Hearth and Home Technologies SL-350TRS-D User manual

Category
Fireplaces
Type
User manual

This manual is also suitable for

Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev. D • 6/07 1
Models:
SL-750TRS-IPI-E
SL-550TRS-IPI-E
SL-350TRS-D
SL-350TRS-IPI
Owners Manual
Installation and Operation
Do not store or use gasoline or other am-
mable vapors and liquids in the vicinity of
this or any other appliance.
What to do if you smell gas
- Do not try to light any appliance
- Do not touch any electrical switch. Do not
use any phone in your building.
- Immediately call your gas supplier from a
neighbor’s phone. Follow the gas suppli-
er’s instructions.
- If you cannot reach your gas supplier, call
the re department.
Installation and service must be performed
by a quali ed installer, service agency, or the
gas supplier.
WARNING: If the information in these
instructions is not followed exactly, a re
or explosion may result causing property
damage, personal injury, or death.
DO NOT DISCARD THIS MANUAL
CAUTION
This appliance may be installed as an OEM installation in
manufactured home (USA only) or mobile home and must be
installed in accordance with the manufacturer’s instructions and
the manufactured home construction and safety standard, Title
24 CFR, Part 3280 or Standard for Installation in Mobile Homes,
CAN/CSA Z240MH.
This appliance is only for use with the type(s) of gas indicated
on the rating plate.
Installation and service of this appliance should be
performed by quali ed personnel. Hearth & Home
Technologies suggests NFI certi ed or factory trained
professionals, or technicians supervised by an NFI
certi ed professional.
Leave this manual with
party responsible for use
and operation.
DO NOT
DISCARD
WARNING
• Important operating
and maintenance
instructions included.
Read, understand and follow
these instructions for safe
installation and operation.
In the Commonwealth of Massachusetts:
installation must be performed by a licensed plumber
or gas tter;
See Table of Contents for location of additional
Commonwealth of Massachusetts requirements.
This appliance has been supplied with an integral barrier
to prevent direct contact with the xed glass panel. Do
NOT operate the appliance with the barrier removed.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install one.
HOT! DO NOT TOUCH.
SEVERE BURNS MAY RESULT.
CLOTHING IGNITION MAY RESULT.
CAREFULLY SUPERVISE children in same room as
appliance.
Alert children and adults to hazards of high temperatures.
Do NOT operate with protective barriers open or
removed.
Keep clothing, furniture, draperies and other combustibles
away.
Glass and other surfaces are hot during
operation and cool down.
Keep children away.
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev. D • 6/072
Congratulations
Listing Label Information/Location
Model Name: ___________________________________________ Date purchased/installed: __________________
Serial Number: __________________________________________ Location on appliance: ____________________
Dealership purchased from: _______________________________ Dealer Phone: __________________________
Notes: _______________________________________________________________________________________
_____________________________________________________________________________________________
Congratulations on selecting a Heat & Glo gas appliance
—an elegant and clean alternative to wood burning
appliances. The Heat & Glo gas appliance you have
selected is designed to provide the utmost in safety,
reliability, and ef ciency.
As the owner of a new appliance, you’ll want to read and
carefully follow all of the instructions contained in this
Owners Manual. Pay special attention to all Cautions and
Warnings.
This Owners Manual should be retained for future
reference. We suggest that you keep it with your other
important documents and product manuals.
The information contained in this Owner’s Manual, unless
noted otherwise, applies to all models and gas control
systems.
Your new Heat & Glo gas appliance will give you years of
durable use and trouble-free enjoyment. Welcome to the
Heat & Glo family of appliance products!
Read this manual before installing or operating this appliance.
Please retain this owner’s manual for future reference.
We recommend that you record the following pertinent
information about your appliance.
Gas and Electric
Information
Serial Number
Type of Gas
The model information regarding your speci c appliance can be found on
the rating plate usually located in the control area of the appliance.
Homeowner Reference Information
Heat & Glo, a of Hearth & Home Technologies, Inc.
20802 Kensington Boulevard, Lakeville, MN 55044
brand
Heat & Glo, a of Hearth & Home Technologies, Inc.
20802 Kensington Boulevard, Lakeville, MN 55044
brand
Not
Not
for
for
use
use
with
with
solid
solid
fuel.
fuel.
(
(
Ne
Ne
doit
doit
pas
pas
entre
entre
utilise
utilise
avec
avec
un
un
combustible
combustible
solide).
solide).
This
This
appliance
appliance
must
must
be
be
installed
installed
in
in
accordance
accordance
with
with
local
local
codes,
codes,
if
if
any;
any;
if
if
not,
not,
follow
follow
ANSI
ANSI
Z223.1
Z223.1
in
in
the
the
USA
USA
or
or
CAN/CGA
CAN/CGA
B149
B149
installation
installation
codes.
codes.
(Installer
(Installer
l’appareil
l’appareil
selon
selon
les
les
codes
codes
ou
ou
reglements
reglements
locaux
locaux
ou,
ou,
en
en
l’absence
l’absence
de
de
tels
tels
reglements,
reglements,
selon
selon
les
les
codes
codes
d’installation
d’installation
CAN/CGA-B149.)
CAN/CGA-B149.)
Type
Type
of
of
Gas
Gas
(Sorte
(Sorte
De
De
Gaz)
Gaz):
NA
TURAL
TURAL
GAS
GAS
MADE
MADE
IN
IN
USA
USA
Minimum
Minimum
Permissible
Permissible
Gas
Gas
Supply
Supply
for
for
Purposes
Purposes
of
of
Input
Input
Adjustment.
Adjustment.
Approved
Approved
Minimum
Minimum
(De
(De
Gaz)
Gaz)
Acceptable
Acceptable
0.0
0.0
in
in
w.c.
w.c.
(Po.
(Po.
Col.
Col.
d’eau)
d’eau)
Maximum
Maximum
Pressure
Pressure
(Pression)
(Pression)
0.0
0.0
in
in
w.c.
w.c.
(Po.
(Po.
Col.
Col.
d’eau)
d’eau)
Maximum
Maximum
Manifold
Manifold
Pressure
Pressure
(Pression)
(Pression)
0.0
0.0
in
in
w.c.
w.c.
(Po.
(Po.
Col.
Col.
d’eau)
d’eau)
Minimum
Minimum
Manifold
Manifold
Pressure
Pressure
(Pression)
(Pression)
0.0
0.0
in
in
w.c.
w.c.
(Po.
(Po.
Col.
Col.
d’eau)
d’eau)
Model:
Model:
(Modele):
(Modele):
Serial
Serial
(Serie):
(Serie):
ANSI
ANSI
Z21XX-XXXX
Z21XX-XXXX
·
·
CSA
CSA
2.XX-MXX
2.XX-MXX
·
·
UL307B
UL307B
XXXXXXXX
XXXXXXXX
IN
IN
CANADA
CANADA
ALTITUDE:
ALTITUDE:
0-0000
0-0000
FT.
FT.
0000-0000FT.
0000-0000FT.
MAX.
MAX.
INPUT
INPUT
BTUH:
BTUH:
00,000
00,000
00,000
00,000
MIN.
MIN.
INPUT
INPUT
BTUH:
BTUH:
00,000
00,000
00,000
00,000
ORIFICE
ORIFICE
SIZE:
SIZE:
#XXXXX
#XXXXX
#XXXXX
#XXXXX
XXXXXXXX
XXXXXXXX
Total
Total
Electrical
Electrical
Requirements:
Requirements:
000Vac,
000Vac,
00Hz.,
00Hz.,
less
less
than
than
00
00
Amperes
Amperes
This product may be covered by one or more of the following patents: (Nos produits sont couverts par un ou plusieurs des brevets suivants): (United States)
4593510, 4686807, 4766876, 4793322, 4811534, 5000162, 5016609, 5076254, 5113843, 5191877, 5218953, 5263471, 5328356, 5341794, 5347983, 5429495,
5452708, 5542407, 5601073, 5613487, 5647340, 5688568, 5762062, 5775408, 5890485, 5931661, 5941237, 5947112, 5996575, 6006743, 6019099, 6048195,
6053165, 6145502, 6170481, 6237588, 6296474, 6374822, 6413079, 6439226, 6484712, 6543698, 6550687, 6601579, 6672860, 6688302B2, 6715724B2,
6729551, 6736133, 6748940, 6748942, D320652, D445174, D462436; (Canada)1297749, 2195264, 2225408; or other U.S. and foreign patents pending (ou
autres brevets americains et etrangers en attente).
Model Number
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev. D • 6/07 3
Î = Contains updated information.
Table of Contents
1 Listing and Code Approvals
A. Appliance Certi cation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
B. Glass Speci cations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
C. BTU Speci cations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
D. High Altitude Installations . . . . . . . . . . . . . . . . . . . . . . . . . . 4
E. Non-Combustible Materials Speci cation. . . . . . . . . . . . . . 4
F. Combustible Materials Speci cation . . . . . . . . . . . . . . . . . 4
G. Requirements for the Commonwealth of Massachusetts . . 5
2 Getting Started
A. Design and Installation Considerations . . . . . . . . . . . . . . . 6
B. Tools and Supplies Needed . . . . . . . . . . . . . . . . . . . . . . . . 6
C. Inspect Appliance and Components . . . . . . . . . . . . . . . . . . 6
3 Framing and Clearances
A. Selecting Appliance Location . . . . . . . . . . . . . . . . . . . . . . . 7
B. Constructing the Appliance Chase . . . . . . . . . . . . . . . . . . . 8
C. Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
D. Elevated Hearth Systems . . . . . . . . . . . . . . . . . . . . . . . . . . 9
E. Mantel Projections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
4 Termination Locations
A. Vent Termination Minimum Clearances . . . . . . . . . . . . . . .11
5 Vent Information and Diagrams
A. Vent Table Key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
B. Use of Elbows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
C. Measuring Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
D. Use of Flex Vent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
E. Vent Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
6 Vent Clearances and Framing
A. Pipe Clearances to Combustibles . . . . . . . . . . . . . . . . . . 25
B. Wall Penetration Framing . . . . . . . . . . . . . . . . . . . . . . . . . 25
C. Vertical Penetration Framing . . . . . . . . . . . . . . . . . . . . . . 26
7 Appliance Preparation
A. Top Vent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
B. Rear Vent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
C. Securing and Leveling the Appliance . . . . . . . . . . . . . . . . 29
8 Installing Vent Pipe
A. Assembly of Vent Sections (DVP Pipe) . . . . . . . . . . . . . . 30
B. Disassembly of Vent Sections (DVP Pipe) . . . . . . . . . . . . 32
C. Installing Heat Shield and Horizontal Termination Cap
(DVP Pipe) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
D. Assembly of Vent Sections (SL pipe) . . . . . . . . . . . . . . . . 34
E. Installing Wall Shield Firestops and Horizontal
Termination Cap (SL Pipe) . . . . . . . . . . . . . . . . . . . . . . . . 35
F. Installing Roof Flashing and Vertical Termination Cap . . . 36
9 Gas Information
A. Fuel Conversions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
B. Gas Pressures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
C. Gas Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
10 Electrical Information
A. Recommendation for Wire . . . . . . . . . . . . . . . . . . . . . . . . 40
B. Connecting to the Appliance. . . . . . . . . . . . . . . . . . . . . . . 40
C. Intelli re Ignition System Wiring . . . . . . . . . . . . . . . . . . . . 41
D. Standing Pilot Ignition System Wiring . . . . . . . . . . . . . . . 41
E. Junction Box Installation. . . . . . . . . . . . . . . . . . . . . . . . . . 43
F. Wall Switch Installation for Fan (Optional) . . . . . . . . . . . . 43
11 Finishing
A. Mantel Projections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
B. Facing Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
C. Splatter Guard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
D. Doors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
12 Appliance Setup
A. Remove Shipping Materials . . . . . . . . . . . . . . . . . . . . . . . 49
B. Clean the Appliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
C. Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
D. Lava Rock, Mineral Wool/Ember Placement . . . . . . . . . . 49
E. Install Refractory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
F. Positioning the Logs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
G. Glass Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
H. Grilles and Trim . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
I. Air Shutter Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
13 Operating Instructions
A. Before Lighting Appliance. . . . . . . . . . . . . . . . . . . . . . . . . 58
B. Lighting Appliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
C. After Appliance is Lit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
D. Frequently Asked Questions . . . . . . . . . . . . . . . . . . . . . . 61
14 Troubleshooting
A. Standing Pilot Ignition System . . . . . . . . . . . . . . . . . . . . . 62
B. Intelli re Ignition System . . . . . . . . . . . . . . . . . . . . . . . . . 64
15 Maintaining and Servicing Appliance
A. Maintenance Tasks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
16 Reference Materials
A. Appliance Dimension Diagram . . . . . . . . . . . . . . . . . . . . . 68
B. Vent Components Diagrams . . . . . . . . . . . . . . . . . . . . . . 69
C. Service Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
D. Limited Lifetime Warranty . . . . . . . . . . . . . . . . . . . . . . . . . 84
E. Contact Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev. D • 6/074
MODELS: SL-750TRS-IPI-E,SL-550TRS-IPI-E,
SL-350TRS-D, SL-350TRS-IPI
LABORATORY: Underwriters Laboratories, Inc. (UL)
TYPE: Direct Vent Gas Appliance Heater
STANDARD: ANSI Z21.88a-2007 • CSA 2.33a-2007
Models
U.S. (0-2000 ft.) or
Canada (2000-4500 ft.)
Maximum
Input
BTU/h
Minimum
Input
BTU/h
Ori ce
Size
(DMS)
SL-750TRS-IPI-E (NG) U.S. 30,800 20,200 #37
Canada 27,720 18,180 #38
SL-750TRS-IPI-E (LP) U.S. 30,700 23.300 #52
Canada 27,630 20,970 #53
SL-550TRS-IPI-E (NG) U.S. 27,300 18,200 #40
Canada 24,570 16,380 #41
SL-550TRS-IPI-E (LP) U.S. 25,100 18,300 #53
Canada 22,590 16,470 #54
SL-350TRS-D (NG)
SL-350TRS-IPI (NG) U.S. 20,500 14,400 #44
Canada 18,450 12,960 #45
SL-350TRS-D (LP)
SL-350TRS-IPI (LP) U.S. 20,000 14,900 #55
Canada 18,000 13,410 #56
B. Glass Speci cations
Hearth & Home Technologies appliances manufactured
with tempered glass may be installed in hazardous loca-
tions such as bathtub enclosures as de ned by the Con-
sumer Product Safety Commission (CPSC). The tempered
glass has been tested and certi ed to the requirements
of ANSI Z97.1 and CPSC 16 CFR 1202 (Safety Glazing
Certi cation Council SGCC# 1595 and 1597. Architectur-
al Testing, Inc. Reports 02-31919.01 and 02-31917.01).
This statement is in compliance with CPSC 16 CFR Sec-
tion 1201.5 “Certi cation and labeling requirements”
which refers to 15 U.S. Code (USC) 2063 stating “…Such
certi cate shall accompany the product or shall otherwise
be furnished to any distributor or retailer to whom the
product is delivered.”
Some local building codes require the use of tempered
glass with permanent marking in such locations. Glass
meeting this requirement is available from the factory.
Please contact your dealer or distributor to order.
Note: This installation must conform with local codes. In the
absence of local codes you must comply with the National
Fuel Gas Code, ANSI Z223.1-latest edition in the U.S.A. and
the CAN/CGA B149 Installation Codes in Canada.
1
1 Listing and Code Approvals
C. BTU Speci cations
Do NOT use this appliance if any part has been under water.
Immediately call a quali ed service technician to inspect the
appliance and to replace any part of the control system and
any gas control which has been under water.
This product is listed to ANSI standards for “Vented Gas
Appliance Heaters” and applicable sections of “Gas Burn-
ing Heating Appliances for Manufactured Homes and
Recreational Vehicles”, and “Gas Fired Appliances for
Use at High Altitudes”.
Heat & Glo Quality Systems
registered by SGS ICS
A. Appliance Certi cation
E. Non-Combustible Materials Speci cation
Material which will not ignite and burn. Such materials are
those consisting entirely of steel, iron, brick, tile, concrete,
slate, glass or plasters, or any combination thereof. Mate-
rials that are reported as passing ASTM E 136, Standard
Test Method for Behavior of Materials in a Vertical
Tube Furnace at 750ºC, shall be considered non-com-
bustible materials.
F. Combustible Materials Speci cation
Materials made of or surfaced with wood, compressed
paper, plant bers, plastics, or other material that can ig-
nite and burn, whether ame proofed or not, or whether
plastered or unplastered shall be considered combustible
materials.
WARNING
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.
This appliance is tested and approved as either supplemen-
tal room heat or as a decorative appliance. It should not be
factored as primary heat in residential heating calculations. D. High Altitude Installations
U.L. Listed gas appliances are tested and approved with-
out requiring changes for elevations from 0 to 2000 feet in
the U.S.A. and Canada.
When installing this appliance at an elevation above 2000
feet, it may be necessary to decrease the input rating
by changing the existing burner ori ce to a smaller size.
Input rate should be reduced by 4% for each 1000 feet
above a 2000 foot elevation in the U.S.A., or 10% for el-
evations between 2000 and 4500 feet in Canada. If the
heating value of the gas has been reduced, these rules
do not apply. To identify the proper ori ce size, check with
the local gas utility.
If installing this appliance at an elevation above 4500 feet
(in Canada), check with local authorities.
Î
Î
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev. D • 6/07 5
G. Requirements for the Commonwealth of
Massachusetts
For all side wall horizontally vented gas fueled equipment
installed in every dwelling, building or structure used in
whole or in part for residential purposes, including those
owned or operated by the Commonwealth and where the
side wall exhaust vent termination is less than seven (7)
feet above nished grade in the area of the venting, in-
cluding but not limited to decks and porches, the following
requirements shall be satis ed:
Installation of Carbon Monoxide Detectors
At the time of installation of the side wall horizontal vented
gas fueled equipment, the installing plumber or gas tter
shall observe that a hard wired carbon monoxide detector
with an alarm and battery back-up is installed on the oor
level where the gas equipment is to be installed. In addi-
tion, the installing plumber or gas tter shall observe that
a battery operated or hard wired carbon monoxide detec-
tor with an alarm is installed on each additional level of
the dwelling, building or structure served by the side wall
horizontal vented gas fueled equipment. It shall be the
responsibility of the property owner to secure the services
of quali ed licensed professionals for the installation of
hard wired carbon monoxide detectors.
In the event that the side wall horizontally vented gas fu-
eled equipment is installed in a crawl space or an attic,
the hard wired carbon monoxide detector with alarm and
battery back-up may be installed on the next adjacent
oor level.
In the event that the requirements of this subdivision can
not be met at the time of completion of installation, the
owner shall have a period of thirty (30) days to comply
with the above requirements; provided, however, that dur-
ing said thirty (30) day period, a battery operated carbon
monoxide detector with an alarm shall be installed.
Approved Carbon Monoxide Detectors
Each carbon monoxide detector as required in accor-
dance with the above provisions shall comply with NFPA
720 and be ANSI/UL 2034 listed and IAS certi ed.
Signage
A metal or plastic identi cation plate shall be permanent-
ly mounted to the exterior of the building at a minimum
height of eight (8) feet above grade directly in line with the
exhaust vent terminal for the horizontally vented gas fu-
eled heating appliance or equipment. The sign shall read,
in print size no less than one-half (1/2) inch in size, “GAS
VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB-
STRUCTIONS”.
Inspection
The state or local gas inspector of the side wall horizon-
tally vented gas fueled equipment shall not approve the
installation unless, upon inspection, the inspector ob-
serves carbon monoxide detectors and signage installed
in accordance with the provisions of 248 CMR 5.08(2)(a)1
through 4.
Exemptions
The following equipment is exempt from 248 CMR
5.08(2)(a)1 through 4:
• The equipment listed in Chapter 10 entitled “Equip-
ment Not Required To Be Vented” in the most current
edition of NFPA 54 as adopted by the Board; and
Product Approved side wall horizontally vented gas fu-
eled equipment installed in a room or structure sep-
arate from the dwelling, building or structure used in
whole or in part for residential purposes.
MANUFACTURER REQUIREMENTS
Gas Equipment Venting System Provided
When the manufacturer of Product Approved side wall
horizontally vented gas equipment provides a venting
system design or venting system components with the
equipment, the instructions provided by the manufacturer
for installation of the equipment and the venting system
shall include:
Detailed instructions for the installation of the venting
system design or the venting system components; and
A complete parts list for the venting system design or
venting system.
Gas Equipment Venting System NOT Provided
When the manufacturer of a Product Approved side wall
horizontally vented gas fueled equipment does not pro-
vide the parts for venting the ue gases, but identi es
“special venting systems”, the following requirements
shall be satis ed by the manufacturer:
The referenced “special venting system” instructions
shall be included with the appliance or equipment in-
stallation instructions; and
The “special venting systems” shall be Product Ap-
proved by the Board, and the instructions for that sys-
tem shall include a parts list and detailed installation
instructions.
A copy of all installation instructions for all Product Ap-
proved side wall horizontally vented gas fueled equip-
ment, all venting instructions, all parts lists for venting
instructions, and/or all venting design instructions shall
remain with the appliance or equipment at the completion
of the installation.
See Gas Connection section for additional Common-
wealth of Massachusetts requirements.
Note: The following requirements reference various
Massachusetts and national codes not contained in this
document.
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev. D • 6/076
A. Design and Installation Considerations
Heat & Glo direct vent gas appliances are designed to
operate with all combustion air siphoned from outside of
the building and all exhaust gases expelled to the out-
side. No additional outside air source is required.
2
2 Getting Started
C. Inspect Appliance and Components
When planning an appliance installation, it’s necessary to
determine the following information before installing:
• Where the appliance is to be installed.
• The vent system con guration to be used.
• Gas supply piping.
• Electrical wiring.
• Framing and nishing details.
Whether optional accessories—devices such as a fan,
wall switch, or remote control—are desired.
B. Tools and Supplies Needed
Before beginning the installation be sure that the following
tools and building supplies are available.
Reciprocating saw Framing material
Pliers Hi temp caulking material
Hammer Gloves
Phillips screwdriver Framing square
Flat blade screwdriver Electric drill and bits (1/4 in.)
Plumb line Safety glasses
Level 1/2 - 3/4 inch length, #6 or #8 Self-drilling screws
Manometer Voltmeter
Tape measure Noncorrosive leak check solution
One 1/4 inch female connection (for optional fan).
Carefully remove the appliance and components from
the packaging.
The vent system components and trim doors are shipped
in separate packages.
The gas logs may be packaged separately and must be
eld installed.
Report to your dealer any parts damaged in shipment,
particularly the condition of the glass.
Read all of the instructions before starting the insta-
llation. Follow these instructions carefully during the
installation to ensure maximum safety and bene t.
Check building codes prior to installation.
Installation MUST comply with local, regional, state and
national codes and regulations.
Consult local building, re of cials or authorities having jurisdic-
tion about restrictions, installation inspection, and permits.
CAUTION
Keep appliance dry.
Mold or rust may cause odors.
Water may damage controls.
Inspect appliance and components for damage.
Damaged parts may impair safe operation.
Do NOT install damaged components.
Do NOT install incomplete components.
Do NOT install substitute components.
Report damaged parts to dealer.
Hearth & Home Technologies disclaims any
responsibility for, and the warranty will be voided
by, the following actions:
Installation and use of any damaged appliance or vent
system component.
• Modi cation of the appliance or vent system.
Installation other than as instructed by Hearth & Home
Technologies.
Improper positioning of the gas logs or the glass door.
Installation and/or use of any component part not approved
by Hearth & Home Technologies.
Any such action may cause a re hazard.
WARNING
WARNING
WARNING
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev. D • 6/07 7
K
C
A
L
F
I
B
G
E
D
J
JG
A
F
CA
H
M
N
In addition to these framing dimensions, also reference the following sections:
Clearances and Mantel Projections (Section 3.C and 3.D)
Vent Clearances and Framing (Section 6).
3
3 Framing and Clearances
Note:
Illustrations reflect typical installations and are FOR
DESIGN PURPOSES ONLY.
Illustrations/diagrams are not drawn to scale.
Actual installation may vary due to individual design
preference.
Fire Risk
Provide adequate clearance:
Around air openings
• To combustibles
• For service access
Locate appliance away from traf c areas.
A. Selecting Appliance Location
When selecting a location for your appliance it is important to
consider the required clearances to walls (see Figure 3.1).
Figure 3.1 Appliance Locations
NOTE: For actual appliance dimensions refer to Sec-
tion 16.
WARNING
Models A B C D E
Min. F
Min. GH I JKL M N
SL-750TRS-IPI-E in. 45-1/2 42 64-3/8
See Section
E for Alcove
Installation
1 1/2 45-1/2 64-3/8 16-1/4 48-1/2 68-3/4 16-5/8 7-1/2 9
mm 1155 1067 1635 25 13 1155 1635 413 1232 1737 422 191 229
SL-550TRS-IPI-E in. 42 37 59-1/2 1 1/2 44 62-1/4 16-1/4 48-1/2 68-3/4 15-1/16 7-1/2 7-1/8
mm 1067 940 1511 25 13 1117 1581 413 1232 1737 383 191 181
SL-350TRS-D in. 39-1/2 34 55-7/8 1 1/2 44 62-1/4 16-1/4 48-1/2 68-3/4 13-1/2 7-1/2 6
mm 1003 864 1413 25 13 1117 1581 413 1232 1737 343 191 152
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev. D • 6/078
Figure 3.2 Clearances to Combustibles
C
B
D
A
Models
ABCDEFGHIJ
DVP PIPE SL PIPE Rough
Opening
(Height)
*DVP PIPE SL PIPE Rough
Opening
(Width)
Clearance
to Ceiling Combustible
Floor Combustible
Flooring Behind
Appliance Sides of
Appliance Front of
Appliance
Rough
Opening
(Width)
Rough
Opening
(Width)
Rough
Opening
(Depth)
Rough
Opening
(Depth)
SL-750TRS-IPI-E Inches 10 8-5/8 38-1/4 28-1/4 16-1/4 42 32 0 0 1/2 1/2 36
Millimeters 254 219 971 699 413 1067 813 0 0 13 13 915
SL-550TRS-IPI-E Inches 10 8-5/8 34-3/4 28-1/4 16-1/4 37 32 0 0 1/2 1/2 36
Millimeters 254 219 882 699 413 940 813 0 0 13 13 915
SL-350TRS-D Inches 10 8-5/8 32-3/4 28-1/4 16-1/4 34 32 0 0 1/2 1/2 36
Millimeters 254 219 832 699 413 864 813 0 0 13 13 915
E
H
I
F
G
J
MEASURE FROM
TOP OF UNIT OPENING
OR FROM TOP OF HOOD
Fire Risk.
Construct chase to all clearance speci cations
in manual.
Locate and install appliance to all clearance
speci cations in manual.
B. Constructing the Appliance Chase
A chase is a vertical boxlike structure built to enclose the
gas appliance and/or its vent system. Vertical vents that
run on the outside of a building may be, but are not re-
quired to be, installed inside a chase.
Construction of the chase may vary with the type of build-
ing. These instructions are not substitutes for the require-
ments of local building codes. Local building codes MUST
be checked.
Chases should be constructed in the manner of all out-
side walls of the home to prevent cold air drafting prob-
lems. The chase should not break the outside building
envelope in any manner.
Walls, ceiling, base plate and cantilever oor of the chase
should be insulated. Vapor and air in ltration barriers
should be installed in the chase as per regional codes for
the rest of the home. Additionally, in regions where cold
air in ltration may be an issue, the inside surfaces may be
sheetrocked and taped for maximum air tightness.
To further prevent drafts, the wall shield and ceiling
restops should be caulked with high temperature caulk
to seal gaps. Gas line holes and other openings should
be caulked with high temp caulk or stuffed with unfaced
C. Clearances
Fire Risk.
Odor Risk.
Install appliance on hard metal or wood surfaces
extending full width and depth of appliance.
Do NOT install appliance directly on carpeting,
vinyl, tile or any combustible material other than
wood.
insulation. If the appliance is being installed on a cement
slab, a layer of plywood may be placed underneath to pre-
vent conducting cold up into the room.
WARNING
WARNING
* Dimension when rear venting with one 90º elbow
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev. D • 6/07 9
D. Elevated Hearth Systems
Use the table below to identify the hearth system that will be used. The table will also help identify effects on the various dimensions.
Some hearth systems will elevate the appliance off the oor at a given dimension. For example, if appliance will be used with a
Kenwood Cabinet with Base, the appliance will be elevated 9-1/4 inches. The 9-1/4 inch elevation will also have to be added to the
following: Extension Wall Hole referenced in Figure 6.3 (Exterior Wall Hole) and Rough Opening Height (header height) referenced in
Figure 3.2. NOTE: Finished oor thickness should also be considered when determining installation dimensions.
MODEL DESCRIPTION PART # ELEVATED APPLIANCE
DIMENSION
See Note 1
MARBLE LEG CUT
LENGTH
See Note 2
SL-350
KENWOOD CABINET KDC44SBP 0 27 3/8 in.
KENWOOD CABINET W/ BASE KDC44SBP W/ HTKDC44SBP 9 1/4 in. 27 3/8 in.
KENWOOD CORNER CABINET KDA44SBP 0 27 3/8 in.
KENWOOD CORNER CABINET W/ BASE KDA44SBP W/ HTKDA44SBP 9 1/4 in. 27 3/8 in.
SL-550
KENWOOD CABINET KDC44SBP 0 29-3/8 in.
KENWOOD CABINET W/ BASE KDC44SBP W/ HTKDC44SBP 9-1/4 in. 29-3/8 in.
KENWOOD CORNER CABINET KDA44SBP 0 29-3/8 in.
KENWOOD CORNER CABINET W/ BASE KDA44SBP W/ HTKDA44SBP 9-1/4 in. 29-3/8 in.
KENWOOD MANTEL AFKDMPA 0 (See Note 3) 27-3/8 in.
KENWOOD MANTEL W/ BASE AFKDMPA W/ HTKDMPA 9 1/4 in. 29-3/8 in.
LAURENT SURROUND LAURENT-32 1-1/2 in. N/A
CAMDEN SURROUND CAM550PG 0 N/A
CAMDEN SURROUND W/HEARTH CAM550PGH 1-3/4 in. N/A
CAMDEN SURROUND W/MANTEL CAMM550PG 0 N/A
CAMDEN SURROUND W/MANTEL &
HEARTH CAMM550PGH 1-3/4 in. N/A
ESSEX SURROUND ESSEX550PG 0 N/A
ESSEX SURROUND W/HEARTH ESSEX550PGH 1-3/4 in. N/A
ESSEX SURROUND W/MANTEL ESSEXM550PG 0 N/A
ESSEX SURROUND W/MANTEL &
HEARTH ESSEXM550PGH 1-3/4 in. N/A
MONROE SURROUND MON550PG 0 N/A
MONROE SURROUND W/HEARTH MON550PGH 1-3/4 in. N/A
MONROE SURROUND W/MANTEL MONM550PG 0 N/A
MONROE SURROUND W/MANTEL &
HEARTH MONM550PGH 1-3/4 in. N/A
SL-750
KENWOOD CABINET KDC48DBP 0 32-7/8 in.
KENWOOD CABINET W/ BASE KDC48DBP W/ HTKDC48DBP 9-1/4 in. 32-7/8 in.
KENWOOD CORNER CABINET KDA48SBP 0 32-7/8 in.
KENWOOD CORNER CABINET W/ BASE KDA48SBP W/ HTKDA48SBP 9-1/4 in. 32-7/8 in.
KENWOOD MANTEL AFKDMPB 0 (See Note 3) 27-3/8 in.
KENWOOD MANTEL W/ BASE AFKDMPB W/ HTKDMPB 9-1/4 in. 29-3/8 in.
LAURENT SURROUND LAURENT-36 1-1/2 in. N/A
CAMDEN SURROUND CAM36PG 0 N/A
CAMDEN SURROUND W/HEARTH CAM36PGH 1-3/4 in. N/A
CAMDEN SURROUND W/MANTEL CAMM36PG 0 N/A
CAMDEN SURROUND W/MANTEL &
HEARTH CAMM36PGH 1-3/4 in. N/A
ESSEX SURROUND ESSEX36PG 0 N/A
ESSEX SURROUND W/HEARTH ESSEX36PGH 1-3/4 in. N/A
ESSEX SURROUND W/MANTEL ESSEXM36PG 0 N/A
ESSEX SURROUND W/MANTEL &
HEARTH ESSEXM36PGH 1-3/4 in. N/A
MONROE SURROUND MON36PG 0 N/A
MONROE SURROUND W/HEARTH MON36PGH 1-3/4 in. N/A
MONROE SURROUND W/MANTEL MONM36PG 0 N/A
MONROE SURROUND W/MANTEL &
HEARTH MONM36PGH 1-3/4 in. N/A
NOTE 1. Add dimensions to Exterior Wall Hole (Figure 6.3) and Rough Opening Height (Figure 3.2).
NOTE 2. Verify Marble Cut Lengths on site prior to cutting.
NOTE 3. Dimensions assume use of a 3/4 in. Hearth Pad.
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev. D • 6/0710
E. Mantel Projections
5678910
345
12
11
10
9
8
7
6
TOP OF HOOD OR FIREPLACE OPENING
4
12 13
11
32
CEILING
All measurements are in inches.
Figure 3.3 Clearances to mantels or other combustibles
above appliance
1/2 in.
SHEETROCK
3-1/2 in.
1/2 in.
NON-COMBUSTIBLE ZONE
NON-COMBUSTIBLE
BOARD SHIPPED
WITH APPLIANCE
Figure 3.4 Non-Combustible Zone
3 FT. MAXIMUM
2-7/8 IN.
MINIMUM
1/2 IN.
MINIMUM
Note: Clearance from opening
to perpendicular wall.
Figure 3.5 Clearances to Mantel Legs or Wall Projections
(Acceptable on both sides of opening.)
5-3/8 IN.
MINIMUM
3 IN.
MINIMUM
UNLIMITED
Note: Clearance from opening
to perpendicular wall.
Figure 3.6 Wall Projection (Acceptable on one side of opening.)
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev. D • 6/07 11
A. Vent Termination Minimum Clearances
Fire Risk.
Explosion Risk.
Maintain vent clearance to combustibles as
speci ed.
Do not pack air space with insulation or other
materials.
Failure to keep insulation or other materials
away from vent pipe may cause re.
Roof Pitch H (Min.) Ft.
Flat to 6/12...........................................................1.0*
Over 6/12 to 7/12 .................................................1.25*
Over 7/12 to 8/12 .................................................1.5*
Over 8/12 to 9/12 .................................................2.0*
Over 9/12 to 10/12 ...............................................2.5
Over 10/12 to 11/12 .............................................3.25
Over 11/12 to 12/12 .............................................4.0
Over 12/12 to 14/12 .............................................5.0
Over 14/12 to 16/12 .............................................6.0
Over 16/12 to 18/12 .............................................7.0
Over 18/12 to 20/12 .............................................7.5
Over 20/12 to 21/12 .............................................8.0
Figure 4.1
Figure 4.2 Minimum height from roof to lowest discharge
opening
4
4 Termination Locations
Measure horizontal clearances from this surface.
Measure vertical clearances from this surface.
Figure 4.3 Multiple Vertical Termination
Figure 4.2 speci es minimum vent heights for various
pitched roofs.
(See Figure 4.4 for speci c clearances)
* 3 foot minimum in snow regions
HORIZONTAL
OVERHANG
VERTICAL
WALL
GAS DIRECT VENT
TERMINATION CAP
12
X
ROOF PITCH
IS X/ 12
LOWEST
DISCHARGE
OPENING
2 FT.
MIN.
20 INCHES MIN.
H (MIN.) - MINIMUM HEIGHT FROM ROOF
TO LOWEST DISCHARGE OPENING
C
A
GAS
TERMINATION
B
GAS, WOOD OR FUEL
OIL TERMINATION
WARNING
Gas
Termination Wood & Fuel Oil
Termination Comments
A6 in. 20 in. min. Horizontal distance between terminations
B20 in. 24 in. min. Distance to perpendicular wall
C18 in. 18 in. Vertical distance between terminations
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev. D • 6/0712
V= VENT TERMINAL X= AIR SUPPLY INLET = AREA WHERE TERMINAL IS NOT PERMITTED
Figure 4.4 Minimum Clearances for Termination
A = 12 inches.................clearances above grade, veranda,
porch, deck or balcony
B = 12 inches.................clearances to window or door
that may be opened, or to perma-
nently closed window. (Glass)
D* = 18 inches.................vertical clearance to unventilated
sof t or to ventilated sof t located
above the terminal
*30 inches ................for vinyl clad sof ts and below
electrical service
F = 9 inches..................clearance to outside corner
G = 6 inches...................clearance to inside corner
H = 3 ft. (Canada) ..........not to be installed above a gas
meter/regulator assembly within 3
feet (90 cm) horizontally from the
center-line of the regulator
I = 3 ft ...........................clearance to gas service regulator
vent outlet
J = 9 inches (U.S.A.)
12 inches (Canada) clearance to non-mechanical
air supply inlet to building or the
combustion air inlet to any other
appliance
K = 3 ft. (U.S.A.)
6 ft. (Canada) ...........clearance to a mechanical (pow-
ered) air supply inlet
CAUTION: IF EXTERIOR WALLS ARE FINISHED WITH VINYL SIDING, IT IS SUGGESTED THAT A VINYL PROTECTOR KIT BE INSTALLED.
** a vent shall not terminate directly above a sidewalk or paved driveway
which is located between two single family dwellings and serves both
dwellings.
*** only permitted if veranda, porch, deck or balcony is fully open on a
minimum of 2 sides beneath the oor, or meets Note 2.
NOTE 1: On private property where termination is less than 7 feet above
a sidewalk, driveway, deck, porch, veranda or balcony, use of a listed cap
shield is suggested. (See vents components page)
NOTE 2: Termination in an alcove space (spaces open only on one side
and with an overhang) are permitted with the dimensions speci ed for
vinyl or non-vinyl siding and sof ts. 1. There must be 3 feet minimum
between termination caps. 2. All mechanical air intakes within 10 feet
of a termination cap must be a minimum of 3 feet below the termination
cap. 3. All gravity air intakes within 3 feet of a termination cap must be a
minimum of 1 foot below the termination cap.
(See Note 1)
(See Note 2)
NOTE 3: Local codes or regulations may require different
clearances.
NOTE 4: Termination caps may be hot. Consider their proximity to
doors or other traf c areas.
NOTE 5: Location of the vent termination must not interfere with
access to the electrical service.
WARNING: In the U.S: Vent system termination is NOT permitted in
screened porches. You must follow side wall, overhang and ground
clearances as stated in the instructions.
In Canada: Vent system termination is NOT permitted in screened
porches. Vent system termination is permitted in porch areas with
two or more sides open. You must follow all side walls, overhang
and ground clearances as stated in the instructions.
Heat & Glo assumes no responsibility for the improper performance
of the appliance when the venting system does not meet these
requirements.
Electrical
Service
V
S
VS
V
T
D*
V
MN
P
R
Q
N = 6 inches ..................non-vinyl sidewalls
12 inches ................vinyl sidewalls
P = 8 ft.
QMIN RMAX
1 cap 3 feet 2 x Q ACTUAL
2 caps 6 feet 1 x Q ACTUAL
3 caps 9 feet 2/3 x Q ACTUAL
4 caps 12 feet 1/2 x Q ACTUAL
QMIN = # termination caps x 3 RMAX = (2 / # termination caps) x QACTUAL
Alcove Applications
(See Note 1)
(See Note 5)
(See Note 5)
L** = 7 ft. ......................... clearance above paved
sidewalk or a paved driveway
located on public property
M*** = 18 inches................ clearance under veranda, porch,
deck, balcony or overhang
42 inches ............... vinyl
S = 6 inches................. clearance from sides of electri-
cal service
T = 12 inches................ clearance above electrical
service
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev. D • 6/07 13
Fire Hazard.
Explosion Risk.
Asphyxiation Risk.
Do NOT connect this gas appliance to a chimney
ue serving a separate solid-fuel or gas burning
appliance.
Vent this appliance directly outside.
Use separate vent system for this appliance.
May impair safe operation of this appliance or
other appliances connected to the ue.
CAUTION
ALL vent con guration speci cations MUST be followed.
This product is tested and listed to these speci cations.
Appliance performance will suffer if speci cations are not
followed.
B. Use of Elbows
Diagonal runs have both vertical and horizontal vent as-
pects when calculating the effects. Use the rise for the
vertical aspect and the run for the horizontal aspect (see
Figure 5.1).
Two 45º elbows may be used in place of one 90º elbow. On
45º runs, one foot of diagonal is equal to 8.5 inches hori-
zontal run and 8.5 inches vertical run. A length of straight
pipe is allowed between two 45º elbows (see Figure 5.1).
Figure 5.1
5
5 Vent Information and Diagrams
A. Vent Table Key
The abbreviations listed in this vent table key are used in
the vent diagrams.
C. Measuring Standards
Vertical and horizontal measurements listed in the vent
diagrams were made using the following standards.
1. Pipe measurements are shown using the effective length
of pipe (see Figure 5.2).
2. Measurements are made from the appliance outer wrap,
not from the standoffs.
3. Horizontal terminations are measured to the outside
mounting surface ( ange of termination cap) (see
Figure 4.1).
4. Vertical terminations are measured to bottom of termi-
nation cap.
5. Horizontal pipe installed level with no rise.
Figure 5.2 DVP Pipe Effective Length
Effective
Height/Length
Symbol Description
V1First section (closest to appliance) of vertical length
V2Second section of vertical length
H1First section (closest to appliance) of horizontal length
H2Second section of horizontal length
Horizontal
Vertical
8-1/2 in.
8-1/2 in.
12 in.
Pipe Effective Length
Inches Millimeters
DVP4 4 102
DVP6 6 152
DVP12 12 305
DVP24 24 610
DVP36 36 914
DVP48 48 1219
DVP6A 3 to 6 76 to 152
DVP12A 3 to 12 76 to 305
DVP12MI 3 to 12 76 to 305
DVP24MI 3 to 24 76 to 610
WARNING
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev. D • 6/0714
3in.CLEARANCE TERMINATION
CAP
FLEX-VENT
1in.
CLEARANCE
D. Use of Flex Vent
The ex vent must be supported with
the spacing between support intervals
not exceeding 4 feet, with no more
than ½ inch sag between supports.
A support is required at each change
in venting direction, and in any location
where it is necessary to maintain the
necessary clearance to combustibles.
A simple “up and out” installation (Fig-
ure 5.3) requires only enough support
to maintain the necessary clearance
to combustibles. However, the vent at-
tachment point and the restop loca-
tion are considered to be supports.
Figure 5.3
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev. D • 6/07 15
Figure 5.4
E. Vent Diagrams
1. Top Vent - Horizontal Termination Venting
V Minimum H1 Maximum
SL-350TRS-D SL-550, SL-750TRS-E
90º Elbow 1-1/2 ft. 457 mm 1 ft. 305 mm
1/2 ft. 152 mm 2 ft. 610 mm 2 ft. 610 mm
1-1/2 ft. 457 mm 3 ft. 914 mm 3 ft. 914 mm
2-1/2 ft. 762 mm 5 ft. 1-1/2 m 5 ft. 1-1/2 m
3-1/2 ft. 1.1 m 7 ft. 2.1 m 7 ft. 2.1 m
4-1/2 ft. 1.4 m 15 ft. 4.6 m 15 ft. 4.6 m
H1 Maximum= 15 ft. (4.6 m)
V1 + H1 Maximum= 40 ft. (12.2 m)
Note: Use SL-D Series
components only.
Note: There MUST be a 25%
reduction in total H when using
ex vent except when using the
simple up and out installation
(see Figure 5.3).
Fire Risk. Explosion Risk.
Do NOT pack insulation or other combustibles between ceiling restops.
ALWAYS maintain speci ed clearances around venting and restop systems.
Install wall shield and ceiling restops as speci ed.
Failure to keep insulation or other material away from vent pipe may cause re.
WARNING
V1
H1
One Elbow
Fire Risk.
When using SL-HRC-SS and SL-HRC-ZC-SS
termination caps on top vented replaces, a one
foot minimum vertical vent section is required
before installing rst elbow.
WARNING
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev. D • 6/0716
H1
H2V1
Figure 5.5
Two Elbows
V Minimum H Maximum
SL-350TRS-D, SL-550TRS-E, SL-750TRS-E
90º Elbow NOT ALLOWED
1/2 ft. 152 mm 1 ft. 305 mm
1-1/2 ft. 457 mm 2 ft. 610 mm
2-1/2 ft. 762 mm 4 ft. 1.2 m
3-1/2 ft. 1.1 m 6 ft 1.8 m
4-1/2 ft. 1.4 m 14 ft. 4.3 m
H1 + H2 Maximum= 14 ft. (4.3 m)
V1 + H1 + H2 Maximum= 40 ft. (12.2 m)
Note: Use SL-D Series
components only.
Note: There MUST be a 25%
reduction in total H when using
ex vent except when using the
simple up and out installation
(see Figure 5.3).
Fire Risk.
When using SL-HRC-SS and SL-HRC-ZC-SS
termination caps on top vented replaces, a one
foot minimum vertical vent section is required
before installing rst elbow.
WARNING
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev. D • 6/07 17
Figure 5.6
1. Top Vent - Horizontal Termination - (continued)
Three Elbows
H1
H2
V1
V2
V1 Minimum H1 Maximum H1 + H2 Maximum H1 Maximum H1 + H2 Maximum
Model: SL-350TRS-D Models: SL-550TRS-IPI-E, SL-750TRS-IPI-E
Elbow only 1-1/2 ft. 457 mm 2 ft. 610 mm 1 ft. 305 mm 2 ft. 610 mm
1/2 ft. 152 mm 2 ft. 610 mm 4 ft. 1.2 m 2 ft. 610 mm 4 ft. 1.2 m
1-1/2 ft. 457 mm 3 ft. 914 mm 6 ft. 1.8 m 3 ft. 914 mm 6 ft. 1.8 m
2-1/2 ft. 762 mm 5 ft. 1.5 m 10 ft 3.0 m 5 ft. 1.5 m 10 ft. 3.0 m
3-1/2 ft. 1.1 m 7 ft. 2.1 m 14 ft. 4.3 m 7 ft. 2.1 m 14 ft. 4.3 m
4-1/2 ft. 1.4 m 14 ft. 4.3 m 14 ft. 4.3 m 14 ft. 4.3 m 14 ft. 4.3 m
V1 + H1 + V2 + H2 Maximum = 40 ft. (12.2 m)
Note: Use SL-D Series
components only.
Note: There MUST be a 25%
reduction in total H when using
ex vent except when using the
simple up and out installation
(see Figure 5.3).
Fire Risk.
When using SL-HRC-SS and SL-HRC-ZC-SS
termination caps on top vented replaces, a one
foot minimum vertical vent section is required
before installing rst elbow.
WARNING
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev. D • 6/0718
2. Top Vent - Vertical Termination
No Elbow
V1 = 44 ft. Max. (13.4 m)
Note: Use SL-D Series
components only.
Figure 5.8
INNER HEAT SHIELD
Top Vent Application
Rear Vent Application
Note: Be sure to re-
install the inner heat
shield after exhaust
restrictor installation.
Figure 5.7
CAP
V1
Exhaust restrictors are recommended for these verti-
cally terminated products which have excessive draft.
Exhaust restrictors will compensate for high draft, and
restore visual ame height. If the vent con guration has
a total vertical of 15-44 feet, an exhaust restrictor may
be needed. The exhaust restrictor can be located in the
appliance manual bag.
Exhaust restrictor Instructions
1. Install the exhaust restrictor over the center of the ex-
haust outlet in the rebox (see Figure 5.8).
2. Center the exhaust restrictor in the open end of the
exhaust outlet and secure through the slots on the ex-
haust restrictor with the 2-1/4 in. self tapping screws
provided in the appliance manual bag.
Exhaust restrictor
Exhaust restrictor
To access the
exhaust openings,
remove the inner
heat shield. To
remove inner heat
shield, remove the
two screws.
Note: If installing a vertical vent/termination off the top of
the appliance, the optional vertical termination baf e may
be needed.
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev. D • 6/07 19
Figure 5.8
Two 90º Elbows
H1
V1
V2
V1 Minimum H1 Maximum H1 Maximum V2V1 + V2 Minimum
SL-350TRS-D SL-550TRS-E, SL-750TRS-E * *
90º Elbow 1-1/2 ft. 457 mm 1 ft. 305 mm * *
1/2 ft. 152 mm 2 ft. 610 mm 2 ft. 610 mm * *
1 ft. 305 mm 2-1/2 ft. 762 mm 2-1/2 ft. 762 mm * *
2 ft. 610 mm 4 ft. 1.2 m 4 ft. 1.2 m * *
3 ft. 914 m 6 ft. 1.8 m 6 ft. 1.8 m * *
4 ft. 1.2 m 8 ft. 2.4 m 8 ft. 2.4 m * *
5 ft. 1.5 m 15 ft. 4.6 m 15 ft 4.6 m * *
H1 Maximum= 15 ft. (4.6 m)
V1 + V2 + H Maximum = 40 ft. (12.2 m)
*No speci c restrictions on this value EXCEPT V1 + V2 + H1 CANNOT exceed 40 ft. (12.2 m)
Note: Use SL-D Series
components only.
Note: There MUST be a 25%
reduction in total H when using
ex vent except when using the
simple up and out installation
(see Figure 5.3).
2. Top Vent - Vertical Termination - (continued)
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev. D • 6/0720
Figure 5.9
2. Top Vent - Vertical Termination - (continued)
Three 90º Elbows
H1
H2V1
V2
ALL MODELS
V1 H
1+ H2 Maximum V2V1 + V2 Minimum
90º Elbow 0 0 1-1/2 ft. 457 mm 1-1/2 ft. 457 mm
1/2 ft.. 152 mm 1 ft. 305 mm * * * *
1-1/2 ft. 457 mm 2 ft. 610 mm * * * *
2-1/2 ft. 762 mm 4 ft. 1.2 m * * * *
3-1/2 ft. 1.1 m 6 ft. 1.8 m * * * *
4-1/2 ft. 1.4 m 14 ft. 4.3 m * * * *
H1 Maximum = 14 ft. (4.3 m)
*No speci c restrictions on this value EXCEPT V1 + V2 + H1 + H2
CANNOT exceed 40 ft. (12.2 m).
Note: Use SL-D Series
components only.
Note: There MUST be a 25%
reduction in total H when using
ex vent except when using the
simple up and out installation
(see Figure 5.3).
Î
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85

Hearth and Home Technologies SL-350TRS-D User manual

Category
Fireplaces
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI