notwithstanding any information provided by 3D Systems or its
afliates, the customer remains fully responsible for determining which federal, state, or local laws or regulations, or industry prac-
tices are relevant to activities in which it engages, as well as assuring that those laws, regulations, or standards are complied with
under actual operating conditions, and 3D Systems undertakes no responsibility in these areas.
IN NO EVENT WILL 3D Systems BE RESPONSIBLE FOR DAMAGES OF ANY NATURE, INCLUDING SPECIAL OR CON-
SEQUENTIAL DAMAGES, RESULTING FROM THE USE OF OR RELIANCE UPON THIS INFORMATION. THE CUSTOMER
ASSUMES ALL RISK RESULTING FROM THE USE OF THIS INFORMATION. Customers use of the materials that follow is an ac-
knowledgment of its agreement to the foregoing. Any customer not wishing to be bound should return this material to 3D Systems.
Nothing contained herein is to be considered as permission, recommendation, nor as an inducement to practice any patented
invention without permission of the patent owner.
5
IMPORTANT SAFETY INFORMATION
SafetySymbolsandDenitions
Safety Guidelines
Before using the printer and cart station, your company should have a safety program in place. The safety pro-
gram should:
Label and point out hazardous equipment, materials, and procedures.
Explain what to do in case of an emergency.
Provide information about hazards of equipment and materials in the form of Material Safety Data Sheets or
Safety Data Sheet (MSDS / SDS). The MSDS / SDS are provided with all materials supplied by 3D Systems.
Read and follow all station instructions.
Follow all safety rules and heed all cautions and warnings in this guide.
Do not use any material without reviewing the Material Safety Data Sheets/Safety Data Sheets (MSDS/SDS).
Do not attempt to access, service, or adjust Cart Station components. Do not attempt to perform any mainte-
nance procedures unless specically trained to do so.
Certied service personnel are those who completed the 3D Systems service training package and certied
to perform service tasks. Certication may occur at different levels, and service providers should only perform
tasks they are authorized and certied to complete.
Disconnect the Umbilical cable before cleaning the cart or material cart.
Do not remove any cart panels in an attempt to add or remove material.
Do not energize the Cart Station if the Umbilical has been pinched or damaged.
To prevent potential skin-irritation and sensitization due to contact with waste material, follow all guidelines
within Build Material Safety.
Do not operate the Cart Station if the cart is:
Being serviced
Missing any protective panels
Missing any hoses or hose ttings
Electrical Shock Hazard: High voltage electricity is accessible in the vicinity of this sign or behind the access
panel. High voltage can cause severe burns or death. Access panels are for service only and should be opened
only by certied service personnel or trained maintenance personnel.
Harmful Irritant Warning: Indicates that skin or eye irritation could result while exposed to a chemical composition.
Caution: Indicates something may happen that could cause loss of data, damage to equipment, or personal injury
Wear gloves when handling uncured VisiJet® build material.
Follow these safety guidelines when operating the station:
6
SPECIFICATIONS and REQUIREMENTS
Cart Station Properties
Cart compatibility ProJet ™ 6000, ProJet ™ 7000
MountingConguration Wall Mount / Table Mount
Screen Display 4 lines of text, 20 characters per line, Backlit
Screen Language English
User Interface 4 Momentary Push buttons
User Safety Emergency Stop (E-stop) provided
Screen Size (W x H) 3” by 1”
Pump Direction Print tray into cart
Cart Station Functions Heat, Stir, Pump, Heat & Stir, Stand-by
Dimensions (W x D x H) 12” x 6” x 12 1/4”
Weight 5.7 kg
Capacity Maintains one cart per Cart Station
Noise < 65 dB
Cart Umbilical Harting 42pin Cart plug, 3 foot, male
Electrical
Facility Electrical Requirements 100-240 VAC, 50 / 60 Hz w / grounded receptacle
Circuit Breaker Amps 5 Amps
Power Consumption 100 watts peak, 50 watts nominal
Amps 0.5 amps nominal, 1 amp max
Output Voltage (motor/heater) 24 volts DC
Fused Amperage (heater) 2.5 amps
Fused Amperage (motor) 0.3 amps
Power Cord 2 meter (6 foot) grounded IEC type (included)
Temperature Ranges
Material Temperature Range 20 - 40 degrees C, 28 nominal
Default Heater Temperature 35 deg. C for ProJet™7000, | 50 deg. C for ProJet™6000
Heater Temperature Range 20 - 50 degrees C
Ambient Room Temperature 20-26 degrees C (68 – 79 degree F)
Ambient Relative Humidity 20 – 50%
7
Cart Station User Interface
When pressed, station will stop running.
Used for different purposes depends of the current state:
To cancel current routine and get back to the main menu.
If cancel used during “Settings setup” sequence at ANY
time - it will restore system settings saved into the buffer
before begging of the whole sequence.
Reboot if system in the “HOLD” state.
Access to “Service” screen (only from Main menu - press
and hold for 5 Sec).
Accept the set value and move to the next screen.
Alternated cursor in dual option menus or decrement value
Alternated cursor in dual option menus or increment value
User interface screen displays menus of cart station current
state.
A
B
C
D
E
D C B
A
F
E
F
FAMILIARIZATION
This Cart Station, (PN: 284107-00) is a wall or table mounted power supply to provide power to the material cart that is sup-
plied with the ProJet® 6000 / 7000. If the cart is removed from the printer, it can be connected to the Cart Station instead.
Once connected to the Cart Station, the cart will perform the following:
1. Pump material from the print tray to the cart until the tray is empty or the cart is full.
2. Heat the material to the proper temperature.
3. Stir the material at xed time intervals to keep the material homogeneous.
Each Cart Station will maintain one material cart. 3D Systems recommends proper material storage, as this is an important
factor of achieving the ne details and reliable material properties that the ProJet 6000/7000 can provide.
Control Box
Umbilical
Connector
Cord
Receptacle
ON / OFF
Switch
Umbilical
Holder
Table-Mount Bracket
8
If you choose to mount your station to the wall, the table mount
bracket attached to the cart station will need to be removed.
Required Tools: (not supplied): #1 Phillips head Screwdriver,
5mm Allen Wrench, T20 Torx plus driver
Using a Phillips screwdriver, loosen the three (3) thumb-
screws and open front panel.
PREPARATION FOR WALL-MOUNT
Remove Table Mount Bracket
FACILITY REQUIREMENTS
Electrical Requirements
Facility Electrical Requirements 100-240 VAC, 50 / 60 Hz w / 15 amp. grounded receptacle
Temperature Ranges
Ambient Room Temperature 20-26 degrees C (68 – 79 degree F)
Ambient Relative Humidity 20 – 50%
Thumbscrews
Using a T-20 torx plus driver, remove the two (2) m4 x10 torx screws securing the bottom of station to the table-
mount bracket. Loosen the two top screws and slide the station to clear the keyholes in stations. Lift station from
bracket and retain screws.
Two screws at the top
Two screws at the bottom
Using a T-20, remove the two torx plus screws securing the umbilical holder to the table mount bracket. Retain screws
incase you may want to mount cart to a table in the future.
9
If you choose to mount your station to the wall, It is important to follow these steps to ensure that the station is mounted correctly
and the umbilical is in reach to the material cart without it being stressed.
Required Tools: (not supplied): Measuring Tape; Pencil for tick mark; Template that is supplied in this guide; #2 Phillips screw-
driver
The Cart Station should be mounted so that a grounded wall 100-240 VAC / 50-60 Hertz, 15 amp receptacle is within reach of
the power cord. Before powering on the station, the grounding terminal connection to earth ground should be veried.
cm (42”)
FLOOR
cm (11”)
Two keyholes
Bottom of station
Two screw holes
11.03”
(280.2 mm)
7.48”
(190 mm)
Using a 5mm Allen wrench, remove the two M6 screws from the bottom left corner of cart.
Orient holder as shown and align holder holes to the screw holes at the bottom left corner of station. Install umbilical
holder using the two M6 screws that were removed to secure umbilical holder to the cart station.
Using a measuring tape, measure a height of 42” from
the oor and up the wall; add a tick mark on the wall
indicating where the bottom of the station will be.
Measure a height of cm (11”) from the tick mark and
up the wall; add another tick mark indicating where the
station’s two mounting keyholes will be.
Measure a height of 11.03” (280.2 mm) and the width
of 7.48” (190 mm) from the screw holes center points to
the center point of keyholes. Add tick marks indicating
where the station’s mounting points will be.
10
WALL MOUNT INSTALLATION
Install four anchors into the marked hole locations; the anchors should be ush
to the wall.
Install two screws to the two top anchors. Leave a little gap between the anchor
and screw to install station.
Required Tools & Fasteners (not supplied): Phillips Screwdriver; Four (4) 6mm or 1/4” screws Anchors (anchors depend on
the wall type).
Anchors should be
ush to the wall
Install station’s two upper keyholes (backside of station) onto the two upper screws.
Turn the three thumbscrews counterclockwise to unlock the front cover and open cover.
Keyholes
Thumbscrews
Align the stations’s two bottom holes to the two bottom pilot holes in wall and install two screws. Tighten
the upper and lower screws securely.
Install two screws
11
TABLE MOUNT INSTALLATION
If you choose to mount the cart station to a table, it is important that the table height is at least 37” to prevent the umbilical from hitting
the oor.
The Cart Station should be mounted so that a grounded wall 100-240 VAC / 50-60 Hertz, 15 amp receptacle is within reach of the
power cord. Before powering on the station, the grounding terminal connection to earth ground should be veried.
Install the cart station table mount to the table as shown.
Turn the two adjusting keys that are located underneath the table mount clockwise until the cart station is securely attached to
the table.
Two (2) Adjusting Keys
12
Powering ON the Cart Station
NOTE: Use only the UL listed IEC type power cord that is supplied with the Cart Station.
Connect power cord to the power receptacle located on the right side of station and into facility’s receptacle. Ensure the
receptacles meet the electrical requirements noted in “Facility Requirements” section.
Connect station umbilical connector to the material cart connector. It is acceptable to connect the umbilical to the cart
when the station is ON.
Ensure that the print tray is connected to the cart before you start the cart station.
Power on cart station, the user interface screen will display.
Plug Power Cord into
Station Receptacle
Power Switch
Connect umbilical con-
nector to the material
cart’s connector
User Interface Screen
OPERATION
NOTE: The material requires 24 hours to heat prior to use. Avoid heating material over 72 hours; doing so will
cause the material to age.
13
NOTE: Before every use, verify the umbilical plug and connector are clean before connecting.
Caution: Never disconnect the station from the cart while it is stirring or pumping. First, cancel the operation
in the User Screen or turn off the power switch before disconnecting from cart.
Once powered up, the system will go through the
“System Check” that includes a 24 volt power supply
check, controller hardware check and cart connection
check.
If cart is connected and all cart’s sensors are
within the expected range “Cart is detected” will
appear on the display screen.
If cart is connected, but if any of the sensors are
out of range or not connected, an Error will occur
and will halt the system. The error message will
display the cause of the halt on the screen.
If cart is not connected, an Error message will
display “No Cart detected.” This system state will
not halt the system.
System Check
After the System Check, the “Main Menu Screen” will
display along with the “System settings” options and
status of the cart. RUN (6000 Cart)” or “RUN (7000
Cart)” will be displayed to indicate if it is in 6000 Cart or
7000 Cart mode.
Main Menu Screen
ProJet 6000 / ProJet 7000 Cart setting Menu
System Settings
Mixing ON / Mixing OFF
Mixing ON Time
This could be adjusted in 10 percent incre-
ments. Setting it for example to 10 percent
will run mixing motor for 1 minutes every 10
minutes.
Setting will be saved to memory after LAST settings is
conrmed. Selecting “Cancel” at anytime will quit setup
routine. The main screen will display and restore settings
that have automatically been saved BEFORE beginning
“System Settings” cycle.
14
When you select “RUN,” the following sequence will begin:
RUN
Fluid’s Valve Motor will be ON for 15 seconds and
is waiting to detect end of the travel.
If valve is in the correct position and ready, it will con-
tinue to the next step.
Material will be transferred to the cart until:
Cart is full, or
Pump is running for 2 hours (time out)
Until there is no more material to transfer to the
cart.
If cart is completely empty, pump material until
3 minutes time-out or level is OK; it will con-
tinue the rest of the pumping routine.
There is a minimum level required in the cart in order to be able to heat and mix the material. Currently this
level is just below 1/4 of the cart. If the level is more than the minimum “Status” will display. If there is no
more resin to transfer and level in the cart is still too low, the system will display an error and it will be halted.
Goes ON and OFF in
Sync with Heater
RUN status screen:
Heater and Mixer will run with previously programmed parameters if there is minimum level of material in
the cart.
Current material temperature; minimum material level OK, cart full and programmed settings for Mixing and
Heating ON/OFF/IDLE will be displayed
Cart Status
Resin Temperature
15
System will periodically check the hardware and con-
nections to the cart and could result in the following
errors:
Errors
24V power supply out of range.
Emergency Stop Button is pressed.
Material level sensor is disconnected or non-operational.
Material thermistor is disconnected or non-operational.
Heater thermistor is disconnected or non-operational.
Not enough material in the cart after trying to pump material and timed out.
Valve motor is disconnected or non-operational.
16
MAINTENANCE
Before attempting to clean away any liquids or debris that may come into contact with the cart station, turn off the
power, unplug the Umbilical, and unplug the station’s power cord.
The Cart Station housing may be cleaned with a towel that has been dampened with detergent and water. How-
ever, the station is not water or air tight, so care must be taken to ensure no water or other uids enter through
the ventilation holes. Any aerosol, water, or paint sprays should be directed away from the station. Contact 3D
customer support if further cleaning is required.
Keep the Umbilical plug and connector clean.
When not in use, the Umbilical should be placed in the holder, to keep it out of the way.
Keep Umbilical connector away from liquids, grease, dirt, and dust.
17
SERVICE AND SUPPORT
For information, questions, or comments about your ProJet®3-D printer system(s), VisiJet® materials, or request ser-
vice, please contact a 3D Systems Customer Service or Sales Representative nearest you.
3D Systems
333 Three D Systems Circle
Rock Hill, SC 29730 USA
tel: 803.326.4080
fax: 803.324.8810
toll free: 800.889.2964
www.3dsystems.com
NYSE: DDD
• North & South America: [email protected]
• AsiaPacic: [email protected]
• Europe/Middle East/Africa: [email protected]
How to Order Parts
New and refurbished parts made by 3D System’s manufacturer are used when performing warranty repairs and
in building replacement parts and systems. Refurbished parts and systems, are parts or systems that have been
returned to 3D Systems, some of which were never used by a customer. All parts and systems are inspected and
tested for quality. Replacement parts and systems are covered for the remaining period of the limited warranty for
the product you bought. 3D Systems owns all parts removed from repaired products.
To order replacement parts, contact 3D Systems Customer Service Support or contact your local reseller.
When contacting 3D Systems Customer Service Support, have your serial number available to give to customer
support.
18
SPARE PARTS
VIEW 1
1
2
3
4
No. Part Number Description Qty.
1 19816-107-00 Scr, M6x1.0x20, Soc, Ss 2
2 2850-00511-100 Washer,M6 2
3 284667-00 Cbl Assy, Umbilical 1
4 284668-001 Umbilical Holder 1
1
19
SPARE PARTS
VIEW 2
1
2
3
4
No. Part Number Description Qty.
1 284382-00
Front Panel Label
1
2 20819-106-00
Switch,Emerg Stop,16Mm
1
3 283246-00
Label, Ring, E-Stop Button, 16MM ID, 43MM OD
1
4 284352-00
Push button, 18mm, SPDT, Momentary, Black
4
5
284661-00 Enclosure Cover
1
6
284670-00 Screen Shield
1
7
284351-00 LCD Kit, 4 X 20, Backlit, Ribbon Cable
1
8
282949-00 SCR, PHPH, M2.5 X 8, SS
4
9
284397-00 Loop Clamp, 1/2”, Nylon
1
10
201989-00 M4 NUT W/TOOTH
5
11
19816-136-00 SCR,M3X.5X8,SOC,SS
4
12
282259-00 HINGE
1
13
273349-00 WASHER, M3, 9mm OD, SS
4
14
18116-101-00 NUT,M3,.5,HEX,SS
4
7
5
6
8
9
10
11
12
13
14
20
SPARE PARTS
VIEW 3
1
2
3
4
No. Part Number Description Qty.
1 284366-00
EC Inlet C20, Front Side, QC Terminal, 16A, 250V
1
2 18115-101-00
Scr, M3x0.5x10, Flt, S, Zc
2
3
284367-00 Circuit Breaker, Thermal, 2P, 240V, 5A
1
4
284350-00
5
201989-00 M4 Nut W/Tooth
4
6
19816-136-00 Scr,M3x.5X8,Soc,Ss
10
7
284664-00 Thermal Pad
2
8
284358-00 Interface PCB Assembly
1
9
284663-00 Heatsink, PCB
1
10
284353-00 PS, Switching, 320W, 24V, 85-264VAC
1
11
284662-00 Hardware Panel
1
12
19816-101-00 Scr, M4x0.7x6, Soc, Ss
4
13
284669-00 Enclosure Box
1
7
5
6
8
6
9
10
11
12
13
7
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21

3D Systems 284107-00 User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI