Gigabyte H261-H60 User manual

Type
User manual
H261-H60
HCI Server – Intel DP 2U 4 Nodes Server
User Manual
Rev. 1.0
Copyright
© 2019 GIGA-BYTE TECHNOLOGY CO., LTD. All rights reserved.
The trademarks mentioned in this manual are legally registered to their respective owners.
Disclaimer
Information in this manual is protected by copyright laws and is the property of GIGABYTE.
Changes to the specications and features in this manual may be made by GIGABYTE without
prior notice. No part of this manual may be reproduced, copied, translated, transmitted, or
published in any form or by any means without GIGABYTE's prior written permission.
Documentation Classications
In order to assist in the use of this product, GIGABYTE provides the following types of documentation:
User Manual: detailed information & steps about the installation, conguration and use of this
product (e.g. motherboard, server barebones), covering hardware and BIOS.

User Guide: detailed information about the installation & use of an add-on hardware or
software component (e.g. BMC rmware, rail-kit) compatible with this product.
Quick Installation Guide: a short guide with visual diagrams that you can reference easily for
installation purposes of this product (e.g. motherboard, server barebones).
Please see the support section of the online product page to check the current availability of these
documents.
For More Information
For related product specications, the latest rmware and software, and other information please visit our website at
http://www.gigabyte.com
For GIGABYTE distributors and resellers, additional sales & marketing materials are available from our reseller
portal: http://reseller.b2b.gigabyte.com
For further technical assistance, please contact your GIGABYTE representative or visit
https://esupport.gigabyte.com/ to create a new support ticket
For any general sales or marketing enquiries, you may also message GIGABYTE server directly by email:
Conventions
The following conventions are used in this user's guide:
NOTE!
Gives bits and pieces of additional
information related to the current topic.
CAUTION!
Gives precautionary measures to
avoid possible hardware or software problems.
WARNING!
Alerts you to any damage that might
result from doing or not doing specic actions.
Server Warnings and Cautions
Before installing a server, be sure that you understand the following warnings and cautions.
WARNING!
To reduce the risk of electric shock or damage to the equipment:
Do not disable the power cord grounding plug. The grounding plug is an important safety
feature.
Plug the power cord into a grounded (earthed) electrical outlet that is easily accessible at all
times.
Unplug the power cord from the power supply to disconnect power to the equipment.
Do not route the power cord where it can be walked on or pinched by items placed against it.
Pay particular attention to the plug, electrical outlet, and the point where the cord extends from
the server.
WARNING!
To reduce the risk of personal injury from hot surfaces, allow the drives and the internal
system components to cool before touching them.
WARNING!
This server is equipped with high speed fans. Keep away from hazardous moving fan
blades during servicing.
CAUTION!
Do not operate the server for long periods with the access panel open or removed. Operat-
ing the server in this manner results in improper airow and improper cooling that can lead to
thermal damage.
Danger of explosion if battery is incorrectly replaced.
Replace only with the same or equivalent type recommended by the manufacturer.
Dispose of used batteries according to the manufacturer’s instructions.
Electrostatic Discharge (ESD)
CAUTION!
ESD CAN DAMAGE DRIVES, BOARDS, AND OTHER PARTS. WE RECOMMEND THAT YOU
PERFORM ALL PROCEDURES AT AN ESD WORKSTATION. IF ONE IS NOT AVAILABLE,
PROVIDE SOME ESD PROTECTION BY WEARING AN ANTI-STATIC WRIST STRAP AT-
TACHED TO CHASSIS GROUND -- ANY UNPAINTED METAL SURFACE -- ON YOUR SERVER
WHEN HANDLING PARTS.
Always handle boards carefully. They can be extremely sensitive to ESD. Hold boards only by
their edges without any component and pin touching. After removing a board from its protective
wrapper or from the system, place the board component side up on a grounded, static free sur-
face. Use a conductive foam pad if available but not the board wrapper. Do not slide board over
any surface.
System power on/off: To remove power from system, you must remove the system from rack.
Make sure the system is removed from the rack before opening the chassis, adding, or removing
any non hot-plug components.
Hazardous conditions, devices and cables: Hazardous electrical conditions may be present
on power, telephone, and communication cables. Turn off the system and discon-nect the cables
attached to the system before servicing it. Otherwise, personal injury or equipment damage can
result.
Electrostatic discharge (ESD) and ESD protection: ESD can damage drives, boards, and
other parts. We recommend that you perform all procedures in this chapter only at an ESD work-
station. If one is not available, provide some ESD protection by wearing an antistatic wrist strap
attached to chassis ground (any unpainted metal surface on the server) when handling parts.
ESD and handling boards: Always handle boards carefully. They can be extremely sensi-tive to
electrostatic discharge (ESD). Hold boards only by their edges. After removing a board from its
protective wrapper or from the system, place the board component side up on a grounded, static
free surface. Use a conductive foam pad if available but not the board wrapper. Do not slide
board over any surface.
Installing or removing jumpers: A jumper is a small plastic encased conductor that slips over
two jumper pins. Some jumpers have a small tab on top that can be gripped with n-gertips or
with a pair of ne needle nosed pliers. If the jumpers do not have such a tab, take care when us-
ing needle nosed pliers to remove or install a jumper; grip the narrow sides of the jumper with the
pliers, never the wide sides. Gripping the wide sides can dam-age the contacts inside the jumper,
causing intermittent problems with the function con-trolled by that jumper. Take care to grip with,
but not squeeze, the pliers or other tool used to remove a jumper, or the pins on the board may
bend or break.
CAUTION!
Risk of explosion if battery is replaced incorrectly or with an incorrect type. Replace the battery
only with the same or equivalent type recommended by the manufacturer. Dispose of used bat-
teries according to the manufacturer’s instructions.
- 7 -
Table of Contents
Chapter 1 Hardware Installation ...................................................................................11
1-1 Installation Precautions .................................................................................. 11
1-2 Product Specications .................................................................................... 12
1-3 System Block Diagram ................................................................................... 16
Chapter 2 System Appearance ..................................................................................... 17
2-1 Front View ...................................................................................................... 17
2-2 Rear View ....................................................................................................... 17
2-3 Front Panel LED and Buttons ........................................................................ 18
2-4 Rear System LAN LEDs ................................................................................. 19
2-5 Power Supply Unit LED .................................................................................. 20
2-6 Hard Disk Drive LEDs .................................................................................... 21
Chapter 3 System Hardware Installation ......................................................................23
3-7 Removing Chassis Cover ............................................................................... 24
3-8 Removing and Installing the Fan Duct ........................................................... 25
3-9 Installing the CPU and Heat Sink ................................................................... 26
3-10 Installing the Memory ..................................................................................... 28
3-10-1 Six Channel Memory Conguration ........................................................................28
3-10-2 Installing a Memory ...............................................................................................29
3-10-3 DIMM Population Table ..........................................................................................29
3-10-4 Intel Optane DCPMM DIMM Population Rule ........................................................30
3-11 Installing the PCI Expansion Card ................................................................. 31
3-12 Installing the Hard Disk Drive ......................................................................... 32
3-13 Replacing the FAN Assemblly ........................................................................ 33
3-14 Replacing the Power Supply .......................................................................... 34
3-15 Replacing Power Distribution Board Cage ..................................................... 35
3-16 Cable Routing ................................................................................................ 36
Chapter 4 Motherboard Components ...........................................................................37
4-17 Motherboard Components ............................................................................. 37
4-18 Jumper Setting .............................................................................................. 38
Chapter 5 BIOS Setup ..................................................................................................39
5-1 The Main Menu .............................................................................................. 41
5-2 Advanced Menu ............................................................................................. 43
5-2-1 iSCSI Conguration ................................................................................................44
5-2-2 Intel(R) Virtual RAID on CPU .................................................................................45
5-2-3 Trusted Computing .................................................................................................46
- 8 -
5-2-4 Serial Port Console Redirection .............................................................................47
5-2-5 COM1/COM2 Serial Over LAN/Legacy/Serial Port for Out-of-Band EMS .................
Console Redirection Settings ...............................................................................................48
5-2-6 SIO Conguration ...................................................................................................51
5-2-7 PCI Subsystem Settings .........................................................................................54
5-2-8 Network Stack ........................................................................................................55
5-2-9 CSM Conguration .................................................................................................56
5-2-10 Post Report Conguration ......................................................................................58
5-2-11 NVMe Conguration ...............................................................................................59
5-2-12 USB Conguration ..................................................................................................60
5-2-13 Chipset Conguration .............................................................................................61
5-3 Chipset Setup Menu ....................................................................................... 62
5-3-1 Processor Conguration .........................................................................................63
5-3-2 Pre-Socket Conguration .......................................................................................65
5-3-3 Common RefCode Conguration ...........................................................................67
5-3-4 UPI Conguration ...................................................................................................68
5-3-5 Memory Conguration ............................................................................................70
5-3-6 Memory Topology ...................................................................................................72
5-3-7 Memory RAS Conguration ....................................................................................73
5-3-8 IIO Conguration ....................................................................................................74
5-3-9 Intel® VT for Directed I/O (VT-d) ...........................................................................75
5-3-10 Inter® VMD Technology .........................................................................................76
5-3-11 Advanced Power Management Conguration ........................................................77
5-3-12 CPU P State Control ...............................................................................................78
5-3-13 Hardware PM State Control ....................................................................................79
5-3-14 CPU C State Control ..............................................................................................80
5-3-15 Package C State Control ........................................................................................81
5-3-16 CPU-Advanced PM Tuning .....................................................................................82
5-3-17 PCH Conguration .................................................................................................84
5-3-18 PCH SATA Conguration ........................................................................................85
5-3-19 PCH sSATA Conguration ......................................................................................87
5-3-20 Miscellaneous Conguration ..................................................................................89
5-3-21 Server ME Conguration ........................................................................................90
5-3-22 Runtime Error Logging ...........................................................................................91
5-3-23 Whea Settings ........................................................................................................92
5-3-24 Memory Error Enabling ...........................................................................................93
5-3-25 PCIe Error Enabling ................................................................................................94
5-4 Server Management Menu ............................................................................. 95
5-4-1 System Event Log ..................................................................................................97
5-4-2 View FRU Information ............................................................................................98
5-4-3 BMC Network Conguration ...................................................................................99
5-4-4 IPv6 BMC Network Conguration .........................................................................100
- 9 -
5-5 Security Menu .............................................................................................. 101
5-5-1 Secure Boot .........................................................................................................102
5-5-2 Key Management ...............................................................................................103
5-6 Boot Menu .................................................................................................... 105
5-6-1 UEFI NETWORK Drive BBS Priorities ................................................................107
5-6-2 1UEFI Application Boot Priorities ............................................................... 108
5-7 Save & Exit Menu ......................................................................................... 109
5-8 BIOS POST Codes .......................................................................................111
5-8-1 AMI Standard - PEI ............................................................................................... 111
5-8-2 AMI Standard - DXE ............................................................................................. 111
5-8-3 AMI Standard - ERROR .......................................................................................113
5-8-4 Intel UPI POST Codes .......................................................................................... 114
5-8-5 Intel UPI Error Codes ...........................................................................................114
5-8-6 Intel MRC POST Codes .......................................................................................115
5-8-7 Intel MRC Error Codes .........................................................................................115
5-8-8 Intel PM POST Codes ..........................................................................................116
5-8-9 Intel PM POST Codes ..........................................................................................116
5-9 BIOS POST Beep code (AMI standard) ....................................................... 117
5-9-1 PEI Beep Codes ...................................................................................................117
5-9-2 DXE Beep Codes .................................................................................................117
5-10 BIOS Recovery Instruction ........................................................................... 118
- 10 -
This page intentionally left blank
- 11 - Hardware Installation
1-1 Installation Precautions
The motherboard/system contain numerous delicate electronic circuits and components which
can become damaged as a result of electrostatic discharge (ESD). Prior to installation, carefully
read the service guide and follow these procedures:
Prior to installation, do not remove or break motherboard S/N (Serial Number) sticker or
warranty sticker provided by your dealer. These stickers are required for warranty validation.
Always remove the AC power by unplugging the power cord from the power outlet before
installing or removing the motherboard or oth er hardware
components.
When connecting hardware components to the internal connectors on the motherboard,
make sure they are connected tightly and securely.
When handling the motherboard, avoid touching any metal leads or connectors.
It is best to wear an electrostatic discharge (ESD) wrist strap when handling electronic
components such as a motherboard, CPU or memory. If you do not have an ESD wrist
strap, keep your hands dry and rst touch a metal object to eliminate static electricity.
Prior to installing the motherboard, please have it on top of an antistatic pad or within an
electrostatic shielding container.
Before unplugging the power supply cable from the motherboard, make sure the power
supply has been turned off.
Before turning on the power, make sure the power supply voltage has been set according to
the local voltage standard.
Before using the product, please verify that all cables and power connectors of your
hardware components are connected.
To prevent damage to the motherboard, do not allow screws to come in contact with the
motherboard circuit or its components.
Make sure there are no leftover screws or metal components placed on the motherboard or
within the computer casing.
Do not place the computer system on an uneven surface
.
Do not place the computer system in a high-temperature environment.
Turning on the computer power during the installation process can lead to damage to
system components as well as physical harm to the user.
If you are uncertain about any installation steps or have a problem related to the use of the
product, please consult a certied computer technician.
Chapter 1 Hardware Installation
Hardware Installation - 12 -
1-2 ProductSpecications
Socket
Socket
Security
Security Serve rOperating Properties
Power S upply
CPU 2nd Generation Intel® Xeon® Scalable and Intel® Xeon® Scalable Processors
Intel® Xeon® Platinum Processor, Intel® Xeon® Gold Processor, Intel® Xeon®
Silver Processor and Intel® Xeon® Bronze Processor
CPU TDP up to 165W
NOTE:
If only 1 CPU is installed, some PCIe or memory functions might be unavailable
This device does not support Intel Omni-Path function
Socket
Socket
Security
Security Serve rOperating Properties
Power S upply
Socket Per node:
2 x LGA 3647
Total:
8 x LGA 3647
Socket P
Socket
Socket
Security
Security Serve rOperating Properties
Power S upply
Chipset Intel® C621 Express Chipset
Socket
Socket
Security
Security Serve rOperating Properties
Power S upply
Memory Per node:
16 x DIMM slots
Total:
64 x DIMM slots
DDR4 memory supported only
6-channel memory architecture
RDIMM modules up to 64GB supported
LRDIMM modules up to 128GB supported
Supports Intel® Optane™ DC Persistent Memory (DCPMM)
1.2V modules: 2933/2666/2400/2133 MHz
Maximum veried DCPMM conguration:
Ambient temperature 35°C
2nd Generation Intel® Xeon® Scalable processor 165W (Max.)
DCPMM 256GB x2 pcs (Per Node)
DCPMM installation locations:
DIMM_P1_( G1, J1)
NOTE:
1. 2933MHz for 2nd Generation Intel® Xeon® Scalable Processors only
2. Intel® Optane™ DC Persistent Memory for 2nd Generation Intel® Xeo
Scalable Processors only
3. The maximum number of DCPMM that can be installed is based on a maximum
operating (ambient) temperature of 35°C
4. To enquire about installing a greater number of DCPMM, please consult with
your GIGABYTE technical or sales representative
NOTE:
Wereservetherighttomakeanychangestotheproductspecicationsandproduct-related
information without prior notice.
- 13 - Hardware Installation
Socket
Socket
Security
Security Serve rOperating Properties
Power S upply
LAN Per node:
1 x Dedicated management port
Total:
4 x Dedicated management ports
1 x 10/100/1000 *CMC global management port
*CMC: Chassis Management Controller, to monitor all status of computing nodes
* Please contact FAE if NCSI function of OCP mezzanine card is needed
Socket
Socket
Security
Security Serve rOperating Properties
Power S upply
Video Integrated in Aspeed® AST2500
2D Video Graphic Adapter with PCIe bus interface
1920x1200@60Hz 32bpp, DDR4 SDRAM
Management chip in CMC board:
Integrated in Aspeed® AST1250
Integrated in Aspeed® AST2520A2-GP
Socket
Socket
Security
Security Serve rOperating Properties
Power S upply
Storage Per node:
3 x 3.5" SATA/SAS hot-swappable HDD/SSD bays
Onboard SATA DOM support (PIN_7, PIN_8 or external cable)
Total:
12 x 3.5" SATA/SAS hot-swappable HDD/SSD bays
2.5" HDD/SSD supported
SAS card is required for SAS devices support
Socket
Socket
Security
Security Serve rOperating Properties
Power S upply
RAID Intel® SATA RAID 0/1/5
Socket
Socket
Security
Security Serve rOperating Properties
Power S upply
Expansion Slot Per node:
1 x Half-length low-prole slot with PCIe x16 (Gen3 x16 bus)
1 x Half-length low-prole slot with PCIe x8 (Gen3 x8 bus)
1 x OCP mezzanine slot with PCIe Gen3 x16 bus
Total:
4 x Half-length low-prole slot with PCIe x16 (Gen3 x16 bus)
4 x Half-length low-prole slot with PCIe x8 (Gen3 x8 bus)
4 x OCP mezzanine slot with PCIe Gen3 x16 bus
Socket
Socket
Security
Security Serve rOperating Properties
Power S upply
Internal I/O Per node:
1 x COM header
1 x COM header
1 x TPM header
1 x BMC SGPIO header
1 x JTAG BMC header
1 x PLD header
1 x Clear CMOS jumper
1 x IPMB connector
1 x Buzzer
Hardware Installation - 14 -
Socket
Socket
Security
Security Serve rOperating Properties
Power S upply
Front I/O Per node:
1 x Power button with LED
1 x ID button with LED
1 x Status LED
Total:
4 x Power button with LED
4 x ID button with LED
4 x Status LED
*1 x CMC status LED
*Only one CMC status LED per system
Socket
Socket
Security
Security Serve rOperating Properties
Power S upply
Rear Panel I/O Per node:
2 x USB 3.0
1 x VGA
1 x RJ45 MLAN
1 x ID LED
Total:
8 x USB 3.0
4 x VGA
4 x RJ45 MLAN
4 x ID LEDs
*1 x CMC global management port
*Only one CMC global management port per system
Socket
Socket
Security
Security Serve rOperating Properties
Power S upply
Backplane I/O 12 x ports
12Gb/s & 6Gb/s compatible
Socket
Socket
Security
Security Serve rOperating Properties
Power S upply
TPM 1 x TPM header with LPC interface
Optional TPM2.0 kit: CTM000
- 15 - Hardware Installation
Socket
Socket
Security
Security Serve rOperating Properties
Power S upply
Power Supply 2 x 2200W redundant PSUs
80 PLUS Platinum
AC Input:
100-127V~/ 14A, 47-63Hz
200-240V~/ 12.6A, 47-63Hz
DC Output:
Max 1200W/ 100-127V~
+12.12V/ 95.6A
+12Vsb/ 3.5A
- Max 2200W/ 200-240V
+12.12V/ 178.1A
+12Vsb/ 3.5A
NOTE:
The system power supply requires C19 type power cord
2000W 80 PLUS Titanium PSU as an option
Socket
Socket
Security
Security Serve rOperating Properties
Power S upply
System
Management
Aspeed® AST2500 management controller
Avocent® MergePoint IPMI 2.0 web interface:
Network settings
Network security settings
Hardware information
Users control
Services settings
IPMI settings
Sessions control
LDAP settings
Power control
Fan proles
Voltages, fans and temperatures monitoring
System event log
Events management (platform events, trap settings, email settings)
vKVM & vMedia (HTML5)
Socket
Socket
Security
Security Serve rOperating Properties
Power S upply
Operating
Properties
Operating temperature: 10°C to 35°C
Operating humidity: 8-80% (non-condensing)
Non-operating temperature: -40°C to 60°C
Non-operating humidity: 20%-95% (non-condensing)
Socket
Socket
Security
Security Serve rOperating Properties
Power S upply
System
Dimension
2U 4 Nodes - Rear access
440 x 87 x 820
Hardware Installation - 16 -
1-3 System Block Diagram
- 17 - System Appearance
Chapter 2 System Appearance
2-1 Front View
No. Decription
1. Front Panel LEDs and buttons
Please Go to Chapter 2-3 Front Panel LED and Buttons for detail description of
function LEDs.
2-2 Rear View
No. Decription
1. Chassis management Console port
2. USB 3.0 ports
3. VGA port
4. 10/100/1000 Server management LAN port
Primary
PSU
Secondary
PSU
1
2 3 4
1 1
Node 1 Node 2 Node 3 Node 4
System Appearance - 18 -
2-3 Front Panel LED and Buttons
No. Name Color Status Description
1. System
Status LED
Green On System is operating normally.
Amber
On
Critical condition, may indicates:
System fan failure
System temperature
Blink
Non-critical condition, may indicates:
Redundant power module failure
Temperature and voltage issue
Chassis intrusion
N/A Off
Non-critical condition, may indicates:
Redundant power module failure
Temperature and voltage issue
Chassis intrusion
2. Power button
with LED
Green On System is powered on
Green Blink System is in ACPI S1 state (sleep mode)
N/A Off
System is not powered on or in ACPI S5 state (power
off)
System is in ACPI S4 state (hibernate mode)
3. ID Button
with LED
Blue On System identication is active.
N/A Off System identication is disabled.
4. Enclosure
Green On System is operating normally.
Amber
On
Critical condition, may indicates:Power
module failureSystem fan failurePower supply
voltage issueSystem temperature
Blink
Non-critical condition, may indicates:Redundant
power module failureTemperature and
voltage issueChassis intrusion
2
2
4
1
1
3
3
2
2
1
1
3
3
System Appearance - 19 -
2-4 Rear System LAN LEDs
No. Name Color Status Description
1. 10GbE
Speed LED
Yellow On 10Gbps data rate
Green On 1Gbps data rate
N/A Off 100 Mbps data rate
2.
10GbE
Link/
Activity LED
Green
On Link between system and
network or no access
Blink Data transmission or receiving is occurring
N/A Off No data transmission or receiving is occurring
1 2
System Appearance - 20 -
2-5 Power Supply Unit LED
PSU LED
State Description
OFF No AC power to all power supplies
0.5Hz Green Blinking AC present / only standby on / Cold redundant mode
2Hz Green Blinking Power supply rmware updateing mode
Amber
AC cord unplugged or AC power lost; with a second
power supply in parallel still with AC input power
Power supply critical event causing shut down:
failure, OCP, OVP, fan failure and UVP
0.5Hz Amber Blinking
Power supply warning events where the
power supply continues to operate:
high temp, high power, high current and slow fan
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118

Gigabyte H261-H60 User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI