9
Warning!
— The hood cannot be connected to flues of
other appliances that run on energy
sources other than electricity.
— When the hood is used at the same time
of other appliances that run on energy
sources other than electricity, provision
must be made for an adequate supply of
air.
—No food must be cooked flambé
underneath the hood.
The use of an unprotected flame is
dangerous for the filters and could cause
fires.
Therefore, never use an open flame under
the hood. When frying foods, never leave
the pan alone because the cooking oil
could flare up.
— Please, keep to the provisions of official
directives regarding the question of fume
discharge.
— The manufacturers refuse to accept any
responsibility for damage to the hood or
its catching on fire because of failure to
observe the above instructions.
Suggestions for the installation and
use of the hood
— The horizontal sections of the pipe must
be slanted slightly upwards (about 10%)
to ensure an easy flow of the air outwards.
— The best performance of the unit is
obtained in the external exhaust model
(suction), therefore in the limits of the
possibilities it is advised to use the
external exhaust (suction) type.
— The best performances are obtained with
short pipes (max. 4 m) and with few
curves.
Electric connection
Before completing any connection, make
sure the house voltage corresponds with
the voltage indicated on the label affixed
inside the hood.
The hood is supplied with a standard plug;
connect it to a correspondingly standard
socket. In the case is intended to connect
the appliance permanently to the mains
after having removed the plug supplied,
must be fitted a two-pole switch conforming
View of the hood
1. Control panel
2. Operating light
3. Grease filters
Mounting of grease filters
Attention! The grease filters are supplied
not mounted and packed in order to avoid
damages during transport of the hood.
Fit the pins of the filters (those located on
the opposite side of the grease filter handle)
on the slots of the grease filter housing, then
use the handles of the filter to lock them
(Abb.1 a,b).
Pull the handles backwards to loosen the
filter. (Abb. 1 c,d).
Use
Two systems are available:
— External exhaust system
— Internal recycle system
External exhaust system
The air is vented outdoors by a 150 mm duct
which must be connected to connecting ring
with no return valve on top of the motor
package.
Internal recycle system
The air is filtered through a carbon filter and
recirculated into the room through the top
sides of the chimney (Fig. 2).
This version is used when there is no exhaust
duct for venting outdoors or when it is
impossible to install one.
Mounting of carbon filter (for
recirculating version)
a. Remove the grease filters (Fig. 1 c,d).
b. Fix the carbon filter with its two screws
(Fig. 7).
c. Refit the grease filters.
Attention
When installed, the hood must be not less
than 60 cm. above electric burners or 70
cm. above gas or mixed-fuel burners.
GB