FlexPoint
1208-F / 1232-D / 1250-D Power Supplies Quick Start Guide
Fig. 1, System Block Diagram
Review the drawings and illustrations contained in this guide before proceeding. For additional details on installation
and operation, visit www.alpha.com and download a copy of the FlexPoint
TM
1208-F / 1232-D / 1250-D Series
Technical Manual (p/n 010-353-B9).
The FlexPoint 1232-D and 1250-D power supplies are designed to provide power to both an optical network terminal
(ONT) and a micro-node. These power supplies are able to provide a total of 32W and 50W (respectively), via
the 7-pin connector. When the F-type connector is used in conjunction with the 7-pin connector, power will be split
between outputs with a maximum of 8W delivered via the coaxial connector, and the balance of the unit’s power
available on the 7-pin connector. A customer-provided 90Vac to 264Vac, 50/60Hz power receptacle provides primary
power to the input of the unit. The AC voltage is then converted to a usable 12Vdc output. Backup power is provided
by batteries that are long life, easy to replace, purchase, and install. Power status is provided to the customer via
audible alarms and visual indicators. Upon loss of AC service, the duration of standby power is determined by the
battery installed in the unit.
1. Unpack and inspect the FlexPoint power supply.
2. Install the unit within 8' (2.4 m) to an AC outlet with 6" (15.2 cm) of space above and below, 2–4" (5–10 cm)
in front and 2" (5 cm) of space on either side to provide adequate thermal ventilation.
3. Remove battery compartment cover by pressing the nger tab underneath the middle of the unit and pull
the cover bottom away from the unit and down.
4. Determine the necessary cable length to provide appropriate service loops between the unit, the ONT, and
the AC receptacle. Plug the line cord into the receptacle in the unit. Secure line cord at one of the cable
tie holes with one included cable tie. Do not plug the unit into an AC receptacle until the last step of the
installation procedure.
5. Connect coax cable to F-type connector, torque to between 4.1 in-lbs and 6.1 in-lbs, and secure in cable
dressing holes. Secure output cable at one of the cable tie holes with one of the included cable ties.
6. Mount to the wall with #12 fasteners or equivalent, using the keyholes for easy mounting. For applications
with higher seismic requirements, use the round hole in the back of the unit for direct fastening to a stud or
other structural feature.
Installing and connecting the FlexPoint unit
The unit is designed for use in an indoor environment protected from moisture. Its operating
temperature range is -10°C to 45°C / 14°F to 113°F (ambient).
The power supply cord is used as the main disconnect device. Verify the AC receptacle is
located/installed near the equipment and is easily accessible.
CAUTION!
ONT
Line Cord Up to 8',
(2.4 meters)
Network
Area
Customer
Area
FlexPoint 1208-F
F-Type Connector
FlexPoint: Up to 50' (~15.25 meters)
AUX
SILENCE
ALARM
DC START
During normal operation, press the Silence Alarm button to get the recommended battery capacity:
5Ah – 1 chirp; 7Ah – 3 chirps; 8Ah – 4 chirps.
NOTICE:
FlexPoint specications
Input
AC Input Voltage: 90–264Vac
AC Input Frequency: 50/60Hz
Connection: IEC 320-C6 3-Prong with cable ties to prevent accidental removal of the line cord.
Surge Protection:
Standards Level
Telcordia GR-1089
ANSI/IEEE C62.41
IEC 61000-4-5
1.2x50us combination wave at, 2kV
Output per model 1208-F 1232-D 1250-D
Operational Output Power (ONT Load): 8W max. continuous 32W max. continuous 50W max. continuous
Output Voltage: 12Vdc nominal 12Vdc nominal 12Vdc nominal
Connection: RF connector 7-position connector and
F-type coaxial connector
7-position connector and
F-type coaxial connector
Mechanical Dimensions
Unit Dimensions for 5,7.2 or 8Ah Battery
L x W x D (in/mm):
6.6 x 7.5 x 3.2 / 167.6 x 190.5 x 81.3
Unit Weight without Battery (lb/kg): 1.2 / 0.54 1.3 / 0.59 1.35 / 0.61
5.1Ah Battery Weight (lb/kg): 3.9 / 1.8
7.2Ah Battery Weight (lb/kg): 5.7 / 2.6
8.0Ah Battery Weight (lb/kg): 5.73 / 2.7
Estimated Battery Runtimes
1208-F 1232-D 1250 -D
1.5W load 4W load 16W load 32W load 36W load 50W load
5.1Ah Battery (Hrs): 34.2 12.7 2.5 1.1 0.9 0.7
7.2Ah Battery (Hrs): 54.4 20.0 3.9 1.6 1.4 1.0
8.0Ah Battery (Hrs): 60.7 22.4 4.7 2.0 1.7 1.1
Battery Type: Maintenance free, leak-proof, sealed VRLA (valve regulated lead acid)
Visual Indicators
AC Power: Green LED on: AC power present and powering the ONT
Battery: Green LED on: Battery powering ONT during AC loss
Green Flashing: Battery powering ONT during AC loss and running low
Replace Battery: Red LED off: Battery present and working correctly
Red LED on: Replace battery / battery missing
Mute Green LED on: Lit when Silence Alarm button is pressed
Replace Power Supply: Green LEDs ashing
Audible Status Indicators
Loss of Input Power: Single, one second chirp
Low Battery: Single chirp every 15 seconds
Replace Battery: Double chirp every 15 minutes
Push Buttons
DC Start: Press and hold when unit is off to start up on battery without AC present
Silence Alarm: When any audible alarm is on, press this key for at least 1 second and release to silence the
audible alarm.
During normal operation, press the Silence Alarm button to get the recommended battery capacity:
5Ah – 1 chirp; 7Ah – 3 chirps; 8Ah – 4 chirps.
FlexPoint 1232-D, 1250-D
7-position output cable (Class 2 wiring)
and an F-type Connector
Alpha Technologies 3767 Alpha Way Bellingham, WA 98226 USA Tel: +1 360 647 2360 Fax: +1 360 671 4936 www.alpha.com
Alpha Technologies Ltd. 7700 Riverfront Gate Burnaby, BC, V5J 5M4 CANADA Tel: +1 604 436 5900 Fax: +1 604 436 1233
Due to continuing product improvements, Alpha reserves the right to change specications without notice.
Copyright © 2015 Alpha Technologies, Inc. All rights reserved. Alpha is a registered trademark of Alpha Technologies.
010-353-B8-001 Rev. B (06/2015)
7.48"
[190.0 mm]
3.19"
[81.0 mm]
4.23"
[107.4 mm]
6.57"
[166.9 mm]
2.52"
[64.0 mm]
2.83"
[71.9 mm]
4.29"
[108.9 mm]
3.23"
[82.0 mm]
(Cover removed for clarity)
Battery installation / Battery replacement procedure
1. Press nger tab to release battery cover and connect the wire harness to the battery.
2. Install the battery into the compartment ensuring the battery retaining clip secures the battery (for
batteries up to 8Ah).
3. Replace the battery cover.
4. Plug the unit into AC power. The green AC PRESENT LED should illuminate.
5. Verify proper function by unplugging the AC line cord from the AC receptacle. Within approximately 30
seconds the alarm should sound for 1 second (it may take longer to trigger this alarm if the load is very
light or not connected). AC mode LED (Green) will display then turn off and the ON-BATTERY LED
(Green) will illuminate.
6. Reconnect the unit to an AC receptacle (if no AC power is present and if the battery is installed, press DC
start button for 2 seconds). The unit is ready to be placed into service.
Risk of explosion if battery is replaced by an incorrect type. Recycle spent batteries in
accordance with local regulations.
WARNING!
FlexPoint Audible alarms/Visual indicators
010-353-B8-001 Rev. B (06/2015)
AUX
SILENT
ALARM
DC START
AUX
SILENT
ALARM
DC START
AUX
SILENCE
ALARM
DC START
AUX
SILENCE
ALARM
DC START
AUX
SILENCE
ALARM
DC START
AUX
SILENCE
ALARM
DC START
AUX
SILENCE
ALARM
DC START
AUX
SILENCE
ALARM
DC START
AUX
SILENCE
ALARM
DC START
AUX
SILENCE
ALARM
DC START
AUX
SILENCE
ALARM
DC START
AUX
SILENCE
ALARM
DC START
AUX
SILENCE
ALARM
DC START
AUX
SILENCE
ALARM
DC START
2
Condition Status LED Audible Alarm Description
AC PRESENT
LED (Green)
steady ON
N/A Condition normal; AC powers load, charges battery.
ON BATTERY
LED (Green)
steady ON
1 second beep on loss
of AC
Input fails; battery powers load.
LOW BATTERY
LED (Green)
ashing
1 beep every 15
seconds
Alarm is triggered when AC fails and battery is
running low (<11.7 V).
REPLACE
POWER SUPPLY
LEDs (Green)
ashing
N/A
If both Green LEDs are ashing, the power supply
needs to be replaced.
REPLACE BATT
LED (Red)
steady ON
2 beeps, every
15 minutes
The unit automatically initiates a battery test every
180 days. If the unit fails the test, this alarm is
triggered.
BATT MISSING
LED (Red)
steady ON
N/A
The alarm is triggered when the battery is not
installed or not connected.
MUTE
LED (Green)
steady ON
N/A
Green LED is lit when Silence Alarm button is pressed
and an audible alarm is active.
Mounting holes for customer-supplied #12 hardware or equivalent
Keyhole slots for easy mounting
1
2
Always mount unit vertically as shown in Fig. 2.
NOTICE:
Table 2, FlexPoint battery options
2
2
1
Battery Options
Part Description
AX-STDBAT-5 Battery 5.1Ah AGM, 1-year Warranty
AX-STDBAT-7 Battery 7.2Ah AGM, 1-year Warranty
AX-LONGBAT-7 Battery 7.2Ah AGM, 3-year Warranty
AX-LONGBAT-8 Battery 8Ah AGM, 3-year Warranty
Fig. 2, FlexPoint Dimensions (in/[mm])
(viewed from back/right side)
Fig. 3, FlexPoint AC input, DC output power connector locations
Coaxial connector
7-pin output
cable connector
Table 1, 7-pin connector and pin-outs
Pin Connection Wire Gauge
1 Positive (+) 16AWG
2 Negative (-) 16AWG
3 Signal Return 24AWG
4 AC failure 24AWG
5 Replace Battery 24AWG
6 Battery Missing 24AWG
7 Battery Low 24AWG
7
1
Line cord
connector
Coaxial
connector
Line cord
connector
FlexPoint 1208-F FlexPoint 1232-D, 1250-D
  • Page 1 1
  • Page 2 2

Alpha FlexPoint 1208-F RFoG Quick start guide

Category
Security device components
Type
Quick start guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI