Shinko SGMW User manual

Type
User manual

This manual is also suitable for

S G M - - -
Option
0: No option needed, 1: Multi-rotation trimmer
2: Moisture-proof treatment
3: Multi-rotation trimmer+Moisture-proof treatment
Power supply
0: 100 to 240 V AC, 1: 24 V AC/DC
*2
Output 2
*1
Output
*2
, Output 1
*1
Input
Series name
SGM: 1-output, SGMW: 2-outputs
SGML: 1-output + Serial communication
*1SGMW only
*2SGM, SGMLonly
(
For detailed input/
output spec, refer to the full Instruction Manual.
)
Default Display
Custom display
mode 3
Custom display
mode 4
Unlit
display mode
All unlit
display mode
Model display
mode
RUN display
mode 1
DISP
key
RUN display
mode 2
RUN display
mode 3
RUN display
mode 4
RUN display
mode 5
RUN display
mode 6
Custom display
mode 1
DISP
key
DISP
key
DISP
key
DISP
key
DISP
key
DISP
key
Custom display
mode 2
DISP
key
DISP
key
DISP
key
DISP
key
DISP
key
DISP
key
MODE
key
for 5 sec
MODE
key
Input
setting mode
Output 1
setting mode
Output 2
setting mode
Instrument
setting mode
Communication
setting mode
C
ustom
display
s
mode
Manual mode
DOWN
key
for 3 sec
DISP
key
for 3 sec
Decimal
point place
DISP
key
Output 0%
value
DISP
key
Output
100% value
DISP
key
Indication
unit
DISP
key
Save
settings
DISP
key
Output 1
type
O
utput
1
decimal
p
oint place
Indication
value at
output 0%
Indication
value at
output 100%
Output 1
low limit
Output 1
high limit
Output 1
Normal/Reverse
Save
settings
Filter time
constant
Sensor
correction
Indication
time
Auto/Manual
Manual mode
auto return time
Save
settings
Instrument
number
Communication
speed
Data bit/
Parity
Stop bit
Response
delay time
Save
settings
Multi-Display
A
Multi-Display
B
Save
settings
Default Display
Default Display
Default Display
Default Display
Default Display
MODE
k
ey, or after
Manual mode auto return
time has elapsed
DISP
key
for 3 sec
DISP
key
DISP
key
for 3 sec
MODE
key
MODE
key
MODE
key
MODE
key
MODE
key
DISP
key
for 3 sec
DISP
key
DIS
P
key
DISP
key
DISP
key
DISP
key
DISP
key
DISP
key
DISP
key
DISP
key
DISP
key
DISP
key
DISP
key
DISP
key
for 3 sec
DISP
key
DISP
key
DISP
key
DISP
key
for 3 sec
Square root
function
DISP
key
Low lever
cutoff
DISP
key
D
ISP
key
DISP
key
DISP
k
ey
DISP
key
DISP
key
DISP
key
Output 1
ratio
Output 1
bias
Input point 1
O
utput
1
output
value 1
Input point
2
O
utput
1
output
value 2
DISP
key
DISP
key
DISP
key
DISP
key
DISP
key
DISP
key
DISP
key
Output 2
type
O
utput 2
decimal
p
oint place
Indication
value at
output 0%
Indication
value at
output 100%
Output 1
low limit
Output 2
high limit
Output 2
Normal/Reverse
Save
settings
Default Display
DISP
key
DISP
key
DISP
key
DISP
key
DISP
key
DISP
key
DISP
key
Output 2
ratio
Output 2
bias
Input point 1
Output
2
output
value 1
Input point
2
O
utput 2
output
value 2
DISP
key
DISP
key
DISP
key
DISP
key
DISP
key
DISP
key
DISP
key
Ratio setting
method
DISP
key
No.
1
No. 6
No.
1
No.
6
No. 1 COM
No. 2 NC
No. 3 YB(+)
No. 4 YA(-)
No. 5 NC
No.
6
COM
QUICK REFERENCE [Applicable model: SGM, SGMW, SGML] No. SGM12JE1 2018.10
Decimal point place
No decimal point
1 digit after point
2 digits after point
3 digits after point
Indication unit
No unit
%
mA
V
°C
Square root function
Enabled
Disabled
Save settings
Save
Not save
Output 1, Output 2 type
4 to 20 mA
0 to 20 mA
0 to 16 mA
2 to 10 mA
0 to 10 mA
0 to 10 mV
0 to 100 mV
0 to 1 V
0 to 5 V
1 to 5 V
0 to 10 V
-5 to 5 V
1
Output 1,2 decimal point place
No decimal point
1 digit after point
2 digits after point
3 digits after point
Output 1,2 Normal/Reverse
Normal
Reverse
Auto/Manual
Auto
Manual
Ratio setting method
Ratio setting
Output value setting
Communication speed
9600 bps
19200 bps
38400 bps
Data bit/Parity
8 bits/No parity
8 bits/Even
8 bits/Odd
Stop bit
1 bit
2 bits
Selection Item List
Model Name
Circuit Configuration
SGM, SGML
SGMW
Characters
Indication
Number, °C/°F -1 0 1 2 3 4 5 6 7 8 9 °C °F
Indication
Alphabet
A B C D E F G H I J K L M
Indication
Alphabet
N O P Q R S T U V W X Y Z
Terminal Arrangement
SGM, SGML SGMW SGML only
RS-485 serial communication
Modular jack pin arrangement
Key Operation Flowchart
Display Mode
: Available only for the SGMW.
For the details of the display mode, refer to the full Instruction Manual.
Default Display
If the MODE and DISP keys (in that order) are pressed together for approx. 3
seconds in any display mode, the display mode will become the Default Display.
Once the Default Display is set, the DISP key will be in lock status.
If the DISP key is pressed for approx. 3 seconds, the key lock status will be
cancelled.
If the DISP key is pressed while the DISP key is in lock status, Multi-Display A
will indicate
.
Setting Mode
Output 2 setting mode is available only for the SGMW.
Communication setting mode is available only for the SGML.
If the MODE key is pressed for approx. 5 seconds in each setting mode, the unit
will move to the Default Display.
1 Not available for the SGMW.
和文は裏面をご覧下さい。
Output
circuit
C
ommu
-
nication
circuit
Modular
jack
CPU
Input
circuit
Front
trimmer
Power
circuit
Dis
play/
Setting key
circuit
A/V
+
-
+
-
For SGML
24 V
power
circuit
250
Power for
2-wire
transmitter
1
4
8
13
14
12
9
Output 1
circuit
Output 2
circuit
CPU
Input
circuit
Front
trimmer
Power
circuit
Display/
Setting key
circuit
A/V
+
-
+
-
24V
power
circuit
250
Power for
2-wire
transmitter
+
-
1
4
6
3
5
7
8
10
11
  • Page 1 1

Shinko SGMW User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI