FRAMTID HGA5K PRODUCT DESCRIPTION SHEET
DE AT
5019 619 01357
HB G32
Operation of burners with safety
device and electric ignition
To light one of the burners:
Press the relative knob and turn it anti-
clockwise to the large flame and star
setting .
At the same time, hold the knob down until
the burner ignites.
After the burner has ignited, keep the knob
pressed down for about 10 seconds.
Release the knob.
If the burner does not ignite, repeat the operations
described above.
Note:
Should particular local conditions of the
delivered gas make ignition of the burner
difficult, it is advisable to repeat the operation
with the knob turned to the small flame
setting .
The burner safety device shuts off the gas
supply to the burner if the flame goes out
accidentally (because of a sudden draught,
an interruption in the gas delivery, boiling
over of liquids, etc.).
The separator panel, positioned beneath the
cooktop at a minimum distance of 20 mm,
must be sealed.
1. Removable panstand grids
2-5. Medium burners
3. Large burner
4. Small burner
6. Triple crown burner
7. Small burner control knob
8. Large burner control knob
9. Triple crown burner control knob
10. Medium burner control knob
11. Medium burner control knob
Symbols
Shaded
circle
Tap closed
Large flame
and star
Maximum opening/delivery
and electric ignition
Small flame
Minimum opening
or reduced delivery
DIMENSIONS OF COOKING HOB AND
WORKTOP (mm)
NOTE: If the distance “A” between the wall cabinets is between 600 mm and 680 mm,
the height “B” must be a minimum of 520 mm.
If the distance “A” between the wall cabinets is greater than the width of the
cooktop, the height “B” must be a minimum of 400 mm.
Before installing a hood above the cooktop please refer to the hood instructions,
which specify the correct distance. In case of installation of an oven under the
cooktop, please refer to the separate oven instructions.
(DE) CATEGORY II2ELL3B/P
INJECTORS TABLE
(AT) CATEGORY II2H3B/P
*Not supplied in Austria
ELECTRIC SUPPLY: 230 V ~ 50 Hz
NB: To replace the injectors, refer to the “INSTRUCTIONS FOR USE” handbook,
“INSTALLATION” section. In this product, the triple crown burner has only one
injector (D), therefore the instructions given in point 6 do not have to be followed..
Typ e o f
gas used
Typ e o f
burner
Injector
marking
Nominal
heating
capacity
kW
Nominal
consumption
Reduced
heat
capacity kW
Gas pressure mbar
min. nom. max.
NATURAL GAS
(Methane) G20
Tr i p l e c r o w n
large
medium
small
132
Y 115
H2 98
X 72
3.30
3.00
1.65
1.00
314 l/h
286 l/h
157 l/h
95 l/h
1.55
0.60
0.35
0.30
17 20 25
NATURAL GAS
(Methane)* G25
Tr i p l e c r o w n
large
medium
small
144
F3 134
Y 98
F1 77
3.30
3.00
1.65
1.00
365 l/h
332 l/h
183 l/h
111 l/h
1.55
0.60
0.35
0.30
18 20 25
LIQUID
PETROLEUM GAS
(Butane / Propane)
G30/G31
Tr i p l e c r o w n
large
medium
small
81
S 75
M 57
H2 45
3.30
3.00
1.65
1.00
240 g/h
218 g/h
120 g/h
73 g/h
1.90
0.80
0.50
0.40
42.5 50 57.5
Ty pe o f
gas used
Appliance
model
Nominal heating
capacity kW
Total nominal
consumption
Air required for
burning m
3
/h
G20 20 mbar 5 gas 10.60 1009 l/h 9.52
G25 20 mbar* 5 gas 10.60 1174 l/h 8.187
G30/G31 50 mbar 5 gas 10.60 771 g/h 30.94
IKEA of Sweden AB
SE - 343 81 Älmhult
/