Simons Voss INPUT NODE User manual

Type
User manual

Simons Voss INPUT NODE is a central node that transmits remote opening or emergency activation to a lock node or directly networked cylinder by radio, replacing the switching transponder (TRA.SCHALT) and eliminating the need for wiring. It can be configured using a PC or laptop with a USB data cable, and requires a power supply unit with 230V AC / USB 5V DC controlled output. The device has a maximum transmission power of 5 dBm (3.16 mW) at the antenna socket, a sensitivity of -90 dBm at 19.2 kBaud, and operates in the 868 MHz frequency band. It features an external antenna and has dimensions of 100 x 65 x 40 mm or 100 x 65 x 130 mm (with antenna).

Simons Voss INPUT NODE is a central node that transmits remote opening or emergency activation to a lock node or directly networked cylinder by radio, replacing the switching transponder (TRA.SCHALT) and eliminating the need for wiring. It can be configured using a PC or laptop with a USB data cable, and requires a power supply unit with 230V AC / USB 5V DC controlled output. The device has a maximum transmission power of 5 dBm (3.16 mW) at the antenna socket, a sensitivity of -90 dBm at 19.2 kBaud, and operates in the 868 MHz frequency band. It features an external antenna and has dimensions of 100 x 65 x 40 mm or 100 x 65 x 130 mm (with antenna).

INPUT NODE
Correct in: September 2008
INPUT NODE
Page 2
1.0 PRODUCT NAME. _____________________________________3
1.1 ORDER CODE ____________________________________________ 3
2.0 WARNING. ___________________________________________3
2.1 SAFETY _________________________________________________ 3
2.1 FUNCTION TEST__________________________________________ 3
3.0 DESCRIPTION OF FUNCTION.___________________________4
3.1 MODE OF OPERATION_____________________________________ 4
3.2 CIRCUIT DIAGRAM________________________________________ 4
3.3 PICTURES AND REPRESENTATIONS ________________________ 4
4.0 COMMISSIONING. _____________________________________5
4.1 CONFIGURATION OF WN.CN.UR.SCHALT ____________________ 5
4.2 POWER SUPPLY: POWER SUPPLY UNIT _____________________ 6
5.0 TECHNICAL DATA. ____________________________________6
Note: SimonsVoss Technologies AG reserves the right to make modifications to the product
without notice. Consequently, descriptions and representations in this documentation may
vary from the most recent product and software versions. As a general principle, the original
German version shall apply in the event of any doubt. Subject to errors and misspellings.
© Copyright SimonsVoss Technologies AG
All rights reserved
INPUT NODE
Page 3
1.0 PRODUCT NAME.
1.1 ORDER CODE
WN.CN.UR.SCHALT, hereafter referred to as INPUT NODE.
2.0 WARNING.
2.1 SAFETY
In order to install a SimonsVoss INPUT NODE you must be familiar with access
control systems, door mechanics, door approvals, electronic assembly, and
working with SimonsVoss software. For this reason, installation should only be
undertaken by trained specialists.
SimonsVoss Technologies AG shall assume no liability for damage caused by
incorrect installation.
Access through a door may be denied if an INPUT NODE is incorrectly
installed. SimonsVoss AG shall assume no liability for the consequences of
incorrect installation, such as denied access to injured persons or persons at
risk, damage to property or any other form of damage.
ESD (electrostatic discharge) guidelines must be observed when installing the
INPUT NODE. In particular, avoid touching the PCBs and the integrated circuits
on them.
People with electronic medical implants (pacemakers, hearing aids etc.) must
always maintain a distance of at least 30 cm between the implant and the
INPUT NODE. Specific instructions should be provided to this effect.
In the interests of safety, people with electronic implants should seek medical
advice as to the potential hazards of radio units (868 MHz).
2.1 FUNCTION TEST
Perform a function test at least once per week. Make sure that all components can be
operated faultlessly.
INPUT NODE
Page 4
3.0 DESCRIPTION OF FUNCTION.
3.1 MODE OF OPERATION
The INPUT NODE can transmit either a
remote opening
or
emergency activation
to a lock node or directly networked cylinder by radio. An external switching contact
(normally open contact, see 3.2) initiates transmission of a remote opening or
emergency activation. This function replaces the switching transponder
(TRA.SCHALT), and no wiring is therefore required.
3.2 CIRCUIT DIAGRAM
3.3 PICTURES AND REPRESENTATIONS
The pictures or schematic representations used in this manual may vary in some of
their details from the devices supplied.
white = emergency activation
green = remote opening
brown = earth
USB
interface
230V/USB
Power supply (5V DC)
External
contact
(potential-free)
INPUT NODE
Page 5
4.0 COMMISSIONING.
4.1 CONFIGURATION OF WN.CN.UR.SCHALT
Connect the WN.CN.UR.SCHALT to the PC / laptop with the USB data cable.
Install USB driver; see manual for WN.CN.U(X)
Initial programming of lock with SmartCD
Network configuration; see system manual
Network Æ Activation of lock Æ Remote opening
Enter locking plan password and click on “Execute”
After executing, the INPUT NODE is fully configured
Perform function test using the switching contacts provided!!!
INPUT NODE
Page 6
4.2 POWER SUPPLY: POWER SUPPLY UNIT
Remove USB data cable
Connect supplied plug-in power supply (230V / USB 5V DC controlled)
Left LED flashes red twice
Test to make sure unit is functioning properly
5.0 TECHNICAL DATA.
Order number
WN.CN.UR.SCHALT
Description WaveNet central node with 868 MHz radio
interface and external antenna
Dimensions (L*W*H) 100 x 65 x 40 mm or
100 x 65 x 130 mm (with antenna)
Power supply Power supply unit, 230V AC / USB 5V DC,
controlled
Output Min. 3 VA (250 mA with continuous load)
Maximum
transmission power
5 dBm (3.16 mW) at antenna socket
Sensitivity -90 dBm at 19.2 kBaud
Frequency band 868 MHz
Power consumption in receiver mode 12 mA at 9 V
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Simons Voss INPUT NODE User manual

Type
User manual

Simons Voss INPUT NODE is a central node that transmits remote opening or emergency activation to a lock node or directly networked cylinder by radio, replacing the switching transponder (TRA.SCHALT) and eliminating the need for wiring. It can be configured using a PC or laptop with a USB data cable, and requires a power supply unit with 230V AC / USB 5V DC controlled output. The device has a maximum transmission power of 5 dBm (3.16 mW) at the antenna socket, a sensitivity of -90 dBm at 19.2 kBaud, and operates in the 868 MHz frequency band. It features an external antenna and has dimensions of 100 x 65 x 40 mm or 100 x 65 x 130 mm (with antenna).

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI