IKEA HB G33 S Program Chart

Type
Program Chart
FRAMTID HGA5K PRODUCT DESCRIPTION SHEET
ES PT IT GB
5019 619 01358
HB G33
Operation of burners with safety
device and electric ignition
To light one of the burners:
Press the relative knob and turn it anti-
clockwise to the large flame and star
setting .
At the same time, hold the knob down until
the burner ignites.
After the burner has ignited, keep the knob
pressed down for about 10 seconds.
Release the knob.
If the burner does not ignite, repeat the operations
described above.
Note:
Should particular local conditions of the
delivered gas make ignition of the
burner difficult, it is advisable to repeat
the operation with the knob turned to
the small flame setting .
The burner safety device shuts off the gas
supply to the burner if the flame goes out
accidentally (because of a sudden draught,
an interruption in the gas delivery,
boiling over of liquids, etc.).
The separator panel, positioned beneath the
cooktop at a minimum distance of 20 mm,
must be sealed.
1. Removable panstand grids
2-5. Medium burners
3. Large burner
4. Small burner
6. Triple crown burner
7. Small burner control knob
8. Large burner control knob
9. Triple crown burner control knob
10. Medium burner control knob
11. Medium burner control knob
Symbols
Shaded
circle
Tap closed
Large flame
and star
Maximum opening/delivery
and electric ignition
Small flame
Minimum opening
or reduced delivery
DIMENSIONS OF COOKING HOB AND
WORKTOP (mm)
NOTE: If the distance “A” between the wall cabinets is between 600 mm and 680 mm,
the height “B” must be a minimum of 520 mm.
If the distance “A” between the wall cabinets is greater than the width of the
cooktop, the height “B” must be a minimum of 400 mm.
Before installing a hood above the cooktop please refer to the hood instructions,
which specify the correct distance. In case of installation of an oven under the
cooktop, please refer to the separate oven instructions.
INJECTORS TABLE CATEGORY II2H3+
ELECTRIC SUPPLY: 230 V ~ 50 Hz
NB: To replace the injectors, refer to the “INSTRUCTIONS FOR USE” handbook,
“INSTALLATION” section. In this product, the triple crown burner has only one
injector (D), therefore the instructions given in point 6 do not have to be followed.
Typ e o f
gas used
Typ e o f
burner
Injector
marking
Nominal
heating
capacity
kW
Nominal
consumption
Reduced
heat capacity
kW
Gas pressure mbar
min. nom. max.
NATURAL GAS
(Methane) G20
Triple crown
large
medium
small
132
Y 115
H2 98
X 72
3.30
3.00
1.65
1.00
314 l/h
286 l/h
157 l/h
95 l/h
1.55
0.60
0.35
0.30
17 20 25
LIQUID
PETROLEUM
GAS
(Cylinder) G30
Triple crown
large
medium
small
92
87
65
50
3.30
3.00
1.65
1.00
240 g/h
218 g/h
120 g/h
73 g/h
1.55
0.60
0.35
0.30
20 28-30 35
LIQUID
PETROLEUM
GAS
(Cylinder) G31
Triple crown
large
medium
small
92
87
65
50
3.30
3.00
1.65
1.00
236 g/h
214 g/h
118 g/h
71 g/h
1.55
0.60
0.35
0.30
25 37 45
Type of gas used
Appliance
model 5 BURNERS
Nominal heating
capacity
kW
To t a l
nominal
consumption
Air required (m
3
) for
burning 1m
3
of gas
G20 20 mbar 3C - 1 R - 2 SR - 1 AUX 10.60 1009 l/h 9.52
G30 28-30 mbar 3C - 1 R - 2 SR - 1 AUX 10.60 771 g/h 30.94
G31 37 mbar 3C - 1 R - 2 SR - 1 AUX 10.60 757 g/h 23.8
IKEA of Sweden AB
SE - 343 81 Älmhult
  • Page 1 1
  • Page 2 2

IKEA HB G33 S Program Chart

Type
Program Chart

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI