DSPPA MP9913B Owner's manual

Type
Owner's manual
1
MP9913B
Indirect Speaker Selector
OWNERS MANUAL
Before operating, please read this manual completely.
FEATURES
l 2CH inputs, 10CH outputs.
l Hi/Low alarm level available.
l The channel will be switched to input B automatically while alarming.
l Alarm indicator and output indicator.
2
Left blank for memo
3
FRONT PANEL
REAR PANEL & CONNECTIONS
ALARM IN to be connected to fire center
l 1~10 Live Terminals of CH1~CH10 respectively
l 11~25 COM
1 2 3 4 5 6 7 8 9 10 11 12 13
14 15 ,16 ,17 18 19 ,20 21, 22 23 ,24 ,25
Power Amp. A
MP series
for BGM
Power Amp. B
MP series
for EMC
ALM OUTPUT to
Timer / Siren Device
Emergency
from FIRE center*
Input level
preset
MP9914T
To MP9906D
or MP9907C
1 2 3 4 5 6 7
1 Power switch (1 is power on and the power LED is on ) ,
2 Power indicator 5 Switching key
3 Switch indicator 6 All call button
4 Output indicator 7 All call indicator
4
OPERATION
1. Make BGM signal input from A terminal while EMC signal input from B terminal on the rear panel.
We also can make A, B together with short circuit if there is none of appropriative EMC amplifier.
2. Click down any Switching key to switch channels which you want.
3. Click All call button with its LED lit and all Switch indicators lit. In this case, all Switching keys
are no use. Click All call button again and its LED gone off, In this case, all Switching keys are
use.
4. Pin 1 ~ 10 of ALARM INport are live terminals of CH1CH10 respectively while pin 11
25 are com. +5 ~ 24V / 0V level of alarm signal is available. If ACTIVE LEVEL set at High,
positive signal is valid; while set at Low, 0V (grounded) signal is valid. Every channel will be
switched to B while alarm signal is fed to ALARM IN, and the Switch indicator will be flashing
quickly.
5. An grounded Alarm signal will be sent out fromALARM OUTwhile any alarm signal appears
onALARM INPUT.
SPECIFICATIONS
Channels 10, switchable
Input capacity
70 ~ 100 V 10 A
output capacity
70 ~ 100 V 5 A / CH
ALM 10 CHs; +5~+24 V/ 0 according to presetting
Protection
AC fuse ×1
Power Requirement
AC 220 240 V / 5060 Hz
Dimensions
485×88×375 mm
Gross weight 6.5 kg
Net weight 5.2 kg
Specifications are subject to be changed without notice.
CAUTION
When the Power switcher is off, please pull out the power cord from the socket.
Please keep the equipment out of water.
To reduce the risk of electric shock, do not remove the cover.
No user parts inside. Refer servicing to qualified service personnel
.
DSPPA Acoustic Technology Co., Ltd.
5
MP-9913B
广播分区器
使用说明
欢迎惠顾。您对本产品之选用显示了您的专业眼光。使用前请详细阅读本说明书。
性能特点
l 2 路输入(A B) 10 通道输出。
l 2 种输入告警电平选择。
l 紧急广播强插功能。
l 一目了然的告警指示和输出信号指示。
6
此页留空供用户记事。
7
前面板
后面板及连接
*ALARM INPUT 同消防中心连接
l 1~10 热端,分别对应于 CH1~CH10
l 11~25 公共端
1 2 3 4 5 6 7 8 9 10 11 12 13
14 15 ,16 ,17 18 19 ,20 21, 22 23 ,24 ,25
A 功放
MP 系列
(背景音乐)
B 功放
MP 系列
(紧急广播)
报警信号输出
去定时器/报警器
警报信号
来自消防中心
告警设定
MP9914
MP9906D
MP9907C
1 2 3 4 5 6 7
1 电源开关(按下 1 为电源接通状态且电源指示灯亮)
2 电源指示 5 分区选择键
3 分区选通指示 6 全开全关控制开关 ,
4 输出指示 7 全开全关指示
8
使用方法
1. 背景音乐信号由后面 A 紧急广播信号由 B 如无紧急广播专用功放,
可把 AB 子并接)。
2. 某一分区选择键选通分区,同 时相应的分区选通指示灯亮,即可,同
应的分区选通指示灯熄灭
3. “全开全关控制键,其相应的指示灯亮,其他十个分区控制键的指示灯时点亮,
此时其他十个分区控制键不能控制分区。再次“全开全关控制键其相应的指示
熄灭此时其他十个分区控制键才可控制分区。
4. 警报输入口ALARM IN连接)的 1125 为公共地线;第 1 号~10 号端
分别对应管理 CH1CH10 十个,输信号可以是+5V+24V 正极性信号或短路
号(输流小 3mA)。告警设定开关 High 信号有效;当该设定开关
Low 短路信号有效有告时相应通道扬声器乃动强切到 B ,且对应的分区选
通指示灯会快速闪烁
5. 警报输入口ALARM INPUT 任一子有警报信号输入时报警信号输出ALARM
OUT即有报警信号输出,用于启动处待机状态的定时器以及激发警报信号发生器
性能规格
通道数
10, 可任意选通
输入容量
70 ~ 100 V , 10A (功
输出容量
每个 70 ~ 100V , 5A (功输出)
警报信号
+5V+24V, 0V0.5V短路可预置
保护
AC 保险丝×1
电源
AC 220 240 V / 5060Hz
尺寸
485×88×375mm
毛重
6.5kg
净重
5.2kg
性能规格如有改变恕不另行
设备的电源开关状态机器并未与电源,为使用
设备时,请电源线插头拔插座
设备不能遭受水滴水溅不能将装满水花瓶品放设备
勿随机器电。必要专业书之专业人员进
DSPPA Acoustic Technology Co., Ltd.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

DSPPA MP9913B Owner's manual

Type
Owner's manual

Ask a question and I''ll find the answer in the document