Table of Contents
Revision History .............................................................................................. 1
Introduction .................................................................................................... 1
1. Specifications ..................................................................................................... 2
2. Overview ............................................................................................................ 3
2.1. Name of Parts .......................................................................................................3
2.2. Block Diagram ......................................................................................................4
2.3. Power Supply ........................................................................................................4
2.4. Clock ......................................................................................................................4
2.5. I/O ..........................................................................................................................5
2.6. Setting Switch ......................................................................................................6
2.7. USB Controller (FT600) ......................................................................................6
2.8. USB Controller (FT232H) ...................................................................................7
3. FPGA Configuration ........................................................................................... 8
3.1. Using Original Tool ..............................................................................................8
3.2. Using JTAG Download cable ...............................................................................8
3.3. Using Configuration Device ................................................................................9
4. Device Driver ..................................................................................................... 9
5. Factory Setting of FT2232H EEPROM ............................................................. 10
6. Documentation and User Support .................................................................... 11
Precautions
Do Not
1. This product uses ordinary off-the-shelf electronic components, and is therefore inappropriate for use in
applications that require special quality or reliability and are expected to protect human lives or prevent
accidents, such as safety mechanisms in fields including space, aeronautics, medicine, and nuclear
power.
2. Do not be used underwater or in high-humidity environments.
3. Do not be used in the presence of corrosive gases, combustible gases, or other flammable gases.
4. Do not turn on power when circuit board surface is in contact with other metal.
5. Do not apply voltage higher than rated voltage.
Attention
6. This manual may be revised in the future without notice owing to improvements.
7. All efforts have been made to produce the best manual possible, but if users notice an error or other
problem, we ask that they notify us.
8. Item 7 notwithstanding, HuMANDATA cannot be held liable for the consequences arising from use of
this product.
9. HuMANDATA cannot be held liable for consequences arising from using this product in a way different
from the uses described herein, or from uses not shown herein.
10. This manual, circuit diagrams, sample circuits, and other content may not be copied, reproduced, or
distributed without permission.
11. If the product emits smoke, catches fire, or becomes unusually hot, cut the power immediately.
12. Be careful of static electricity.
13. This product may be subject to the export restrictions of Japan, the United States, or other countries.
Purchasers are responsible for properly observing export restrictions.
14. HuMANDATA firmly refuses to export (including reexporting) products to countries or regions subject to
export restrictions.
Product Warranty and Scope of Support
1. HuMANDATA guarantees that its products can be assembled as shown in published circuit diagrams and other design documents.
There may be differences between actual components or their prescribed quantities and model numbers and those shown in circuit
diagrams.
2. Except for the guarantee in item 1, above, no guarantees whatsoever are made. When assembling the product as shown in a circuit
diagram is impossible, and the problem can be solved by revising the diagram, HuMANDATA will revise the diagram. When a
problem can be solved only by replacing components or modifying the product, HuMANDATA will take back the product to replace it
with a properly functioning product.
3. In case item 2, above, HuMANDATA guarantee its products for a period of 60 days from the date of shipping.
4. If the problem is minor, HuMANDATA will sometimes describe how to make the revision or modification, and ask the customer to
solve the problem.
5. HuMANDATA will determine how to honor the warranty, as through repair, replacement, return, or other action. The customer cannot
specify what action to take.
6. FPGAs and other components used in products sometimes have characteristic defects. Returns and replacements are not possible
even if such defects are discovered, whether before or after purchase.
7. HuMANDATA shall not be obligated to inform customers about defects in the main components used in products.
8. HuMANDATA shall not be obligated to provide support for products, or to provide support for the software of other companies
needed to use HuMANDATA products.
9. Published documentation shall be limited to that published by HuMANDATA at the time of product purchase, and HuMANDATA shall
not be obligated to provide any other documentation.
10. When repairs or replacements are provided under warranty in Japan, purchaser shall pay shipping charges for shipping to
HuMANDATA, and HuMANDATA shall pay shipping charges for shipping to purchaser.
11. When shipping from outside of Japan, purchaser shall pay all expenses including shipping charges and taxes.
12. Under whatever circumstances, HuMANDATA shall provide support for its products for a maximum of one year after shipping from
factory.
13. The Warranty is not applicable and support ends in the event of fire, storm and flood damage, earthquakes, lightning strikes, and
other natural disasters, as well as conflict or other occurrences.
14. Purchaser is assumed to have read and understood all the above when purchasing a HuMANDATA product.
Limitation of Liability
1. Purchasers assume all liability associated with the use of this product.
2. HuMANDATA assumes no liability whatsoever for any direct, indirect, special, incidental, or consequential damages arising from the
use of this product, even if HuMANDATA has been advised of the possibility of such damage, whether legal or in tort.
3. At the time this product is purchased, items 1 and 2 above shall be deemed to have been confirmed by purchaser.
Trademarks and Other Considerations
1. This manual uses various companies’ trademarks in places.
2. HuMANDATA is this company’s registered trademark.
HuMANDATAs Philosophy
1. HuMANDATA endeavors to raise product quality. We continually make detailed improvements and adjustments that are not shown
in circuit diagrams.
2. HuMANDATA actively publishes, on the Web and in other ways, information considered useful to customers. Examples would be
how to use FPGAs and how to use development tools.
3. HuMANDATA makes efforts for the long-term provision of products and for continuing their long-term support.
4. Instead of concealing small product problems and documentation errors, HuMANDATA makes them public.
5. HuMANDATA abides by Japanese law and its spirit. We make no transactions with purchasers who commit illegal acts.
1
EDA-009 v1.0
Revision History
Date
Revision
Description
June. 8, 2016 v1.0 Initial release
Introduction
Thank you for purchasing our product EDA-009.
EDA-009 is a USB-FPGA board with USB interface equipped with ALTERA FPGA
Cyclone V series and FTDI's USB controller FT600.
By using the original configuration tool “BBC[EDA-009]”, no download cable or
ALTERA developing environment is needed to configure FPGA and configuration
device on the board.
2
EDA-009 v1.0
1. Specifications
Model Name
EDA-009
FPGA
5CEBA4F23C8N
USB 3.0 Controller
FT600 (FTDI)
USB 2.0 Controller
FT232H (FTDI)
Config. Device
N25Q032 (Micron, 32Mbit)
Power Input
DC 5.0 [V]
(Internal power is generated by on-board regulator)
On-Board Clock
50 [MHz]
User LED
2
User Switch
2 (Push x 1, DIP x 1bit)
Status LED
Power (red) x1, Done (blue) x1
Power-On Reset
240 [ms] typ. (Config. reset signal)
User I/Os
66-pin through-hole
dia. 0.9 (typ.) [mm], 100[mil]/2.54 [mm] pitch
JTAG Connector
DIL 10-pin socket, 2.54 [mm] pitch
PCB
6 Layer FR-4 t1.6 [mm] Immersion gold
Dimensions
3.386" x 2.126" (86 x 54 [mm])
Weight
34 [g] typ.
Accessories
DIL10 long pin header (Mounted) x1
DIL80 pin header x 2
USB 3.0 cable (1.0m) x 1
RoHS Compliance
YES
* There may be cases that these parts and specifications are changed.
3
EDA-009 v1.0
2. Overview
2.1. Name of Parts
Component Side
Solder Side
DONE LED
POWER LED
Setting Jumper
Setting SW
User SW
USB
Connector
FPGA
JTAG
Oscillator
User LEDs
User SW
3.3V Output
Setting Jumper
4
EDA-009 v1.0
2.2. Block Diagram
JTAG
Config. Device
JTAG
Buffer
C o nfig.
User
User I/Os CNB
User I/Os CNA
VIO(B) INPUT
5.0 V INPUT
Cyclone V
5CEBA4F23C8N
Power LED (3.3V)
Power Circuit
3.3V, 2.5V, 1.1V
User Switch
2
User LED
Config. Switch
Done LED
USB
3.0
3 .3V Output (Option)
5.0 V INPUT
Oscillator
50
MHz
50
EDA-009 Rev.C
.jic
High Speed
USB Bridge
FT232H
Super Speed
USB Bridge
FT600
50
User
2
2.3. Power Supply
This board operates from single DC 5.0 V power supply from user I/O pins number
3 and 4 of CNA and CNB connector. The external power supply should be sufficient
and stabilized. USB bus power is not supported.
2.4. Clock
A 50 MHz oscillator (U4) is equipped as an on-board clock.
Some user I/O pins can be used for clock input pins.
For more details, please refer to the circuit schematics.
5
EDA-009 v1.0
2.5. I/O
FPGA banks are divided into two groups as follows. IOA*, I/Os of CNA, are belongs
to BANK Group A. Power supply for I/Os is fixed to on-board 3.3V.
IOB*, I/Os of CNB, are belongs to BANK Group B. Power supply for I/Os, VIO(B),
is connected to on-board 3.3V, but external input also be available.
FPGA BANK Vccio BANK Group
3A
V33A
A
3B
V33A
A
4A
V33A
A
5A
V33A
A
5B
V33A
A
7A
VIO(B)
B
8A
VIO(B)
B
When you use external VIO(B) from CNB pins 1 and 2,
please short JP1 pins 2 and 3, and remove JR2.
Component Side
Solder Side
You can output on-board 3.3V from CNA pins 1 and 2.
When you use this function, please short JR1.
Solder Side
3 2 1
1 2 3
6
EDA-009 v1.0
2.6. Setting Switch
You can use SW2 to set a configuration mode of the FPGA.
Configuration Mode
1
2
MSEL
User
PS
ON
X
AS
OFF
X
ON: Low, X: Dont Care
PS mode : Configured by JTAG or original configuration tool
AS mode : Configured by configuration device.
2.7. USB Controller (FT600)
The FT600 is mounted on this board as a USB controller IC. FT600 is connected to
FPGA with 16 bit bus. It provides 1,600Mbps data through put (theoretical value).
Before FPGA is configured, FT232H is recognized by PC with priority. After
configuration, it is up to user. Please refer to the following table about control
signals.
Net Label FPGA Pin Function
XFT600RESET R10
Reset FT600
- FPGA High/Hi-Z : FT600 is reset
- FPGA Low : FT600 is active
XUSB2SEL R11
Change USB 2.0 signal connection
- FPGA High/Hi-Z : Connect to FT232H
- FPGA Low : Connect to FT600
When you need to make FT600 to be recognized by PC without FPGA configuration,
please short both of two pins of JP2. Normally, please set them to be opened.
Open (Factory Setting)
Short
7
EDA-009 v1.0
2.8. USB Controller (FT232H)
The FT232H is mounted on this board for FPGA configuration. You can also use it
as a user communication IC.
Before FPGA is configured, FT232H is recognized by PC with priority. After
configuration, it is up to user. Please refer to the following table about control
signals.
Net Label FPGA Pin Function
XFT232RESET AB5
Reset FT232H
- FPGA High/Hi-Z : FT232H is active
- FPGA Low : FT232H is reset
XUSB2SEL R11
Change USB 2.0 signal connection
- FPGA High/Hi-Z : Connect to FT232H
- FPGA Low : Connect to FT600
8
EDA-009 v1.0
3. FPGA Configuration
3.1. Using Original Tool
By using the original configuration tool “BBC[EDA-009]”, following function is
available without download cable.
FPGA configuration
Write and Erace configuration device
BBC[EDA-009] is available for free from a support page.
* The screenshot is based on the tool under development.
3.2. Using JTAG Download cable
Download cable is needed to use ALTERA tool (SignalTap II etc.). Pin assignment is
as follows.
CN2
Signal Name
JTAG Pin
Signal Name
TCK 1 2 GND
TDO
3
4
VCC
TMS 5 6 -
-
7
8
-
TDI 9 10 GND
9
EDA-009 v1.0
3.3. Using Configuration Device
Configuration data written in the configuration device will be configured to the
FPGA automatically when power is applied. To use this function, set configuration
mode to Active Serialmode.
Do not download inaccurate configuration data. It would damage the FPGA and
peripheral circuit.
4. Device Driver
To recognize USB controller, installing device driver is needed. The first time
EDA-009 is connected to a PC, installing it is required by Operation System.
The device driver and installation instruction are available from a support page.
FT600: displays as a "FTDI FT600 USB 3.0 Bridge Devicein universal serial bus
controller
FT232H: displays as a "EDA-009 VCPin universal serial bus controller, and as a
"EDA-009 (COM *)” in Port (COM and LPT)
Device driver for FT600 is available from the following FTDI web page.
http://www.ftdichip.com/Drivers/D3XX.htm
10
EDA-009 v1.0
5. Factory Setting of FT232H EEPROM
Factory presetting is as follows. The other items are not changed from the default.
11
EDA-009 v1.0
6. Documentation and User Support
The following documents and other supports are available at
http://www.hdl.co.jp/en/spc/EDA/eda-009/
Circuit Schematic
Pin List
Dimensional drawing
Net List
Original Configuration Tool BBC[EDA-009]”
Device Driver
Device Driver Installation Instruction
and more.
USB 3.0 with Cyclone V USB-FPGA Board
EDA-009 Series
Users Manual
Ver. 1.0. ...........................................June. 8, 2016
HuMANDATA LTD.
Address: 1-2-10-2F, Nakahozumi, Ibaraki
Osaka, Japan
ZIP 567-0034
Tel: 81-72-620-2002 (Japanese)
Fax: 81-72-620-2003 (Japanese/English)
URL: http://www2.hdl.co.jp/en/ (Global)
http://www.hdl.co.jp/ (Japan)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15

Humandata EDA-009 User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI