  • Hello! I am an AI chatbot trained to assist you with the Martin Magnum Hazer Operating instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
P/N 35011503 Instruction, Jet cleaning ZR24/7 & Magnum Hazer
25/10/04
Revision A
The ZR24/7 & Magnum Hazers have now been fitted with a Brass
elbow/connector that allows total cleaning of the internal 0.5mm orifice. This is
on units from serial number 6022901001 and onwards.
To clean the components of any contaminants which may restrict the output,
please follow the cleaning instructions laid out below.
? Remove the brass elbow from the 1/8
th
copper pipe (A) and the block input
(B). (Picture 1)
? This will leave the 1/8
th
elbow, the screw on straight and internal straight,
which will be left as one assembled component. (Picture 2)
Picture 1 Picture 2
? Undo the two components and pull apart (Picture 3)
? Clean the 0.5mm orifice using <0.5mm wire.
? Once happy the components are clean, re-assemble and connect to the unit.
? Prime the unit as per the instruction manual. The unit will now be fully
operational.
? Picture 4, is the complete broken down valve.
Picture 3 Picture 4
B
Clean the input
orifice
A
/