D+H mt 40 Operating instructions

Type
Operating instructions
99.820.12 1.4/01/03
D+H Mechatronic AG • Georg-Sasse-Str. 28-32 • D-22949 Ammersbek • Tel. +4940-60565219 • Fax +4940-60565264
Instruction for use
Motor Tester MT40
Operation
Disconnect the motor from the central supply
system.
Set the current measuring range to suit the
maximum current expected.
Connect the measuring cable terminals to
the motor.
Polarity:
CLOSE operation : red = ( + ); black = ( - )
OPEN operation : red = ( - ); black = ( + )
Select the direction of drive / using the
rotary knob. After use the turn the unit back to
"Battery of".
Notes
The electronic protection responds to excess
current, over-discharging and short
circuiting. The red LED lights up.
Checking storage battery capacity:
Turn the left-hand rotary knob to “Batt.” .
Turn the right-hand rotary knob in direction
or .
The full measurement range corresponds
to a voltage of 20 - 30V.
Battery charged : > 26 V
Battery discharged : < 22 V
If the battery capacity is low, the over
discharging protection could respond.
Recharge for 14 hours using the charging
unit supplied. The green charging control
LED lights up.
Protection response in the event of excess
current or short-circuiting:
If the unit's output current exceeds 3A, the
electronic protection is triggered.
The drives must not be in
operation during the charging
process with connected
charging set.
Danger of destruction!
ATTENTION!
Charge storage batterie 14
hours using enclosed charging
set before initial operation!
Full capacity of the storage
battery is developed only after several charge
and discharge actions.
Special Information
- 3 current measuring ranges
- Powerfull 24V NiCd storage battery
- Storage battery capacity display 20-30 V
- Electronic, self-resetting protection by
means of power MOSFET for excess
current, over-discharging and short-
circuiting with LED display.
- Highly resilient silicon power cable
- Carrying strap and low weight make it easy
to use.
Application
On-the spot function check on any kind of 24
VDC motor up to 2A.
For testing, adjusting, initial operation and
maintenance. Can register safe operation,
shutdown reserve and overload.
Technical Data
Battery : 24 V / 0,6 Ah NiCd
Battery display : 20 - 30 V
Current measuring range : 0,5 - 1 - 2 A
Over-current protection : 3 A
Over-discharge shutdown : 20 V
Charging time : 14 hours
Dimensions (wxhxd) : 160 x 70 x 85 mm