- 14 -
Error Messages & Problems
a If you are trying to load or operate the IRL-5000 make certain that the IRL-3000’s ADA/
RS-232 button is in the right position (Down for PC oriented functions, Up for ADA Bus
control).
b Make certain that correct com port is set in the Progada.ini file.
c If you are receiving error messages of any type and your connections are in the proper
place, you may need to synchronize the software and IRL-5000 hardware. To do so,
switch the ADA Keypad Display software between ADA Mode and Program Mode.
Select either ADA Mode or Program Mode from the Options pull down window. Flip
back and forth between these two modes a few times to synchronize software and
hardware.
Connection of the IRL-5000 to the Suite 16
In addition to the ADA Bus connections
on between the IRL-5000 and the ADA
system, you will also wish to connect
the 9-pin ribbon cable that triggers the
ON and OFF functions. This cable may
also be running to ACC-48 Source AC
controllers that connect and disconnect
AC from components when they are not
being used. The diagram shows a six-
teen source system. Here two IRL-
5000’s are employed, one set to ad-
dress 1 for sources 1-8 and the second
to address 2 for sources 9-16.
If you are using the On and Off func-
tions with ACC-48s, you may wish to
apply a 3000ms (3 seconds) to 5000ms
(5 seconds) delay prior to the ON func-
tion (see Macros). This will permit the
unit to turn on (get AC) prior to the trans-
mission of the IR command.
When using ACC-48s, the OFF function
may be rendered useless as the ACC-
48 will remove power to the unit while
the unit is receiving the OFF IR com-
mand. For components that require an
OFF function, do not use an ACC-48.
1/2 ASB
115V~
1/4 ASB
230V~
115V~/60Hz • 230V~/50Hz
500 WATTS MAX
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
230V
115V
1 Gnd
2 Fdbk
3 Cntrl
4 +V
ADA Bus®
Network Control I/O
Main
AC
Input
Switch
AC
(10A)
WARNING! Risk Of Hazardous Energy!
Make Proper Connections.
AVERTISSEMENT! Energie Electrique
Dangereuse!
Faire Des Connexions Propres
Pour L'Hautparleur.
Voir La Notice De Fonctionnement.
CAUTION: Disconnect Supply
Cord Before Servicing.
ATTENTION: Debrancher
Avant Le Depannage.
AVP-16 MR Controller
115 V
1
L
R
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
P-16
P-16 • Preamplifier Module
Zones 1- 6 & 7-12
+12VDC Outputs
Gnd
Zones 13-16
+12VDC Output
Gnd
(-)
13
(+)
14
(+)
15
(+)
16
(+)
In 1/7
In 2/8
In 5/11
In 6/12
TO PTM-1225/1260
Zones 1-6
Zones 7-12
In 4/10
In 3/9
VIDEO INPUTS
EXPANSION PORTS
1 3 5 7 9111315
2 4 6 8 10 12 14 16
13579111315
2468101214
16
V-16
V-16 • Video I/O Module
Output Triggers
Input Triggers
+12VDC Outputs
Gnd
Out 8/16
Programmed Video
Input Triggers
5-24V AC•DC
Gnd
(+)
1
(+)
2
(+)
3
(+)
4
(+)
Out 1/9
Out 2/10
Out 5/13
Out 6/14
Out 1-8
Out 9-16
Out 7/15
Out 4/12
Out 3/11
1
L
R
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
A-16
A-16 • Audio Input Module
Input Triggers
Paging Input/Trigger
+12VDC Outputs
Gnd
In 8/16
Balanced
Audio Page
Input (600Ω)
Trig ger
5-24V
AC•DC
1
Com
2
(+)
3
(-)
4
(+)
5
(-)
In 1/9
In 2/10
In 5/13
In 6/14
In 1-8
In 9-16
In 7/15
In 4/12
In 3/11
1 2 3 4
ADA Bus®
Gnd Rx Tx +15V
RS-232
Pins
2=Tx
3=Rx
5=Com
RS-232
ADA Bus
ADA/232
Power On/Off IR Macro
Connect To Mainframe
Source DC Triggers &
ACC-48 AC Controllers
IRL-5000
Source Controller
12345678Source Ports:
Data/Carrier
IR Flasher=Remove Jumper
Serial Direct=Insert Jumper
40KHz IR Repeat
Frequency
IR Repeating Only
1
Repeater
IR - Serial
Serial
Data Only
Off
PGM DEL
CON ERR
Norm Invert
2
3
4
5
6
7
8
Repeater
IR - Serial
Serial
Data Only
Off
Norm Invert
Repeater
IR - Serial
Serial
Data Only
Off
Norm Invert
Repeater
IR - Serial
Serial
Data Only
Off
Norm Invert
Repeater
IR - Serial
Serial
Data Only
Off
Norm Invert
Repeater
IR - Serial
Serial
Data Only
Off
Norm Invert
Repeater
IR - Serial
Serial
Data Only
Off
Norm Invert
Repeater
IR - Serial
Serial
Data Only
Off
Norm Invert
12345678
TO 9 PIN "D"
DELTA-88123456781234567812345678
1000 WATTS
MAX TOTAL
Set Shunting Pins To Engage AC With Zone Or Source Numbers 1-8
120-240 VAC
50-60 Hz
QUAD AC CONTROLLER
ACC-48
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
1. Delta-88 9 Pin "D" programmed for source AC control. - Set one shunting
pin per AC outlet according to source inputs. Set 3 pins for MT-3000.
2. Delta-88 9 Pin "D" programmed for zone AC control. - Set one shunting
pen per AC outlet according to zone numbers. Set all shunting pins on
one AC Outlet for All-On source AC control when not using an ACC-3000.
3421
12345678
TO 9 PIN "D"
DELTA-88123456781234567812345678
1000 WATTS
MAX TOTAL
Set Shunting Pins To Engage AC With Zone Or Source Numbers 1-8
120-240 VAC
50-60 Hz
QUAD AC CONTROLLER
ACC-48
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
1. Delta-88 9 Pin "D" programmed for source AC control. - Set one shunting
pin per AC outlet according to source inputs. Set 3 pins for MT-3000.
2. Delta-88 9 Pin "D" programmed for zone AC control. - Set one shunting
pen per AC outlet according to zone numbers. Set all shunting pins on
one AC Outlet for All-On source AC control when not using an ACC-3000.
3421
1 2 3 4
ADA Bus®
Gnd Rx Tx +15V
RS-232
Pins
2=Tx
3=Rx
5=Com
RS-232
ADA Bus
ADA/232
Power On/Off IR Macro
Connect To Mainframe
Source DC Triggers &
ACC-48 AC Controllers
IRL-5000
Source Controller
12345678Source Ports:
Data/Carrier
IR Flasher=Remove Jumper
Serial Direct=Insert Jumper
40KHz IR Repeat
Frequency
IR Repeating Only
1
Repeater
IR - Serial
Serial
Data Only
Off
PGM DEL
CON ERR
Norm Invert
2
3
4
5
6
7
8
Repeater
IR - Serial
Serial
Data Only
Off
Norm Invert
Repeater
IR - Serial
Serial
Data Only
Off
Norm Invert
Repeater
IR - Serial
Serial
Data Only
Off
Norm Invert
Repeater
IR - Serial
Serial
Data Only
Off
Norm Invert
Repeater
IR - Serial
Serial
Data Only
Off
Norm Invert
Repeater
IR - Serial
Serial
Data Only
Off
Norm Invert
Repeater
IR - Serial
Serial
Data Only
Off
Norm Invert
12345678
TO 9 PIN "D"
DELTA-88123456781234567812345678
1000 WATTS
MAX TOTAL
Set Shunting Pins To Engage AC With Zone Or Source Numbers 1-8
120-240 VAC
50-60 Hz
QUAD AC CONTROLLER
ACC-48
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
1. Delta-88 9 Pin "D" programmed for source AC control. - Set one shunting
pin per AC outlet according to source inputs. Set 3 pins for MT-3000.
2. Delta-88 9 Pin "D" programmed for zone AC control. - Set one shunting
pen per AC outlet according to zone numbers. Set all shunting pins on
one AC Outlet for All-On source AC control when not using an ACC-3000.
3421
12345678
TO 9 PIN "D"
DELTA-88123456781234567812345678
1000 WATTS
MAX TOTAL
Set Shunting Pins To Engage AC With Zone Or Source Numbers 1-8
120-240 VAC
50-60 Hz
QUAD AC CONTROLLER
ACC-48
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
1. Delta-88 9 Pin "D" programmed for source AC control. - Set one shunting
pin per AC outlet according to source inputs. Set 3 pins for MT-3000.
2. Delta-88 9 Pin "D" programmed for zone AC control. - Set one shunting
pen per AC outlet according to zone numbers. Set all shunting pins on
one AC Outlet for All-On source AC control when not using an ACC-3000.
3421
Sources 1-8
AC Switching
& IR Control
IRL-5000
Address 1
IRL-5000
Address 2
Sources 9-16
AC Switching
& IR Control