Extron DTP T HD2 4K 330 is a high-performance transmitter for sending HDMI signals up to 4K/60 at 4:4:4 over twisted pair cable. It supports long distance transmission up to 330 feet (100 meters) at 4K/60 and 460 feet (140 meters) at 1080p, and features EDID Minder, Key Minder, and HDCP. With its compact enclosure, the DTP T HD2 4K 330 can be surface mounted or used in an optional rack-mount kit.

Extron DTP T HD2 4K 330 is a high-performance transmitter for sending HDMI signals up to 4K/60 at 4:4:4 over twisted pair cable. It supports long distance transmission up to 330 feet (100 meters) at 4K/60 and 460 feet (140 meters) at 1080p, and features EDID Minder, Key Minder, and HDCP. With its compact enclosure, the DTP T HD2 4K 330 can be surface mounted or used in an optional rack-mount kit.

Safety Instructions
Safety Instructions • English
WARNING: This symbol, , when used on the product, is intended to
alert the user of the presence of uninsulated dangerous voltage within the
product’s enclosure that may present a risk of electric shock.
ATTENTION: This symbol, , when used on the product, is intended
to alert the user of important operating and maintenance (servicing)
instructions in the literature provided with the equipment.
For information on safety guidelines, regulatory compliances, EMI/EMF
compatibility, accessibility, and related topics, see the Extron Safety and
Regulatory Compliance Guide, part number 68-290-01, on the Extron website,
www.extron.com.
Instructions de sécurité • Français
AVERTISSEMENT: Ce pictogramme, , lorsqu’il est utilisé sur le
produit, signale à l’utilisateur la présence à l’intérieur du boîtier du produit
d’une tension électrique dangereuse susceptible de provoquer un choc
électrique.
ATTENTION: Ce pictogramme, , lorsqu’il est utilisé sur le produit, signale
à l’utilisateur des instructions d’utilisation ou de maintenance importantes
qui se trouvent dans la documentation fournie avec le matériel.
Pour en savoir plus sur les règles de sécurité, la conformité à la réglementation,
la compatibilité EMI/EMF, l’accessibilité, et autres sujets connexes, lisez les
informations de sécurité et de conformité Extron, réf. 68-290-01, sur le site
Extron, www.extron.com.
Sicherheitsanweisungen • Deutsch
WARNUNG: Dieses Symbol auf dem Produkt soll den Benutzer darauf
aufmerksam machen, dass im Inneren des Gehäuses dieses Produktes
gefährliche Spannungen herrschen, die nicht isoliert sind und die einen
elektrischen Schlag verursachen können.
VORSICHT: Dieses Symbol auf dem Produkt soll dem Benutzer in der
im Lieferumfang enthaltenen Dokumentation besonders wichtige Hinweise
zur Bedienung und Wartung (Instandhaltung) geben.
Weitere Informationen über die Sicherheitsrichtlinien, Produkthandhabung,
EMI/EMF-Kompatibilität, Zugänglichkeit und verwandte Themen finden Sie in
den Extron-Richtlinien für Sicherheit und Handhabung (Artikelnummer
68-290-01) auf der Extron-Website, www.extron.com.
Instrucciones de seguridad • Español
ADVERTENCIA: Este símbolo, , cuando se utiliza en el producto,
avisa al usuario de la presencia de voltaje peligroso sin aislar dentro del
producto, lo que puede representar un riesgo de descarga eléctrica.
ATENCIÓN: Este símbolo, , cuando se utiliza en el producto, avisa
al usuario de la presencia de importantes instrucciones de uso y
mantenimiento recogidas en la documentación proporcionada con el
equipo.
Para obtener información sobre directrices de seguridad, cumplimiento
de normativas, compatibilidad electromagnética, accesibilidad y temas
relacionados, consulte la Guía de cumplimiento de normativas y seguridad de
Extron, referencia 68-290-01, en el sitio Web de Extron, www.extron.com.
Инструкция по технике безопасности Русский
ПРЕДУПРЕЖДЕНИЕ: Данный символ, , если указан
на продукте, предупреждает пользователя о наличии
неизолированного опасного напряжения внутри корпуса
продукта, которое может привести к поражению электрическим
током.
ВНИМАНИЕ: Данный символ, , если указан на продукте,
предупреждает пользователя о наличии важных инструкций
по эксплуатации и обслуживанию в руководстве,
прилагаемом к данному оборудованию.
Для получения информации о правилах техники безопасности,
соблюдении нормативных требований, электромагнитной
совместимости (ЭМП/ЭДС), возможности доступа и других
вопросах см. руководство по безопасности и соблюдению
нормативных требований Extron на сайте Extron: www.extron.com,
номер по каталогу - 68-290-01.
安全说明 简体中文
警告 产品上的这个标志意在用户该产品机壳内有暴露的危压,
险。
意: 产品上的这个标志意示用户设备随的用户手中有
重要的操作和维护(维修说明
关于我们产品的安全指南、遵循的规范、EMI/EMF 的兼容性、无障碍
使用的特性等相关内容,敬请访问 Extron 网站 www.extron.com,参见
Extron 安全规范指南,产品编号 68-290-01
安全記事 繁體中文
警告 產品上使用此符號是為提醒使用產品機殼內存在著
能會導致觸電之風險的未絕緣危險電壓
注意 若產品上使用此符號是為提醒使用者
有關安全性指導方針、法規遵守、EMI/EMF 相容性、存取範圍和相關主題的詳
細資訊,請瀏覽 Extron 網站:www.extron.com,然後參閱《Extron 安全性與
法規遵守手冊》,準則編號 68-290-01。
安全上の注意 日本語
警告: この が製品上に表示されている場合は、筐体内に絶縁され
いない高電圧が流れ、感電の危険があるこています
注意:この 品上に表示されている場合は、機の取説明
記載されている重要な操作と保守()の示についてユーザーの
注意を起するものです
安全上の注意、法規厳守、EMI/EMF適合性、その他の関連項目
スト イト www.extron.com よ り Extron Safety
and Regulatory Compliance Guide』 ( P/N 68-290-01) をご覧ださい
안전 지침 한국어
경고: 이 기호 가 제품에 사용될 경우, 제품의 인클로저 내에 있는
접지되지 않은 위험한 전류로 인해 사용자가 감전될 위험이 있음을
경고합니다.
주의: 이 기호 가 제품에 사용될 경우, 장비와 함께 제공된 책자에 나와
있는 주요 운영 및 유지보수(정비) 지침을 경고합니다.
안전 가이드라인, 규제 준수, EMI/EMF 호환성, 접근성, 그리고 관련 항목에
대한 자세한 내용은 Extron 웹 사이트(www.extron.com)의 Extron 안전 및
규제 준수 안내서, 68-290-01 조항을 참조하십시오.
FCC Class A Notice
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to part15 of the FCC rules. The ClassA limits provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause interference. This interference must be corrected at
the expense of the user.
ATTENTION: The Twisted Pair Extension technology works with shielded twisted pair
(STP) cables only. To ensure FCC Class A and CE compliance, STP cables and STP
Connectors are also required.
For more information on safety guidelines, regulatory compliances, EMI/EMF
compatibility, accessibility, and related topics, see the “Extron Safety and
Regulatory Compliance Guide” on the Extron website.
Copyright
© 2015 Extron Electronics. All rights reserved.
Trademarks
All trademarks mentioned in this guide are the properties of their respective owners.
The following registered trademarks
®
, registered service marks
(SM)
, and trademarks
(TM)
are the property of
RGBSystems, Inc. or Extron Electronics:
Registered Trademarks
(®)
AVTrac, Cable Cubby, CrossPoint, DTP, eBUS, EDID Manager, EDID Minder, Extron, Flat Field, FlexOS, Global Configurator, GlobalViewer,
Hideaway, Inline, IPIntercom, IPLink, KeyMinder, LockIt, MediaLink, PlenumVault, PoleVault, PowerCage, Pure3, Quantum, SoundField,
SpeedMount, SpeedSwitch, SystemINTEGRATOR, TeamWork, TouchLink, V-Lock, VersaTools, VN-Matrix, VoiceLift, WallVault, WindoWall, XTP,
and XTPSystems
Registered Service Mark
(SM)
: S3 Service Support Solutions
Trademarks
(
)
AAP, AFL (Accu-RateFrameLock), ADSP(Advanced Digital Sync Processing), Auto-Image, CableCover, CDRS(ClassDRippleSuppression),
DDSP(Digital Display Sync Processing), DMI (DynamicMotionInterpolation), DriverConfigurator, DSPConfigurator, DSVP(Digital Sync
Validation Processing), eLink, EQIP, FastBite, FOX, FOXBOX, IP Intercom HelpDesk, LinkLicense, MAAP, MicroDigital, NetPA, ProDSP,
QS-FPC(QuickSwitch Front Panel Controller), Room Agent, Scope-Trigger, ShareLink, SIS, SimpleInstructionSet, Skew-Free, SpeedNav,
Triple-Action Switching, True4K, Vector, WebShare, XTRA, ZipCaddy, ZipClip
Conventions Used in this Guide
Notifications
The following notifications are used in this guide:
ATTENTION:
Risk of property damage.
Risque de dommages matériels.
NOTE: A note draws attention to important information.
TIP: A tip provides a suggestion to make working with the application easier.
Software Commands
Commands are written in the fonts shown here:
^AR Merge Scene,,Op1 scene 1,1 ^B 51 ^W^C
[01] R 0004 00300 00400 00800 00600 [02] 35 [17] [03]
E X! *X1&* X2)* X2#* X2! CE}
NOTE: For commands and examples of computer or device responses mentioned
in this guide, the character “0” is used for the number zero and “O” is the capital
letter “o.”
Computer responses and directory paths that do not have variables are written in the font
shown here:
Reply from 208.132.180.48: bytes=32 times=2ms TTL=32
C:\Program Files\Extron
Variables are written in slanted form as shown here:
ping xxx.xxx.xxx.xxx —t
SOH R Data STX Command ETB ETX
Selectable items, such as menu names, menu options, buttons, tabs, and field names are
written in the font shown here:
From the File menu, select New.
Click the OK button.
Specifications Availability
Product specifications are available on the Extron website, www.extron.com.
vExtron DTP T HD2 4K 230/330 • Contents
Contents
Introduction............................................................ 1
About the DTP T HD2 4K 230/330 ..................... 1
Features ............................................................. 1
Application Diagram ........................................... 2
Installation and Features .................................... 3
Mounting the Units ............................................. 3
Tabletop Use .................................................. 3
Mounting Kits ................................................. 3
UL Rack-Mounting Guidelines ........................ 4
Front Panel Features ........................................... 4
Rear Panel Features ........................................... 5
Twisted Pair Recommendations for DTP
Communication ................................................. 7
Supported Cables .......................................... 7
Cable Recommendations ............................... 7
Power Supply Wiring .......................................... 8
SIS Commands ................................................... 10
Introduction to SIS ........................................... 10
Host-to-Transmitter
Communications ......................................... 10
Transmitter-initiated Messages ...................... 10
Copyright Information ................................... 10
Symbols Used in this Guide .............................. 11
Symbol Definitions ........................................ 11
Error Messages ............................................ 13
EDID ............................................................. 13
TMDS Output Format ................................... 13
DTP T HD2 4K EDID Memory Locations ........... 14
Command and Response Table for SIS
Commands ..................................................... 15
Extron DTP T HD2 4K 230/330 • Introduction 1
Introduction
This guide describes the function, installation, and operation of the DTP T HD2 4K series of
HDMI extenders. Unless otherwise stated, the terms “extender” and “transmitter” are used
interchangeably in this guide to refer to all of the products in the series.
This section provides the following information:
z About the DTP T HD2 4K 230/330
z Features
z Application Diagram
About the DTP T HD2 4K 230/330
The DTP T HD2 4K family extends HDMIsignals up to 230 feet (70 meters) for the 230
model, and 330 feet (100 meters) for the 330 model over shielded twisted pair (STP) cables.
Both models are fully High-bandwidth Digital Content Protection (HDCP) compliant.
These extenders support data rates up to 10.2 Gbps (3.4 Gbps per color) with up to 12-bit
deep color and use the EDID Minder feature for EDID management.
The automatic output compatibility correction feature scans each output device to ensure
that the output signal is compatible with the color depth and format requirements of the
device. Each output is adjusted independently.
Features
Extends HDMI plus control and analog audio up to 230 feet (70 meters) or
330 feet (100 meters) over STP cable (depending on model) — The DTP T HD2 4K
series provides high reliability and maximum performance on an economical and easily
installed cable infrastructure.
Inputs: One HDMI with buffered input loop-through
Output: One DTP 230 or DTP 330 (depending on model) twisted pair output on
RJ-45
Supports computer and video resolutions up to 4K, including 1080p/60 Deep Color
Buffered HDMI input loop-through — The DTP T HD2 4K series features an active local
HDMI output for local monitor support or system expansion.
Remote power capability — For simplified installation, the transmitter can be
remotely powered by a DTP 230/330-enabled product over the twisted pair
connection.
HDCP compliant — Fully supports HDCP-encrypted sources, with selectable authorization
for unencrypted content.
EDID Minder automatically manages EDID communication between connected
devices — EDID Minder ensures that the source powers up properly and reliably outputs
content for display.
Supports EDID and HDCP transmission — DDC channels are actively buffered, allowing
continuous communication between source and display.
Extron DTP T HD2 4K 230/330 • Introduction 2
HDCP authentication and signal presence confirmation — Provides real-time
verification of HDCP status for each digital video input and output. This allows for simple,
quick, and easy signal and HDCP verification through front panel LEDs or USB, providing
valuable feedback to a system operator or helpdesk support staff.
Front panel USB configuration port — Enables easy configuration without having to
access the rear panel.
LED indicators for signal presence, HDCP, and power — Provides visual indication of
system status for real-time feedback and monitoring of key performance parameters.
Application Diagram
The diagram below shows a typical application for the DTP T HD2 4K.
50-60 Hz
100-240V ~
2.0 A MAX
1
L
R
SIG LINK
OUT
SIG LINK
OUT
1
3
4
4
XTP
RS-232 IR
Tx Rx
RTSCTS
GTxRxG Tx Rx G
RS-232 IR
Tx Rx Tx RxG
Tx Rx G
Tx Rx Tx Rx
XTP
RESET
S/PDIF
OUT
DTP
XTP
DTP
XTP
DTP
EXP
+48V
MIC/LINE
1
1
3
2
4
2
3
4
LINK
LAN 2
LAN 1
LAN 3
HDBT
G
DTP
HDBT
2
1234
5
7
8
6
DTP CROSSPOINT 84
4
CLASS 2 WIRING
8/
R
RS-232 IR
Tx Rx Tx RxG
OVER TP
OVER TP
REMOTE
SIG LINK
IN
SIG LINK
IN
AUDIO INPUTS
AUDIO OUTPUTS
AMP OUTPUT
CONTROL
1234G
DIGITAL I/OCOM 3COM 2COM 1
S
DMP EXPANSION
SGG
1
1
2
2
C34C
INPUTS
-S G+S+V
PWR OUT = 6W
OUTPUTS
RS-232 IR
Tx Rx Tx RxG
1
LR
1
LR
3
LR
3
LR
5
LR
2
LR
4
LR
2
LR
4
LR
6
LR
IR/SERIAL eBUSRELAYS
OVER TP
RS-232
IR
TxRx Tx RxG
POWER
12V
0.8A MAX
SIG LINK
IN
OUTPUTS
LR
AUDIO
POWER
12V
--A MAX
RS-232 IR
RxTx RxTxG
OVER DTP
INPUT
LOOP THRU
DTP
HDBT
SIG
OUT
LINK
OUTPUTS
AUDIO
TxRx GTxRx
RS-232 IR
OVER DTP
OUTPUTS
AUDIO
TxRx GTxRx
RS-232 IR
OVER DTP
Monday, December 16, 2013 7:04 AM
Menu DeleteKey
2
ABC
3
DEF
6
MNO
5
JKL
4
GHI
9
WXYZ
8
TUV
0
7
PQRS
1
800.633.9876
End
Call
Call
Enter
Full
Screen
CameraDisplay Presets
Privacy
Near
End
Zoom
In
Zoom
Out
Far
End
Contacts
Name +-
Sources
Andrew
Video Window
Beth
Charlie
David
Ervin
Frank
Greg
Harold
Kevin
Mike
Andrew
(800) 633 - 9876
1 2 3
Extron Extron
WiFi
1234
Display
CATx Cable
up to 330'
(100 m)
CATx Cable up to 230' (70 m)
CATx Cable up to 330' (100 m)
RS-232HDMI
RS-232 DisplayPort
Extron
DTP HDMI
4K 230 D Rx
Receiver
AudioAudio
Inputs
Outputs
Microphones
Extron
SM 26
Surface Mount
Speakers
Extron
DTP CrossPoint 84 IPCP SA
Scaling Presentation Matrix
Ethernet
Wireless
Relay
Ethernet
Extron
TLP Pro 1220
TG
12" Ta bletop
TouchLink Pro
Touchpanel
Extron Control App
TCP/IP
Network
Extron
DTP R DP
4K 330
Receiver
Projector
Screen Control
Ethernet/PoE
Power
Injector
Extron
DTP T HD2
4K 330 D
Transmitter
Local Monitor
PC
HDMI
HDMI
Figure 1. DTP T HD2 4K Application Diagram
Extron DTP T HD2 4K 230/330 • Installation and Operation 3
Installation and
Features
This section of the guide describes the following topics concerned with the installation,
setup, and operation of the DTP T HD2 4K series of extenders.
z Mounting the Units
z Front Panel Features
z Rear Panel Features
z Power Supply Wiring
z Twisted Pair Recommendations for DTP Communication
Mounting the Units
ATTENTION:
Installation and service must be performed by authorized personnel only.
L’installation et l’entretien doivent être effectués par le personnel autorisé
uniquement.
The DTP T HD2 4K series of extenders can be placed on a table, mounted in a rack, or
mounted under a desk or table.
Tabletop Use
Affix the included rubber feet to the bottom of the unit and place it in any convenient
location.
Mounting Kits
Mount the unit using any optional compatible mounting kit listed on the Extron website
(www.extron.com), in accordance with the directions included with the kit. For rack
mounting, see UL Rack-Mounting Guidelines on the next page.
Extron DTP T HD2 4K 230/330 • Installation and Operation 4
UL Rack-Mounting Guidelines
The following Underwriters Laboratories (UL) requirements pertain to the installation of the
unit into a rack.
Elevated operating ambient temperature — If installed in a closed or multi-unit rack
assembly, the operating ambient temperature of the rack environment may be greater
than room ambient. Therefore, consider installing the equipment in an environment
compatible with the maximum ambient temperature (TMA = +122 °F, +50 °C) specified
by Extron.
Reduced air flow — Installation of the equipment in a rack should be such that the
amount of air flow required for safe operation of the equipment is not compromised.
Mechanical loading — Mounting of the equipment in the rack should be such that a
hazardous condition is not achieved due to uneven mechanical loading.
Circuit overloading — Consideration should be given to the connection of the
equipment to the supply circuit and the effect that overloading of the circuits might have
on overcurrent protection and supply wiring. Appropriate consideration of equipment
nameplate ratings should be used when addressing this concern.
Reliable Earthing — Reliable earthing of rack-mounted equipment should be
maintained. Particular attention should be given to supply a connection other than a
direct connection to a branch circuit, such as by using a power strip.
Front Panel Features
Extron
SIGNAL
HDCP
INPUT
2
OUTPUTS
LOOP
THRU
DTP T HD2 4K 330
CONFIG
A B C
D
A
Power status LED — Lights green when power is applied to the unit.
B
USB Config port — Used for firmware updates, SIS configuration, and software
control.
C
Input/Output signal LEDs — Light green when HDCP presence is detected on the
HDMI input.
D
Input/Output HDCP LEDs — Light green when HDCP presence is detected on the
HDMI outputs.
Extron DTP T HD2 4K 230/330 • Installation and Operation 5
Rear Panel Features
POWER
12V
1.0A MAX
RS-232 IR
RxTx RxTxG
OVER TP
INPUT
LOOP THRU
DTP
HDBT
SIG
OUT
LINK
A
B C
D E F
A
DC power input connector — Wire and plug the included external 12 VDC power
supply into either this 2-pole connector or the power input connector on the receiver
(see page 8 for wiring information).
B
HDMI input — Connect a source device to this female HDMI type A connector.
C
HDMI Loop Thru — Connect a display to this female HDMI type A connector for local
loop-through monitoring of the source signal.
D
DTP/HDBaseT configuration switch — Set this 2-position, recessed switch to
configure the output between DTP and HDBaseT modes. When configured for DTP, use
a DTP-compatible receiver. When configured for HDBaseT, use an HDBaseT-compatible
receiver.
NOTES:
When the switch is set to DTP mode, only one power supply is required. A
single power supply connected to either a transmitter or compatible receiver
can power both units.
When the switch is set to HDBaseT mode, remote power is disabled and
power supplies are required for both transmitter and receiver. Analog audio is
enabled, but incompatible with third-party HDBaseT devices.
E
DTP/HDBaseT output — Use an STP cable to connect this output to the input of a
compatible receiver (see Twisted Pair Recommendations for DTP Communication
on page 7 for more information).
ATTENTION:
Do not connect these outputs to a telecommunications or computer data
network.
Ne connectez pas ces appareils à des données informatiques ou à un réseau
de télécommunications.
A
DC power input connector
D
DTP/HDBaseT configuration switch
B
HDMI input
E
DTP/HDBaseT output
C
HDMI Loop Thru
F
Over DTP RS-232/IR connector
Extron DTP T HD2 4K 230/330 • Installation and Operation 6
F
RS-232 Over TP port — To pass bidirectional serial control between
DTP-compatible or HDBaseT-compatible devices, connect a control device
to the 5-pole captive screw connector. This port includes only the 3 poles
labeled “RS-232” (see image below for wiring instructions).
IR Over TP port — To transmit and receive IR signals, connect a control
device to the 5-pole captive screw connector. This port includes only the
2 poles labeled “IR” and shares the ground pole with the RS-232 port
(see image below for wiring instructions).
Tx/Rx
Pins
Rx GTx
RS-232 IR
RxTx
TxRx
RxTx
Gnd
Gnd
IR Device
RS-232 Device
NOTE: RS-232 and IR data can be transmitted simultaneously.
IR
Tx Rx G Tx Rx
RS-232
IR
Tx Rx G Tx Rx
RS-232
Extron DTP T HD2 4K 230/330 • Installation and Operation 7
Twisted Pair Recommendations for DTP Communication
Use the following pin configurations for shielded twisted pair cables.
5
Pin
1
2
3
6
7
8
4
Wire color
White-green
Green
White-orange
White-blue
Orange
White-brown
Brown
Blue
TIA/EIA T
568 B
TP Wires
12345678
Pins:
Supported Cables
The transmitters are compatible with shielded twisted pair cable (F/UTP, SF/UTP, and
S/FTP).
ATTENTION:
Do not use Extron UTP23SF-4 Enhanced Skew-Free AV UTP cable or STP201
cable to link the device with DTP transmitters or receivers.
N’utilisez pas le câble AV Skew-FreeUTP version améliorée UTP23SF d’Extron
ou le câble STP201 pour relier le appareil avec les émetteurs ou les récepteurs
DTP.
Cable Recommendations
Extron recommends using the following practices to achieve full transmission distances and
reduce transmission errors.
Use the following Extron XTP DTP 24 SF/UTP cables and connectors for the best
performance:
XTP DTP 24/1000 Non-Plenum 1000’ (305 m) spool 22-236-03
XTP DTP 24P/1000 Plenum 1000’ (305 m) spool 22-235-03
XTP DTP 24 Plug Package of 10 101-005-02
If not using XTP DTP 24 cable, at a minimum, Extron recommends 24 AWG, solid
conductor, STP cable with a minimum bandwidth of 400 MHz.
Terminate cables with shielded connectors to the TIA/EIA-T568B standard.
Limit the use of more than two pass-through points, which may include patch points,
punch down connectors, couplers, and power injectors. If these pass-through points
are required, use shielded couplers and punch down connectors.
NOTE: When using shielded twisted pair cable in bundles or conduits, consider the
following:
Do not exceed 40% fill capacity in conduits.
Do not comb the cable for the first 20 meters, where cables are straightened,
aligned, and secured in tight bundles.
Loosely place cables and limit the use of tie wraps or hook-and-loop fasteners.
Separate twisted pair cables from AC power cables.
Extron DTP T HD2 4K 230/330 • Installation and Operation 8
Power Supply Wiring
NOTES:
Only one power supply is required. A single power supply connected to either a
transmitter or compatible receiver can power both units.
Remote power is only available when the unit is set to DTP mode. When the unit is
set to HDBaseT mode, remote power and analog audio are disabled.
A power supply is included with each individually-packaged transmitter.
Do not tin the power supply leads before installing them in the direct insertion
connector. Tinned wires are not as secure in the connectors and could be pulled
out.
Figure 2 shows how to wire the connector.
SECTION A–A
AA
Power Supply
Captive Screw
Ridges
Smooth
3/16"
(5 mm) Max.
Connector
Output Cord
Figure 2. Power Connector Wiring
CAUTION: The wires must be kept separate while the power supply is plugged in.
Remove power before wiring.
ATTENTION : Les deux cordons d’alimentation doivent être tenus à l’écart l’un de
l’autre quand l’alimentation est branchée. Couper l’alimentation avant de faire
l’installation électrique.
Extron DTP T HD2 4K 230/330 • SIS Commands 10
SIS Commands
This section provides information about the SIS commands that are used to configure the
DTP T HD24K series. The following topics are discussed:
z Introduction to SIS
z Symbols Used in this Guide
z DTP T HD2 4K EDID Memory Locations
z Command and Response Table for SIS Commands
Introduction to SIS
The transmitter can be set up and controlled remotely via Extron SIS commands that are
issued from a host computer running the Extron DataViewer utility or other control system.
The host device can be connected to the mini USB config port on the front panel.
NOTE: The wiring in the RS-232 cables crosses over so that the unit transmit (Tx) wire
connects with the control device receive (Rx) and vice versa.
Host-to-Transmitter Communications
SIS commands consist of strings (one or more characters per command field). No special
characters are required to begin or end a command sequence. Unless otherwise stated,
upper and lower case characters can be used interchangeably. Most responses from the
transmitter end with a carriage return and a line feed (CR/LF = ]), which signals the end
of the response character string. When the device determines that a command is valid, it
executes the command and sends a response to the host device.
Transmitter-initiated Messages
When a local event such as a change in signal status takes place, the transmitter responds
by sending a message to the host, indicating the status change. No response is required
from the host.
Copyright Information
The copyright message is displayed upon connecting to a transmitter USB.
] © Copyright 20yy, Extron Electronics, DTP T HD2 4K 230/330,
Vx.xx,60-xxxx-01]
20yy is the year the currently installed firmware was released, Vx.xx is the firmware
version number, and 60-xxxx-01 is the catalog part number.
Extron DTP T HD2 4K 230/330 • SIS Commands 11
Symbols Used in this Guide
When programming in the field, certain characters are most conveniently represented by
their hexadecimal rather than their ASCII values. The table below shows the hexadecimal
equivalent of each ASCII character:
ASCII to HEX Conversion Table
Space
.
Table 1. ASCII to HEX Conversion Table
Symbol Definitions
= Space
]
= Carriage return with line feed
| or }
= Carriage return with no line feed
E or
W
= Escape
X!
= Output selection
1 through maximum number of outputs
X@
= Output status
0 = disabled/off/undetected
1 = enabled/on/detected
X#
= Video color bit depth
0 = auto (based on EDID of sink)
1 = force 8-bit
X$
= EDID memory location 1-16 (default is 9)
See the DTP T HD2 4K EDID Memory
Locations table on page 14.
X%
= EDID data as 256 bytes of hex
data (text representation)
X^
= Native resolution and refresh rate
(translated from hex)
Example: 1600x1200 @60Hz
X&
= Controller firmware version to the
second decimal place
X*
= Unit name: Up to 24
alphanumeric characters
(including hyphen [-])
No spaces allowed
No distinction between upper and lower case
letters
First character must be a letter
Last character cannot be a hyphen (-)
Default is model name
X(
= Video mute
0 = video mute disabled
1 = video mute (TMDS)
2 = video and sync mute
Extron DTP T HD2 4K 230/330 • SIS Commands 12
X1)
= TMDS output format
0 = Auto (default), pass through if HDMI sink,
force DVI format if DVI sink
1 = DVI RGB 444
2 = HDMI RGB “Full”
3 = HDMI RGB “Limited”
4 = HDMI YUV 444 “Full”
5 = HDMI YUV 444 “Limited”
6 = HDMI YUV 422 “Full”
7 = HDMI YUV 422 “Limited”
X1!
= HDCP output mode
0 = Encrypt as required by input
(Continuous trials for HDMI sinks, attempt for
10 seconds on DVI sinks,then fail)
1 = Always encrypt
(Continuous trials for HDMI sinks, attempt for
10 seconds on DVI sinks,then fail)
2 = Encrypt as required by input
(Continuous trials for HDMI sinks and DVI sinks)
3 = Always encrypt
(Continuous trials for HDMI sinks and DVI sinks)
X1@
= DTP/HDBaseT switch position
0 = DTP mode
1 = HDBaseT mode
X1#
= Verbose mode
0 = Clear/none (default for telnet)
1 = Verbose mode (default for USB)
2 = Tagged responses for queries
3 = Verbose mode and tagged responses for
queries
Extron DTP T HD2 4K 230/330 • SIS Commands 13
Error Messages
E01 — Invalid output channel number (too large)
E10 — Invalid command
E13 — Invalid value (too large)
EDID
User assigned mode
In user assigned mode, the user can select from 14 factory loaded EDID files, each
categorized by rate type (IT or CE), video format (DVI or HDMI), audio type (2-Ch), and
native resolution. The unit retains this setting after a power cycle.
Additionally, two user-loaded slots are available to save the EDID of any connected display.
EDID saved to these slots are retained after a power cycle. Upon a factory reset, these EDID
revert to the factory default (720p @ 60 Hz, 2-Ch audio).
A table showing the factory loaded EDID options is shown on the following page. The EDID
memory location is labelled
X$
for consistency with the value in the SIS commands.
TMDS Output Format
The TMDS output format has three components:
Video format (HDMI or DVI)
Colorspace (RGB 4:4:4, YUV 4:2:2, or YUV 4:4:4)
Quantization range (full [0-255] or limited [16-235]).
By default, the output format will be configured for AUTO, which will automatically force
RGB 4:4:4 Full, with the video format being dependent on the source signal and the sink
capabilities.
NOTE: When the source signal is detected as 4K/UHD @ 60Hz with YUV 4:2:0 (based
on AVI infoframe data), it must pass unaltered, overriding the TMDS output format
setting. If the TMDS output format is changed while this signal type is passing, the
setting will be applied, but with no observable change. The TMDS output format will
resume as configured when the source signal changes to a signal other than 4K/UHD
@ 60 Hz with YUV 4:2:0.
Extron DTP T HD2 4K 230/330 • SIS Commands 14
DTP T HD2 4K EDID Memory Locations
X$
Native Resolution Refresh Rate Rate Type Video Format Audio Type
1 1280x800 60 Hz IT HDMI 2-Ch
2 1440x900 60 Hz IT HDMI 2-Ch
3 1600x900 60 Hz IT HDMI 2-Ch
4 1680x1050 60 Hz IT HDMI 2-Ch
5 1920x1200 60 Hz IT HDMI 2-Ch
6 2560x1440 60 Hz IT HDMI 2-Ch
7 2560x1600 60 Hz IT HDMI 2-Ch
8 720p 50 Hz CE HDMI 2-Ch
9* 720p 60 Hz CE HDMI 2-Ch
10 1080p 50 Hz CE HDMI 2-Ch
11 1080p 60 Hz CE HDMI 2-Ch
12 4K / UHD 30 Hz CE HDMI 2-Ch
13 Output 1
14 Output 2
15 User Loaded Slot 1
16 User Loaded Slot 2
*Default
Extron DTP T HD2 4K 230/330 • SIS Commands 15
Command and Response Table for SIS Commands
Command ASCII Command
(host to unit)
Response
(unit to host)
Additional Description
Video Mute
Video mute single output
X!*X(B/b VmtX!*X(] X( = 0-2 (default is 0)
Video mute all outputs
X(B/b VmtX(]
Query video mute status
B/b X(X(]
VmtX(X(]
Video mute status of outputs 1-2
Verbose Mode 2/3
Embedded Audio Mute
Audio mute single output
X!*X@Z/z AmtX!*X@]
Audio mute of embedded audio only
Audio mute all outputs
X@Z/z AmtX@]
Query audio mute status
Z/z X@X@]
AmtX@X@]
Audio mute status of outputs 1-2
Verbose Mode 2/3
TMDS Output Format
Set format for single
output
EX!*X1)VTPO} VtpoX!*X1)] X1) = 0-7 (default is 0)
Set format for all outputs
EX1)VTPO} VtpoX1)]
Query format settings
EVTPO} X1)X1)]
VtpoX1)X1)]
Outputs 1-2
Verbose Mode 2/3
Video Color Bit Depth
Set video bit depth for a
single output
EVX!*X#BITD} BitdVX!*X#] X# = 0 (default) or 1
Set video bit depth for all
outputs
EVX#BITD} BitdVX#] X# = 0 (default) or 1
Query video bit depth for
all outputs
EVBITD} X#X#]
BitdVX#X#]
Video bit depth of outputs 1-2
Verbose Mode 2/3
NOTES:
X! = Output selection
X@ = Output status
X# = Video color bit depth
X( = Video mute
X1) = TMDS output format
1
through max number of outputs
0
(disabled/off/undetected, default)
, 1
(enabled/on/detected)
0 = auto (based on EDID of sink), 1 = force 8-bit
0 = disabled, 1 = video (TMDS), 2 = video and sync
0 = Auto (default)
1 = DVI RGB 444
2 = HDMI RGB “Full”
3 = HDMI RGB “Limited”
4 = HDMI YUV 444 “Full”
5 = HDMI YUV 444 “Limited”
6 = HDMI YUV 422 “Full”
7 = HDMI YUV 422 “Limited”
Extron DTP T HD2 4K 230/330 • SIS Commands 16
Command ASCII Command
(host to unit)
Response
(unit to host)
Additional Description
HDCP Output Mode
Set HDCP output mode
for a single output
ESX!*X1!HDCP} HdcpSX!*X1!] X1! = 0-3 (0 is default)
Set HDCP output mode
for all outputs
ESX1!HDCP} HdcpSX1!] X1! = 0-3 (0 is default)
Query HDCP output mode
for all outputs
ESHDCP} X1!X1!]
HdcpSX1!X1!]
Video bit depth of outputs 1-2
Verbose Mode 2/3
Signal Status (unsolicited)
Request all signal status
ELS} X@*X@X@]
SigX@*X@X@]
Input * Outputs 1-2
Verbose Mode 2/3
Request all HDCP status
EHDCP} X@*X@X@]
HdcpX@*X@X@]
Input * Outputs 1-2
Verbose Mode 2/3
HDCP Authorized Device
HDCP authorization
enable/disable
EEX@HDCP} HdcpEX@] X@ = 0 (disabled), 1 (enabled, default)
Query HDCP authorization
status
EEHDCP}
X@]
HdcpX@]
X@ = 0 (disabled), 1 (enabled, default)
Verbose Mode 2/3
NOTES:
X! = Output selection
X@ = Output status
X1! = HDCP output mode
1
through max number of outputs
0
=
disabled/off/undetected (default)
, 1
=
(enabled/on/detected)
0 = Encrypt as required by input
(Continuous trials for HDMI sinks, attempt for 10 seconds on DVI
sinks, then fail)
1 = Always encrypt
(Continuous trials for HDMI sinks, attempt for 10 seconds on DVI
sinks, then fail)
2 = Encrypt as required by input
(Continuous trials for HDMI sinks and DVI sinks)
3 = Always encrypt
(Continuous trials for HDMI sinks and DVI sinks)
Extron DTP T HD2 4K 230/330 • SIS Commands 17
Command ASCII Command
(host to unit)
Response
(unit to host)
Additional Description
EDID Minder
Assign EDID to input
EAX$EDID} EdidAX$] X$ = EDID memory location (1-16)
see the DTP T HD2 4K EDID
Memory Locations table on page 14
(default is 9)
View EDID assignment
EAEDID}
X$]
EdidAX$]
Verbose Mode 2/3
Save EDID of output to
user location
ESX!*X$EDID} EdidSX!*X$]
Store the EDID of output X! into EDID
memory location X$ (58 or 59)
View/Read EDID in Hex
EREDID}
X%]
EdidRX%
Display currently assigned EDID in
Hex
Verbose 2/3
View EDID native
resolution
ENEDID}
X^]
EdidNX^
Resolution and refresh rate of
currently selected EDID
Verbose Mode 2/3
Example: 1600x1200@60Hz
Unit Name
Set unit name
EX*CN} IpnX*]
X* = Up to 24 alphanumeric
characters, including "-"
Set unit name to factory
default
ECN} Ipn{Default}]
Example:
DTP-T-HD2-330
(Model name)
View unit name
ECN}
X*]
IpnX*]
Verbose Mode 2/3
Other
Set verbose mode
EX1#CV} VrbX1#] 0-3 (1 is default)
Query verbose mode
ECV}
X1#]
VrbX1#]
Verbose Mode 2/3
Query DTP mode
EO1HDBT} X1@]
HdbtOX1@]
Verbose Mode 2/3
Request part number
N/n 60-1491-12]
60-1491-52]
DTP T HD2 4K 230
DTP T HD2 4K 330
Query firmware version
Q/q
X&]
Query firmware version
with build
*Q/q x.xx.xxxx]
Firmware build with 2 decimals
Reset settings
EZXXX} Zpx]
NOTES:
X! = Output selection
X$ = EDID memory location
X% = EDID data as 256 bytes of hex data (text representation)
X^ = Native resolution and refresh rate (translated from hex)
X* = Unit name
X1@ = DTP/HDBaseT switch position
X1# = Verbose mode
1
through max number of outputs
1-16
(9 is default), see table on page 14
Example: 1600x1200@60Hz
Up to 24 alphanumeric characters (including hyphen [-])
0 = DTP mode, 1 = HDBaseT mode
0 = Clear/none (default for telnet)
1 = Verbose mode (default for RS-232 and USB)
2 = Tagged responses for queries
3 = Verbose mode and tagged responses for queries
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23

Extron DTP T HD2 4K 330 User manual

Type
User manual
This manual is also suitable for

Extron DTP T HD2 4K 330 is a high-performance transmitter for sending HDMI signals up to 4K/60 at 4:4:4 over twisted pair cable. It supports long distance transmission up to 330 feet (100 meters) at 4K/60 and 460 feet (140 meters) at 1080p, and features EDID Minder, Key Minder, and HDCP. With its compact enclosure, the DTP T HD2 4K 330 can be surface mounted or used in an optional rack-mount kit.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI