ASRock Rack 3U10G-F/C621 User manual

Category
Computer cases
Type
User manual

ASRock Rack 3U10G-F/C621 is a 3U rackmount server system with excellent performance and robust design, providing high reliability and flexibility for various applications. It supports the installation of up to 10 PCIe 3.0 x16 GPGPU cards, making it an ideal choice for high-performance computing, artificial intelligence, and deep learning applications. With redundant power supplies and hot-swappable system components, the 3U10G-F/C621 ensures maximum uptime and serviceability. It also features a variety of storage options, including 6x 2.

ASRock Rack 3U10G-F/C621 is a 3U rackmount server system with excellent performance and robust design, providing high reliability and flexibility for various applications. It supports the installation of up to 10 PCIe 3.0 x16 GPGPU cards, making it an ideal choice for high-performance computing, artificial intelligence, and deep learning applications. With redundant power supplies and hot-swappable system components, the 3U10G-F/C621 ensures maximum uptime and serviceability. It also features a variety of storage options, including 6x 2.

3U10G-F
3U10G-F/C621
3U10G-F/C621/MN
User Manual
Version 1.0
Published June 2019
Copyright©2019 ASRock Rack INC. All rights reserved.
Version 1.0
Published June 2019
Copyright©2019 ASRock Rack Inc. All rights reserved.
Copyright Notice:
No part of this documentation may be reproduced, transcribed, transmitted, or
translated in any language, in any form or by any means, except duplication of
documentation by the purchaser for backup purpose, without written consent of
ASRock Rack Inc.
Products and corporate names appearing in this documentation may or may not
be registered trademarks or copyrights of their respective companies, and are used
only for identication or explanation and to the owners’ benet, without intent to
infringe.
Disclaimer:
Specications and information contained in this documentation are furnished
for informational use only and subject to change without notice, and should not
be constructed as a commitment by ASRock Rack. ASRock Rack assumes no
responsibility for any errors or omissions that may appear in this documentation.
With respect to the contents of this documentation, ASRock Rack does not provide
warranty of any kind, either expressed or implied, including but not limited to
the implied warranties or conditions of merchantability or tness for a particular
purpose.
In no event shall ASRock Rack, its directors, ocers, employees, or agents be liable
for any indirect, special, incidental, or consequential damages (including damages
for loss of prots, loss of business, loss of data, interruption of business and the
like), even if ASRock Rack has been advised of the possibility of such damages
arising from any defect or error in the documentation or product.
is device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that
may cause undesired operation.
CALIFORNIA, USA ONLY
e Lithium battery adopted on this motherboard contains Perchlorate, a toxic substance
controlled in Perchlorate Best Management Practices (BMP) regulations passed by the
California Legislature. When you discard the Lithium battery in California, USA, please
follow the related regulations in advance.
“Perchlorate Material-special handling may apply, see www.dtsc.ca.gov/hazardouswaste/
perchlorate
ASRock Racks Website: www.ASRockRack.com
Setting up the Server in a Restricted Access Location
• Access can only be gained by service persons or by users who have been instructed
about the reasons for the restrictions applied to the location and about any precautions
that shall be taken.
• Access is through the use of a tool or lock and key, or other means of security, and is
controlled by the authority responsible for the location.
• Leave enough clearance (25 inches in the front and 30 inches in the back of the rack) to
allow the front door to be opened completely and to allow for sucient airow.
• is product is for installation merely in a Restricted Access Location.
• is product is not suitable for use with visual display work place devices according to §2
of the the German Ordinance for Work with Visual Display Units.
Replaceable Batteries
CAUTION
RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE.
DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS
Warning
When removal of the chassis lid required for servicing:
- Turn o power and unplug any power cords/cables, and
- Reinstall the chassis lid before restoring power.
Important Safety Instructions
Pay close attention to the following safety instructions before performing any of
the operation. Basic safety precautions should be followed to protect yourself from
harm and the product from damage:
• Operation of the product should be carried out by suitably trained, qualied, and
certied personnel only to avoid risk of injury from electrical shock or energy hazard.
• Disconnect the power cord from the wall outlet when installing or removing main
system components, such as the motherboard and power supply unit.
• Place the system on a stable and at surface.
• Use extreme caution when working with high-voltage components.
• When handling parts, use a grounded wrist strap designed to prevent static discharge.
• Keep the area around the system clean and clutter-free.
• Keep all components and printed circuit boards (PCBs) in their antistatic bags when
not in use.
• Handle a board by its edges only; do not touch its components, peripheral chips,
memory modules or contacts.
Contents
Chapter 1 Introduction 1
1.1 Shipping Box Contents 2
1.2 Specications 4
Chapter 2 Server System Overview 5
2.1 System Components 5
2.2 Internal Features 6
2.3 System Front Panel 8
2.4 System Rear Panel 11
2.5 Front Control Panel Buttons and LEDs 12
2.6 PSU LED 14
2.7 Drive Tray LEDs 14
2.8 Fan Failed LED 15
Chapter 3 Hardware Installation and Maintenance 16
3.1 Server Top Cover 17
3.2 Hard Drive 21
3.3 Power Supply 23
3.4 System Fan 25
3.5 GPU or MIC Card 26
3.6 Motherboard Tray 31
3.7 Add-on Card & Mezzanine Card (3U10G-F/C621 only) 34
3.7.1 Installing an Add-on Card 34
3.7.2 Installing a Mezzanine Adapter Card (4U10G_SL2M) 37
3.8 Add-on Card (Low Prole) & Mezzanine Card (3U10G-F only) 41
3.9 Air Duct 44
Appendix 46
Installing the Server in a Rack 46
3U10G-F / 3U10G-F/C621 / 3U10G-F/C621/MN
PB 1
English
Chapter 1 Introduction
ank you for purchasing 3U10G-F/C621 / 3U10G-F/C621/MN, a reliable barebone
system produced under ASRock Rack’s consistently stringent quality control. It
delivers excellent performance with robust design conforming to ASRock Rack’s
commitment to quality and endurance.
Because the hardware specications might be updated, the content of this documentation
will be subject to change without notice. In case any modications of this documentation
occur, the updated version will be available on ASRock Rack’s website without further
notice. If you require technical support related to this product, please visit our website for
specic information about the model you are using.
ASRock Rack’s Website: www.ASRockRack.com
e illustrations shown in this manual are examples only, the actual system may dier
slightly .
2 3
English
1.1 Shipping Box Contents
Item
Quantity
3U10G-F/C621
3U10G-F 3U10G-F/C621/MN
3U10G-F Series Barebone (3U form factor) 1 1
System Boards (MB) 1 1
Power Supply Units 4 3
System Fans 9 9
HDD Backplane (BPB) 1 1
Front Panel Board 1 1
Power Distribution Boards (PDB) 1 1
Switch Board (SWB) 1 1
Le Interposer Board (LIPB) 1 1
Right Interposer Board (RIPB) 1 1
Mezzanine Adapter Card (4U10G_SL2M) 2 2
Riser Card (4U10G_SL2P) 2 2
Goldnger Board (4U10G-F_FB_GF) 5 5
Fan Board (4U10G-F_FB) 5 5
PMBus Cable (L=390mm) 1 0
SLIMLINE Cable (L=200mm) 4 0
SLIMLINE PWR Cable 1 0
Power ATX 24 PIN Cable (L=340mm) 1 1
Power ATX 8 PIN Cable (L=350mm) 1 1
Power ATX 8 PIN Cable (L=550mm) 1 1
BPB Power Cable (L=140mm) 1 1
MiniSAS HD to MiniSAS Cable (L=220mm) 1 1
MiniSAS HD(R/A) to SGPIO+2*SATA Cable
(L=220mm) 1 1
MNG Cable (L=550mm) 1 1
USB Cable (L=400mm) 1 1
Front Control Cable (L=350mm) 1 1
Fan Cable (L=650mm) 2 2
Fan Cable (L=900mm) 3 3
GPU Power Cable (L=120mm) 10 10
3U10G-F / 3U10G-F/C621 / 3U10G-F/C621/MN
2 3
English
If any items are missing or appear damaged, contact your authorized dealer.
Item
Quantity
3U10G-F/C621
3U10G-F 3U10G-F/C621/MN
Accessory Box 1 1
Support CD 1 1
Quick Installation Guide 1 1
4U Top Cover 1 1
Rail Assembly Kit 1 1
4 5
English
1.2 Specications
3U10G-F / 3U10G-F/C621 / 3U10G-F/C621/MN
System Physical Status
Form Factor 3U Rackmount
Dimension
(D x W x H)
807mm x 430mm x 170.3mm (L/W/H, w/o ear)
Support MB Size 12" x 10.9"
Front Panel
Buttons • Power On/Standby button
• ID button
• System reset button
• NMI button
LEDs • Power LED
• Identication LED
• Hard drive activity LED
• 4 x Network activity LEDs
• System event LED
I/O Ports 2 x USB 2.0 ports
Drive Bay
External 6 x 2.5" SATA HDD (6Gb/s) or 6 x SAS HDD* (12Gb/s)
*A PCIE RAID card is required for SAS support.
(3U10G-F/C621: support SAS/NVME*2)
System Cooling
Fan 9 x 8038 Chassis FAN(Hot swap) : 4 Center + 5 Rear
Power Supply
Capacity 3U10G-F/C621:
4 (3+1), Redundant
3U10G-F/C621/MN:
3 (2+1), Redundant
Output Watts 1600W @ 200Vac~240Vac
System Switch Board
Switch IC PLX 8796
GPGPU Card
GPGPU Watts Max 300w /per card
Support GPGPU 10 x GPGPU cards
Please refer to the user manual of the motherboard you use for detailed information about
motherboard components and features.
3U10G-F / 3U10G-F/C621 / 3U10G-F/C621/MN
4 5
English
Chapter 2 Server System Overview
is chapter provides diagrams showing the location of important components of
the server system.
2.1 System Components
6 x 2.5” Hot-Swap HDD Trays
Server Board
Power Supply Units
5 x Hot-Swap System Fans
10 x GPGPU Card Slots
Front Controls and Indicators
4 x Hot-Swap System Fans
6 7
English
2.2 Internal Features
11 12 13
15 16 17 18
5
1
7
19
9
8
20 21 22 23
25 26 27
10
2 3 4
29
28
6
24
14
3U10G-F / 3U10G-F/C621 / 3U10G-F/C621/MN
6 7
English
No. From
1Front Control Panel
2Power Supply Unit (PSU) 4
3Power Supply Unit (PSU) 3
4Power Supply Unit (PSU) 2
5Power Supply Unit (PSU) 1 (not supported for 3U10G-F/C621/MN)
6Serverboard
76 x 2.5" SATA HDDs (Hot-swapable)
8HDD Backplane Board (BPB)
9Power Distribution Board (PDB)
10 System Fan 1
11 System Fan 2
12 System Fan 3
13 System Fan 4
14 Switch Board (SWB)
15 GPGPU/MIC Card Slot 1
16 GPGPU/MIC Card Slot 2
17 GPGPU/MIC Card Slot 3
18 GPGPU/MIC Card Slot 4
19 GPGPU/MIC Card Slot 5
20 GPGPU/MIC Card Slot 6
21 GPGPU/MIC Card Slot 7
22 GPGPU/MIC Card Slot 8
23 GPGPU/MIC Card Slot 9
24 GPGPU/MIC Card Slot 10
25 Rear System Fan 1
26 Rear System Fan 2
27 Rear System Fan 3
28 Rear System Fan 4
29 Rear System Fan 5
8 9
English
2.3 System Front Panel
3U10G-F/C621
33
HDD0
HDD1
HDD2
HDD3
HDD5 NVMe SLOT2 SLIMLINE x16 SLOT1 SLIMLINE x8
HDD4 NVMe
5
4
12
WARNING! Do NOT open the tray if the server
is not powered down or while it is still running.
!
Redundant PSU 3+1: Only one PSU is allowed to be removed while the server is running.
7
6
3U10G-F/C621/MN
HDD0
HDD1
HDD2
HDD3
HDD5
HDD4
Redundant PSU 2+1: Only one PSU is allowed to be removed while
the server is running.
5
4
12
WARNING! Do NOT open the tray if the server
is not powered down or while it is still running.
!
6
7
3U10G-F / 3U10G-F/C621 / 3U10G-F/C621/MN
8 9
English
No. Description
13U10G-F/C621:
6 x 2.5" HDD trays (Slot 4 and Slot 5 support NVME)
3U10G-F/C621/MN:
6 x 2.5" HDD trays
2 I/O Shield (depends on the specication of the server board)
33U10G-F/C621:
2 x Add-on Card / Mezzanine Card Slots (with the riser-card assembly)
3U10G-F/C621/MN:
N/A
4Motherboard Tray Handle*
*WARNING! Please do NOT open the tray if the server is not powered down or while it is
still running.
5Rea r Vent
6 Control Panel
73U10G-F/C621:
4 x Power Supply Units (Redundant PSU 3+1)
*Server requires 3 working PSUs, with 1 redundant PSU. You must have at least three ac-
tive supplies, installed, functioning and connected to AC. Only one of the PSUs is allowed
to be removed while the server is running.
3U10G-F/C621/MN:
3 x Power Supply Units (Redundant PSU 2+1)
*Server requires 2 working PSUs, with 1 redundant PSU. You must have at least three ac-
tive supplies, installed, functioning and connected to AC. Only one of the PSUs is allowed
to be removed while the server is running.
10 11
English
3U10G-F
2
13567
WARNING! Do NOT open the tray if the server
is not powered down or while it is still running.
!
Redundant PSU 3+1: Only one PSU is allowed to be removed while the server is running.
43 4
No. Description
1 6 x 2.5" HDD trays
2 I/O Shield (depends on the specication of the server board)
3 Mezzanine Card Support for 1GbE x 2 or 10GbE x2
4 Low Prole PCI Express Slot (for the riser card)
5Motherboard Tray Handle*
*WARNING! Please do NOT open the tray if the server is not powered down or while it is
still running.
6Rea r Vent
7 4 x Power Supply Units (Redundant PSU 3+1)
*Server requires 3 working PSUs, with 1 redundant PSU. You must have at least three ac-
tive supplies, installed, functioning and connected to AC. Only one of the PSUs is allowed
to be removed while the server is running.
3U10G-F / 3U10G-F/C621 / 3U10G-F/C621/MN
10 11
English
2.4 System Rear Panel
35
4
12
No. Description
1 Rear System Fan 1
2 Rear System Fan 2
3 Rear System Fan 3
4 Rear System Fan 4
5 Rear System Fan 5
12 13
English
2.5 Front Control Panel Buttons and LEDs
Front Control Panel
2
7
3
6
5
4
UID
NMI RST
L1 L2
L3 L4
PWR
BTN
!
1
No. Description
1 Power Button and LED
2 UID Button and LED*
3 LAN1, LAN2, LAN3, LAN4 Activity LEDs*
4 HDD Activity LED
5 System Event LED*
6 NMI (Nonmaskable Interrupt) Button*
7 System Reset Button
*Please be noted that the functions are supported depending on the type of the server board.
Power Button
Press the power switch button to toggle the system power on and standby/sleep modes.
To remove all power from the system completely, disconnect the power cord from the
server.
ID Button
Press the ID button to toggle the front panel ID LED and the baseboard ID LED on and
o. You are able to locate the server you’re working on from behind a rack of servers.
3U10G-F / 3U10G-F/C621 / 3U10G-F/C621/MN
12 13
English
NMI (Nonmaskable Interrupt) Button
Press the NMI button with a paper clip or pin to generate a nonmaskable interrupt and to
put the server in a halt state for examination.
System Reset Button
When the system is completely unresponsive, press the system reset button to reboot the
server without shutting it o and initialize the system.
Status LED Denitions
Power LED
Status Description
Green Power on
O Power o
ID LED
Status Description
Blue System identication is active.
O System identication is disabled.
LAN1, LAN2, LAN3, LAN4 LEDs
Status Description
Green Link between system and network or no access
Blinking Green Network access
HDD Activity LED
Status Description
Blinking Green HDD access
O HDD idle
System Event LED
Status Description
O Running or normal operation
Red At least one sensor has critical alert
14 15
English
2.6 PSU LED
PSU LED
PSU Status LED
Status Description
Green Normal work; output ON and OK
Amber Module fault/protection in operating mode
(failure, OCP, OVP, Fan Fail, OTP, UVP)
AC cord unplugged
Amber blinking at 0.5Hz Warning (high temp, high power, high current, slow fan)
Green blinking at 0.5Hz AC Present Only 12VSB on (PS o) or PS in Smart
Redundant state
2.7 Drive Tray LEDs
1
2
No. Description
1 HDD Power LED
2 HDD Activity LED
Status LED Denitions
HDD Power LED
Status Description
Blue HDD powered-on
O No power to HDD
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58

ASRock Rack 3U10G-F/C621 User manual

Category
Computer cases
Type
User manual

ASRock Rack 3U10G-F/C621 is a 3U rackmount server system with excellent performance and robust design, providing high reliability and flexibility for various applications. It supports the installation of up to 10 PCIe 3.0 x16 GPGPU cards, making it an ideal choice for high-performance computing, artificial intelligence, and deep learning applications. With redundant power supplies and hot-swappable system components, the 3U10G-F/C621 ensures maximum uptime and serviceability. It also features a variety of storage options, including 6x 2.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI