Mayser SG-RSV 205 User manual

  • Hello! I am an AI chatbot trained to assist you with the Mayser SG-RSV 205 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Mayser Polymer Electric P.O. Box 3048 D-89020 Ulm Tel. +49 731 2061-0 Fax +49 731 2061-222
060902
Polymer Electric
Control Unit
Category 1 as per EN 954-1
for sensors with
1.2 k monitoring resistor
These operating instructions apply to
the following control units:
SG-RSV 205/2 Semiconductor
outputs
Control
This control unit contains two
monitoring circuits that act on two load
circuits.
The electronics monitor the resistance
of the connected sensors which have a
specific closed-circuit current.
The outputs are short circuit proof
semiconductor outputs.
Control Unit SG-RSV 205
Enclosure
W x H x D (mm) 58 x 30 x 30
Protection class enclosure IP 40
Plug connection
Flat plug 6,3 x 0,8
Weight c. 70 g
Operating Instructions
Sensor 1 Sensor 2
U
S
SG-RSV 205
Mayser Polymer Electric P.O. Box 3048 D-89020 Ulm Tel. +49 731 2061-0 Fax +49 731 2061-222
Polymer Electric
Subject to technical modifications.
Installation and Operation
Technical Data
Connecting Voltage U
S
SG-RSV 205 DC 18 - 32 V
Power consumption max. 2.5 W
Inputs
Input voltage U
E
0 - 16 V
Input current I
E
0 - 21 mA
Outputs (PNP)
Switching voltage U
A, high
min. U
S
- 1.0 V
U
A, low
max. 0.5 V
Switching current I
A
max. 0.4 A
Response time t
SG
< 5 ms
Permissible ambient temperature - 40 °C to + 80 °C
Important notes:
- if only one sensor is being used
When using only one sensor, bridge
the second input with a 1,2 k
resistor.
Installation
Fit all 7 flat plugs onto the appropriate
sockets and then insert them uniformly.
Connector assignment:
Supply voltage A1(+), A2 (–)
Semiconductor
outputs 1, 2
Sensor 1 Y1, Y2
Sensor 2 Y3, Y4
Commissioning
Following insertion of the SG-RSV 205
and connection of the connection
voltage U
S
:
Sensor not activated
- Output "Betätigt" (activated) (1) is off
(AUS)
- Output "Störung" (fault) (2) ist on
(EIN)
Sensor avtivated
- Output "Betätigt" (activated) (1) is on
(EIN)
- Output "Störung" (fault) (2) ist on
(EIN)
Cable disconnection or
interruption in connection voltage
- Output "Betätigt" (activated) (1) is off
(AUS)
- Output "Störung" (fault) (2) ist off
(AUS)
Other functions available on request.
Output behaviour
activated fault normalnormaloff
(1)
(2)
Output
"Betätigt"
(activated)
Output
"Störung"
(fault)
Model 205/2
normal
low
high
/