Baso INT10A, INT11A Installation guide

  • Hello, I'm here to help you with your BASO Orifice Kit. I've reviewed the installation instructions, and I understand the kits are designed for Hi/Lo valves, including INT10A and INT11A series. The document details the replacement procedure for two valve configurations, emphasizing safety measures such as shutting off the gas supply and proper torque limits. I am ready to answer any questions you may have about this document or the installation process.
  • What Hi/Lo valve series are compatible with the INT10A kits?
    What is included in each INT10A or INT11A replacement orifice kit?
    What tool is required to replace the orifice?
    What is the maximum torque when tightening the orifice?
    What is the maximum torque when re-assembling the plug or coil stack?
Installation Instructions INT Orifice Kit
Issue Date November 4, 2020
INT10A Replacement Orifice Kit
© 2020 BASO Gas Products 1
Part No. BASO-INS-INT10A, Rev. - www.baso.com
INT10A Replacement Orifice Kits
Application
Replacement orifice kits for the following Hi/Lo Valves:
BGF362 Series
BGF378 Series
BGG258 Series
BGG262 Series
BGG278 Series
Kit includes:
Orifice
O-rings
Label (with orifice size)
Notes:
To replace the orifice in Figure 1, turn off the gas
before doing any work on the valve. Remove plug
(Item 1) to get to the orifice. Remove the old orifice
(Item 2) with the special tool SKT1132A-600H and
replace it with the new orifice (Item 2) making sure the
O-ring is in place. (Maximum torque 3 in/lbs.).
To replace the orifice in Figure 2, turn off the gas
before doing any work on the valve. Remove the E-clip
(Item 1) from the end of the coil, slide the coil off and
remove the coil stack (Item 2) with a 11/16 socket to
get to the orifice (Item 3). Remove the old orifice
(Item 3) with the special tool SKT1132A-600H and
replace with the new orifice (Item 3), making sure the
O-ring is in place. (Maximum torque 3 in/lbs.).
IMPORTANT: Do not over tighten. Over
torque will damage the O-ring.
!
WARNING: Risk of Explosion or Fire.
Do not exceed 8 in/lbs. when re-assembling the plug
(Item 1) or coil stack (Item 2) into the casting.
Ensure the O-ring is under the hex head to seal
against the casting. Test the external plug with
soapy water before turning the gas back on.
Replacement Orifice Kits
Part Number Orifice Size
INT10
A
-032H 0.032
INT10
A
-039H 0.039
INT10
A
-059H 0.059
INT10
A
-067H 0.067
INT10
A
-093H 0.093
INT10
A
-234H 0.234
Use Wrench SKT1132
A
-600H
Items in the
Replacement Kit
(SKT1132A-600H)
Wrench Sold
Separately
1/4”
Driver
Item 1
Item 2
Figure 1: Kit Parts
Items in the
Replacement Kit
(SKT1132A-600H)
Wrench Sold
Separately
1/4”
Driver
Item 1
Item 2
Item 3
Figure 2: Kit Parts
INT10A Replacement Orifice Kit
© 2020 BASO Gas Products 2
Part No. BASO-INS-INT10A, Rev. - www.baso.com
Application
Replacement orifice kits for the following Hi/Lo Valves:
BGF358 Series
Kit includes:
Orifice
O-rings
Label (with orifice size)
Note:
To replace the orifice in Figure 1, turn off the gas
before doing any work on the valve. Remove the E-clip
(Item 1) from the end of the coil, slide the coil off and
remove the coil stack (Item 2) with a 11/16 socket to
get to the orifice (Item 3). Remove the old orifice
(Item 3) with the special tool SKT1132A-601H and
replace with the new orifice (Item 3), making sure the
O-ring is in place. (Maximum torque 3 in/lbs.).
IMPORTANT: Do not over tighten. Over
torque will damage the O-ring.
!
WARNING: Risk of Explosion or Fire.
Do not exceed 8 in/lbs. when re-assembling the plug
(Item 1) or coil stack (Item 2) into the casting.
Ensure the O-ring is under the hex head to seal
against the casting. Test the external plug with
soapy water before turning the gas back on.
Replacement Orifice Kits
Part Number Orifice Size
INT11
A
-032H 0.032
INT11
A
-039H 0.039
INT11
A
-059H 0.059
INT11
A
-067H 0.067
INT11
A
-093H 0.093
INT11
A
-234H 0.234
Use Wrench SKT1132
A
-601H
Items in the
Replacement Kit
(SKT1132A-601H)
Wrench Sold
Separately
1/4”
Driver
Item 1
Item 2
Item 3
Figure 1: Kit Parts
/