Savant STP-NEON10MOD-00 Deployment Guide

Type
Deployment Guide

This manual is also suitable for

Savant Neon Light Strip Installation Guide | 009-1765-01
Copyright © 2019 Savant Systems, LLC
45 Perseverance Way, Hyannis, MA 02601
Savant.com | 508.683.2500
- 1 -
Savant Neon Light Strips - Installation Guide
[STP-NEON10MOD-00 - STP-NEONXX-XX]
Document Number: 009-1765-01
Document Date: January 2019
Document Supports: Savant Neon Light Strips - [STP-NEONXX-XX]
This document provides step by step instructions for installation of Savant Neon Light Strips. This guide is specic to neon strips, and
should be used as a supplementary document to the Wired DMX and 0 to 10V Lighting Deployment Guide, which provides a detailed
overview of installation and programming for all Savant DMX and 0 to 10 volt lighting products, including Neon and RGBW light strips,
and can be found on the Savant.com Store pages for related products, or on the Knowledge Base via the Savant Customer Community
Portal.
Details of this guide include:
Savant Neon Light Strip (STP-NEON10MOD-00) specications and product features,
Recommended installation guidelines, precautions, and safety information,
How to cut strip to desired length,
How to install power connection to transmission end of strip,
How to install tail plug to cap non-transmission end of strip.
2 of 5
Savant Neon Light Strip Installation Guide
009-1765-01 | 190109
Copyright © 2019 Savant Systems, LLC
1. Product Safety Requirements
All installation instructions and precautions detailed in this document must be read and understood prior to installation.
Failure to properly follow installation guidelines may result in fracture of neon ex coating, water penetration, sudden loss of power, or other
undesirable behavior.
Product must be used only with the supplied power connector. Input voltage must adhere strictly to product design specications to ensure normal
functionality and product safety.
Installation and maintenance of this product must be performed by an electrician or comparably experienced professional installer.
Product must not be powered on before installation is complete.
Once installation is complete, all connections should be checked for accuracy, ensuring there are no short circuits before product is powered on.
During installation, any hard bends or creases in the product should be positioned so as not to apply stress to LEDs or other non-exible components
which could aect the integrity of the product or its waterproong, particularly when installing outdoors. Minimum bend diameter 120 mm.
Product should be installed out of reach of unsupervised children.
Product must be powered o during cleaning or other maintenance.
2. Product Description and Features
Savant Neon Light Strips are a type of exible, LED strip lighting which feature improved energy savings, greater ease of installation and maintenance,
reduced environmental impact, and longer service life when compared to traditional lighting products.
Savant’s modern take on Neon is a great product for any artistic or direct accent lighting application. This product has a super diuse coating, which
provides a look that is similar to traditional neon, yet has all the exibility of an RGB controllable LED strip. The primary distinction between this product
and standard Savant LED strip lighting is that it is designed to be viewed directly (bar/shelf/architecture accents), whereas standard LED strips are designed
to provide indirect lighting (under cabinet, cove lighting).
Strips can be cut to t within a desired length, (see instructions below; proper cutting procedure must be followed!)
Strips can bend and ex to be installed in a variety of shapes and patterns.
Strips meet specications for IP67 water resistance, and can be installed in both indoor and outdoor environments.
Cross section of Savant Neon Light Strip.
Note 4 wires -
(Red, Green, Blue, and Ground).
Cut strips ONLY along marked sections
(in 1 meter increments)
3 of 5
Savant Neon Light Strip Installation Guide
009-1765-01 | 190109
Copyright © 2019 Savant Systems, LLC
Technical Specifications
3. Installation Instructions
1. Cut neon strip to desired length, cutting only along marked dotted lines, in 1 meter
increments, as shown in P1 and P2.
2. Install power connector at transmission end of strip:
Carefully apply glue to the outer jacket, taking care not to get glue on any pins or core
wiring, then insert the male connector (B) into the light body in the direction of the
arrow (P3), ensuring the terminal pins are aligned with the core wire of the strip.
NOTE: Glue surface will solidify after approximately 1 hour, and glue will be fully set
within approximately 8 hours.
Ensure that the connector is tted securely and fully with all terminal pins aligned and
seated (P4).
Install Clip (C) in the direction of the arrow as shown in P5 and P6.
Carefully attach xing box (E) as shown in P7 and P8, ensuring that it aligns with
vertical groove in connector (B) and snaps securely into place over the clip (C).
Rating:
Voltage: 24V DC
Energy Consumption: 10.8W per Meter
Light Output: 90 Lumens per Meter
Dimensions:
Height: 0.4 in (10 mm)
Width: 0.8 in (20 mm)
Length: 32.8 ft (10 M)
Connectors add 2mm x 4mm
Environmental:
IP67 rated water resistance
4 of 5
Savant Neon Light Strip Installation Guide
009-1765-01 | 190109
Copyright © 2019 Savant Systems, LLC
3. Install tail plug at non-transmission end of strip:
Carefully apply glue (D) to the end cap (G) and insert into the non-transmission end of the strip, as shown in P9 and P10.
NOTE: Glue surface will solidify after approximately 1 hour, and glue will be fully set within approximately 8 hours.
Install clip (C) as shown in P11 and P12:
Carefully attach xing box (E) as shown in P13 and P14, ensuring that it aligns with vertical groove in tail plug (G) and snaps securely into place
over the clip (C).
4. Install track and ax strip to track:
Install track (K) using screw (H), then feed strip (A) into track as shown in P15 and P16
5 of 5
Savant Neon Light Strip Installation Guide
009-1765-01 | 190109
Copyright © 2019 Savant Systems, LLC
4. Installation Precautions
The following precautions should be followed during installation and use of Savant Neon Light Strips:
Strip should never be installed in
track twisted as shown below:
Strip should never be installed
hanging vertically without support:
Strip should never be installed
hanging horizontally over a gap
without support:
Strip should be bent or curved only
laterally as shown below:
Diameter of all bends and curves in
strips should never be smaller than
120 mm:
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5

Savant STP-NEON10MOD-00 Deployment Guide