Velleman DVM171THD User manual

Category
Digital body thermometers
Type
User manual

Velleman DVM171THD accurately measures temperature and humidity with a broad measuring range from -40°C to +70°C and 0% to 100%RH. It features a large memory capacity that can store up to 32,000 readings, allowing for extensive data logging. The device is equipped with a dew point indication and a user-selectable alarm, providing real-time monitoring and notification capabilities. It offers flexible logging intervals ranging from 2 seconds to 24 hours, enabling customized data collection.

Velleman DVM171THD accurately measures temperature and humidity with a broad measuring range from -40°C to +70°C and 0% to 100%RH. It features a large memory capacity that can store up to 32,000 readings, allowing for extensive data logging. The device is equipped with a dew point indication and a user-selectable alarm, providing real-time monitoring and notification capabilities. It offers flexible logging intervals ranging from 2 seconds to 24 hours, enabling customized data collection.

DVM171THD
00 (30/06/2008)
3
User manual
1.1. Introduction
To all residents of the European Union
Important environmental information about this product
This symbol on the device or the package indicates that disposal of the
device after its lifecycle could harm the environment.
Do not dispose of the unit (or batteries) as unsorted municipal waste; it
should be taken to a specialized company for recycling.
This device should be returned to your distributor or to a local recycling
service. Respect the local environmental rules.
If in doubt, contact your local waste disposal authorities.
Thank you for choosing Velleman! Please read the manual thoroughly before bringing this
device into service. If the device was damaged in transit, don't install or use it and
contact your dealer.
1.2. Safety Instructions
Keep this device away from rain and moisture
.
Damage caused by disregard of certain guidelines in this manual is not covered by the
warranty and the dealer will not accept responsibility for any ensuing defects or
problems.
Keep the device away from splashing and dripping liquids.
Note that damage caused by user modifications to the device is not covered by the
warranty.
Keep the device away from children and unauthorised users.
1.3. General Guidelines
This device is battery-operated, using one 3.6V lithium battery AA).
Protect this device from shocks and abuse. Avoid brute force when operating the
device.
Protected the device against extreme heat (seeTechnical Specifications”), dust
and moisture.
Familiarise yourself with the functions of the device before actually using it.
All modifications of the device are forbidden for safety reasons.
Only use the device for its intended purpose. Using the device in an unauthorised way
will void the warranty.
DVM171THD
00 (30/06/2008)
4
1.4. Features
Memory for 32,000 readings (16,000 temperature and 16,000 humidity readings)
Dew point indication
Status Indication
USB Interface
User-Selectable Alarm
Analysis software
Multi-mode to start logging
Long battery life
Selectable measuring cycle: 2s, 5s, 10s, 30s, 1m, 5m, 10m, 30m, 1hr, 2hr, 3hr,
6hr, 12hr, 24hr
1.5. Use
First install the datalogger software on a personal computer, by inserting the enclosed
disc into the CD drive and following the instructions on the screen.
Remove the protective cover (1) from the datalogger, plug the datalogger into a free
USB-slot on the personal computer and start the datalogger software.
Set up the datalogger software and press the ‘Setup’ button. Refer to the help-
function of the datalogger software (‘Help’ ‘Help topics …’) for more information on
the use of the software and setup of the datalogger.
Remove the datalogger from the USB slot and replace the protective cover (1).
1. Protective cover
2. USB connector to PC port
3. Start button
4. RH and Temperature sensors
5. Alarm LED (red/yellow)
6. Record LED (green)
7. Mounting bracket
DVM171THD
00 (30/06/2008)
5
Place the device in a location where recording of ambient temperature and/or relative
humidity is required. Refer to the technical specifications for allowed operating
temperature range.
When the datalogger is set up to start manually (delayed start), the green LED (6) will
flash two times every 10 seconds. Press the Start button (3) until the green (6) and
yellow LED (5) flash once (together). The datalogger starts logging and the green LED
(6) will flash every 10 seconds (increase this value through the setup procedure to
increase battery life).
To download the data into the personal computer, start the datalogger software,
remove the protective cover (1) and plug the datalogger into a free USB-slot.
Refer to the help-function of the datalogger software (‘HelpHelp topics …’) for
more information on downloading and handling the data from the datalogger.
1.6. Troubleshooting
Both LEDs are off
Logging is not active or battery is low. Start logging or replace
battery
1x
Green REC LED (6), flashes 1x every 10 seconds
Logging, no alarm condition.
2x
Green REC LED (6), flashes 2x every 10 seconds
Delayed start mode,
1x
Red ALM LED (5), flashes 1x every 10 seconds
Logging, humidity lower limit exceeded.
2x
Red ALM LED (5), flashes 2x every 10 seconds
Logging, humidity upper limit exceeded.
1x
Red ALM LED (5), flashes 1x every 60 seconds
Low battery. Logging will stop, replace battery and download data.
1x
Yellow ALM LED (5), flashes 1x every 10 seconds
Logging, temperature lower limit exceeded.
2x
Yellow ALM LED (5), flashes 2x every 10 seconds
Logging, temperature higher limit exceeded.
1x
Yellow ALM LED (5), flashes 1x every 60 seconds
Logger memory full. Logging will stop, download data.
DVM171THD
00 (30/06/2008)
6
Note 1: in case of one alarm, the green REC LED (6) and the red or yellow ALM LED
(5) will blink alternately every 10 seconds. When two alarms occur, only the ALM
LED (5) will blink, showing alternately the first and second alarm every 10
seconds.
Note 2: when battery is low, all operations will be disabled automatically and memory
will be preserved.
1.7. Cleaning and storage
The humidity and temperature sensors (4) are very sensitive. Avoid dust, smoke and
other particles to enter the housing. Refer to paragraph “Sensor reconditioning
Wipe the datalogger regularly with a moist, lint-free cloth. Do not use alcohol or
solvents. Do not touch the USB connector.
Do not submerge the datalogger in water or any other liquid.
There are no user-serviceable parts.
Contact your dealer for spare parts if necessary.
1.8. Battery
To replace the battery, disconnect the device from the computer.
(1) Open the battery compartment by using a pointed object (e.g. small
screwdriver). Move the pointed object in the direction of the arrow.
(2) Gently pull the datalogger from the casing.
(3) Remove/insert the battery. Only use 3.6V Lithium batteries. Make sure the
polarity is as indicated in the casing. When the battery is inserted, the green and
yellow LEDs will flash alternately.
(4) Slide the datalogger back in the housing until it snaps into place. Configure the
datalogger using the enclosed software.
Note:
leaving the device in the USB port will reduce the battery life.
WARNING: handle Lithium batteries with care, observe warnings on
battery casing. Keep the battery away from children.
DVM171THD
00 (30/06/2008)
7
1.9. Sensor reconditioning
Over time, the internal sensor may become compromised as a result of pollutants,
chemical vapours or other environmental conditions. This can lead to inaccurate
readings. To recondition the internal sensors, use following procedure:
Heat the datalogger to +80°C (+176°F), humidity < 5% for 36 hours.
Keep the datalogger at+20~+30°C (+70~+90°F), humidity >74% for 48 hours
1.10. Technical Specification
relative humidity (RH) Overall range 0% ~ 100%
relative humidity accuracy 0~20%
20~40%
40~60%
60~80%
80~100%
±5.0%
±3.5%
±3.0%
±3.5%
±5.0%
temperature Overall range -40°C ~ +70°C (-40°F ~ +158°F)
temperature accuracy -40~-10°C (-10~+40°F)
-10~+40°C (+14~+104°F)
+40~+70°C (+104~+158°F)
±2°C (±3.6°F)
±1°C (±1.8°F)
±2°C (±3.6°F)
dew point temperature Overall range -40°C ~ +70°C (-40°F ~ +158°F)
dew point accuracy 25°C, 40~100% RH ±2.0°C (±4.0°F)
logging rate Selectable interval, 2sec ~ 24 hours
operating temperature -35°C ~ +80 °C (-31°F ~ +176°F)
battery type 3.6V Lithium AA)
dimensions 101 x 25 x 23 mm
weight 172 gr. (6 oz) (battery)
Use this device with original accessories only. Velleman nv cannot be held
responsible in the event of damage or injury resulted from (incorrect) use of
this device.
For more info concerning this product, please visit our website
www.velleman.eu.
The information in this manual is subject to change without prior notice.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27

Velleman DVM171THD User manual

Category
Digital body thermometers
Type
User manual

Velleman DVM171THD accurately measures temperature and humidity with a broad measuring range from -40°C to +70°C and 0% to 100%RH. It features a large memory capacity that can store up to 32,000 readings, allowing for extensive data logging. The device is equipped with a dew point indication and a user-selectable alarm, providing real-time monitoring and notification capabilities. It offers flexible logging intervals ranging from 2 seconds to 24 hours, enabling customized data collection.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI