Altronix NetWay1DWP Installation guide

Type
Installation guide
NetWay1DWP/NetWay1DWPH/NetWay1DWPM/NetWay1DWPMH - 1 -
NetWay1DWP - Outdoor Single Port Hi-PoE Injector
NetWay1DWPM - Outdoor Managed Single Port Hi-PoE Injector
Installation Guide
Rev. 112713
I.T.E. 43KC
Overview:
Altronix NetWay1DWP Outdoor Single Port Midspan Injector provides Hi-PoE (60W) power and passes data for PoE
compliant cameras/edge devices. Cameras/edge devices may be located up to 100m from the unit.
NetWay1DWPM includes built-in IP management which facilitates remote device reset/control and status monitoring.
Features:
Installation Instructions:
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and
authorities having jurisdiction. Wiring should be UL Listed and/or Recognized wire suitable for the application.
1. Remove circuit board from enclosure prior to drilling NetWay1DWP and NetWay1DWPM (do not discard hardware).
Note: Take care to assure that hardware will not interfere with components of the circuit board.
2. NetWay1DWP and NetWay1DWPM: Mark and drill desired inlets on the enclosure to facilitate wiring
(Fig. 2, pg. 2). Maximum UL Listed NEMA type 4X rated fittings to be used is 1/2”, follow manufacturer’s
specifications for the appropriate size opening.
Note: Inlets for conduit fittings should only be made on the bottom of the enclosure.
UL Listed NEMA type 4X rated conduit connector/hubs shall be used for the appropriate size inlets.
NetWay1DWPH and NetWay1DWPMH are pre-drilled with three (3) pre-drilled inlet holes for wiring.
3. Clean out the inside of enclosure before remounting circuit board.
4. Switch circuit breaker to the OFF position.
5. Connect AC power from a UL approved circuit breaker to the terminals marked [L] and [N],
connect ground to the terminal marked [G] (refer to Fig. 1 on right).
6. Mounting NEMA 4X rated enclosure:
Wall mount: Mount unit in desired location. Mark and drill holes to line up with the top and
bottom holes of the enclosure flange. Secure enclosure with appropriate fasteners (e. g. screws
and anchors; bolts and locking nuts, etc.) which are compatible with mounting surface and are
of sufficient length/construction to ensure a secure mount (Fig. 8, pg. 6).
Pole Mount: (refer to page 6).
Note: All inlets for conduit fittings should be on the bottom of the enclosure.
7. Mount circuit board in enclosure with hardware.
Agency Listings:
UL/CUL Listed for Information Technology
Equipment (UL 60950-1), Information Technology
Equipment to be installed Outdoors (UL 60950-22).
CE approved.
Input:
115VAC, 60Hz, 1.2A or
230VAC, 50/60Hz, 0.75A.
Power Output:
Maximum power: Hi-PoE (60W). Power product
using all 4 pairs for 60W.
IEEE 802.3at (30W) and IEEE 802.3af (15W) compliant.
Integral surge protection.
Ethernet:
Connectivity: RJ45, auto-crossover.
Wire type: 4-pair Cat-5 or better structured cable.
Distance: up to 100m.
• Speed: 10/100/1000Mbps, half/full duplex,
auto negotiation.
LEDs:
LED1: PoE active on Spare. LED2: PoE active on Signal.
Environmental:
Operating Temperature:
30W: -30ºC to 70ºC (-22ºF to 158ºF).
60W: -30ºC to 55ºC (-22ºF to 131ºF).
Storage Temperature: -30ºC to 85ºC (-22ºF to 185ºF).
Humidity: 20 to 85%, non-condensing.
Applications:
Provides PoE/PoE+ and Hi-PoE for cameras/devices.
Mechanical:
NEMA 4X, IP66 Rated enclosure for outdoor use.
Dimensions (H x W x D approx.):
9.5” x 7.32” x 4.92” (241.3mm x 185.9mm x 125mm).
Models:
NetWay1DWP: Outdoor Single Port Hi-PoE Injector.
NetWay1DWPH: Outdoor Single Port Hi-PoE Injector,
enclosure with three (3) 5/8” wiring inlets, includes NEMA
rated glands.
NetWay1DWPM: Outdoor Managed Single Port Hi-PoE
Injector.
NetWay1DWPMH: Outdoor Managed Single Port
Hi-PoE Injector, enclosure with three (3) 5/8” wiring
inlets, includes NEMA rated glands.
®
LGN
115VAC/230VAC
Input
Line Neutral
Ground
- 2 - NetWay1DWP/NetWay1DWPH/NetWay1DWPM/NetWay1DWPMH
8. To facilitate wire entry utilize weather tight NEMA rated connectors (supplied), bushings and cable.
9. Connect structured cable from UL Listed ethernet switch or video server to RJ45 jack marked [IN] on
NetWay1DWP/NetWay1DWPH/NetWay1DWPM/NetWay1DWPMH (Fig. 1, pg. 2).
10. Connect structured cable from camera/device to RJ45 jack marked [OUT] on NetWay1DWP/NetWay1DWPH/
NetWay1DWPM/NetWay1DWPMH (Fig. 1, pg. 2).
11. Switch circuit breaker to the ON position.
Technical Specifications:
Parameter Description
Number of Ports One (1) Hi-PoE (60W) or IEEE 802.3at (30W) and IEEE 802.3af (15W) compliant.
Input power requirements 115VAC, 60Hz, 1.2A or 230VAC, 50/60Hz, 0.75A.
Environmental Conditions
Operating Ambient Temperature: 30W = 70ºC (158ºF). 60W = 55ºC (131ºF).
Relative humidity: 20 to 85%, non-condensing.
Storage Temperature: -30ºC to 85ºC (-22ºF to 185ºF).
Operating Altitude: -1,000 to 6,561.679 ft. (-304.8 to 2,000m).
Regulatory Compliance
UL/CUL Listed for Information Technology Equipment (UL 60950-1)
Information Technology Equipment to be installed Outdoors (UL 60950-22). CE approved.
Weights (approx.) Product: 3.7 lbs. (1.68 kg), Shipping: 5 lbs. (2.27 kg)
Fig. 2 - Bottom of enclosure
Typical Application:
Fig. 3
Ethernet Switch
Video
Monitor
NVR/Network Server
OUT IN
CAT-5 or
Higher
100m
CAT-5 or
Higher
100m
Camera/
Device
115VAC/230VAC
Input
LGN
Line Neutral
Ground
0.875”
22.22mm
4.25”
107.95mm
2.4375”
61.91mm
1.125”
28.575mm
1.125”
28.575mm
1.25”
31.75mm
Suggested area
for Inlets
NetWay1DWP/NetWay1DWPH/NetWay1DWPM/NetWay1DWPMH - 3 -
NetWay1DWPM/H User Interface and Programming:
Note: A constant PC connection is not required for proper operations and is used as a local programming/monitoring tool only.
Please note that all interconnecting equipment shall be UL Listed.
Step 1. Set Local Area Connection of your laptop to Static IP mode.
Static IP address of the laptop must be assigned to the same network as the current IP address of NetWay1DWPM/H.
The default IP address of NetWay1DWPM/H units is 192.168.168.168.
This manual assumes that it has not been changed by user.
For Windows XP:
a. Open Network Connections by clicking Start button, then clicking Settings, then clicking Network Connections.
b. Right-click the Local Area Connection. Click Properties. Administrator permission required.
If you are prompted for an administrator password or confirmation, type the password or provide confirmation.
c. Double click Internet Protocol (TCP/IP) menu item.
d. Choose the Use the following IP address option.
e. Set the IP address to 192.168.168.15 (or another valid IP address on the same network).
f. Click OK. Close all windows.
For Windows 7:
a. Open Network Connections by clicking the Start button, clicking Control Panel, clicking Network and Internet,
clicking Network and Sharing Center, and then clicking Change Adapter Settings.
b. Right click the Local Area Connection icon, and then click Properties. Administrator permission required.
If you are prompted for an administrator password or confirmation, type the password or provide confirmation.
c. Click the Networking tab. Under this connection uses the following items, click either Internet Protocol Version 4
(TCP/IPv4) and then click Properties.
d. Choose the Use the following IP address option.
e. Set the IP address to 192.168.168.15 (or another valid IP address on the same network).
f. Click OK. Close all windows.
Step 2. Connect a laptop or PC to the Ethernet port of your NetWay1DWPM/H unit.
The NetWay1DWPM/H unit should be powered up at this moment.
Step 3. Open a browser window (it is necessary to update your browser software to the latest version so that the pages
display and function correctly).
Step 4. Enter the NetWay1DWPM/H IP address (the default IP address is 192.168.168.168) into the address bar.
Status page will be displayed.
Step 5. Click Setup link. Setup page will be displayed. You may now program your NetWay1DWPM/H.
All NetWay1DWPM/H units come factory set:
a. Ports - Enabled.
b. Ports - PoE shutdown Disabled.
c. Power Allocation Mode - Class restricted.
Configuring NetWay1DWPM/H for Network Connection:
Since every Network Configuration is different, please check with your Network Administrator to see if your
NetWay1DWPM/H should use static IP addresses, or DHCP assigned IP addresses and/an Inbound Port assignment prior
to setting up network connection.
1. Click Network Settings link.
You will be prompted for an
administrative password,
type and submit the
password.
User name: admin
Password: admin
Management Interface
Version 0.88
Status
NetWay Setup
x
x
Setup Network Settings
192.168.168.168
®
Status
Date/Time:
Maximum Power Draw (Watts) Actual Power Draw Watts Port Status
0 0 Enabled
Data Pair
Authentication Required
The server http://192.168.168.168:80 requires a username and
password. The server says: Altronix webpage.
User Name:
Password:
Log In Cancel
x
- 4 - NetWay1DWP/NetWay1DWPH/NetWay1DWPM/NetWay1DWPMH
2. Network Setup page will be displayed. You may now configure your NetWay1DWPM/H for network connection.
Fig. 5 -
NETWORK SETTING MENU.
This menu is for configuring the
NetWay1DWPM/H units for a
network connection.
Network Type:
Static IP
User can set a fixed IP for network connection.
DHCP
DHCP server in LAN will automatically an assign IP configuration for the network connection.
IP
This field shows the NetWay1DWPM/H current IP Address. A static IP address must be set manually.
If DHCP this value will be assigned automatically.
Subnet Mask
This field shows the subnet mask for your network so the NetWay1DWPM/H will be recognized within
the network. If DHCP is selected, this value will be assigned automatically.
Inbound Port
Port number for HTTP/WEB communication.
Host Name
Name of the NetWay1DWPM/H device on the LAN
Additional Information:
1. If using DHCP, all settings will be detected automatically.
While DHCP is a useful tool for determining the network settings, if you set up your NetWay1DWPM/H in this
manner, its IP address may change at different times for different reasons, particularly after a power failure.
If the IP address of the NetWay1DWPM/H changes, you may have difficulties accessing your NetWay1DWPM/H
locally and/or remotely.
It is strongly recommended that you connect via host name when units configured as DHCP.
Please do not set the DHCP address issued to the NetWay1DWPM/H by the router as its static IP address unless you
take specific steps that program your router to prevent such address conflicts.
2. If using a Static IP (recommended), you will need to input the information manually. In order for DDNS to work,
you must enter valid data compatible with your network for all of the network setting fields: IP address,
Subnet Mask, Gateway and Inbound Port.
3. If you are connecting through a router, make sure that you have ‘opened up’ all the required network ports in the port
forwarding section of your router’s setup options. That is, you have directed the router to send any incoming traffic
using those IP ports to the LAN IP address of the NetWay1DWPM/H. Useful information about router port
forwarding can be found at www.portforward.com. Different routers may use different terms for port forwarding
function. For instance, D-Link calls it virtual server, Netopia calls it pinholes.
The default port for NetWay1DWPM/H is: 80
Note: Port 80 is the default port used for web browsing. Because of this, in order to prevent the average user from
hosting a web server, most ISPs BLOCK traffic using port 80 from reaching the average site. If you only plan to
Management Interface
Version 0.88
Status
NetWay Network Settings
x
x
Setup Network Settings
192.168.168.168/networksetup.htm
®
NetWay1DWPM
Network Settings
Site ID: Altronix Site ID
Friday, May 16 2014 [11:11 am]
Reboot Server
Submit Network Settings
Submit Trap Receiver IP Settings
Submit Syslog Settings
Static
Network Settings: Trap Receiver Settings:
Syslog Settings:
192.168.168.168
255.255.255.0
192.168.168.100
80
10.10.10.53
10.10.10.76
10.10.10.12
10.10.10.13
10.10.10.14
10.10.10.15
100
IP Address Method:
IP Address:
Subnet Mask:
Gateway:
Inbound Port:
Syslog Server IP:
Syslog Server Port:
Trap Receiver Address 1:
Trap Receiver Address 2:
Trap Receiver Address 3:
Trap Receiver Address 4:
Trap Receiver Address 5:
NetWay1DWP/NetWay1DWPH/NetWay1DWPM/NetWay1DWPMH - 5 -
monitor your NetWay1DWPM/H on a LAN, you can use port 80 and you don’t have to concern yourself with routers.
However, if you desire remote access to your NetWay1DWPM/H, you MUST select functional ports and set up the
port forwarding in your router. Other ports, such as 8080 and 8000, are sometimes blocked by ISPs as well.
What port(s) should be used? There are 65,535 valid IP ports to choose from.
These are broken down into three groups:
• Well Known Ports 0 through 1023.
• Registered Ports 1024 through 49151.
• Dynamic and/or Private Ports 49152 through 65535.
So, rather than encounter a port conflict by choosing a port commonly used for another purpose (like port 25 for SMTP
mail or port 448 for secure sockets), choose an ‘unusual’ port number. For example, add 50,000 to your house number:
50123 is less likely to lead to a port conflict. For a list of the known and registered ports,
see http://www.iana.org/assignments/port-numbers.
Fig. 6 - Setup
Authenication Required pop-up
box will appear the default
User name: admin
Password: admin
Fig. 7 - Setup
You may now configure the
NetWay1DWPM/H unit settings
and Change the Username
and Password (located on the
bottom of Setup screen).
Management Interface
Version 0.88
Status
NetWay Setup
x
x
Setup Network Settings
NetWay1DWPM
Setup
192.168.168.168/setup.htm
Update Site ID
Site ID:
Altronix Site ID
Update Sync Date/Time with computer
Date/Time:
November
Security Settings:
Username: admin Password: • • •
12 10 23 53 pm
][
2014
Disable Port
Save Username and Password
Port Status:
Spare Pair
EnabledDisable Port
Port Status:
Data Pair
Enabled
Change Username and Password
®
Management Interface
Version 0.88
Status
NetWay Setup
x
x
Setup Network Settings
NetWay1DWPM
Setup
192.168.168.168/setup.htm
Update Site ID
Site ID:
Altronix Site ID
Update Sync Date/Time with computer
Date/Time:
November
Security Settings:
Username: admin Password: • • •
12 10 23 53 pm
][
2014
Disable Port
Save Username and Password
Port Status:
Spare Pair
EnabledDisable Port
Port Status:
Data Pair
Enabled
Change Username and Password
®
- 6 - NetWay1DWP/NetWay1DWPH/NetWay1DWPM/NetWay1DWPMH
Wall Mount Installation
1. Place unit at desired location and secure with mounting
screws (not included) (Fig. 8, pg. 6).
Fig. 8
Pole Mounting Using Optional Pole Mount Kit PMK1 (not included):
This installation should be made by qualified service personnel. This product contains no serviceable parts. PMK1 is in-
tended for use with Altronix outdoor rated power supplies or accessories housed in WP1, WP2, WP3 and WP4 enclosures.
Brackets are designed for use with the Wormgear Quick Release Straps (two included).
1. Thread one (1) wormgear quick release strap through the slots on the back of a mounting bracket (Fig. 9, pg. 6).
2. Once the desired height of the top Pole Mount bracket is achieved, tighten the straps down by sliding open end
of the strap through the locking mechanism on the strap, then tighten the screw with
flat head screwdriver or 5/16” hex socket driver (Fig. 10, pg. 6).
3. Attach the bottom bracket to the enclosure by inserting bolts through the
flange of the enclosure and into the bracket, tightening bolts with a
7/16” hex socket (Fig. 12, pg. 6).
4. Thread the second wormgear quick release strap through the slots on the
back of the bottom mounting bracket (Fig. 12, pg. 6).
5. Mount enclosure onto the top bracket by inserting bolts through
flange of the enclosure and into the bracket,
tightening bolts with a 7/16” hex socket (Fig. 13, pg. 6).
6. Tighten the straps of the bottom bracket down by sliding the open end of
the strap through the locking mechanism on the strap, then tighten screw
with flat head screwdriver or 5/16” hex socket driver (Fig. 13/13a, pg. 6).
7. Clip excess straps.
Fig. 13 - 2” to 8”(50.8mm to 203.2mm) Fig. 13a - 5” (127mm) square pole
diameter round pole
Fig. 9
Fig. 10
Fig. 11
Fig. 12
NetWay1DWP/NetWay1DWPH/NetWay1DWPM/NetWay1DWPMH - 7 -
Mechanical Drawing and Dimensions (H x W x D approx.):
9.5” x 7.32” x 4.92” (241.3mm x 185.9mm x 125mm)
7.32”
185.9mm
1.38”
35.1mm
1.5”
38mm
1.5”
38mm
1.5”
38mm
3.54”
89.9mm
8.0”
203.2mm
6.27”
159.3mm
10-32 X 0.25” (6.4mm)
4 Places
4.25” 108mm
4.35”
110.5mm
6.0” 152.4mm
6.75” 171.5mm
8.75”
222.2mm
8.75”
222.2mm
316 Stainless Steel
Padlock Latch Attached
0.375” (9.5mm) Padlock Eye
304 Stainless Steel
Piano Hinge
9.32”
236.7mm
4.92”
125mm
4.0” 101.6mm
9.5”
241.3mm
0.312” (7.9mm) TYP
4 Places
0.65” (16.5mm) three (3) 5/8” wiring inlets
on NetWay1DWPH and NetWay1DWPMH (only)
0.65” (16.5mm) three (3) 5/8” wiring inlets
on NetWay1DWPH and NetWay1DWPMH (only)
- 8 - NetWay1DWP/NetWay1DWPH/NetWay1DWPM/NetWay1DWPMH
Altronix is not responsible for any typographical errors.
140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056
website: www.altronix.com, e-mail: [email protected]. Lifetime Warranty, Made in U.S.A.
IINetWay1DWP/NetWay1DWPM L21P
MEMBER
Notes:
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8