Thermo Fisher Scientific Pierce Background Eliminator User guide

Type
User guide
INSTRUCTIONS
Pierce Biotechnology
PO Box 117
(815) 968-0747
www.thermoscientific.com/pierce
3747 N. Meridian Road
Rockford, lL 61105 USA
(815) 968-7316 fax
Number Description
21065 Pierce Background Eliminator
Kit Contents:
Reagent A, 100mL
Reagent B, 100mL
Storage: Upon receipt store at room temperature. Product shipped at ambient temperature.
Introduction
Thermo ScientificPierce Background Eliminator allows background to be removed from overexposed film after it has
been developed. This product is the ideal solution for researchers who want to visualize images that may be difficult to
discern because of high background, overexposed bands or speckling without spending valuable time repeating experiments
or trying to time the exposure precisely. Pierce Background Eliminator Solution will produce clear images from
Western/Southern/Northern blots, gel shifts or any other assay that requires film to capture an image (Figure 1). For
applications requiring densitometry measurements, the process reduces signal intensity evenly across the entire film so that
relative densitometry values are consistent.
Pierce Background Eliminator works on freshly developed films or films that have been stored for years. The working
solution can be used at room temperature and does not need to be used in the darkroom. The entire process takes only a few
minutes and may be stopped when the exposure looks just right.
Procedure for Using Pierce Background Eliminator
1. Thoroughly wash developing chemicals from film.
2. Place two containers of deionized water nearby for rinsing film. Containers must be large enough to fully submerge film.
3. Prepare Working Solution immediately before use by adding Reagent A and Reagent B to deionized water in the
amounts indicated below. The Working Solution is stable for up to 30 minutes.
Film Size
Container Size
Reagent A
Reagent B
5” × 7”
8” × 8” × 2”
10mL
10mL
8” × 10”
8”× 10” × 2”
20mL
20mL
4. Add freshly prepared Working Solution to a glass or plastic container large enough to fully submerge film.
5. Place one film in the Working Solution and rock container. Make sure film does not stick to container bottom. Flip film
over every 15-30 seconds.
6. Remove film when desired image appears.
Note: Monitor film closely or desired image may be erased. Erasing background over a light box may help visualize the
progress.
7. Immediately submerge film in the first water rinse for a few seconds. The solution continues to erase until the film is
removed.
8. Remove film from first water rinse and place in second water rinse. Make sure to thoroughly wash film.
9. Allow film to dry.
1339.2
21065
PierceBackground Eliminator
Pierce Biotechnology
PO Box 117
(815) 968-0747
www.thermoscientific.com/pierce
3747 N. Meridian Road
Rockford, lL 61105 USA
(815) 968-7316 fax
2
A
B
Troubleshooting
Problem
Cause
Solution
Background is not removed
evenly across the entire film
Film stuck to the container bottom or not
flipped consistently
Rock container during incubation and flip
film every 15-30 seconds
More than one film was incubated in the
Working Solution
Incubate only one film at a time
Image disappears too quickly
Working Solution was too concentrated
Working Solution may be diluted to slow
reaction
Not sure when to stop the
reaction
Difficult to determine when results are
optimal
Stop reaction and photograph data at several
time-points
Note: Film can be repeatedly incubated in
the Working Solution
Working Solution no longer
removes background
Saturation or depletion of Working
Solution
Use more newly prepared Working Solution
Reagent B has darkened with
time
Normal reagent property
Reagent will function properly
Yellow tint on film
Inadequate washing
Thoroughly wash film to remove excess
Working Solution
Extremely dark film saturated or
depleted the Working Solution
Use more newly prepared Working Solution
Use only one piece of film at a time
Related Thermo Scientific Products
34090 CL-XPosure™ Film, 5” × 7” sheets, 100 sheets/pkg
32106 Pierce ECL Western Blotting Substrate, 500mL
34080 SuperSignal West Pico Chemiluminescent Substrate, 500mL
34075 SuperSignal West Dura Substrate, 100mL
34095 SuperSignal West Femto Maximum Sensitivity Substrate, 100mL
33500 Pierce In-Gel Chemiluminescent Detection Kit Rabbit
33505 Pierce In-Gel Chemiluminescent Detection Kit Mouse
20148 LightShift™ Chemiluminescent EMSA Kit
Figure 1. Recombinant Human TNFα was separated by SDS-PAGE using a 4-20% gel
and transferred to a nitrocellulose membrane. The membrane was blocked and detected
with mouse anti-Human TNFα followed by Goat anti-Mouse-HRP (Product No. 31434) and
Thermo ScientificSuperSignalWest Dura Substrate (Product No. 34075). The blot was
exposed to film for 30 seconds, resulting in considerable background speckling (A). The film
was then treated with Pierce Background Eliminator for 2 minutes (B).
Pierce Biotechnology
PO Box 117
(815) 968-0747
www.thermoscientific.com/pierce
3747 N. Meridian Road
Rockford, lL 61105 USA
(815) 968-7316 fax
3
Products are warranted to operate or perform substantially in conformance with published Product specifications in effect at the time of sale, as set forth in
the Product documentation, specifications and/or accompanying package inserts (“Documentation”). No claim of suitability for use in applications regulated
by FDA is made. The warranty provided herein is valid only when used by properly trained individuals. Unless otherwise stated in the Documentation, this
warranty is limited to one year from date of shipment when the Product is subjected to normal, proper and intended usage. This warranty does not extend to
anyone other than Buyer. Any model or sample furnished to Buyer is merely illustrative of the general type and quality of goods and does not represent that
any Product will conform to such model or sample.
NO OTHER WARRANTIES, EXPRESS OR IMPLIED, ARE GRANTED, INCLUDING WITHOUT LIMITATION, IMPLIED WARRANTIES OF
MERCHANTABILITY, FITNESS FOR ANY PARTICULAR PURPOSE, OR NON INFRINGEMENT. BUYER’S EXCLUSIVE REMEDY FOR NON-
CONFORMING PRODUCTS DURING THE WARRANTY PERIOD IS LIMITED TO REPAIR, REPLACEMENT OF OR REFUND FOR THE NON-
CONFORMING PRODUCT(S) AT SELLER’S SOLE OPTION. THERE IS NO OBLIGATION TO REPAIR, REPLACE OR REFUND FOR PRODUCTS
AS THE RESULT OF (I) ACCIDENT, DISASTER OR EVENT OF FORCE MAJEURE, (II) MISUSE, FAULT OR NEGLIGENCE OF OR BY BUYER,
(III) USE OF THE PRODUCTS IN A MANNER FOR WHICH THEY WERE NOT DESIGNED, OR (IV) IMPROPER STORAGE AND HANDLING OF
THE PRODUCTS.
Unless otherwise expressly stated on the Product or in the documentation accompanying the Product, the Product is intended for research only and is not to
be used for any other purpose, including without limitation, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses, or
any type of consumption by or application to humans or animals.
Current product instructions are available at www.thermoscientific.com/pierce. For a faxed copy, call 800-874-3723 or contact your local distributor.
© 2013 Thermo Fisher Scientific Inc. All rights reserved. All (other) trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries.
Printed in the USA.