IMC Networks IE-MiniFiberLinX-II,TP-TX/SSFX-SM1550/LONG-SC User manual

Category
Network media converters
Type
User manual

This manual is also suitable for

800-624-1070
www.imcnetworks.com
Features
Smallest Standalone Fiber Optic Network
Interface Device
VLAN Compatible - secure and separate
customer traffic
Supports passive 802.3ah OAM (Operation,
Administration & Management)
Extra Tagging (Q-in-Q)
Supports Remote Loopback with MAC
Address Swap
Management
Carrier-grade SNMP management and line
provisioning
Link loss and loopback troubleshooting
Free iView² EMS allows remote bandwidth
management and traffic prioritization
“Industrial Equipment” (IE) features for
operation in difficult environments
Extended temperature functionality,
up to -20° to +75° C
Multiple power options: AC, DC and
802.3af Power over Ethernet
DIN clips for DIN-R ail mounting
Quality product
Made in America with a comprehensive
six-year warranty
Transparent LAN service providers require remote management
capabilities, and must be able to isolate management traffic and
customer data. Typical Customer Premises Equipment (CPE)
do not allow this, since those devices are usually owned by
the customer and inaccessible to the network operator. The
compact IE-MiniFiberLinX-II, functioning as a more advanced
Network Interface Device (NID), is designed for operation
by service providers and campus network administrators. It
provisions point-to-point fiber optic connections and provides
a remote network interface at the customer’s location that
monitors the entire link between two locations.
The IE-MiniFiberLinX-II for fiber optic networks allows service
providers to deliver managed, high-bandwidth “triple play
voice, video and data services to customer premises.
The IE-MiniFiberLinX-II and the fiber link can be managed as
a single entity, allowing remote configuration and autonomous
alerts to network administrators on fault conditions. As a copper-
to-fiber media converter, it allows low-cost copper switches to
connect to the fiber line. Offering unparalleled flexibility, the
IE-MiniFiberLinX-II supports multiple fiber types including multi-
mode and single-mode as well as single-strand fiber, doubling
the capacity of installed fiber. Coarse Wavelength Division
Multiplexing (CWDM) functionality is also an option.
The IE-MiniFiberLinX-II comes equipped with one 100 Mbps
fiber port for data and management, one 10/100 twisted pair
port for customer data, as well as an RS-232 port for local
configuration on the unit during installation.
The IE-MiniFiberLinX-II supports multiple powering options. Use
the included AC power adapter or use a 4-terminal DC power
block, which has an extended voltage range of 5 to 50VDC. The
IE-MiniFiberLinX-II also complies with the IEEE 802.3af Power
over Ethernet standard, acting as a Powered Device (PD) to draw
power when connected to 802.3af-compliant Power Sourcing
Equipment (PSE).
Combining copper-to-fiber conversion, extended
temperature performance, plug-and-play
operation, miniature size and multiple power
options, the IE-MiniFiberLinX-II is one of the
most versatile fiber optic NID devices available
on the market today.
IE-MiniFiberLinX-II
www.imcnetworks.com 800-624-1070
SNMP-Manageable Optical Ethernet Demarcation Unit For 10/100 Mbps Ethernet
Compact Fiber Optic Network Interface Device
for Industrial-Grade Delivery of Transparent
LAN Services over Fiber, with Media Conversion,
Carrier Grade Remote Management and Line
Provisioning Capabilities.
NID Application
Typical Application—
Service Provider
RoHS Compliant
www.imcnetworks.com 800-624-1070
Full-Featured IE-MiniFiberLinX-II
VLAN Support— VLAN tagging capability keeps customer
data and SNMP traffic separated
Troubleshooting Features— FiberAlert, LinkLoss and 802.3ah
Passive OAM (Operations, Administration and Maintenance)
assist in diagnosing potential problems on fiber optic networks
Loopback Testing— Functionality loops back all frames
arriving on the fiber port (except for the device’s management
traffic). Supports MAC Address swap on Loopbacks
Bandwidth Control— Fine granularity allows operators to
offer custom levels of service and easily change bandwidth
allocation, remotely, in seconds via SNMP
Supports the Unified Management Agent (UMA)—
The FiberLinX family has always supported Host/Remote
environments, i.e. managing the Remote from the Host
location. With UMA, operators can centrally manage all
devices installed in an iMediaChassis using only a single IP
address for the chassis. Refer to the UMA data sheet for more
information
IEEE 802.1Q VLAN compatible
Valid VLAN IDs are 1 to 4,094
Port-based VLAN tagging and Q-in-Q (extra tagging)
Transparency Mode passes all data and respects the VLAN tag or
lack thereof, i.e. allows a mixture of VLAN Tagged and Untagged
traffic
Configure to support VLAN IDs, filtering/passing up to 32 VLAN IDs
for data, plus an additional VLAN ID for SNMP management
IEEE 802.1p provides a two-tier queue for differential prioritization
of inbound and outbound traffic, which is especially beneficial for
traffic requiring high priority, such as VoIP
Service providers routinely use IEEE 802.1Q Virtual Local Area Network (VLAN) tagging to secure, separate and differentiate customer traffic. The
IE-MiniFiberLinX-II enables service providers support of multiple VLAN-based applications.
From a central location, network operators are able to receive real-time device and traffic statistics on the remote device, allocate bandwidth, turn
services on or off, initiate loopback testing, modify VLAN settings and adjust QoS policies assigned to different traffic types.
Using the VLAN Functionality on the IE-MiniFiberLinX-II
Scalability allows transport of data on up to eight wavelengths Increase bandwidth without the addition of more fiber strands
Optionally, the IE-MiniFiberLinX-II provide for Coarse Wave Division Multiplexing, adding scalability to data delivery
Using Coarse Wavelength Division Multiplexing (CWDM) with the IE-MiniFiberLinX-II
SNMP Management Made Easy
The IE-MiniFiberLinX-II features an SNMP management
agent for monitoring the status and activity on copper
and fiber ports at the remote end. Initial setup and
modifications can be performed in the field via iView²
SNMP application, Telnet/TFTP, or a local serial (CRAFT)
connection.
Remote, software upgrades via Telnet/TFTP or
management software ( iView²)
Monitor unit and fiber with real-time monitoring and
statistics
Change bandwidth “on-the-fly” up to 100 Mbps
Create a secure management domain to isolate
management domain broadcasts from TX Data ports
on both units
User-definable unit/port descriptions and information
www.imcnetworks.com 800-624-1070
General
Preserves complete end-to-end fiber
connection integrity
Bi-directional bandwidth control
Read/write IEEE 802.1Q VLAN-tags
Supports Extra Tagging (Q-in-Q)
Supports passive 802.3ah OAM
(Operation, Administration &
Management)
QoS: IEEE 802.1p-based packet
prioritization (2 queues [high/low] with
8 levels of priority)
Layer 2 packet switching, store and
forward operation
Forwarding rate: 14,881 pps for 10 Mbps;
148,810 pps for 100 Mbps
AutoCross for MDI/MDIX
Features Auto Negotiation and Selective
Advertising
Supports Half and Full-Duplex operation
MTU: Supports over-sized packets up to
1916 bytes per packet
Security
Password Control
Multiple Access Levels: User Assigned
Accounts & Access Levels
Management
SNMP V1 and V2c compatible
Includes GUI-based iView² software for
remote management and upgrades
Monitors far-end (remote) status without a
physical presence or separate connection
IEEE 802.3x Flow Control
Includes DHCP and TFTP clients
Supports Telnet
Includes loopback test modes
(MAC swap)
Includes LinkLoss and FiberAlert
Supports the Unified Management Agent
(UMA)
Includes status LEDs
RS-232 (Craft) interface for local
management
Serial cable for direct connection to a
PC’s Serial Port
Ethernet Types Supported
IEEE 802.3i 10Base-T twisted pair
IEEE 802.3u 100Base-TX twisted pair
IEEE 802.3u 100Base-FX or SX fiber
Technical Specifications
Network operators can deploy a single
IE-MiniFiberLinX-II in stand-alone applications. At
the Central Office (CO), a fiber switch connects
via a fiber cable to the IE-MiniFiberLinX-II at the
customer premises. The IE-MiniFiberLinX-II can be
managed from the CO over SNMP or Telnet.
The IE-MiniFiberLinX-II is very versatile and offers
a range of AC and DC powering options. It
also supports 802.3af powering functionality,
allowing it to act as a Powered Device (PD).
The IE-MiniFiberLinX-II can be powered from a
PSE-enabled wireless Access Point, which in turn
can be powered by a remote source such as
the solar panels on a street light. The data is
transmitted over fiber to an iMediaChassis/20 with
iMcV modules in the Central Office to form an
end-to-end managed system.
Typical Application— Single
IE-MiniFiberLinX-II Solution
Application Examples (cont.)
Typical Application— Powering
Options
NID Application
Networking
RoHS Compliant
Fiber Types Supported
50/125µm or 62.5/125µm multi-mode fiber
9/125µm single-mode fiber
Single-strand fiber or CWDM
Connectors: RJ-45, and ST or SC
Shipping Weight: 0.30 lbs (0.11 kg)
Dimensions: 0.83”H x 1.80”W x 3.35”D
(2.11 x 4.57 x 8.51 cm)
Environmental
Humidity: 5% - 95% (non-condensing)
Operating Temperature: -4° to +167° F
(-20° to +75° C) excluding AC wall adapter;
with AC wall adapter:
+32° to +122° F (0° to +50°C)
Storage Temperature:
-49° to +185° F (-45° to +85° C)
Power
DC Input Voltage:
750mA @ 5V to 75mA @ 50 VDC
IEEE 802.3af Power over Ethernet
Physical Specifications
DS-IE-Mini-FiberLinx-II-1005
Copyright © 2010 IMC Networks. All rights
reserved. The information in this document is
subject to change without notice. IMC Networks
assumes no responsibility for any errors that may
appear in this document. Specific product names
may be trademarks or registered trademarks and
are the property of their respective companies.
IMC Networks
Fiber Consulting Services
For information call:
TEL: 949-465-3000
1-800-624-1070
(US/CAN)
+32-16-550880 (Europe)
IMC Networks
Headquarters
19772 Pauling
Foothill Ranch, CA 92610
TEL: 949-465-3000
FAX: 949-465-3020
IMC Networks
Europe
Herseltsesteenweg 268
B-3200 Aarschot, Belgium
TEL: +32-16-550880
FAX: +32-16-550888
IMC Networks
Eastern US/Latin America
28050 U.S. Hwy. 19 North, Suite 306
Clearwater, FL 33761
TEL: 727-797-0300
FAX: 727-797-0331
IMC MIB:
·Traps (Cold Start, Warm Start,
Authentication Failure, Link Up, Link
Down, Remote Unit Lost, Remote
Unit Back Online, Far End TX Link
On and Far End TX Link Off)*
· Link Status of Ports
· Port Type
· Fiber Type
· SNMP Port (Host/Remote)
· SNMP Agent IP Address
(Host/Remote/Single)
· Link Partner
· User-Definable Name of Product
· User-Definable ID/Name of Ports
· Enable/Disable Ports
· Enable/Disable FiberAlert
· Enable/Disable loopback modes
· Set Duplex Mode for Twisted
Pair Ports
· Set Auto Negotiation/Speed for
Twisted Pair Ports
MIB-II (RFC 1213):
· Packets Transmitted
· Packets Received
· Octets (bytes) Transmitted
· Octets (bytes) Received
· Plus All Standard MIB II Objects
RMON Statistics provided for:
· Drop Events
· Total Bytes
· Total Packets
· Broadcast Packets
· Multicast Packets
· CRC Align Errors
· Undersize Packets
· Oversize Packets
· Fragments
· Jabbers
· Collisions
· Distribution of Frame Size
*Send traps to a virtually unlimited number of trap-host server destinations.
Ordering Information
Technical Specifications (con’t.)
PART NUMBER
W/ AC ADAPTER
PART NUMBER
W/O AC ADAPTER
DESCRIPTION DISTANCE
IE-MiniFiberLinX-II TP-TX/FX (Industrial Ethernet)
856-19717 856-19740 IE-MiniFiberLinX-II, TP-TX/FX-MM850-ST 2 km
856-19718 856-19741 IE-MiniFiberLinX-II, TP-TX/FX-MM850-SC 2 km
856-19722 856-19732 IE-MiniFiberLinX-II, TP-TX/FX-MM1300-ST 5 km
856-19723 856-19733 IE-MiniFiberLinX-II, TP-TX/FX-MM1300-SC 5 km
856-19724 856-19734
IE-MiniFiberLinX-II, TP-TX/FX-SM1310/PLUS-ST 40 km
856-19725 856-19735 IE-MiniFiberLinX-II, TP-TX/FX-SM1310/PLUS-SC 40 km
856-19726 856-19736 IE-MiniFiberLinX-II, TP-TX/FX-SM1310/LONG-ST 40 km
856-19727 856-19737 IE-MiniFiberLinX-II, TP-TX/FX-SM1310/LONG-SC 40 km
856-19730 - IE-MiniFiberLinX-II, TP-TX/FX-SM1550/LONG-SC 80 km
856-19728 - IE-MiniFiberLinX-II, TP-TX/FX-SM1550/XLONG-SC 100 km
IE-MiniFiberLinX-II TP-TX/SSFX Single-Strand Fiber* (Industrial Ethernet)
856-19750 856-19760 IE-MiniFiberLinX-II, TP-TX/SSFX-MM1300-SC (1550rcv) 2 km
856-19751 856-19761 IE-MiniFiberLinX-II, TP-TX/SSFX-MM1550-SC (1310rcv) 2 km
856-19752 856-19762 IE-MiniFiberLinX-II, TP-TX/SSFX-SM1310-SC (1550rcv) 20 km
856-19753 856-19763 IE-MiniFiberLinX-II, TP-TX/SSFX-SM1550-SC (1310rcv) 20 km
856-19754 856-19764 IE-MiniFiberLinX-II, TP-TX/SSFX-SM1310/PLUS-SC (1550rcv) 40 km
856-19755 856-19765 IE-MiniFiberLinX-II, TP-TX/SSFX-SM1550/PLUS-SC (1310rcv) 40 km
856-19756 856-19766 IE-MiniFiberLinX-II, TP-TX/SSFX-SM1310/LONG-SC (1550rcv) 60 km
856-19757 856-19767 IE-MiniFiberLinX-II, TP-TX/SSFX-SM1550/LONG-SC (1310rcv) 60 km
* These products have single-strand fiber technology. Deploy in pairs, or connect to another compatible IMC Networks single-strand fiber product.
For more information go to: www.imcnetworks.com/products/SSFX.cfm
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

IMC Networks IE-MiniFiberLinX-II,TP-TX/SSFX-SM1550/LONG-SC User manual

Category
Network media converters
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI