Universal Hardware UH4062 Operating instructions

Type
Operating instructions

This manual is also suitable for

UNIVERSAL
HARDWARE
The Professional’s Choice
DOOR CLOSER
UH4061 & UH4062 INSTALLATION INSTRUCTIONS
FOR CUSTOMER CARE CALL TOLL FREE 800-562-5625 or [email protected]
PAGE 1
MULTI SIZE 1 THRU 6 — NON HOLD OPEN DOOR CLOSER
CAUTION! An incorrectly installed or improperly adjusted door closer can cause property damage or personal injury. These instructions should be followed
to avoid the possibility of misapplication or misadjustment.
Closer mounts opposite
of hinge side of door (push side)
Closer cover not shown.
See Page 5.
Left hand door-LH
Right hand door-RH
Left hand door-LH
Right hand door-RH
Closer mounts on hinge side of door (pull side)
Closer cover not shown.
Regular Arm Installation
Top Jamb Installation
Parallel Arm Installation
See Page 3.
Closer mounts on frame,
opposite hinge side of door (push side)
Closer cover not shown.
See Page 4.
Left hand door-LH
Right hand door-RH
FOR CUSTOMER CARE CALL TOLL FREE 800-562-5625 or [email protected]
PAGE 2
Components:
It is recommended that the door be hung on ball bearing type hinges so door swings freely.
A separate door stop (supplied by others) is recommended to prevent damage to the door closer, closer arm, the door, frame or adjacent walls.
Door and frame must be properly reinforced or through bolts used to prevent the mounting screws from pulling out.
Figure 1
Figure 2
Fasteners Door or Frame Drill Sizes Where Used
Self Drilling/Tapping
Machine Screw
Hollow Metal or
Aluminum
3/16" Closer
1/4"-20 Machine Screw
Hollow Metal or
Aluminum
#7 (.201") Drill bit & 1/4"-20
Tap
Closer & Parallel Arm
(PA) Plate / Foot
Wood Screw Wood
5/32" Drill Bit – Softwood
3/16" Drill Bit – Hardwood
* Measure door thickness before drilling pilot holes to prevent drilling through opposite side
Closer & PA Plate / Foot
1/4"-20 Machine Screw
used with Through Bolt
Hollow Metal or
Aluminum
Wood
9/32" Drill Bit Closer Side &
3/8" Drill Bit Opposite Side
Closer
*Drill Depth
Through one side
5/8" – Closer
1/2" – PA Plate/Foot
1-1/4"
9/32" – Through Door
3/8" – 1/2"
Preparation for Fasteners
Latch Speed
Valve
Sweep Speed Valve
Backcheck Valve
Standard Closer
Mounting Plate
For mounting plate installation,
refer to supplemental installation sheet.
Closer Arm
Main Arm
Forearm
Forearm Screw
Forearm
Shoe
Forearm Shoe
Screw
Main Arm Screw
Plastic Cover
Through Bolt and Screw
Screw Package
Parallel Arm Plate
REGULAR ARM INSTALLATION
UH4061 & UH4062 INSTALLATION INSTRUCTIONS
FOR CUSTOMER CARE CALL TOLL FREE 800-562-5625 or [email protected]
PAGE 3
D
E
C
R
E
A
S
E
Right hand door shown
To 100°
To 130°
To 180°
7-1/2" (191 mm)
6" (152 mm)
4-1/2" (114 mm)
To increase power
turn clockwise 13 turns maximum
To decrease power
turn counterclockwise
INSTALLATION SEQUENCE
1. Select degree of opening and use dimensions shown to locate 4 holes on
door for closer body and 2 holes on frame face for forearm shoe.
2. Prepare door and frame for fasteners (See Preparation for Fasteners,
Page 2, Figure 2).
3. Before installing closer body, set spring power for closer using Power
Adjustment Chart below.
4. Install closer on door with speed regulating valves towards the hinge.
5. Disassemble forearm from main arm by removing forearm screw (See
Figure 1). Fasten forearm shoe and forearm to frame face.
6. Mount main arm onto closer pinion shaft, aligning arm mark "S" with
pinion at. Secure with main arm screw.
7. Reassemble arm. Adjust forearm length so that it will be perpendicular
(at a 90° angle) to the door face. Secure with forearm screw.
8. Adjust closer (See page 6) and install cover.
Opening
Dimensions "A"
24" - 30"
(61 cm - 76 cm)
30'' - 34"
(76 cm - 86 cm)
34" - 38"
(86 cm - 97 cm)
38" - 48"
(97 cm - 122 cm)
48" - 54"
(122 cm - 137 cm)
54" - 60"
(137 cm - 152 cm)
NOTE: Maximum of 20 turns (360°) of power adjustment nut.
Closer is shipped at 7 turns from the factory.
-7
-3
0
4
8
13
-5
0
4
8
13
Full clockwise turns of closer power adjustment
nut (from "0" turns)
INTERIOR
DOOR
EXTERIOR
DOOR
DOOR SIZE
(INCHES)
Power Adjustment Chart
I
N
C
R
E
A
S
E
Door
Swing
L & S
Valves
Main Arm
Preload
L & S
Valves
Main Arm
Preload
Right Hand Door
Left Hand Door
90°
90°
Pinion
Flat
Arm
Mark
Top View
12"
(305 mm)
3/4" (19 mm)
1-3/16" (30 mm)
1-3/16" (30 mm)
1-3/4" (44 mm)
5-1/2"
(140 mm)
"A"
of Hinge
C
L
HINGE
Main Arm Installation Instructions
TOP JAMB INSTALLATION
UH4061 & UH4062 INSTALLATION INSTRUCTIONS
FOR CUSTOMER CARE CALL TOLL FREE 800-562-5625 or [email protected]
PAGE 4
Left hand door shown
INSTALLATION SEQUENCE
1. Select degree of opening and use dimensions shown to locate 4 holes on
frame face for closer body and 2 holes on door for forearm shoe.
2. Prepare door and frame for fasteners (See Preparation for Fasteners,
Page 2, Figure 2).
3. Before installing closer body, set spring power for closer using Power
Adjustment Chart below.
4. Install closer on door with speed regulating valves towards the hinge.
5. Disassemble forearm from main arm by removing forearm screw (See
Figure 1). Fasten forearm shoe and forearm to door face.
6. Mount main arm onto closer pinion shaft, aligning arm mark "S" with
pinion at. Secure with main arm screw.
7. Reassemble arm. Adjust forearm length so that it will be perpendicular
(at a 90° angle) to the door face. Secure with forearm screw.
8. Adjust closer (See page 6) and install cover.
24" - 30"
(61 cm - 76 cm)
30'' - 34"
(76 cm - 86 cm)
34" - 38"
(86 cm - 97 cm)
38" - 48"
(97 cm - 122 cm)
48" - 54"
(122 cm - 137 cm)
54" - 60"
(137 cm - 152 cm)
NOTE: Maximum of 20 turns (360°) of power adjustment nut.
Closer is shipped at 7 turns from the factory.
-7
-3
0
4
8
13
-5
0
4
8
13
Full clockwise turns of closer power adjustment
nut (from "0" turns)
INTERIOR
DOOR
EXTERIOR
DOOR
DOOR SIZE
(INCHES)
Power Adjustment Chart
D
E
C
R
E
A
S
E
I
N
C
R
E
A
S
E
To 100°
To 130°
To 180°
7-1/2" (191 mm)
6" (152 mm)
4-1/2" (114 mm)
Opening
Dimensions "A"
Main Arm Installation Instructions
Top View
Pinion Flat
Arm Mark
12"
(305 mm)
5-1/2"
(140 mm)
3/4"
(19 mm)
"A"
1-7/8"
(30 mm)
1-3/4" (44 mm)
1/2"
(13 mm)
HINGE OPPOSITE SIDE
of Hinge
C
L
To increase power
turn clockwise 13 turns maximum
To decrease power
turn counterclockwise
90°
Left Hand Door
90°
Main Arm
Preload
L & S
Valves
L & S
Valves
Door
Swing
Right Hand Door
PARALLEL ARM INSTALLATION
UH4061 & UH4062 INSTALLATION INSTRUCTIONS
FOR CUSTOMER CARE CALL TOLL FREE 800-562-5625 or [email protected]
PAGE 5
Left hand door shown
Opening
Dimensions "A"
To 120°
To 180°
9-1/2"
7"
Dimensions "B"
3-3/4" (95 mm)
1-1/4" (32 mm)
Use adjustable wrench to rotate spindle 45° counter-clockwise for right hand
door or clockwise for left hand door. Place main arm on spindle so that the "R"
(Right hand door) or "L" (Left hand door) lines up with spindle at. Secure main
arm and spindle by tightening spindle bolt.
Main Arm Installation Instructions
INSTALLATION SEQUENCE
1. Select degree of opening and use dimensions shown to locate 4 holes on
door for closer body and 4 holes underside of frame for PA plate.
2. Prepare door and frame for fasteners (See Preparation for Fasteners,
Page 2, Figure 2).
3. Before installing closer body, set spring power for closer using Power
Adjustment Chart below.
4. Install closer on door with power adjustment value towards the hinge.
5. Mount parallel arm plate to frame. Disassemble forearm from main arm
by removing forearm screw. Remove forearm shoe from forearm and
attach forearm to parallel plate with forearm shoe screw (See Figure 1).
6. Install main arm on pinion shaft (See Main Arm Installation Instructions,
to right.).
7. Reassemble main arm to forearm. Preload is accomplished by adjusting
forearm length so that it will set arm elbow about 1-1/2" (38mm) from the
door face when connected to the main arm. Secure with forearm screw.
8. Adjust closer (See page 6) and install cover.
24" - 30"
(61 cm - 76 cm)
30'' - 34"
(76 cm - 86 cm)
34" - 38"
(86 cm - 97 cm)
38" - 48"
(97 cm - 122 cm)
48" - 54"
(122 cm - 137 cm)
NOTE: Maximum of 20 turns (360°) of power adjustment nut.
Closer is shipped at 7 turns from the factory.
-4
0
6
12
0
5
10
Full clockwise turns of closer power adjustment
nut (from "0" turns)
INTERIOR DOOR EXTERIOR DOOR
DOOR SIZE
(INCHES)
Power Adjustment Chart
D
E
C
R
E
A
S
E
I
N
C
R
E
A
S
E
Pinion Flat
Arm MarkArm Mark
Pinion Flat
1-1/2"
38mm
Door
Swing
Right Hand Door
Left Hand Door
Power
Adjustment
Power
Adjustment
Top View
12"
(305 mm)
3/4"
(19 mm)
"B"
3-1/2"
(89 mm)
HINGE OPPOSITE SIDE
FRAME
"A"
7/16"
(11 mm)
2-3/4"
(70 mm)
2"
(51 mm)
of Hinge
C
L
1/2"
(13 mm)
DOOR
HINGE
FRAME
To increase power
turn clockwise 13 turns maximum
To decrease power
turn counterclockwise
FOR CUSTOMER CARE CALL TOLL FREE 800-562-5625 or [email protected]
PAGE 6
Closer Adjustment
Closing Speed Controls (Figures 1 and 2)
Valve "S" controls sweep range
Valve "L" controls latch range
Closing Power Control (Figure 3)
Adjusted as required (see charts on pages 3, 4, & 5)
Opening Door Control (Figures 4 and 5)
Backcheck Valve controls the hydaulic resistance to door opening.
Never close this valve completely — it is not to provide a position stop.
s
w
e
e
p
r
a
n
g
e
o
p
e
n
i
n
g
b
a
c
k
c
h
e
c
k
Closing Speed Controls Figure 1
Standard Closing cycle
Closed
Latch
10°
Opening cycle
"S" (sweep)"L" (latch)
Opening Door Controls Figure 4
D
E
C
R
E
A
S
E
I
N
C
R
E
A
S
E
Closing Speed Controls Figure 2
Backcheck Figure 5
(backcheck)
(NEVER close backcheck valve completely)
spindle
Closing Power Control Figure 3
©2015 Hampton Products International Corp.
50 Icon, Foothill Ranch, CA 92610-3000 USA
www.universalhardware.com • 1-800-562-5625
91000_UH4061-62_REVA
05/15 #95049000
F
A
S
T
S
L
O
W
F
A
S
T
S
L
O
W
D
E
C
R
E
A
S
E
I
N
C
R
E
A
S
E
To increase power
turn clockwise 13 turns maximum
To decrease power
turn counterclockwise
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Universal Hardware UH4062 Operating instructions

Type
Operating instructions
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI