IndustryAmp PB-800-CN data sheet rev 1.0
Power amps - Type : Full complementary FET class AB
- Power : 8 x 100 W
rms
(100 Ω)
- Protection : - DC failure
- Short circuit
- Output transformers : Toroidal
- Taps : 70 V, 100 V
- Minimum load : 100 Ω (@ 100V ), 50 Ω (@ 70 V)
- Loudspeaker terminal surge
protection clamping : 350 V @ 20 kA
Connectors
7
- Analogue audio inputs : Phoenix type MC 1,5/3-ST 3,81 (2 x)
8
p1 = Line 1 +, p2 = GND, p3 = Line 1 -
- CobraNet
®
interface : RJ-45 (2 x)
2
- RS-485 interface : Phoenix type MC 1,5/5-ST-3,81
p1 = DGND, p2 = Y, p3 = Z, p4 = B, p5 = A
- Ambient noise sensor : Phoenix MC 1,5/3-ST-3,81
p1 = In +, p2 = GND, p3 = In -
- Ambient temperature sensor (NTC) : Phoenix MC 1,5/2-ST-3,81
p1 = In, p2 = GND
- Failure relay : Phoenix type MC 1,5/3-ST-3,81
p1 = Common (CO), p2 = Normally closed (NC),
p3 = Normally open (NO)
9
- Loudspeakers : Phoenix type MC 2.5/3-ST-7.62 (8 x)
10
p1 = 0, p2 = 70 V, p3 = 100 V
- Mains : 3p male Neutric Powercon
PSU - Type : Switched-mode, power factor correction, standby supply
- Mains voltage : 100 V to 250 V, 50 or 60 Hz
- Mains fuse(s) : 1 x 6.3 A (slow type, integrated in mains switch)
- Power consumption : - 67 W (idle)
- 11 W standby (main power supply shut down)
- 140 W load monitoring active (all outputs 100 Ω)
- 1600 VA peak
- Power factor : 0.50 (idle) / > 0.90 (full load)
- Max mains inrush current : 20 A short-time peak (@ 230 V)
- Protection : - thermal protection
- output current limiting
- under-voltage and over-voltage lock out
General:
Temperature range (ambient) : 0 to 40 °C (32 - 104 °F)
Dimensions (H x W x D) : 132 x 483 x 342 mm (3U 19” rack enclosure)
Weight : 22.6 (50 lbs)
Finish : Nickel Plated
Notes:
1. The device supports 2 analogue audio inputs and 8 digital CobraNet
®
inputs.
2. The device is equipped with 2 RJ-45 sockets for a redundant CobraNet
®
connection.
3. The amplified signal from the ambient noise sensor input is available on 2 CobraNet
®
channels.
4. A-weighed, 10 to 22k Hz analyzer bandwidth, open input, 100 Ω load.
5. The device can either be accessed over RS-485 or over Ethernet by using the CobraNet
®
Serial Bridge protocol. The interfaces cannot be used
simultaneously.
6. Maximum number that can be connected to one subnet, multiple subnets can be controlled by one host PC. This also applies when accessing
over the CobraNet
®
Serial Bridge.
7. All Phoenix type numbers refer to the required cable parts, a complete set of Phoenix connectors is supplied with the product.
8. For solid and stranded wires with conductor cross sections from 0.14 to 1.5 mm
2
.
9. CO is connected to NC if the device is powered and the status is OK (no masked failure).
10. For solid and stranded wires with conductor cross sections from 0.2 to 2.5 mm
2
.