Advantech SKY-7210 Startup Manual

  • Hello! I am an AI chatbot trained to assist you with the Advantech SKY-7210 Startup Manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
SKY-7210 Startup Manual 1
Before installation, ensure that the following materials have
been received:
• One SKY-7210 Hybrid network server
• One box of accessories
• Onewarrantycerticate
If any of these items are missing or damaged, please con-
tact your distributor or sales representative immediately.
Note: AcrobatReaderisrequiredtoviewanyPDFle.
Acrobat Reader can be downloaded at: www.
adobe.com/Products/acrobat/readstep2.html
(Acrobat is a trademark of Adobe)
SKY-7210
Intel® Xeon® Scalable Series Processor
2U Network Hybrid Network Server
Startup Manual
Main Board Functions
• Intel® Xeon® scalable processor supports up to 28 cores
(Skylake-SP)
• Chipset: Intel C621/C622
• BIOS: AMI 8-Mbit SPI Flash
• Memory: 24 x DDR4 ECC RDIMMs, up to 2666MHz and
up to 1563GB
• Ethernet: 3 x Intel I210-AT 10/100/1000Mbps (2 x for
Mgmt and 1 x for IPMI, and 2 x 10GB SFP+ (SKY-7210F)
• PCIe Riser:
- Max. 3 x Gen3, PCIe x16 add-on cards (by SKUs)
- Max. 6 x Gen3, PCI-E x8 add-on cards (by SKUs)
• NMC slots: 3 x NMC slots with PCIe x8 thumbs screw
type
• Storage: 12 x 3.5”/2.5” swappable HDD / SSD, 1 x M.2
Socket (22x80)
• Peripherals:
- USB2.0: 2 x USB2.0 ports on the front panel
- USB3.0: 2 x USB3.0 ports on the rear panel
- Serial: 1x D-sub console port on the rear panel
- VGA, 1 x D-sub graphic display port on the rear panel
• Dimensions (W x L x H): 438 x 730 x 88mm
• Weight: 26 - 28Kg
• Environment: Operating Non-operating
• Temperature: 0 ~ 40 -20 ~ 80
(32°F -104°F) (-4°F - 167°F)
• Humidity: 5% - 85% @40 (104°F) 5% - 95%
• Input Voltage: AC 100 ~ 240 V @ 50 ~ 60 Hz, full range
Specications Packing List
For more information on this and other Advantech products,
please visit our website at:
http://www.advantech.com.tw/support
http://www.advantech.com
For technical support and service, please visit our support
website at:
http://support.advantech.com.tw/
is manual is for the SKY-7210 series Rev. A
Part No. 2042721000
Printed in China
Edition 1
November 2018
2 SKY-7210 Startup Manual
Express Modules
• Interface:
- GE Express Module:
Supports 4-ports 10/100/1000 Base-T copper module
Supports 4-ports 10/100/1000 Base-X SFP module
- 10GE Express Module:
Supports 2/4-ports 10GbE Base-F SFP+ module
• Controller:
- GE Express Module
Intel I350-AM4 GbE controllers with 1~2 LAN bypass
segments
- 10GE Express Module:
1x Intel XL710 4-ports 10GE controller
• Dimensions (W x D): 72 x 172 mm
Figure 1: NMC-0121 4 ports RJ45 GE module
Figure 2: NMC-0108 4 ports SFP GE module
Figure 3: NMC-0806 8 ports RG45 GE module
Figure 4: NMC-1004 2 ports SFP+ GE module
SKY-7210F Redundant PSU
Front view:
Back view:
SKY-7210L Redundant PSU
Front view:
Back view:
Specications
System Overview
SKY-7210 Startup Manual 3
Installing the CPUs
SKY-7210 main board supports dual-socket INTEL®
XEON® scalable processor family with LGA3647 socket.
For details of the XEON® scalable processor assembly,
please follow Intel’s instruction to install Xeon CPU on SKY-
7210 main board.
https://www.intel.com/content/www/us/en/support/ar-
ticles/000023869/processors/intel-xeon-processors.html
Installing PCIe Riser Cards
1. Remove PCIE riser by loosening the thumbs screws
from the chassis.
2. Install the PCIex8 or PCIex16 add-on card as shown
below:
Installing NMC Express Card
1. Take out the dummy NMC bracket, then slide the NMC
card into the NMC bay on the retention rail.
Installation
4 SKY-7210 Startup Manual
Installation
Installing Fan Modules (SKY-7210F)
1. Please release 6 screws and remove fan top cover.
2. To take out fan modules by loosening thumbs screws.
Installing 3.5” HDDs
1. Please remove 3.5” HDD tray.
2. Install 3.5” or 2.5” HDD on the HDD tray with 4 screws.
SKY-7210 Startup Manual 5
Front and Rear IO
SKY-7210L SKU:
Front IO:
Rear IO:
SKY-7210F SKU:
Software tested list:
•WindowsServer2012
•RedHatEnterprise5.4and6.1
1. Read these safety instructions carefully.
2. Keep this user manual for later reference.
3. Disconnect this equipment from AC outlet before clean
ing. Do not use liquid or spray detergents for cleaning.
4. For pluggable equipment, the power outlet shall be
installed near the equipment and shall be easily acces
sible.
5. Keep this equipment away from humidity.
6. Put this equipment on a reliable surface during installa
tion. Dropping it or letting it fall could cause damage.
7. Do not leave this equipment in an environment uncon
ditioned where the storage temperature under 0°C
(32°F) or above 40°C (104°F), it may damage the
equipment.
8. The openings on the enclosure are for air convection
hence protects the equipment from overheating. DO
NOT COVER THE OPENINGS.
9. Make sure the voltage of the power source is correct
before connecting the equipment to the power outlet.
10. Place the power cord such a way that people can not
step on it. Do not place anything over the power cord.
The voltage and current rating of the cord should be
greater than the voltage and current rating marked on
the product.
11. All cautions and warnings on the equipment should be
noted.
12. If the equipment is not used for long time, disconnect it
from the power source to avoid being damaged by
transient over-voltage.
13. Never pour any liquid into ventilation openings. This
couldcausereorelectricalshock.
14. Never open the equipment. For safety reasons, the
equipmentshouldbeopenedonlybyqualiedservice
personnel.
15. If any of the following situations arises, get the equip
ment checked by service personnel:
a. The power cord or plug is damaged.
b. Liquid has penetrated into the equipment.
c. The equipment has been exposed to moisture.
d. The equipment does not work well or you cannot get
it to work according to user manual.
e. The equipment has been dropped and damaged.
f. The equipment has obvious signs of breakage.
16. CAUTION: The computer is provided with a battery-
powered real-time clock circuit. There is a danger of
explosion if bat¬tery is incorrectly replaced. Replace
only with same or equivalent type recommended by the
manufacture. Discard used batteries according to the
manufacturer’s instructions.
17. The computer is provided with CD drives that comply
with appropriate safety standards, including IEC 60825.
Software Installation
Safety Instructions
6 SKY-7210 Startup Manual
18. This device complies with Part 15 of the FCC rules.
Operation is subject to the following two conditions: (1)
this device may not cause harmful interference, and (2)
this device must accept any interference received,
including interference that may cause undesired opera
tion.
19. CAUTION: Always completely disconnect the power
cord from your chassis whenever you work with the
hardware. Do not make connections while the power
is on. Sensitive electronic components can be dam
aged by sudden power surges.
20. CAUTION: Always ground yourself to remove any static
charge before touching the motherboard, backplane, or
add-on cards. Modern electronic devices are very
sensitive to static electric charges. As a safety precau
tion, use a grounding wrist strap at all times. Place all
electronic components on a static-dissipative surface
or in a static-shielded bag when they are not in the
chassis.
21. CAUTION:Anyunveriedcomponentcouldcauseun
expected damage. To ensure the correct installation,
please always use the components (ex. screws) pro
vided with the accessory box.
22. Caution text concerning lithium batteries:
ADVARSEL!
Lithiumbatteri - Eksplosionsfare ved fejlagtig
håndtering.
Udskiftning må kun ske med batteri af samme
fabrikat og type.
Levér det brugte batteri tilbage tilleverandøren.
23. “Rack Mount Instructions - The following or similar
rack-mount instructions are included with the installa
tion instructions:
A) Elevated Operating Ambient - If installed in a closed or
multi-unit rack assembly, the operating ambient
temperature of the rack environment may be greater
than room ambient. Therefore, consideration should be
given to installing the equipment in an environment
compatible with the maximum ambient temperature
(Tma)speciedbythemanufacturer.
B) Reduced Air Flow - Installation of the equipment in a
rackshouldbesuchthattheamountofairowrequired
for safe operation of the equipment is not compro
mised.
C) Mechanical Loading - Mounting of the equipment in
the rack should be such that a hazardous condition is
not achieved due to uneven mechanical loading.
D) Circuit Overloading - Consideration should be given
to the connection of the equipment to the supply circuit
Safety Instructions
and the effect that overloading of the circuits might
have on overcurrent protection and supply wiring.
Appropriate consideration of equipment nameplate rat
ings should be used when addressing this concern.
E) Reliable Earthing - Reliable earthing of rack-mounted
equipment should be maintained. Particular attention
should be given to supply connections other than direct
connections to the branch circuit (e.g. use of power
strips).”
/