1. General information
These service instructions describe how to change oil in KPL
axial-flow propeller pumps and KWM mixed-flow impeller pumps
installed in column pipes with diameters from DN 700 to 1400.
For instructions on how to change oil in KPL and KWM pumps
with column pipe diameters from DN 500 to 650 or for more
general service instructions, see the KPL, KWM service
instructions, product number 98383809, available in the Grundfos
Product Center on Grundfos' homepage, www.grundfos.com.
1.1 Symbols used in this document
2. Safety
1. General information
2
1.1 Symbols used in this document
2
2. Safety
2
3. Oil service kit, KPL.700-800 and KWM.700-800
3
3.1 Assembling the oil pipe
3
3.2 Draining the oil
5
3.3 Filling oil
6
3.4 Checking the oil level
7
4. Oil service kit, KPL.900-1400 and KWM.900-1400
9
4.1 Assembling the oil pipe
9
4.2 Draining the oil
10
4.3 Filling oil
11
4.4 Checking the oil level
12
5. Oil quantity
12
5.1 Oil quantity according to column pipe diameter
12
Warning
If these safety instructions are not observed,
it may result in personal injury.
Warning
During electrical installation, make sure that the
power supply cannot be accidentally switched
on.
Warning
These instructions must be observed for
explosion-proof pumps. We recommend that you
also follow these instructions for standard
pumps.
Caution
If these safety instructions are not observed, it
may result in malfunction or damage to the
equipment.
Note
Notes or instructions that make the job easier
and ensure safe operation.
Warning
Make sure that the mains switch can be locked in
the 0/Off position. Type and requirements must
comply with EN 60204-1, 5.3.2.
Warning
Observe local regulations setting limits for
manual lifting or handling.
Warning
For safety reasons, all work in pump pits must be
supervised by a person outside the pit.
Warning
Pits for submersible wastewater pumps contain
wastewater potentially with toxic and/or
disease-causing substances.
Therefore, while working on the pump, wear
appropriate personal protective equipment and
clothing. In addition, carry out work on or near
the pump under strict observance of the hygiene
regulations in force.
English (GB)
3
3. Oil service kit, KPL.700-800 and KWM.700-800
3.1 Assembling the oil pipe
Fig. 1 Oil service kit, KPL.700-800 and KWM.700-800
Where nothing else is indicated, the position numbers refer to fig.
1 and/or the figure below each step.
1. Connect the handle (pos. 24) to the rod (pos. 12).
2. Connect the intermediate pipe (pos. 10) to the barrel nipple
(pos. 16).
3. Connect the handle with rod (pos. A and step 1) to the
intermediate pipe with barrel nipple (pos. B and step 2).
4. Connect the handle with rod and the intermediate pipe with
barrel nipple (pos. C) to the intermediate pipe (pos. 11).
5. Connect the isolating valve (pos. 2) to the three-way tee fitting
(pos. 14).
6. Connect the isolating valve (pos. 17) to the barrel nipple (pos.
7).
7. Connect the isolating valve with barrel nipple (pos. F and step
6) to the isolating valve with three-way tee fitting (pos. E and
step 5).
TM06 3181 5014
Pos. Description
1Air hose
2 Isolating valve
3 Isolating valve
4 Intermediate fitting
5 Hexagon key
6 Hexagon key
7 Barrel nipple
8 Hexagon key
9 Barrel nipple
10 Intermediate pipe
11 Intermediate pipe
12 Rod
13 Funnel
14 Three-way tee fitting
15 Elbow fitting
16 Barrel nipple
17 Isolating valve
18 Handle
19 Plug
20 Intermediate fittings
21 Stub
22 Stub
23 Air pump
24 Handle
25 Air plug
13
14
15
16
17
18
19
20
21
22
23
24
25
1
2
3
4
5
6
7
8
9
10
11
12
TM06 3182 5014TM06 3183 5014TM06 3184 5014TM06 3185 5014TM06 3186 5014TM06 3187 5014TM06 3188 5014
24 12
10 16
A
B
11
C
214
17 7
F
E
English (GB)
4
8. Connect the handle with rod, the intermediate pipe with barrel
nipple and intermediate pipe (pos. D and step 4) to the
isolating valve with barrel nipple and three-way tee fitting
(pos. G and step 7).
9. Connect the plug (pos. 19).
The oil pipe is now completely assembled. See fig. 2.
Fig. 2 Assembled oil pipe, column pipe diameters DN
700-800
TM06 3189 5014TM06 3190 5014TM06 3191 5014
D
G
19
H
English (GB)
5
3.2 Draining the oil
Fig. 3 Sectional view, KPL.700-800 and KWM.700-800
1. Remove all the plugs (pos. 26, 27, 28 and 29).
Fig. 4 Draining oil, KPL.700-800, KWM.700-800
Where nothing else is indicated, the position numbers refer to fig.
4 and/or the figure below each step.
2. Completely loosen the handle (pos. 24).
3. Close the isolating valves (pos. 17 and 31).
4. Insert the assembled oil pipe (pos. 35) in the lower oil plug
space (pos. 33).
5. Connect the intermediate fitting (fig. 1, pos. 20) to the air plug
(fig. 1, pos. 25).
6. Connect the stub (fig 1, pos. 21) to the intermediate fitting with
air plug (step 5). Fit the assembled component in the upper oil
plug space (pos. 32). See fig. 4.
7. Connect the stub (fig. 1, pos. 22) to the air pump (pos. 23).
8. Fit the air hose (pos. 1) between the air pump with stub (step
7) and the assembled stub, intermediate fitting and air plug
(step 6) fitted in the upper plug space (pos. 32).
9. Open the isolating valve (pos. 31).
10. Slowly tighten the handle (pos. 24) until the oil starts to flow.
11. Connect the air pump (pos. 23) to the power supply.
12. Drain the oil into an appropriate waste disposal container.
13. When the oil has been drained, disconnect the air pump (pos.
23) from the power supply.
14. Remove the assembled oil pipe (pos. 35) and the plug fitted in
the upper oil plug space (pos. 32).
TM06 3192 5014
Pos. Description
26 Upper casing plug
27 Lower casing plug
28 Upper oil plug
29 Lower oil plug
30 Non-return valve
TM06 3193 5014
Pos. Description
1Air hose
17 Isolating valve
23 Air pump
24 Handle
31 Isolating valve
32 Upper oil plug space
33 Lower oil plug space
34 Non-return valve
35 Assembled oil pipe
28
26
27
29
30
1
24
17
31
35
34
33
23
32
Waste
oil
TM06 3194 5014TM06 3195 5014TM06 3196 5014TM06 3197 5014
Note
Dispose of used oil in accordance with local
regulations.
2520
21
22
23
1
English (GB)
6
3.3 Filling oil
Fig. 5 Filling oil, KPL.700-800, KWM.700-800
Where nothing else is indicated, the position numbers refer to fig.
5 and/or the figure below each step.
1. Disconnect the rod (fig. 1, pos. 12) from the handle (pos. 24).
2. Connect the handle (pos. 24) to the assembled oil pipe (pos.
35).
3. Disconnect the plug (fig. 1, pos. 19) from the four-way tee
fitting on the assembled oil pipe (pos. 35).
4. Connect the funnel (pos. 13) to the intermediate fitting (fig. 1,
pos. 4).
5. Connect the assembled funnel and fitting to the assembled oil
pipe (pos. 35).
6. Fit the assembled funnel, fitting and oil pipe (pos. 35) in the
upper casing plug space (pos. 36). See fig. 5.
7. Close the isolating valves (pos. 17 and 31).
8. Pour the recommended quantity of oil through the funnel (pos.
13). See section 5. Oil quantity.
9. After completing the oil filling, disconnect the assembled oil
pipe (pos. 35).
10. Refit the plugs (fig. 3, pos. 26 to 29).
TM06 3198 5014
Pos. Description
13 Funnel
17 Isolating valve
24 Handle
31 Isolating valve
32 Upper oil plug space
34 Non-return valve
35 Assembled oil pipe
36 Upper casing plug space
TM06 3199 5014TM06 3200 5014TM06 3201 5014
13
24
34
32
17
31
35
36
24 12
24 35
19
35
TM06 3202 5014TM06 3203 5014
Note
The non-return valve (pos. 34) prevents oil from
leaking.
Note
The air inside the oil chamber escapes through
the upper oil plug space (pos. 32) due to the
difference in diameter.
13 4
English (GB)
7
3.4 Checking the oil level
Fig. 6 Checking the oil level, KPL.700-800, KWM.700-800
Where nothing else is indicated, the position numbers refer to fig.
6 and/or the figure below each step.
1. Connect the handle (pos. 24) to the rod (fig. 1, pos. 12).
2. Connect the handle (pos. 24) with rod (fig. 1, pos. 12) to the
assembled oil pipe (pos. 35).
3. Remove the funnel (fig. 1, pos. 13) with intermediate fitting
(fig. 1, pos. 4) from the assembled oil pipe (pos. 35).
4. Connect the plug (pos. 19) to the four-way tee fitting on the
assembled oil pipe (pos. 35).
TM06 3204 5014
Pos. Description
9 Intermediate fitting
15 Elbow fitting
17 Isolating valve
19 Plug
24 Handle
31 Isolating valve
33 Lower oil plug space
34 Non-return valve
35 Assembled oil pipe
37 Isolating valve
38 Sight glass
37
38
24 19 33
35 34
17
9
15
31
A
A
TM06 3205 5014TM06 3206 5014TM06 3207 5014TM06 3208 5014
24 12
35
13
35
19
English (GB)
8
5. Connect the elbow fitting (pos.15) to the intermediate fitting
(pos. 9).
6. Connect the sight glass (pos. 38) with isolating valve (fig. 1,
pos. 3) to the elbow fitting (pos. 15) with intermediate fitting
(pos. 9 and step 5).
7. Connect the sight glass (pos. 38) with isolating valve (fig. 1,
pos. 3) and fittings (pos. 15 and 9) to the isolating valve (pos.
17).
8. Completely loosen the handle (pos. 24).
9. Close the isolating valve (pos. 31). Fit the assembled oil pipe
(pos. 35) in the lower oil plug space (pos. 33). See fig. 6.
10. Open the isolating valves (pos. 17 and 37).
11. Slowly fasten the handle (pos. 24) until the oil level is visible
in the sight glass (pos. 38).
12. Wait until the oil level has stabilised.
13. Check the oil level marked "MIN" according to the pipe column
diameter. See fig. 6, detail A.
14. After the oil level check, loosen the handle (pos. 24) to close
the non-return valve (pos. 34).
15. Open the isolating valve (pos. 31), and drain the remaining oil
from the sight glass (pos. 38) into an appropriate waste
disposal container.
16. Disassemble the oil pipe and place it in the suitcase (fig. 1) for
storage.
17. Fit oil and casing plugs (fig. 3, pos. 26-29).
TM06 3209 5014TM06 3210 5014TM06 3211 5014
Note
Handle the sight glass (pos. 38) with care.
15 9
3
English (GB)
9
4. Oil service kit, KPL.900-1400 and
KWM.900-1400
4.1 Assembling the oil pipe
Fig. 7 Oil service kit, KPL.900-1400 and KWM.900-1400
Where nothing else is indicated, the position numbers refer to fig.
7 and/or the figure below each step.
1. Connect the handle (pos. 18) to the rod (pos. 9).
2. Connect the intermediate pipe (pos. 8) to the oil pipe (pos.
12).
3. Connect the handle with rod (pos. A and step 1) to the
intermediate pipe with oil pipe (pos. B and step 2).
4. Connect the isolating valve (pos. 3) to the intermediate pipe
(pos. 10).
5. Connect the handle with rod and the intermediate pipe with oil
pipe (pos. C and step 3) to the assembled isolating valve and
intermediate pipe (pos. D and step 4).
6. Connect the plug (pos. 14) to the assembled handle, rod,
intermediate pipe, oil pipe, isolating valve and intermediate
pipe (pos. E and step 5).
The oil pipe is now completely assembled. See fig. 8.
Fig. 8 Assembled oil pipe, KPL.900-1400, KWM.900-1400
TM06 3212 5014
Pos. Description
1Air hose
2 Sight glass with fittings
3 Isolating valve
4 Hexagon key
5 Intermediate fitting
6 Hexagon key
7 Hexagon key
8 Intermediate pipe
9Rod
10 Intermediate pipe
11 Funnel
12 Oil pipe
13 Handle
14 Plug
15 Intermediate fitting
16 Stub
17 Stub
18 Handle
19 Air plug
20 Air pump
11
12
13
14
15
16
17
18
19
20
1
2
3
4
5
6
7
8
9
10
TM06 3213 5014TM06 3214 5014TM06 3215 5014TM06 3216 5014TM06 3217 5014TM06 3218 5014TM06 3219 5014
18
9
812
A
B
310
C
D
E14
English (GB)
10
4.2 Draining the oil
Fig. 9 Sectional view, KPL.900-1400 and KWM.900-1400
1. Remove all the plugs (pos. 21, 22, 23 and 24).
Fig. 10 Draining oil, KPL.900-1400, KWM.900-1400
Where nothing else is indicated, the position numbers refer to fig.
10 and/or the figure below each step.
2. Completely loosen the handle (pos. 18).
3. Close the isolating valve (pos. 26).
4. Insert the assembled oil pipe (pos. 27) in the lower oil plug
space (pos. 29).
5. Connect the intermediate fitting (fig. 7, pos. 15) to the air plug
(fig. 7, pos. 19).
6. Connect the stub (fig. 7, pos. 16) to the intermediate fitting
with air plug (step 5). Fit the assembled component in the
upper oil plug space (pos. 28). See fig. 10.
7. Connect the stub (fig. 7, pos. 17) to the air pump (pos. 20).
8. Fit the air hose (pos. 1) between the air pump with stub (step
7) and the assembled stub, intermediate fitting and air plug
(step 6), fitted in the upper oil plug space (pos. 28). See fig.
10.
9. Open the isolating valve (pos. 26).
10. Slowly tighten the handle (pos. 18) until the oil starts to flow.
Make sure that the non-return valve (pos. 25) has been
activated when resistance is met.
11. Connect the air pump (pos. 20) to the power supply.
12. Drain the oil into an appropriate waste disposal container.
13. When the oil has been drained, disconnect the air pump (pos.
20) from the power supply.
14. Remove the assembled oil pipe (pos. 27) and the plug fitted in
the upper oil plug space (pos. 28).
TM06 3220 5014
Pos. Description
21 Upper casing plug
22 Lower casing plug
23 Upper oil plug
24 Lower oil plug
25 Non-return valve
TM06 3221 5014
Pos. Description
1Air hose
18 Handle
20 Air pump
25 Non-return valve
26 Isolating valve
27 Assembled oil pipe
28 Upper oil plug space
29 Lower oil plug space
21
23
24
25
22
20 1
28
25
2927
26
18
TM06 3222 5014TM06 3223 5014TM06 3224 5014TM06 3225 5014
1915
16
17
20
1
English (GB)
11
4.3 Filling oil
Fig. 11 Filling oil, KPL.900-1400, KWM.900-1400
Where nothing else is indicated, the position numbers refer to fig.
11 and/or the figure below each step.
1. Disconnect the rod (fig. 7, pos. 9) from the handle (pos. 18).
2. Connect the handle (pos. 18) to the assembled oil pipe (pos.
27).
3. Disconnect the plug (fig. 7, pos. 14) from the four-way tee
fitting on the assembled oil pipe (pos. 27).
4. Connect the funnel (pos. 11) to the intermediate fitting (pos.
5).
5. Connect the assembled funnel and fitting to the assembled oil
pipe (pos. 27).
6. Fit the assembled funnel, fitting and oil pipe in the upper
casing plug space (pos. 30). See fig. 11.
7. Close the isolating valve (pos. 26).
8. Pour the recommended quantity of oil through the funnel (pos.
11). See section 5. Oil quantity.
9. After completing the oil filling, disconnect the assembled oil
pipe (pos. 27).
10. Refit the plugs (fig. 9, pos. 21 to 24).
TM06 3226 5014
Pos. Description
5 Intermediate fitting
11 Funnel
18 Handle
25 Non-return valve
26 Isolating valve
27 Assembled oil pipe
28 Upper oil plug space
30 Upper casing plug space
TM06 3227 5014TM06 3228 5014TM06 3229 5014
11
5
18
26
27
30
28
25
18
9
18
27
14
27
TM06 3230 5014TM06 3231 5014
Note
The non-return valve (pos. 25) prevents oil from
leaking.
Note
The air inside the oil chamber escapes through
the upper oil plug space (pos. 28) due to the
difference in diameter.
11 5
English (GB)
12
4.4 Checking the oil level
Fig. 12 Checking the oil level, KPL.900-1400, KWM.900-1400
Where nothing else is indicated, the position numbers refer to fig.
12 and/or the figure below each step.
1. Connect the handle (pos.18) to the rod (fig. 7, pos. 9).
2. Connect the handle (pos. 18) with rod (fig. 7, pos. 9) to the
assembled oil pipe (pos. 27).
3. Remove the funnel (fig. 7, pos. 11) with intermediate fitting
(fig. 7, pos. 5) from the assembled oil pipe (pos. 27).
4. Connect the sight glass with fittings (fig. 7, pos. 2) to the
four-way tee fitting on the assembled oil pipe (pos. 27).
5. Completely loosen the handle (pos. 18).
6. Close the lower isolating valve (pos. 26).
7. Fit the assembled oil pipe (step 4) in the lower oil plug space
(pos. 29). See fig. 12.
8. Open the upper isolating valve (pos. 31).
9. Slowly fasten the handle (pos. 18) until the oil level is visible
in the sight glass (pos. 32).
10. Wait until the oil level has stabilised.
11. Check the oil level marked "MIN" according to the pipe column
diameter. See fig. 12, detail A.
12. After the oil level check, loosen the handle (pos. 18) to close
the non-return valve (pos. 25).
13. Open the isolating valves (pos. 26 and 31) and drain the
remaining oil from the sight glass (pos. 32) into an appropriate
waste disposal container.
14. Disassemble the oil pipe and place it in the suitcase (fig.7) for
storage.
15. Fit oil and casing plugs (fig. 9, pos. 21-24).
5. Oil quantity
5.1 Oil quantity according to column pipe diameter
Subject to alterations.
TM06 3232 5014
Pos. Description
18 Handle
25 Non-return valve
26 Isolating valve
27 Assembled oil pipe
29 Lower oil plug space
31 Isolating valve
32 Sight glass with fittings
TM06 3233 5014TM06 3234 5014TM06 3235 5014
A
A
31
18
26
27
29
25
32
18
9
27
11
5
TM06 3236 5014
Note
Handle the sight glass (pos. 32) with care.
Column pipe diameter
[DN]
Quantity of oil
[l]
700 6
800 6
900 12
1000 13
1200 24
1400 34
2
Grundfos companies
Argentina
Bombas GRUNDFOS de Argentina S.A.
Ruta Panamericana km. 37.500 Centro
Industrial Garin
1619 Garín Pcia. de B.A.
Phone: +54-3327 414 444
Telefax: +54-3327 45 3190
Australia
GRUNDFOS Pumps Pty. Ltd.
P.O. Box 2040
Regency Park
South Australia 5942
Phone: +61-8-8461-4611
Telefax: +61-8-8340 0155
Austria
GRUNDFOS Pumpen Vertrieb Ges.m.b.H.
Grundfosstraße 2
A-5082 Grödig/Salzburg
Tel.: +43-6246-883-0
Telefax: +43-6246-883-30
Belgium
N.V. GRUNDFOS Bellux S.A.
Boomsesteenweg 81-83
B-2630 Aartselaar
Tél.: +32-3-870 7300
Télécopie: +32-3-870 7301
Belarus
Представительство ГРУНДФОС в
Минске
220125, Минск
ул. Шафарнянская, 11, оф. 56, БЦ
«Порт»
Тел.: +7 (375 17) 286 39 72/73
Факс: +7 (375 17) 286 39 71
E-mail: minsk@grundfos.com
Bosna and Herzegovina
GRUNDFOS Sarajevo
Zmaja od Bosne 7-7A,
BH-71000 Sarajevo
Phone: +387 33 592 480
Telefax: +387 33 590 465
www.ba.grundfos.com
e-mail: grun[email protected]
Brazil
BOMBAS GRUNDFOS DO BRASIL
Av. Humberto de Alencar Castelo Branco,
630
CEP 09850 - 300
São Bernardo do Campo - SP
Phone: +55-11 4393 5533
Telefax: +55-11 4343 5015
Bulgaria
Grundfos Bulgaria EOOD
Slatina District
Iztochna Tangenta street no. 100
BG - 1592 Sofia
Tel. +359 2 49 22 200
Fax. +359 2 49 22 201
email: bulgaria@grundfos.bg
Canada
GRUNDFOS Canada Inc.
2941 Brighton Road
Oakville, Ontario
L6H 6C9
Phone: +1-905 829 9533
Telefax: +1-905 829 9512
China
GRUNDFOS Pumps (Shanghai) Co. Ltd.
10F The Hub, No. 33 Suhong Road
Minhang District
Shanghai 201106
PRC
Phone: +86 21 612 252 22
Telefax: +86 21 612 253 33
Croatia
GRUNDFOS CROATIA d.o.o.
Buzinski prilaz 38, Buzin
HR-10010 Zagreb
Phone: +385 1 6595 400
Telefax: +385 1 6595 499
www.hr.grundfos.com
Czech Republic
GRUNDFOS s.r.o.
Čajkovského 21
779 00 Olomouc
Phone: +420-585-716 111
Telefax: +420-585-716 299
Denmark
GRUNDFOS DK A/S
Martin Bachs Vej 3
DK-8850 Bjerringbro
Tlf.: +45-87 50 50 50
Telefax: +45-87 50 51 51
www.grundfos.com/DK
Estonia
GRUNDFOS Pumps Eesti OÜ
Peterburi tee 92G
11415 Tallinn
Tel: + 372 606 1690
Fax: + 372 606 1691
Finland
OY GRUNDFOS Pumput AB
Mestarintie 11
FIN-01730 Vantaa
Phone: +358-(0)207 889 900
Telefax: +358-(0)207 889 550
France
Pompes GRUNDFOS Distribution S.A.
Parc d’Activités de Chesnes
57, rue de Malacombe
F-38290 St. Quentin Fallavier (Lyon)
Tél.: +33-4 74 82 15 15
Télécopie: +33-4 74 94 10 51
Germany
GRUNDFOS GMBH
Schlüterstr. 33
40699 Erkrath
Tel.: +49-(0) 211 929 69-0
Telefax: +49-(0) 211 929 69-3799
e-mail: infoservice@grundfos.de
Service in Deutschland:
e-mail: kundendienst@grundfos.de
HILGE GmbH & Co. KG
Hilgestrasse 37-47
55292 Bodenheim/Rhein
Germany
Tel.: +49 6135 75-0
Telefax: +49 6135 1737
e-mail: hilg[email protected]
Greece
GRUNDFOS Hellas A.E.B.E.
20th km. Athinon-Markopoulou Av.
P.O. B o x 7 1
GR-19002 Peania
Phone: +0030-210-66 83 400
Telefax: +0030-210-66 46 273
Hong Kong
GRUNDFOS Pumps (Hong Kong) Ltd.
Unit 1, Ground floor
Siu Wai Industrial Centre
29-33 Wing Hong Street &
68 King Lam Street, Cheung Sha Wan
Kowloon
Phone: +852-27861706 / 27861741
Telefax: +852-27858664
Hungary
GRUNDFOS Hungária Kft.
Park u. 8
H-2045 Törökbálint,
Phone: +36-23 511 110
Telefax: +36-23 511 111
India
GRUNDFOS Pumps India Private Limited
118 Old Mahabalipuram Road
Thoraipakkam
Chennai 600 096
Phone: +91-44 2496 6800
Indonesia
PT. GRUNDFOS POMPA
Graha Intirub Lt. 2 & 3
Jln. Cililitan Besar No.454. Makasar,
Jakarta Timur
ID-Jakarta 13650
Phone: +62 21-469-51900
Telefax: +62 21-460 6910 / 460 6901
Ireland
GRUNDFOS (Ireland) Ltd.
Unit A, Merrywell Business Park
Ballymount Road Lower
Dublin 12
Phone: +353-1-4089 800
Telefax: +353-1-4089 830
Italy
GRUNDFOS Pompe Italia S.r.l.
Via Gran Sasso 4
I-20060 Truccazzano (Milano)
Tel.: +39-02-95838112
Telefax: +39-02-95309290 / 95838461
Japan
GRUNDFOS Pumps K.K.
Gotanda Metalion Bldg., 5F,
5-21-15, Higashi-gotanda
Shiagawa-ku, Tokyo
141-0022 Japan
Phone: +81 35 448 1391
Telefax: +81 35 448 9619
Korea
GRUNDFOS Pumps Korea Ltd.
6th Floor, Aju Building 679-5
Yeoksam-dong, Kangnam-ku, 135-916
Seoul, Korea
Phone: +82-2-5317 600
Telefax: +82-2-5633 725
Latvia
SIA GRUNDFOS Pumps Latvia
Deglava biznesa centrs
Augusta Deglava ielā 60, LV-1035, Rīga,
Tālr.: + 371 714 9640, 7 149 641
Fakss: + 371 914 9646
Lithuania
GRUNDFOS Pumps UAB
Smolensko g. 6
LT-03201 Vilnius
Tel: + 370 52 395 430
Fax: + 370 52 395 431
Malaysia
GRUNDFOS Pumps Sdn. Bhd.
7 Jalan Peguam U1/25
Glenmarie Industrial Park
40150 Shah Alam
Selangor
Phone: +60-3-5569 2922
Telefax: +60-3-5569 2866
Mexico
Bombas GRUNDFOS de México S.A. de
C.V.
Boulevard TLC No. 15
Parque Industrial Stiva Aeropuerto
Apodaca, N.L. 66600
Phone: +52-81-8144 4000
Telefax: +52-81-8144 4010
Netherlands
GRUNDFOS Netherlands
Veluwezoom 35
1326 AE Almere
Postbus 22015
1302 CA ALMERE
Tel.: +31-88-478 6336
Telefax: +31-88-478 6332
E-mail: info_gnl@grundfos.com
New Zealand
GRUNDFOS Pumps NZ Ltd.
17 Beatrice Tinsley Crescent
North Harbour Industrial Estate
Albany, Auckland
Phone: +64-9-415 3240
Telefax: +64-9-415 3250
Norway
GRUNDFOS Pumper A/S
Strømsveien 344
Postboks 235, Leirdal
N-1011 Oslo
Tlf.: +47-22 90 47 00
Telefax: +47-22 32 21 50
Poland
GRUNDFOS Pompy Sp. z o.o.
ul. Klonowa 23
Baranowo k. Poznania
PL-62-081 Przeźmierowo
Tel: (+48-61) 650 13 00
Fax: (+48-61) 650 13 50
Portugal
Bombas GRUNDFOS Portugal, S.A.
Rua Calvet de Magalhães, 241
Apartado 1079
P-2770-153 Paço de Arcos
Tel.: +351-21-440 76 00
Telefax: +351-21-440 76 90
Romania
GRUNDFOS Pompe România SRL
Bd. Biruintei, nr 103
Pantelimon county Ilfov
Phone: +40 21 200 4100
Telefax: +40 21 200 4101
E-mail: romani[email protected]
Russia
ООО Грундфос Россия
109544, г. Москва, ул. Школьная, 39-41,
стр. 1
Тел. (+7) 495 564-88-00 (495) 737-30-00
Факс (+7) 495 564 88 11
E-mail grundfos.moscow@grundfos.com
Serbia
Grundfos Srbija d.o.o.
Omladinskih brigada 90b
11070 Novi Beograd
Phone: +381 11 2258 740
Telefax: +381 11 2281 769
www.rs.grundfos.com
Singapore
GRUNDFOS (Singapore) Pte. Ltd.
25 Jalan Tukang
Singapore 619264
Phone: +65-6681 9688
Telefax: +65-6681 9689
Slovakia
GRUNDFOS s.r.o.
Prievozská 4D
821 09 BRATISLAVA
Phona: +421 2 5020 1426
sk.grundfos.com
Slovenia
GRUNDFOS d.o.o.
Šlandrova 8b, SI-1231 Ljubljana-Črnuče
Phone: +386 31 718 808
Telefax: +386 (0)1 5680 619
E-mail: slovenia@grundfos.si
South Africa
GRUNDFOS (PTY) LTD
Corner Mountjoy and George Allen Roads
Wilbart Ext. 2
Bedfordview 2008
Phone: (+27) 11 579 4800
Fax: (+27) 11 455 6066
E-mail: lsmart@grundfos.com
Spain
Bombas GRUNDFOS España S.A.
Camino de la Fuentecilla, s/n
E-28110 Algete (Madrid)
Tel.: +34-91-848 8800
Telefax: +34-91-628 0465
Sweden
GRUNDFOS AB
Box 333 (Lunnagårdsgatan 6)
431 24 Mölndal
Tel.: +46 31 332 23 000
Telefax: +46 31 331 94 60
Switzerland
GRUNDFOS Pumpen AG
Bruggacherstrasse 10
CH-8117 Fällanden/ZH
Tel.: +41-44-806 8111
Telefax: +41-44-806 8115
Taiwan
GRUNDFOS Pumps (Taiwan) Ltd.
7 Floor, 219 Min-Chuan Road
Taichung, Taiwan, R.O.C.
Phone: +886-4-2305 0868
Telefax: +886-4-2305 0878
Thailand
GRUNDFOS (Thailand) Ltd.
92 Chaloem Phrakiat Rama 9 Road,
Dokmai, Pravej, Bangkok 10250
Phone: +66-2-725 8999
Telefax: +66-2-725 8998
Turkey
GRUNDFOS POMPA San. ve Tic. Ltd. Sti.
Gebze Organize Sanayi Bölgesi
Ihsan dede Caddesi,
2. yol 200. Sokak No. 204
41490 Gebze/ Kocaeli
Phone: +90 - 262-679 7979
Telefax: +90 - 262-679 7905
E-mail: satis@grundfos.com
Ukraine
Бізнес Центр Європа
Столичне шосе, 103
м. Київ, 03131, Україна
Телефон: (+38 044) 237 04 00
Факс.: (+38 044) 237 04 01
E-mail: ukraine@grundfos.com
United Arab Emirates
GRUNDFOS Gulf Distribution
P.O. Box 16768
Jebel Ali Free Zone
Dubai
Phone: +971 4 8815 166
Telefax: +971 4 8815 136
United Kingdom
GRUNDFOS Pumps Ltd.
Grovebury Road
Leighton Buzzard/Beds. LU7 4TL
Phone: +44-1525-850000
Telefax: +44-1525-850011
U.S.A.
GRUNDFOS Pumps Corporation
17100 West 118th Terrace
Olathe, Kansas 66061
Phone: +1-913-227-3400
Telefax: +1-913-227-3500
Uzbekistan
Grundfos Tashkent, Uzbekistan The Repre-
sentative Office of Grundfos Kazakhstan in
Uzbekistan
38a, Oybek street, Tashkent
Телефон: (+998) 71 150 3290 / 71 150
3291
Факс: (+998) 71 150 3292
Addresses Revised 10.03.2015
98959989 0815
ECM: 1164410
The name Grundfos, the Grundfos logo, and be think innovate are registered trademarks owned by Grundfos Holding A/S or Grundfos A/S, Denmark. All rights reserved worldwide. © Copyright Grundfos Holding A/S
www.grundfos.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14

Grundfos KPL.700-1400 Service Instructions Manual

Type
Service Instructions Manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI