Cooper ProtoNode FPC-N34 Instruction Sheet

Type
Instruction Sheet

This manual is also suitable for

Document Revision: 1.H
Auto Discovery
Template Revision: 53
ProtoNode FPC-N34 and ProtoNode FPC-N35
Startup Guide
For Interfacing Cooper Lighting Solutions Products:
Greengate and iLUMIN
To Building Automation Systems:
BACnet MS/TP, BACnet/IP, Modbus TCP/IP, Modbus RTU
and LonWorks
APPLICABILITY & EFFECTIVITY
Explains ProtoNode FPC-N34 and FPC-N35 hardware and how to install it.
The instructions are effective for the above as of February 2016.
Cooper Lighting Solutions ProtoNode Startup Guide
Page 2 of 60
Technical Support:
Thank you for purchasing the ProtoNode for Cooper Lighting Solutions.
Please call Cooper Lighting Solutions for Technical support of the ProtoNode product.
SMC does not provide direct support. If Cooper Lighting Solutions needs to escalate the concern, they
will contact Sierra Monitor Corporation for assistance.
Support Contact Information:
Email: Controltechsupport@cooperlighting.com
Website: www.cooperlighting.com
Cooper Lighting Solutions
1121 Highway 74 South
Peachtree City, GA 30269
P:770-486-4800
www.cooperlighting.com
Page 3 of 60
A Quick Start Guide
1. Record the information about the unit. (Section 2.1)
2. Set the Device COM setting that will be connected to ProtoNode. (Section 2.3.2)
3. Connect ProtoNode FPC-N34’s 3 pin RS-485 port to the Field Protocol cabling (Section 3.2),
or connect ProtoNode FPC-N35’s 2 pin LonWorks port to the Field Protocol cabling. (Section 3.3)
4. Connect Power to ProtoNode’s 6 pin connector. (Section 3.4)
5. Connect a PC to the ProtoNode via Ethernet cable and change the IP Address of the PC to the same
subnet as the ProtoNode. (Section 4.1)
6. Set the IP Address of the ProtoNode to the subnet of the intended Network and reset IP details of
the PC. (Section 4.3)
7. Set the BACnet settings via the Web Configurator GUI. (Section 4.3.1)
8. Use the Web Configurator Discovery function to configure the ProtoNode and to find any light panels
connected to the Device. (Section 4.3.1.2)
9. LonWorks (FPC-N35): The ProtoNode must be commissioned on the LonWorks Network. This
needs to be done by the LonWorks administrator using a LonWorks Commissioning tool. (Section
6)
Cooper Lighting Solutions ProtoNode Startup Guide
Page 4 of 60
Certifications
BTL MARK BACNET TESTING LABORATORY
LONMARK CERTIFICATION
The BTL Mark on ProtoNode is a symbol that indicates that a product has
passed a series of rigorous tests conducted by an independent laboratory
which verifies that the product correctly implements the BACnet features
claimed in the listing. The mark is a symbol of a high-quality BACnet product.
Go to http://www.BACnetInternational.net/btl/ for more information about the
BACnet Testing Laboratory. Click here for BACnet PIC Statement
LonMark International is the recognized authority for certification, education,
and promotion of interoperability standards for the benefit of manufacturers,
integrators and end users. LonMark International has developed extensive
product certification standards and tests to provide the integrator and user with
confidence that products from multiple manufacturers utilizing LonMark
devices work together. FieldServer Technologies has more LonMark Certified
gateways than any other gateway manufacturer, including the ProtoCessor,
ProtoCarrier and ProtoNode for OEM applications and the full featured,
configurable gateways.
Cooper Lighting Solutions ProtoNode Startup Guide
Page 5 of 60
TABLE OF CONTENTS
1 Introduction .......................................................................................................................................... 6
1.1 ProtoNode Gateway ....................................................................................................................... 7
2 BACnet/LonWorks Setup for ProtoCessor ProtoNode FPC-N34/FPC-N35 .................................... 8
2.1 Record Identification Data .............................................................................................................. 8
2.2 Point Count Capacity and Registers per Device ............................................................................ 8
2.3 Configuring Device IP Communications ......................................................................................... 9
2.3.1 Set Greengate or iLUMIN IP Address Connected to the ProtoNode ........................................ 9
2.3.2 Configure Device IP Address settings ...................................................................................... 9
3 Interfacing ProtoNode to Devices .................................................................................................... 10
3.1 ProtoNode FPC-N34 and FPC-N35 Showing Connection Ports .................................................. 10
3.2 BACnet MS/TP (FPC-N34): Wiring Field Port to RS-485 BMS Network ...................................... 11
3.3 LonWorks (FPC-N35): Wiring Field Port to LonWorks Network ................................................... 11
3.4 Power-Up ProtoNode.................................................................................................................... 12
4 Configure the Protonode via Web Configurator GUI ..................................................................... 13
4.1 Connect the PC to ProtoNode via the Ethernet Port .................................................................... 13
4.2 Connecting to the ProtoNode Web Configurator GUI ..................................................... 14
4.3 Set BACnet/IP and Modbus TCP/IP Address of ProtoNode to Same Switch/Router
of the Device ........................................................................................................................................ 15
4.3.1 Select Network Protocol ................................................................................................ 16
4.3.2 Configure the Device on the ProtoNode and Automatically Discover Light
Panels Connected to the Device ................................................................................................. 20
5 BACnet MS/TP and BACnet/IP: Setting Node_Offset to Assign Specific Device Instances ..... 25
6 LonWorks (FPC-N35): Commissioning ProtoNode on a lonworks Network ............................... 26
6.1 Commissioning ProtoNode FPC-N35 on a LonWorks Network ................................................... 26
6.1.1 Instructions to Download XIF File from ProtoNode FPC-N35 Using Browser ........................ 26
7 CAS BACnet Explorer for Validating ProtoNode in the Field ........................................................ 28
7.1 Downloading the CAS Explorer and Requesting an Activation Key ............................................. 28
7.2 CAS BACnet Setup....................................................................................................................... 29
7.2.1 CAS BACnet MS/TP Setup ..................................................................................................... 29
7.2.2 CAS BACnet BACnet/IP Setup ............................................................................................... 29
Appendix A. Troubleshooting .................................................................................................................. 30
Appendix A.1. Lost or Incorrect IP Address ............................................................................................ 30
Appendix A.2. Viewing Diagnostic information ........................................................................................ 31
Appendix A.3. Check Wiring and Settings............................................................................................... 32
Appendix A.4. Take Diagnostic Capture With the FieldServer Utilities ................................................... 32
Appendix A.5. BACnet: Setting Network_Number for more than one ProtoNode on Subnet ................. 35
Appendix A.6. LED Diagnostics for Communications Between ProtoNode and Devices ....................... 36
Appendix A.7. Passwords ....................................................................................................................... 36
Appendix B. Vendor Information Cooper Lighting Solutions ............................................................ 37
Appendix B.1. 3264640000 Greengate Mappings to BACnet, Modbus and LonWorks ......................... 37
Appendix B.2. 4864643204 Greengate Mappings to BACnet, Modbus and LonWorks ......................... 40
Appendix B.3. 808640000 Greengate Mappings to BACnet, Modbus and LonWorks ........................... 45
Appendix B.4. 344640003 Greengate Mappings to BACnet, Modbus and LonWorks ........................... 46
Appendix B.5. 1664643204 Greengate Mappings to BACnet, Modbus and LonWorks ......................... 49
Appendix B.6. 6464643200 Greengate Mappings to BACnet, Modbus and LonWorks ......................... 53
Appendix B.7. Scene iLUMIN Mappings to BACnet, Modbus and LonWorks ........................................ 58
Appendix B.8. Channel iLUMIN Mappings to BACnet, Modbus and LonWorks ..................................... 58
Appendix C. Reference ............................................................................................................................. 59
Appendix C.1. Specifications ................................................................................................................... 59
Appendix C.1.1. Compliance with UL Regulations ........................................................................... 59
Cooper Lighting Solutions ProtoNode Startup Guide
Page 6 of 60
Appendix D. Limited 2 Year Warranty ..................................................................................................... 60
LIST OF FIGURES
Figure 1: ProtoCessor Part Numbers ............................................................................................................ 8
Figure 2: Supported Point Count Capacity ................................................................................................... 8
Figure 3: Greengate Point Count per Device ................................................................................................ 8
Figure 4: iLUMIN Point Count per Device ..................................................................................................... 8
Figure 5: ProtoNode BACnet FPC-N34 (upper) and ProtoNode FPC-N35 (lower) .................................... 10
Figure 6: Connection from ProtoNode to RS-485 Field Network ................................................................ 11
Figure 7: RS-485 BMS Network EOL Switch .............................................................................................. 11
Figure 8: LonWorks Terminal ...................................................................................................................... 11
Figure 9: Required Current Draw for the ProtoNode .................................................................................. 12
Figure 10: Power Connections .................................................................................................................... 12
Figure 11: Select System Page .................................................................................................................. 14
Figure 12: Web Configurator GUI ............................................................................................................... 14
Figure 13: IP Address Settings via Web GUI .............................................................................................. 15
Figure 14: BMS settings Window ................................................................................................................ 16
Figure 15: BACnet/IP Settings Window ...................................................................................................... 17
Figure 16: BACnet MS/TP Settings Window............................................................................................... 18
Figure 17: Modbus TC/IP Settings Window ................................................................................................ 19
Figure 18: Modbus RTU Settings Window .................................................................................................. 19
Figure 19: Start Discovery Fields ................................................................................................................ 20
Figure 20: Discovery Bar ............................................................................................................................. 20
Figure 21: The Discovery Tree.................................................................................................................... 21
Figure 22: View & Edit Gateway Parameters .............................................................................................. 21
Figure 23: View Light Panel Parameters .................................................................................................... 22
Figure 24: View & Edit BACnet Parameters on a Lighting Panel ............................................................... 22
Figure 25: Saving Configurations Bar ......................................................................................................... 23
Figure 26: Saved Configurations ................................................................................................................ 23
Figure 27: Clear Configuration Window ...................................................................................................... 24
Figure 28: Clearing Configurations ............................................................................................................. 24
Figure 29: Web Configurator Settings Window ........................................................................................... 25
Figure 30: LonWorks Service Pin Location ................................................................................................. 26
Figure 31: Sample of Fserver.XIF File Being Generated ............................................................................ 27
Figure 32: Downloading the CAS Explorer ................................................................................................. 28
Figure 33: Requesting CAS Activation Key ................................................................................................ 28
Figure 34: Ethernet Port Location ............................................................................................................... 30
Figure 35: Error messages screen .............................................................................................................. 31
Figure 36: Ethernet Port Location ............................................................................................................... 32
Figure 37: Web Configurator showing Network Number Setting for BACnet/IP ......................................... 35
Figure 38: Diagnostic LEDs ........................................................................................................................ 36
Figure 39: Specifications ............................................................................................................................. 59
Cooper Lighting Solutions ProtoNode Startup Guide
Page 7 of 60
1 INTRODUCTION
1.1 ProtoNode Gateway
ProtoNode is an external, high performance Building Automation multi-protocol gateway that is
preconfigured to Auto-Discover any of the Cooper Lighting Solutions products (hereafter called “device”)
connected to the ProtoNode and automatically configures them for BACnet®
1
MS/TP, BACnet/IP, Modbus
TCP/IP or LonWorks®
2
.
It is not necessary to download any configuration files to support the required applications. The
ProtoNode is pre-loaded with tested Profiles/Configurations for the supported devices.
1
BACnet is a registered trademark of ASHRAE
2
LonWorks is a registered trademark of Echelon Corporation
Cooper Lighting Solutions ProtoNode Startup Guide
Page 8 of 60
2 BACNET/LONWORKS SETUP FOR PROTOCESSOR PROTONODE FPC-
N34/FPC-N35
2.1 Record Identification Data
Each ProtoNode has a unique part number located on the side or the back of the unit. This number
should be recorded, as it may be required for technical support. The numbers are as follows:
Model
Part Number
ProtoNode N34
FPC-N34-1130
ProtoNode N35
FPC-N35-1131
Figure 1: ProtoCessor Part Numbers
FPC-N34 units have the following 3 ports: RS-485 + Ethernet + RS-485.
FPC-N35 units have the following 3 ports: LonWorks + Ethernet + RS-485.
2.2 Point Count Capacity and Registers per Device
The total number of points presented by all of the devices attached to the ProtoNode cannot
exceed:
Part number
FPC-N34-1130
FPC-N35-1131
Figure 2: Supported Point Count Capacity
Greengate Devices
3264640000
4864643204
808640000
344640003
1664643204
6464643200
Figure 3: Greengate Point Count per Device
iLUMIN Devices
Scene
Channel
Figure 4: iLUMIN Point Count per Device
Cooper Lighting Solutions ProtoNode Startup Guide
Page 9 of 60
2.3 Configuring Device IP Communications
2.3.1 Set Greengate or iLUMIN IP Address Connected to the ProtoNode
The Greengate or iLUMIN device needs to be on the same IP subnet as the ProtoNode and the
configuration PC.
2.3.2 Configure Device IP Address settings
Record the following to start the setup:
o IP Address
o IP port
o Panel Address
o Number of Panels
Note: This information is required for Section 4.
Cooper Lighting Solutions ProtoNode Startup Guide
Page 10 of 60
3 INTERFACING PROTONODE TO DEVICES
3.1 ProtoNode FPC-N34 and FPC-N35 Showing Connection Ports
Figure 5: ProtoNode BACnet FPC-N34 (upper) and ProtoNode FPC-N35 (lower)
Cooper Lighting Solutions ProtoNode Startup Guide
Page 11 of 60
3.2 BACnet MS/TP (FPC-N34): Wiring Field Port to RS-485 BMS Network
Connect the BACnet MS/TP RS-485 network wires to the 3-pin RS-485 connector on
ProtoNode FPC-N34 as shown below in Figure 6.
o The RS-485 GND (Pin 3) is not typically connected.
See Section 5 for information on connecting to BACnet/IP network.
If the ProtoNode is the last device on the BACnet MS/TP, then the End-Of-Line
Termination Switch needs to be enabled. (Figure 7)
o The default setting from the factory is OFF (switch position = right side).
o To enable the EOL Termination, turn the EOL switch ON (switch position = left
side).
3.3 LonWorks (FPC-N35): Wiring Field Port to LonWorks Network
Connect ProtoNode to the field network with the LonWorks terminal using a twisted pair non-
shielded cable. LonWorks has no polarity.
BMS RS-
485 Wiring
ProtoNode
Pin #
Pin
Assignment
RS-485 +
Pin 1
RS-485 +
RS-485 -
Pin 2
RS-485 -
-
Pin 3
RS-485 GND
Figure 8: LonWorks Terminal
End-of-Line Switch
Figure 7: RS-485 BMS Network EOL Switch
G
-
+
Figure 6: Connection from ProtoNode to RS-485 Field Network
Cooper Lighting Solutions ProtoNode Startup Guide
Page 12 of 60
3.4 Power-Up ProtoNode
Apply power to ProtoNode as show below in Figure 10. Ensure that the power supply used
complies with the specifications provided in Appendix C.1.
ProtoNode accepts either 9-30VDC or 12-24 VAC on pins 4 and 5.
Frame GND should be connected.
Power Requirement for ProtoNode External Gateway
Current Draw Type
ProtoNode Family
12VDC/VAC
24VDC/VAC
30VDC
FPC N34 (Typical)
170mA
100mA
80mA
FPC N34 (Maximum)
240mA
140mA
100mA
FPC N35 (Typical)
210mA
130mA
90mA
FPC N35 (Maximum)
250mA
170mA
110mA
Note: These values are ‘nominal’ and a safety margin should be added to the power supply of the host
system. A safety margin of 25% is recommended.
Figure 9: Required Current Draw for the ProtoNode
Power to
ProtoNode
ProtoNode
Pin #
Pin
Assignment
Power In (+)
Pin 4
V +
Power In (-)
Pin 5
V -
Frame Ground
Pin 6
FRAME GND
Figure 10: Power Connections
Cooper Lighting Solutions ProtoNode Startup Guide
Page 13 of 60
4 CONFIGURE THE PROTONODE VIA WEB CONFIGURATOR GUI
4.1 Connect the PC to ProtoNode via the Ethernet Port
Connect a Cat 5 Ethernet cable (Straight through or Cross-Over) between the PC and
ProtoNode.
The Default IP Address of ProtoNode is 192.168.1.24, Subnet Mask is 255.255.255.0. If the PC
and ProtoNode are on different IP Networks, assign a static IP Address to the PC on the
192.168.1.xxx network.
For Windows XP:
Go to > >
Right-click on Local Area Connection > Properties
Highlight >
For Windows 7:
Go to > >
> >
Right-click on Local Area Connection > Properties
Highlight >
For Windows XP and Windows 7, use the following IP Address:
Click twice.
Cooper Lighting Solutions ProtoNode Startup Guide
Page 14 of 60
4.2 Connecting to the ProtoNode Web Configurator GUI
After setting the PC on the same subnet as the ProtoNode (Section 4.1), open a web browser
on the PC and enter the IP Address of the ProtoNode; the default address is 192.168.1.24.
The Configurator Web GUI will now appear when entering the device’s IP Address on the
browser.
Select the desired protocol.
The Configurator Web GUI landing page will now appear.
NOTE: If the wrong protocol was selected, click the Clear Configuration button to reset the GUI and go
back to the Select System Page.
Figure 12: Web Configurator GUI
Figure 11: Select System Page
Cooper Lighting Solutions ProtoNode Startup Guide
Page 15 of 60
4.3 Set BACnet/IP and Modbus TCP/IP Address of ProtoNode to Same
Switch/Router of the Device
From the Web GUI’s landing page, click on “Network Settings” Tab to access the IP Settings
menu. (Figure 13)
Enter new IP Address (N1 IP Address field) of the ProtoNode Ethernet port to the same
switch or router’s subnet that the device is connected.
If necessary, change the Netmask (N1 Netmask field).
Type in a new subnet mask.
If necessary, change the IP Gateway (Default Gateway field).
Type in a new IP Gateway.
Reset ProtoNode.
Connect the ProtoNode to same switch or router that the Device is connected.
Connect the PC to the same switch or router and change the IP Address of the PC to be
on the same subnet of the Device and the ProtoNode.
Record the IP Address assigned to the ProtoNode for future reference.
After setting the PC to be on the same subnet as the ProtoNode and the Device, open a web
browser on the PC and enter the new IP of the ProtoNode.
Figure 13: IP Address Settings via Web GUI
Cooper Lighting Solutions ProtoNode Startup Guide
Page 16 of 60
4.3.1 Select Network Protocol
Going back to the Discovery and Configuration tab, and press BMS Settings button to view/
Change the Building Management System (BMS) Settings.
Select BACnet/IP, BACnet MS/TP, Modbus TCP/IP, or Modbus RTU protocols.
Figure 14: BMS settings Window
Cooper Lighting Solutions ProtoNode Startup Guide
Page 17 of 60
4.3.1.1 Set Device Instance for each lighting panel attached to the Device
The Device Instance can be set independently of the site administrator.
As an example:
A Device Instance is a BACnet Node-ID which is obtained by the network administrator.
Each lighting panel connected to the Device will have its own BACnet Device Instance.
The values allowed for a BACnet Device Instance can range from 1 to 4,194,303.
With the default BACnet Device Instance value of 50,000 the Device Instances values
generated will be within the range of 50,000 plus the incremental number of lighting panels that
are connected to the ProtoNode. The first lighting panel will therefore be 50,000.
To assign a specific Device Instance (or range); change the Device instance value to assigned
value of the first lighting panel.
The Web Configurator will be displayed as the landing page.
Figure 15: BACnet/IP Settings Window
Cooper Lighting Solutions ProtoNode Startup Guide
Page 18 of 60
4.3.1.2 BACnet MS/TP (FPC-N34): Setting the MAC Address BACnet Network
Only 1 MAC address is set for ProtoNode regardless of how many light panels are connected to
ProtoNode.
Set the BACnet MS/TP MAC address of the ProtoNode to a value between 1 to 127 (MAC
Master Addresses); this is so that the BMS Front End can find the ProtoNode via BACnet auto
discovery.
Note: Never set a BACnet MS/TP MAC Address from 128 to 255. Addresses from 128 to
255 are Slave Addresses and can not be discovered by BMS Front Ends that support auto
discovery of BACnet MS/TP devices.
Enter the following details into the web configuration as per Figure 16 below:
Device Instance Enter a range between 1 and 4,194,303.
Name Enter the name of the Device.
Location Enter the location of the lighting panel.
Device Instance Offset Default of 50000 so that Device Instance begins at 50001.
Network Number Leave as default unless instructed by BMS integrator.
Baud Rate Enter a value of 9600, 19200, 38400, or 76800.
Figure 16: BACnet MS/TP Settings Window
Cooper Lighting Solutions ProtoNode Startup Guide
Page 19 of 60
4.3.1.3 Modbus TC/IP and Modbus RTU Settings
Modbus TC/IP
Modbus RTU
Figure 17: Modbus TC/IP Settings Window
Figure 18: Modbus RTU Settings Window
Cooper Lighting Solutions ProtoNode Startup Guide
Page 20 of 60
4.3.2 Configure the Device on the ProtoNode and Automatically Discover Light
Panels Connected to the Device
Click on the “Start Discovery” button to enter the port, network address, Panel Address and
Number of Panels for the Device.
o After entering the Device details, click on the “Start Discovery” button and the discovery
progress bar will display.
o The discovery of a Device may take a few minutes depending on the number of items it
contains.
Figure 19: Start Discovery Fields
Figure 20: Discovery Bar
Cooper Lighting Solutions ProtoNode Startup Guide
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60