Whirlpool AKM 394/JA Program Chart

Category
Cookers
Type
Program Chart

This manual is also suitable for

AKM 394 PRODUCT DESCRIPTION SHEET
IT
5019 319 01403
Operation of burners with safety
device and electric ignition
To light one of the burners:
Press the relative knob and turn it anti-
clockwise to the large flame and star
setting .
At the same time, hold the knob down until
the burner ignites.
After the burner has ignited, keep the knob
pressed down for about 10 seconds.
Release the knob.
If the burner fails to light, repeat the above steps.
Note:
Should particular local conditions of the
delivered gas make ignition of the burner
difficult, it is advisable to repeat the operation
with the knob turned to the small flame
setting .
The burner safety device shuts off the gas
supply to the burner if the flame goes out
accidentally (because of a sudden draught, an
interruption in the gas delivery, boiling over of
liquids, etc.).
The separator panel, positioned beneath the
cooktop at a minimum distance of 20 mm,
must be sealed.
1.
Removable panstand grids
2-5.
Medium burners
3.
Rapid burner
4.
Small burner
6.
Tr i p l e c r o w n b u r n e r
7.
Auxiliary burner control knob
8.
Large burner control knob
9.
Triple crown burner control knob
10.
Medium burner control knob
11.
Medium burner control knob
Symbols
Shaded
circle
tap closed
Large flame
and star
Maximum opening/
delivery
and electric ignition
Small
flame
Minimum opening
or reduced delivery
DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
NOTE: If the distance “A” between the wall cabinets is between 600 mm and 680 mm, the height “B
must be a minimum of 520 mm.
If the distance “A” between the wall cabinets is greater than the width of the cooktop, the
height “B” must be a minimum of 400 mm.
In case of installation of a hood above the cooktop, please refer to the hood instructions for the
correct distance. In case of installation of an oven under the cooktop, please refer to the
separate oven instructions.
INJECTORS TABLE CATEGORY
11
2H3+
ELECTRIC SUPPLY: 230 V ~ 50 Hz
NB
: To replace the injectors, refer to the
“INSTRUCTIONS FOR USE”
handbook,
“INSTALLATION
section. In this product, the triple crown burner has only one injector (D),
therefore the instructions given in point
6
do not have to be followed.
Type of
gas used
Type of
burner
Injector
marking
Rated
heat
capacity
kW
Rated
consumption
Reduce d
heat
capacity
kW
Gas pressure mbar
min. rat. max.
NATURAL GAS
(Methane) G20
Tr i p l e c r o w n
large
medium
small
132
Y 115
H2 98
X 72
3.30
3.00
1.65
1.00
314 l/h
286 l/h
157 l/h
95 l/h
1.50
0.60
0.35
0.30
17 20 25
LIQUID
PETROLEUM GAS
(Butane) G30
Tr i p l e c r o w n
large
medium
small
92
87
65
50
3.30
3.00
1.65
1.00
240 g/h
218 g/h
120 g/h
73 g/h
1.50
0.60
0.35
0.30
20 28-30 35
LIQUID
PETROLEUM GAS
(Propane) G31
Tr i p l e c r o w n
large
medium
small
92
87
65
50
3.30
3.00
1.65
1.00
236 g/h
214 g/h
118 g/h
71 g/h
1.50
0.60
0.35
0.30
25 37 45
Type of
gas used
Appliance
model
Total rated heat
capacity
kW
To t a l r a t e d
consumption
Air required (m
3
) for
burning 1m
3
of gas
G20 20mbar 5 gas 10.60 1009 l/h 9.52
G30 28-30 mbar 5 gas 10.60 771 g/h 30.94
G31 37 mbar 5 gas 10.60 757 g/h 23.80
  • Page 1 1
  • Page 2 2

Whirlpool AKM 394/JA Program Chart

Category
Cookers
Type
Program Chart
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI