JABSCO 37010 Series Quick start guide

Type
Quick start guide

JABSCO 37010 Series is an electric marine toilet designed for use on boats. It features a white vitreous china bowl available in two sizes, a baked enamel seat and cover in compact or household size, and a flexible impeller flush pump. The toilet also has a permanent magnet type motor, fully enclosed, with stainless steel shaft, a high capacity macerator and bowl scavenger pump, and a built-in back flow preventer. All materials used in the construction of the toilet are corrosion resistant, making it suitable for marine use.

JABSCO 37010 Series is an electric marine toilet designed for use on boats. It features a white vitreous china bowl available in two sizes, a baked enamel seat and cover in compact or household size, and a flexible impeller flush pump. The toilet also has a permanent magnet type motor, fully enclosed, with stainless steel shaft, a high capacity macerator and bowl scavenger pump, and a built-in back flow preventer. All materials used in the construction of the toilet are corrosion resistant, making it suitable for marine use.

1
Model 37010-Series
ELECTRIC MARINE TOI LET
Push Button Operation
FEATURES
• WhiteVitreousChinaBowlAvailableinTwoSizes
• BakedEnamelSeat&CoverinCompactor
HouseholdSize
• FlexibleImpellerFlushPump
• PermanentMagnetTypeMotor,FullyEnclosed,with
StainlessSteelShaft
• HighCapacityMaceratorandBowlScavengerPump
• Built-inBackFlowPreventer
• AllCorrosionResistantMaterialforMarineUse
VARIATIONS
VOLTAGE COMPACT SIZE HOUSEHOLD SIZE
12VdcEMC 37010-0090 37010-1090
24VdcEMC 37010-0096 37010-1096
INSTALLATION
TheJabscoelectrictoiletmaybeinstalledaboveorbelow
thewaterline.Flushpumpisself-primingwithaverticallift
up to 4 feet; discharge macerator pump can operate
againstaverticalheadupto4feet.
Inletandoutletseacocksshouldbeeasilyaccessibleand
be positive shut off valves. If seacocks cannot be
convenientlyoperatedfromtoiletlocation,installsuitable
shutoffvalvesforinletanddischargeconnections.
Base assembly may be moved 90° to accommodate
connectionsandprovideaccessibilityforservicing.
Surfacewheretoiletismountedshouldbeflattoprevent
distortionoftoiletbase.
PLUMBINGCONNECTIONS-Connectinlethoseusing
either5/8"or3/4"IDhose(asleeveisincludedtoadapt
pumpinletfrom5/8"to3/4").Makesureallinletconnections
areairtightandfreeofsharpbendsorrestrictions.
Connect 1" or 1-1/2" hose to discharge port (Adaptor
98023-0080 is included to convert discharge port to
1-1/2"IDhose),andmakesuitableconnectiontoholding
tank or other discharge system. Avoid sharp bends or
restrictions.
Forabovewaterlineinstallations,acheckvalvemayhave
tobeinstalledintheflushwaterintakelinetoensurerapid
pumppriming.Toretainwaterinbowl,makealoopinthe
dischargelineabout8inchesabovebaseofbowl.
DANGER
!
CAUTION
!
WARNING
!
WARNING
Floodhazard.Anytoiletinstalledbelowthewaterline
orwhichmaybebelowthewaterlineatanyangleof
heelortrimmustbeintalledwithproperlypositioned
ventedloops.Failuretodosocanresultinflooding
whichcancauselossofpropertyandlife.
Do not connect the toilet to the vessels
potablewaterforitssourceofsupply.Todosocanresult
incontaminationofpotablewatersupply.Iffreshwateris
preferredforflushing,provideaseparatefreshwatertank
tosupplywatertothetoiletonly.
DONOTCONNECTINLETHOSETOAPRESSURIZED
WATERSYSTEM.
Ifthetoiletis,orcanbe,belowwaterlineatanynormal
(includingstatic)attitudeofvesselheeland/ortrim,a3/4"
VentedLoopFittingmustbeinstalledinthelengthofhose
connecting the flushing pump to the inlet seacock.The
VentedLoopFittingmustbepositionedsoitremainsslightly*
abovethewaterlineatallanglesofheelandtrim.
Insomeinstallationswhenaventedloopisinstalledinthe
intake hose, the flushing pump primeability and flow
characteristics are reduced and may adversely affect
toiletfunction.Torestorepumpperformance,connecta
solenoid valve (Jabsco No. 37068-2000) to the vent air
inlet to interrupt the air supply during the flush cycle.
Screwthe¼”brassconnectorontotheventedloopand
wire the solenoid in parallel with the toilet motor. See
Diagram1forinstallationandwiringillustration.
*Recommendedminimumheightabovewaterlineis6".
ELECTRICAL CONNECTIONS - Select a location for
theswitchandinstructionplate,makingsurewireleads
fromboththetoiletandpowersourcecanberoutedto
theswitch.Ensurethepanelwhereinstallingswitchis
no more than 1" thick. Drill a 5/8" mounting hole and
installswitchandinstructionplate.Usestrandedcopper
wireofthecorrectsize(determinedfromtheelectrical
specificationschart)toconnectonesideoftheswitchto
thepositivepowersource.Anappropriatesizefuseor
CAUTION
2
equivalent circuit breaker (determined from electrical
specifications chart) must be installed in the positive
power lead within seven inches of the power source.
Connect the other side of the switch to the orange
(positive) motor lead. Connect the black (negative)
motor lead to the negative side of the battery or
groundedbussbar.
NOTICE: Correct motor polarity (orange to positive,
black to negative) is important. Reverse polarity can
damage motor and void warranty. Full voltage at the
motorisrequiredtoproperlyoperatetheElectricToilet.
Thetoiletmustbewiredinacircuitindependentofall
otheraccessories.
ELECTRICAL SPECIFICATIONS
AMP FUSE WIRE SIZE PER FEET OF RUN*
VOLTAGE DRAW SIZE 0'-10' 10'-15' 15'-25' 25'-40' 40'-60'
12Vdc 16 25 #12 #10 #10 #8 #6
24Vdc 8 15 #16 #14 #12 #10 #10
*Lengthofrunistotaldistancefrompowersourcetoproductandbacktoground.
OPERATING INSTRUCTIONS
Make sure inlet and outlet seacocks are all open; push
button
tooperate.Operateuntilbowliscompletelyflushed
anddischargepumphasscavengedwaterfrombottomof
bowl.
The Jabsco electric marine toilet will provide years of
troublefree serviceif properly used.Itwillhandlewaste
andtoilettissue.ItwillNOThandlerags,sanitarynapkins
orhardsolidobjects.
Ifbowldoesnotpumpoutandbeginstofill,partiallyclose
inletvalveuntilbowlisclearedandcompletelypumped
out.Thenoperateforafewsecondswithbothvalvesopen
toclearentiretoiletanddischargesystem.Formaximum
safety,whentoiletisnotinuseorvesselisunattended,
closeboththeinletanddischargeseacocks.
Todrainforwinterlay-up,closeinletvalveandoperatefor
afewsecondsuntilallwaterispumpedout.
After long periods of non-use,toilet andpump maydry
out.Toeaseinitialstart-up,putaboutonequartofwater
inbowlandletstandawhilebeforeinitialuse.
DISASSEMBLY
DANGER
!
CAUTION
!
WARNING
!
WARNING
Floodhazard.Closeinletandoutletseacockspriorto
disassembling toilet. Failure to do so can result in
floodingwhichcancauselossofpropertyandlife.
Disconnectpumpinginletanddischargehoses.Remove
fourscrews,KeyNo.25,pulloutcompletemotor,pump
andmaceratorassembly.Ifassemblydoesnotslideout
easily,pushforwardandpullbacksharplyseveraltimes
tofreemaceratorhousingfrombase.
Remove discharge port, Key No. 12, and joker valve.
Unscrewchopperplate,KeyNo.14,byturningcounter-
clockwise, facing plate. Prevent shaft from turning by
placing screwdriver in discharge port and locking
centrifugal impeller blade. Remove macerator housing.
Loosen impeller set screw and slide impeller off motor
shaft.
Removefourflatheadscrewsandtwowashers,KeyNos.
20,21,&22.Removetheplasticwearplate,KeyNo.23,
withsealingsleeve,KeyNo.19,andgasket,KeyNo.26.
Slidepumpassemblyoffmotorshaft.Replaceallwornor
damagedparts,cleanremainingparts.
ASSEMBLY
Presssealintobodywithlipfacingimpeller;becareful
nottococksealinbore.Installpumpbodyonmotorand
positiononregister.Lubricateimpellerborewithpump
greaseandinstallimpeller.Positionthegasketagainst
the body and install the wearplate ensuring the two
plasticsealingwashersareundertheheadsofthetop
andbottomscrews.NOTE:Thecurrentplasticwearplate
supercedestheearlierbrasswearplateandwithitthe
stainless steel wearplate is no longer used. Slide the
rubber sealing sleeve on the motor shaft and push it
into its recess in the wearplate. Relocate centrifugal
impeller on shaft, about 1/8" from the wearplate, and
tightenset screw.Place macerator housing over shaft
andcentrifugalimpeller,putlockwasheronendofshaft
and screw chopper plate on shaft and tighten. Install
O-ring in O-ring groove in wearplate surface, a little
greasewill help hold inplace,make sure inside body
surfaces are clean, line up slot in base with key on
maceratorhousing,slidepumpassemblyintobaseand
tighten with the fourscrews.Turnmotor on forone or
twosecondstobesurecentrifugalimpellerisfree.
NOTE:Theswitchonthesideof
the solenoid is inactive and will
notaffectoperation.
-
+
-
DISCHARGE
TO
NEGATIVE
TO
POSITIVE
TO
NEGATIVE
VENTED LOOP
Heeled
Waterline
Static
VIEW A
SWITCH
INLET
VIEW A
VENT TO
ATMOSPHERE
1/4" BSP
BRASS
CONNECTOR
(Screws on to
Vented Loop)
Use PTFE tape
to seal
connector
onto Vented
Loop
ELECTRICAL
CONNECTIONS
Diagram1
3
PARTS LIST
Key Description Qty. Part Number
1 Seat,LidandHingeSet 1 
CompactToilet 29097-1000
RegularToilet  29127-1000
1A HingeSet(1Pair) 1 
CompactToilet 29098-1000
RegularToilet  29098-2000
2 Bowl,CompactSize 1 29096-0000
Bowl,RegularSize 1 29126-0000
3&4 BowlSpud&Intake 1 29048-0000
Elbow&O-ring
5 Clamp 1 18753-0044
6 Hose 1 29035-1001
7 BowlInstallationHardware 1 18753-0637
7A PhillipsHeadScrew** 4
7B Washer,Starlock** 4
7C HexNut**(twoplaces) 4
7D Washer,Plastic** 4
7E WasherStainlesssteel** 8
7F NutCap** 4
8 O-RingBowl/Seal 1 44101-1000
9 BaseAssembly** 1 37004-1000
10 1-1/2"Adaptor,DischargePort 1 98023-0080
11 JokerValve*** 1 44106-1000
12 1"DischargePort** 1 44107-1000
13 Screw** 3 96050-0568
14 ChopperPlate†withLockNut 1 37056-1000
15 MaceratorHousing† 1 37014-0000
16 CentrifugalImpeller† 1 37006-0000
17 SetScrew† 1 18753-0492
18 O-ring*† 1 43990-0066
19 SealingSleeve† 1 37036-1000
20 Screw† 2 91009-0096
21 Screw† 2 91010-0130
22 Washer,Fiber*† 2 35445-0000
23 WearplateKit‡† 1 37018-0000
24 LockWasher#10,StainlessKit† 4
25 Screw† 4 91027-0011
26 Gasket*† 1 12558-0000
27 FlexibleImpeller*† 1 6303-0003
28 Body† 1 12554-0000
29 Seal&Retainer*† 1 1040-0000
Key Description Qty. Part Number
30 Slinger† 1 6342-0000
31 Motors:
Motor-12VoltEMC† 1 37064-0000
Motor-24VoltEMC† 1 37065-0000
32 Adaptor 2 93003-0240
33 Switch&Plate 1 37020-0000
34 MotorCover† 1 43990-0051
35 ScrewCover(3each) 1 37003-1000
ServiceKit 37040-0000
Motor/PumpAssy.12VEMC† 37041-0010
Motor/PumpAssy.24VEMC† 37041-0011
* PartsSuppliedwithServiceKit37040-0000.
** Partsincludedwithbase37004-1000.
‡ Wearplate#23includesSealingSleeve#19andPump/
BaseO-ring#18.
† PartsincludedinMotor-PumpAssembly.
O
T
H
S
U
P
F
L
U
S
H
T
R
I
C
C
E
L
E
T
O
I
L
E
T
8
9
10
11
14
12
13
21
20
4
15
16
17
18
22
23
24
25
26
27
28
29
30
31
32
5
6
3
2
7F
7C
7E
7D
7A
34
33
19
1
7B
35
7C
EXPLODED VIEW
TO
BOWL
ELBOW
4
DIMENSIONAL DRAWING
INCHES(MILLIMETRES)
A B C D E F G
COMPACTSIZEBOWL 19-3/4(493) 4-13/16(123) 13-13/16(351) 13-7/8(352) 17-3/4(451) 9-7/8(251) 7-5/8(194)
HOUSEHOLDSIZEBOWL 21-3/4(543) 5-11/16(148) 14-5/8(372) 14-3/4(375) 19-3/4(502) 11-1/4(286) 8-1/2(216)
D Overall Width
1 (25)
Dia
4
(102)
6 (152)
B
5/16
(8)
3-1/8
(79)
5/8 (16) Dia
2 Places
C
F
G
E
2 Leads - 11 (279) Long
12-15/16
10-7/8
A
3-1/2
(89)
7-3/8
(187)
2-1/2
(64)
3-7/8
(98)
4
(102)
5+3/8
(137)
5/8
(16)
MOTORCOVER
Form: 43000-0612 Rev. 01/2009
USA
ITTCorporation
CapeAnnIndustrialPark
Gloucester,MA01930
Tel:(978)281-0440
Fax:(978)283-2619
UK
ITTIndustries
BingleyRoad,Hoddesdon
HertfordshireEN110BU
Tel:+44(0)1992450145
Fax:+44(0)1992467132
JAPAN
NHKJabscoCompanyLtd.
3-21-10,Shin-Yokohama
Kohoku-Ku,Yokohama,222-0033
Tel:+81-045-475-8906
Fax:+81-045-477-1162
ITALY
JabscoMarineItalia
ViaTommaseo,6
20059Vimercate,Milano
Tel:+390396852323
Fax:+39039666307
GERMANY
JabscoGmbH
Oststrasse28
22844Norderstedt
Tel:+49-40-535373-0
Fax:+49-40-535373-11
Warranty:Allproductsofthecompanyaresold,andallservicesofthecompanyareofferedsubjecttothecompany’swarrantyandtermsofsale,copiesofwhichwillbefurnisheduponrequest.
Detailscorrectattimeofprinting.Wereservetherighttochangespecicationswithoutpriornotice.
©Copyright2009ITTIndustries,RegisteredEnglandNo.81415,registeredofce:JaysCloseViablesEstate,Basingstoke,Hants,RG224BA
www.jabsco.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

JABSCO 37010 Series Quick start guide

Type
Quick start guide

JABSCO 37010 Series is an electric marine toilet designed for use on boats. It features a white vitreous china bowl available in two sizes, a baked enamel seat and cover in compact or household size, and a flexible impeller flush pump. The toilet also has a permanent magnet type motor, fully enclosed, with stainless steel shaft, a high capacity macerator and bowl scavenger pump, and a built-in back flow preventer. All materials used in the construction of the toilet are corrosion resistant, making it suitable for marine use.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI