Hagerco 2909 - 2A Modular Access Control Power Supply Installation guide

Type
Installation guide
2-679-0703 Electric Latch Retraction Sequencer
Installation Instructions
I-EA00140
Rev -, Rev Date: 01/09/15
Always visit www.hagerco.com for the latest Installation Instructions
HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 (800) 325-9995
The electric latch retraction sequencer module may be used with any Hager latch retraction system such as the
Hager 4501 ELR or the 4501 MLR, any Hager electric strike, or any Hager maglock to provide a delayed signal to
operate an automatic door operator or when powering a pair of exit devices from a Hager 2909 power supply.
The two sequencer channels may be operated as two independent doors or in tandem mode for pairs of doors.
Each sequencer channel provides dry output for powering the exit device and a “delayed” dry auxiliary output
for activation of an automatic door operator. All outputs are field selectable as Normally Open or Normally
Closed.
When the Electric Latch Retraction Sequencer is used in the tandem mode, power supply requirements for a
pair of doors are minimized. Since the attached electric latch retraction devices are powered in a sequential
manner, the inrush current of each device is staggered. This creates a lower current requirement upon
activation. A smaller power supply can now be used to operate the pair of devices .
SEQUENCER OPERATION:
ELECTRICAL SPECIFICATIONS
Input Voltage: 12VDC or 24VDC (+/- 10%)
Input Current: 140mA max
Exit & Operator Contacts: N/C or N/O, field selectable
10 AMP @ 30VDC (Resistive)
Access Control Inputs: N/O Dry Contact
Electric Latch Retraction Sequencer
DOOR OPERATOR
OUTPUTS (OPR)
Isolated relay contacts provide a delayed signal
to activate the automatic door operator.
DIP
SWITCHES
SW1 Select Single or Tandem Door activation.
SW2 Select time period to delay operator activation
ACCESS
CONTROL
INPUTS
A momentary closure will activate the ELR device.
The device will release after the input is removed and
the relock activation period has expired.
STATUS
LED’S
Provides a visual indication of the device latch
status and relock timer status
ELR RELAY
ACTIVATION
PERIOD
Adjust to control the length of time that the BAR
output relay activates.
EXIT DEVICE
OUTPUTS (BAR)
Goes inline with the locking device power or
connects to the power booster for Hager ELR
exit devices.
T1
T2
1 2
J1
J2
J3 J4
POWER
BAR 1 OPR 1 BAR 2 OPR 2
AC 1
AC 2
-
+
1 2 3 4 5 6 7 8 C NO C NO
1
2
3
4
Channel 1
Channel 2
Page 1 of 3
2-679-0703 Electric Latch Retraction Sequencer
Installation Instructions
I-EA00140
Rev -, Rev Date: 01/09/15
Always visit www.hagerco.com for the latest Installation Instructions
HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 (800) 325-9995
ADJUSTABLE
RELOCK TIMER
T1 = BAR 1; T2 = BAR 2
(10 to 35 seconds; Added to
Access Control Input time)
DOOR
OPERATOR
#1
MLR DEVICE
#1
MLR DEVICE
#2
Operator
Power
Operator
Power
ELECTRIC LATCH RETRACTION SEQUENCER MLR TYPICAL WIRING
T1
T2
1 2
J1
J2
J3 J4
POWER
OPR 1 OPR 2
AC 1
AC 2
-
+
1 2 3 4 6 7 8 C NO C NO
1
2
3
4
SECURITY
DOOR
CONTROLS
N/C
N/O
Jumper Relay Terminals
J1 BAR 1 1 & 2
J2 OPR 1 3 & 4
J3 BAR 2 5 & 6
J4 OPR 2 7 & 8
RELAY CONFIGURATION JUMPERS
BAR 1
5
BAR 2
DOOR
OPERATOR #2
1
2
3
4
SINGLE TANDEM
3 SEC 6 SEC
}
Not Used
2909
x
2-679-0703
Power Supply
Automatic
Operator
Power
Transfer
Hinge
Access
Control
4501/4601 MLR
SINGLE DOOR
Power Supply
2909
x
2-679-0703
Power
Transfer
Hinge
Automatic Operators
Power
Transfer
Hinge
Access
Control
4501/4601 MLR 4501/4601 MLR
PAIR OF DOORS (TANDEM)
C
N/C
N/O
C
N/C
N/O
Access
Control
Input
#2
Access
Control
Input
#1
*
*
In Tandem Mode, use only
Access Control Input #1
Power
Transfer
Power
Transfer
24V
12V
CHG FLOAT
AC VOLTAGE
INPUT
VOLTAGE SELECT
SWITCHES
+
-
C
+
-
Hager
2909
Page 2 of 3
2-679-0703 Electric Latch Retraction Sequencer
Installation Instructions
I-EA00140
Rev -, Rev Date: 01/09/15
Always visit www.hagerco.com for the latest Installation Instructions
HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 (800) 325-9995
ADJUSTABLE
RELOCK TIMER
T1 = BAR 1; T2 = BAR 2
(10 to 35 seconds; Added to
Access Control Input time)
DOOR
OPERATOR
#1
ELR DEVICE
#1
ELR DEVICE
#2
Operator
Power
Operator
Power
ELECTRIC LATCH RETRACTION SEQUENCER ELR TYPICAL WIRING
T1
T2
1 2
J1
J2
J3 J4
POWER
OPR 1 OPR 2
AC 1
AC 2
-
+
1 2 3 4 6 7 8 C NO C NO
1
2
3
4
SECURITY
DOOR
CONTROLS
N/C
N/O
Jumper Relay Terminals
J1 BAR 1 1 & 2
J2 OPR 1 3 & 4
J3 BAR 2 5 & 6
J4 OPR 2 7 & 8
RELAY CONFIGURATION JUMPERS
BAR 1
5
BAR 2
DOOR
OPERATOR
#2
1
2
3
4
SINGLE TANDEM
3 SEC 6 SEC
}
Not Used
C
N/C
N/O
C
N/C
N/O
Access
Control
Input
#2
Access
Control
Input
#1
*
*
In Tandem Mode, use only
Access Control Input #1
Power
Transfer
Power
Transfer
24V
12V
CHG FLOAT
AC VOLTAGE
INPUT
VOLTAGE SELECT
SWITCHES
+
-
C
+
-
Hager
2909
RELAY
Power Booster
1
2
6
5
4
3
2 1
-
+
-
+
-
+
RELAY
Power Booster
1
2
6
5
4
3
2 1
-
+
-
+
-
+
Page 3 of 3
  • Page 1 1
  • Page 2 2
  • Page 3 3

Hagerco 2909 - 2A Modular Access Control Power Supply Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI