STEP 6:
Lightly pull on the luminaire to verify
luminaire is securely mounted.
FIXTURE SERVICING AND
MAINTENANCE
STEP 1:
If supply wiring splices need to be inspected
or if luminaire needs to be removed, fully
loosen the (2) screws and rotate luminaire to
disengage from Mounting Plate.
STEP 2:
To re-install luminaire, when finished with
servicing or maintenance follow Step 2-6 in
“Junction Box Mounting” section above.
PENDANT MOUNTING (OPTIONAL)
STEP 1:
Attach Pendant Mount Plate to customer
supplied pendant kit.
NOTE: Not recommended for use with a
hang straight pendant. Cree does not provide
a counterbalance system.
STEP 2:
Feed customer supplied leads through
customer supplied pendant kit and the
Pendant Mount Plate. See Figure 5.
STEP 3:
For hands-free wiring locate the wireform
on luminaire and attach it to the clip on the
Pendant Mounting Plate. See Figure 5.
STEP 4:
Make wiring connections per “Electrical
Connections” section. Once wire
connections have been made remove
wireform on luminaire from the clip on the
mounting plate. Fold the wireform back
down onto the luminaire.
STEP 3:
Attach luminaire to the Pendant Mounting
Plate by pressing up on the luminaire until
the slots on the luminaire engage with the
clips on the Pendant Mounting Plate and
rotate until clips lock securely. To secure
install a minimum of (2) supplied screws
across from each other into the pendant
mounting plate clips on the underside of the
luminaire. See Figure 5.
NOTE: May require extra pressure on
luminaire to engage clips into slots. Only
apply pressure on housing body NOT on the
luminaire lens.
NOTE: If the pendant mounting plate clips
become deformed during installation,
slightly reopen the clips back up using a
screwdriver to ensure proper install of
luminaire.
LED LUMINAIRE MAINTENANCE
CLEANING INSTRUCTIONS:
Regular cleaning of the light LED luminaire
is required to keep the LED luminaire
operating optimal optical performance.
• Cleaning intervals to be no more than
twelve months for IESNA Clean category
environments and more frequently for
dirtier conditions.
• Care should be taken as to not damage
the lens and/or the interior reflective
surface as these components are critical
for optimal performance.
• Do not use any type of cleaners or stiff
brushes on the LED luminaire. Use
water with mild detergent and soft cloth.
ELECTRICAL CONNECTIONS
STEP 1:
Make the following Electrical Connections for products rated 120V, 277V,
or 347V (Line-Neutral), or rated 208V, or 240V (Line-Line):
a. For products rated 120V, 277V or 347V, connect the Black lead
from the luminaire to the LINE supply wiring inside the junction
box or for products rated 208V, or 240V, connect to the HOT 1
supply wiring.
b. For products rated 120V, 277V or 347V, connect the White lead
from the luminaire to the NEUTRAL supply wiring inside the
junction box or for products rated 208V, or 240V, connect to the
HOT 2 supply wiring.
c. Connect the Green or Green/Yellow lead from the luminaire to the
GROUND supply wiring inside the junction box.
LINE
OR HOT 1
GROUND
LINE-BLACK
GROUND-GREEN
NEUTRAL-WHITE
NEUTRAL
OR HOT 2
SUPPLY WIRING
LUMINAIRE
JUNCTION
BOX
5View of Underneath
Luminaire
(4) Pendant
Mounting
Plate Clips
Luminaire
Slots
(2) Screws
(4) Luminaire Slots
(4) Clips
Pendant
Mounting Plate
Wireform