S G M □ - □ □ □ □ - □ - □
Option
0: No option needed, 1: Multi-rotation trimmer
2: Moisture-proof treatment
3: Multi-rotation trimmer+Moisture-proof treatment
Power supply
0: 100 to 240 V AC, 1: 24 V AC/DC
*2
Output 2
*1
Output
*2
, Output 1
*1
Input
Series name
SGM: 1-output, SGMW: 2-outputs
SGML: 1-output + Serial communication
*1:SGMW only
*2:SGM, SGMLonly
output spec, refer to the full Instruction Manual.
Default Display
Custom display
mode 3
Custom display
mode 4
Unlit
display mode
All unlit
display mode
Model display
mode
RUN display
mode 1
DISP
RUN display
mode 2
RUN display
mode 3
RUN display
mode 4
RUN display
mode 5
RUN display
mode 6
Custom display
mode 1
DISP
DISP
DISP
DISP
DISP
DISP
Custom display
mode 2
key
DISP
DISP
DISP
DISP
DISP
MODE
key
for 5 sec
MODE
key
Input
setting mode
Output 1
setting mode
Output 2
setting mode
setting mode
Communication
setting mode
display
Manual mode
key
for 3 sec
key
for 3 sec
Decimal
point place
key
Output 0%
value
key
Output
100% value
key
Indication
unit
key
Save
settings
key
Output 1
type
decimal
value at
output 0%
value at
output 100%
Output 1
low limit
Output 1
high limit
Output 1
Normal/Reverse
Save
settings
Filter time
constant
Sensor
correction
Indication
time
Auto/Manual
Manual mode
auto return time
Save
settings
Instrument
number
Communication
speed
Data bit/
Parity
Stop bit
Response
delay time
Save
settings
Multi-Display
A
Multi-Display
B
Save
settings
Default Display
Default Display
Default Display
Default Display
Default Display
Manual mode auto return
time has elapsed
key
for 3 sec
key
for 3 sec
MODE
key
MODE
key
key
key
MODE
key
key
for 3 sec
key
key
key
key
key
key
key
key
key
key
key
key
key
for 3 sec
key
key
key
key
for 3 sec
Square root
function
key
Low lever
cutoff
key
Output 1
ratio
Output 1
bias
Input point 1
output
value 1
Input point
2
output
value 2
Output 2
type
decimal
value at
output 0%
value at
output 100%
Output 1
low limit
Output 2
high limit
Output 2
Normal/Reverse
Save
settings
Default Display
Output 2
ratio
Output 2
bias
Input point 1
output
value 1
Input point
2
output
value 2
Ratio setting
method
key
No. 6
No. 1 COM
No. 2 NC
No. 3 YB(+)
No. 4 YA(-)
No. 5 NC
QUICK REFERENCE [Applicable model: SGM, SGMW, SGML] No. SGM12JE1 2018.10
Decimal point place
No decimal point
1 digit after point
2 digits after point
3 digits after point
Indication unit
No unit
%
mA
V
°C
Square root function
Enabled
Disabled
Save settings
Save
Not save
Output 1, Output 2 type
4 to 20 mA
0 to 20 mA
0 to 16 mA
2 to 10 mA
0 to 10 mA
0 to 10 mV
0 to 100 mV
0 to 1 V
0 to 5 V
1 to 5 V
0 to 10 V
-5 to 5 V
※1
Output 1,2 decimal point place
No decimal point
1 digit after point
2 digits after point
3 digits after point
Output 1,2 Normal/Reverse
Normal
Reverse
Auto/Manual
Auto
Manual
Ratio setting method
Ratio setting
Output value setting
Communication speed
9600 bps
19200 bps
38400 bps
Data bit/Parity
8 bits/No parity
8 bits/Even
8 bits/Odd
Stop bit
1 bit
2 bits
Model Name
Circuit Configuration
SGM, SGML
SGMW
Characters
Indication
Number, °C/°F -1 0 1 2 3 4 5 6 7 8 9 °C °F
Indication
A B C D E F G H I J K L M
Indication
N O P Q R S T U V W X Y Z
Terminal Arrangement
SGM, SGML SGMW SGML only
RS-485 serial communication
Modular jack pin arrangement
Key Operation Flowchart
Display Mode
• : Available only for the SGMW.
• For the details of the display mode, refer to the full Instruction Manual.
Default Display
• If the MODE and DISP keys (in that order) are pressed together for approx. 3
seconds in any display mode, the display mode will become the Default Display.
• Once the Default Display is set, the DISP key will be in lock status.
• If the DISP key is pressed for approx. 3 seconds, the key lock status will be
cancelled.
• If the DISP key is pressed while the DISP key is in lock status, Multi-Display A
will indicate
.
Setting Mode
• Output 2 setting mode is available only for the SGMW.
• Communication setting mode is available only for the SGML.
• If the MODE key is pressed for approx. 5 seconds in each setting mode, the unit
will move to the Default Display.
※1 Not available for the SGMW.
和文は裏面をご覧下さい。
Output
circuit
nication
circuit
CPU
Input
circuit
Power
circuit
Setting key
circuit
For SGML
power
circuit
Power for
2-wire
transmitter
1
4
8
13
14
12
9
Output 1
circuit
Output 2
circuit
CPU
Input
circuit
trimmer
Power
circuit
Setting key
circuit
A/V
power
circuit
250
Power for
2-wire
transmitter
1
4
6
3
5
7
8
10
11