IA64 Console Environment
1A06
DECUS-München Bonn
20.4.2004
John R. Covert
Paul A. Jacobi
Hewlett-Packard
OpenVMS Systems Group
page 24/22/04
RX2600 consoles
Three console interfaces on the
RX2600
Extensible Firmware Interface (EFI)
Remote Console interfaces
Baseboard Management Controller (BMC)
Management Processor (MP)
page 34/22/04
RX2600 consoles
Extensible Firmware Interface (EFI)
console
EFI is the standard console for all IA64 systems,
regardless of hardware vendor
Each vendor can provide unique customizations
Used to boot the system
Interfaces with the operation system via PAL, SAL and
EFI runtime services
Provides both a menu and command line interface
Code is stored in flash ROM and optional FAT partition
EFI console is an open programming environment
Intel publishes the source code and tool kit
Intel transitioning EFI to SIG group, similar to PCI
SIG
EFI will eventfully replace BIOS on IA32 systems
page 44/22/04
RX2600 consoles
VMS_LOADER.EFI
EFI application, built using MS Visual Studio with:
IA-64 cross compilers
EFI tool kit provided my Intel
MS linker produces P/COFF image format
Runs in Physical Address mode as a console command
Implements functionality of SRM BOOT command:
Initializes HWRPB structure
Creates bootstrap Virtual Address using translation
registers
Loads IPB.EXE (ELF-format image)
Shuts down the EFI console with ExitBootServices()
Transfers to IPB in Virtual Address mode, via RFI
instruction
page 54/22/04
RX2600 consoles
Hybrid Disk Format
EFI requires GUID Partition Table (GPT) disk format
EFI requires one FAT32 partition
VMS requires ODS Files-11 disk format
VMS does not support partition disks
Both format co-exist, independent of each other
EFI console view
GPT format with one 48Mb FAT32 partition
Remaining space unallocated
VMS view
ODS Files-11 format disk
48Mb container file allocated for FAT32 partition
CD-ROMs use ISO9660 format instead of GPT
page 64/22/04
RX2600 consoles
Selecting EFI console terminal
New systems are shipped with multiple devices
selected as the console terminal
VMS requires only one serial port for the console
terminal
Be sure USB keyboard is unplugged for now,
support for USB keyboard and VGA console
planned for the future
Use the Boot Option Maintenance Menu to select
only serial port and deselect other device
Can select ANSI, VT100 and VT100+ terminal types,
based on your terminal emulator
Reset the system
page 74/22/04
RX2600 consoles
Booting VMS from the EFI Shell
Select EFI Shell from the boot menu
Set Boot flags environment variable, stored in
NVRAM
IA64 flag values are generally the same as Alpha
and VAX
Shell> set vms_flags “0,0”
Select disk and directory
Shell> fs0:
fs0:> cd efi\vms
Start the boot of VMS
fs0:> vms_loader
Override environment variable
fs0:> vms_loader –flags 0,1
page 84/22/04
RX2600 consoles
What’s wrong with the Backspace
key?
EFI console requires ^H (ASCII 0x08) for backspace
VMS traditionally uses DEL (ASCII 0x7F) for backspace
Two methods for using the backspace key
Set terminal emulator to send DEL for backspace key
Use ^H in EFI Shell and Backspace key in VMS
Set terminal emulator to always send ^H for backspace
key
Available in upcoming VMS for IA64 and Alpha
In LOGIN.COM:
$ SET TERM/BACKSPACE=DELETE
Backspace key sends ^H and works for EFI Shell and
VMS
Use ^V ^H ^H for beginning of line
page 94/22/04
RX2600 consoles
Booting VMS from the EFI menu
Create new menu item
Select Boot Option Maintenance Menu
Select Add Boot Option
Select volume
Select efi\vms\vms_loader
Add name, “HP OpenVMS Industry Standard 64”
No boot options are needed, since it uses
VMS_FLAGS stored in NVRAM
Save settings to NVRAM
page 104/22/04
RX2600 consoles
Boot Example
EFI version 1.10 [14.61]
EFI64 Running on Intel(R) Itanium Processor Family
EFI 1.10 IPF zx6000/rx2600/zx2000 1.22 [Wed Jul 23 16:43:12 2003] - HP
Copyright (c) 2000-2002 Broadcom Corporation
Broadcom NetXtreme Gigabit Ethernet EFI driver v3.0.7
Loading ’FPSWA’...
Loading ’lsi1030’...
Loading ’gigundi’...
2 0 0x00020B 0x0000000000000006 EFI Launching Boot Manager
Scsi(Pun0,Lun0) HP 18.2GST318406LC HP05 ( 40 MBytes/sec)
Scsi(Pun4,Lun0) HP 18.2GATLAS10K3_18_SCAHP05 ( 40 MBytes/sec)
Broadcom NetXtreme Gigabit Ethernet Adapter is detected (PCI)
EFI Boot Manager ver 1.10 [14.61] Firmware ver 2.20 [4331]
Please select a boot option
Boot VMS on DKB0
EFI Shell [Built-in]
Boot Option Maintenance Menu
System Configuration Menu
Use ^ and v to change option(s). Use Enter to select an option
page 114/22/04
RX2600 consoles
Change EFI Boot Menu order
Select Boot Option Maintenance Menu
Select Change Boot Order
Select new menu item
Use the “u” key to move it to the top of the list
Save Settings to NVRAM
EFI shell command, bcfg, command can also be
used the manage the EFI Boot menu
Note that menu item imbeds disk GUID, so
process must be repeated if you re-install VMS.
In the future, VMS installation process will
automate this task of adding EFI menu item
page 124/22/04
RX2600 consoles
Set EFI Autoboot timeout
Select Boot Option Maintenance Menu
Select Set Auto Boot TimeOut
Enter timeout value, usually 10 seconds
Select Delete/Disable TimeOut to prevent
autoboot
EFI Boot Manager ver 1.10 [14.61] Firmware ver 2.21 [4334]
Please select a boot option
HP OpenVMS Industry Standard 64
EFI Shell [Built-in]
Boot Option Maintenance Menu
System Configuration Menu
Use _ and _ to change option(s). Use Enter to select an option
Default boot selection will be booted in 10 seconds
page 134/22/04
RX2600 consoles
Other useful EFI shell commands
Create VMS-like console commands
Shell> alias dir ls
Display hardware and firmware revisions
Shell> info all
Clear MP console logs files stored in NVRAM
Shell> clearlogs
Map command display list of devices
Shell> map
Device mapping table
fs0 : Acpi(HWP0002,0)/Pci(2|0)/Ata(Primary,Master)/CDROM(Entry0)/HD(Part1,Sig00000000)
fs1 : Acpi(HWP0002,100)/Pci(1|0)/Scsi(Pun0,Lun0)/HD(Part1,Sig832C30E1)
fs2 : Acpi(HWP0002,200)/Pci(1|0)/Scsi(Pun2,Lun0)/HD(Part1,SigDDA9F5F4)
blk0 : Acpi(HWP0002,0)/Pci(2|0)/Ata(Primary,Master)
blk1 : Acpi(HWP0002,0)/Pci(2|0)/Ata(Primary,Master)/CDROM(Entry0)
blk2 : Acpi(HWP0002,0)/Pci(2|0)/Ata(Primary,Master)/CDROM(Entry0)/HD(Part1,Sig00000000)
blk3 : Acpi(HWP0002,100)/Pci(1|0)/Scsi(Pun0,Lun0)
blk4 : Acpi(HWP0002,100)/Pci(1|0)/Scsi(Pun0,Lun0)/HD(Part1,Sig832C30E1)
blk5 : Acpi(HWP0002,200)/Pci(1|0)/Scsi(Pun2,Lun0)
blk6 : Acpi(HWP0002,200)/Pci(1|0)/Scsi(Pun2,Lun0)/HD(Part1,SigDDA9F5F4)
page 144/22/04
RX2600 consoles
VMS_SHOW
For the 8.2 release , VMS will distribute a utility to
associate VMS device name with EFI pathnames
fs0:\efi\vms> vms_show devices
VMS: EIA0
EFI: Acpi(000222F0,0)/Pci(3|0)/Mac(00306E3829B5)
VMS: DKA0
EFI: fs0: Acpi(000222F0,100)/Pci(1|0)/Scsi(Pun0,Lun0)
VMS: EWA0
EFI: Acpi(000222F0,100)/Pci(2|0)/Mac(00306E38B938)
VMS: DKC200
EFI: fs1: Acpi(000222F0,200)/Pci(1|0)/Scsi(Pun2,Lun0)
page 154/22/04
RX2600 consoles
VMS_SET
In the 8.2 release VMS_SET utility will allow selection
of dump devices and HLL debugger port:
fs0:\efi\vms> vms_set dump_dev dka0,dkc200
VMS: DKA0
EFI: fs0: Acpi(000222F0,100)/Pci(1|0)/Scsi(Pun0,Lun0)
VMS: DKC200
EFI: fs1: Acpi(000222F0,200)/Pci(1|0)/Scsi(Pun2,Lun0)
fs0:\efi\vms> vms_show dump_dev
VMS: DKA0
EFI: fs0: Acpi(000222F0,100)/Pci(1|0)/Scsi(Pun0,Lun0)
VMS: DKC200
EFI: fs1: Acpi(000222F0,200)/Pci(1|0)/Scsi(Pun2,Lun0)
page 164/22/04
RX2600 consoles
EFI commands
page 174/22/04
RX2600 consoles
Updating the EFI firmware
Download firmware update program from HP
website onto a local system.
Minimum EFI firmware for VMS is 2.20
Startup TCP/IP in the EFI console
Shell> load fs0:\efi\vms\tools\tcpipv4.efi
Shell> \efi\vms\tools\ifconfig lo0 inet 127.0.0.1 up
Shell> \efi\vms\tools\ifconfig sni0 inet 1.1.1.1 netmask 2.2.2.2 up
Shell> \efi\vms\tools\route add default 3.3.3.3
Must be customized for your network
environment
Replace 1.1.1.1 with IP address
Replace 2.2.2.2 with Netmask
Replace 3.3.3.3 with Gateway
Hint: Use a script file to perform this task
page 184/22/04
RX2600 consoles
Obtaining EFI firmware update
Use FTP to copy over firmware update program
Shell> ftp 4.4.4.4
Connected to 4.4.4.4
220 foo.bar.com FTP Server (Version 5.3) Ready.
Name (4.4.4.4): HUBER
331 Username HUBER requires a Password
Password:
230 User logged in.
Remote system type is VMS.
ftp> bin
ftp> get fwupdate220.efi
ftp> bye
page 194/22/04
RX2600 consoles
Installing the EFI firmware update
Execute the firmware update program
Shell> fwupdate220
Warning: Do not power-off the system while
flash ROM update is in progress
Alternate update method
Download ISO file, Burn CD-ROM and execute
update program from CD-ROM
page 204/22/04
RX2600 consoles
Remote Console Interface
Independent support system
Available when the system is connected to a
power source, even if the main power switch is
set to “off”
Vendor and system-specific functionality
Two different remote consoles for the RX2600
Baseboard Management Controller (BMC) with
basic functionality
Management Process (MP) with more extensive
features
Optional on RX2600, standard on larger system
(RX4640)
page 214/22/04
RX2600 consoles
Baseboard Management Controller
(BMC)
Available only on COM1 serial port of RX2600, ZX200, ZX6000
Has it’s own processor
Password protected
Entered by “ESC (“ and exited by “ESC )” or “ESC Q”
Power ON/OFF and system reset
TOC command can be used to force a crash on hung system
cli>help
CLI Commands:
C [<passwordstring>] - Change Password
CON - Display Console selection
FPL - Read Forward Progress Log
H - Help (this text)
INFO - Display BMC FW Revision
LOC [0,1] - Locator LED Control
P [0,1] - Power Control
Q - Quit/Logout
RS [s] - Reset System [and switch to sys console]
SE - Read System Event Log
TOC [s] - Send an INIT/TOC [and switch to sys console]
page 224/22/04
RX2600 consoles
Management Processor (MP)
Optional on RX2600, standard on RX4640 and up
Minimum MP firmware for VMS is E2.22
Uses it own processor with private ethernet adapter
Username/Password protected
Snoop EFI serial line and send out characters over
serial line, TELNET or WWW (requires IP address)
Supports multiple session, but only one controls
input
^B used to enter remote console
Can control power and reset system
TC command can force a crash dump
All console terminal I/O stored in NVRAM
page 234/22/04
RX2600 consoles
MP Command Set
page 244/22/04
RX2600 consoles
Forcing a system crash
History
On VAX and early Alpha system, ^P was detected by
special hardware and handled by the console
Commodity serial ports pushed ^P detection in
console firmware, if IPL < DEVICE_IPL
EFI console ignores ^P, no way to return to EFI Shell
IA64 VMS console terminal driver handles ^P
Calls XDELTA, if loaded
Prompts for forced crash, if IPL < DEVICE_IPL
Remote console command generates Transfer of
Control signal (BMC:TOC, MP:TC)
Handled by IA64 VMS as a non-maskable exception
and results in a crash dump regardless of IPL
page 254/22/04
RX2600 consoles
Future bootstrap options
Fibre Channel
Similar to SCSI boot, but new vendor-specific setup
program to replaces the common SRM WIDMGR tool
Network boot
Uses PXE (pixie) instead of MOP
LAD/LAST booting scheduled for 8.2
Cluster NISCS boot is post 8.2
Partition system support for Superdome
VMS demo on Hard partition, Galaxy support in the
future
Memory disk boot under investigation
Use container file to eliminate boot drivers
Used by HP-UX and Linux and VAX/VMS to boot TK50
page 264/22/04
RX2600 consoles
Links
Handout: “Console Commands for the HP
Integrity Server systems”-
CONSOLE_INTERFACE.DOC
RX2600 Firmware updates:
http://h20000.www2.hp.com/bizsupport/TechSupp
ort/DriverDownload.jsp?pnameOID=88839&locale=
en_US&taskId=135&prodTypeId=15351&prodSeriesI
d=88837&submit.y=5&submit.x=8&cc=us&swEnvOID=
54
RX2600 support Manual
http://h200001.www2.hp.com/bc/docs/support/SupportMa
nual/lpn04096/lpn04096.pdf
Version 1.2 Page 1 4/22/04
Console Commands for the HP
Integrity Server Systems
© Copyright 2003 Hewlett-Packard Development Company, L.P.
Version 1.2 Page 2 4/22/04
Version 1.2 Page 3 4/22/04
Introduction ............................................................................................................................................................ 5
Ctrl/H and the Delete Key ................................................................................................................................. 5
Console Input, Output, and Error ...................................................................................................................... 5
Setting the Console Device.......................................................................................................................... 6
Console Comparison.......................................................................................................................................... 9
BMC Console................................................................................................................................................. 9
MP Console.................................................................................................................................................... 9
BMC System Console.......................................................................................................................................... 10
Entering Console Mode ................................................................................................................................... 10
Exiting Console Mode ..................................................................................................................................... 10
Command Summary ........................................................................................................................................ 10
Powering System On/Off from the BMC........................................................................................................ 11
Booting OpenVMS from the BMC ................................................................................................................. 11
Forcing a Crash ................................................................................................................................................ 12
Management Processor Console.......................................................................................................................... 13
Accessing the Management Processor ............................................................................................................ 14
Interacting with the Management Processor ......................................................................................... 14
Management Processor Command Interface .................................................................................................. 14
Management Processor Commands ................................................................................................................ 15
Reset BMC Passwords............................................................................................................................... 16
Configure Serial Port Parameters ........................................................................................................... 16
Certificate Generate .................................................................................................................................. 16
Console Log ................................................................................................................................................ 18
Command Mode......................................................................................................................................... 18
Console ........................................................................................................................................................ 18
Connect to Service Processor ................................................................................................................... 18
Date .............................................................................................................................................................. 18
Default Configuration ............................................................................................................................... 19
Display FRUID ........................................................................................................................................... 19
Disconnect Remote or LAN Console ....................................................................................................... 19
Front Panel Process ................................................................................................................................... 19
MP Firmware Update................................................................................................................................20
Help.............................................................................................................................................................. 20
Display System ID...................................................................................................................................... 20
Inactivity Timeout...................................................................................................................................... 20
Configure LAN Console............................................................................................................................ 21
LAN Status.................................................................................................................................................. 21
Return to Main Menu................................................................................................................................21
Modem Reset .............................................................................................................................................. 21
Modem Status............................................................................................................................................. 22
Power Control ............................................................................................................................................ 22
PC: Power Control—turn system power on and off................................................................................... 22
Configure Paging ....................................................................................................................................... 22
Power Status ............................................................................................................................................... 22
PS: Power status—display the status of the power management module. ................................................ 22
Reset BMC .................................................................................................................................................. 22
Reset System ............................................................................................................................................... 23
Set Access .................................................................................................................................................... 23
Create Local Session.................................................................................................................................. 23
Display Logs................................................................................................................................................ 23
Security Options......................................................................................................................................... 24
Firmware Revision Status......................................................................................................................... 24
System Status.............................................................................................................................................. 24
Transfer Of Control .................................................................................................................................. 25
Tell ............................................................................................................................................................... 25
Version 1.2 Page 4 4/22/04
User Configuration .................................................................................................................................... 25
Virtual Front Panel.................................................................................................................................... 25
Who.............................................................................................................................................................. 25
Exit from MP.............................................................................................................................................. 26
Diagnostics .................................................................................................................................................. 26
Avoiding Command Confirmation.......................................................................................................... 26
Gaining Control of the Console................................................................................................................ 26
Management Processor Help System ...................................................................................................... 26
Powering System On/Off from the MP Console ............................................................................................ 27
Booting OpenVMS from the MP Console...................................................................................................... 30
Forcing a Crash ................................................................................................................................................ 33
Event Logs........................................................................................................................................................ 34
Updating the MP Firmware ............................................................................................................................. 35
Extensible Firmware Interface (EFI) Boot Manager .......................................................................................... 44
Extensible Firmware Interface (EFI) Boot Manager...................................................................................... 44
EFI Commands ................................................................................................................................................ 46
EFI/POSSE Commands ............................................................................................................................ 47
help command ............................................................................................................................................ 47
baud ............................................................................................................................................................. 49
boottest ........................................................................................................................................................ 49
cpuconfig ..................................................................................................................................................... 51
default.......................................................................................................................................................... 51
errdump....................................................................................................................................................... 52
info ............................................................................................................................................................... 52
lanaddress ................................................................................................................................................... 56
monarch....................................................................................................................................................... 57
pdt ................................................................................................................................................................ 57
sysmode ....................................................................................................................................................... 58
Specifying SCSI Parameters................................................................................................................................ 60
Fibre Booting Overview ...................................................................................................................................... 66
Introduction ...................................................................................................................................................... 66
Supported Hardware ........................................................................................................................................ 66
Hardware Set-up................................................................................................................................................... 66
Emulex LP9802................................................................................................................................................ 66
Installing Bootable Firmware................................................................................................................... 66
Verifying the Bootable Firmware Installation....................................................................................... 67
Configuring the Boot Devices from the Emulex Bios Utility................................................................ 67
Booting on MultiPath devices ............................................................................................................................. 70
MultiPath.......................................................................................................................................................... 70
Version 1.2 Page 5 4/22/04
Introduction
The HP Integrity Server system provides two console options: the Baseboard Management Console (BMC)
and the Management Processor (MP) console. Both consoles can be used to power-cycle the systems and
perform hardware-related operations. In addition to the low-level console functions, the Integrity Server
system has a replacement for the SRM console in the Alpha processors, Extensible Firmware Interface
(EFI). This document provides command summaries and examples of commonly used commands for both
the BMC and the MP.
Ctrl/H and the Delete Key
Unlike OpenVMS, which uses the character 0X7F DEL/RUBOUT, the BMC and the MP consoles and the
EFI environment use Ctrl/H. If you press the Delete key on a VTxxx terminal or the key you have mapped
to send 0X7F in your terminal emulator, the character is not deleted.
This occurrence has triggered a new SYSGEN parameter, TTY_DEFCHAR3, and a new SET TERMINAL
COMMAND to tell the terminal driver to re-map Ctrl/H to DEL. If you want the re-mapping to be system
wide for all terminals, you need to OR 0x10 into the current value stored in TTY_DEFCHAR3. If you
want to re-map a single terminal, issue the command:
$ set terminal/backspace=delete
Doing this allows you to change your terminal or terminal emulator to send Ctrl/H instead of DEL. When
using command-line editing, you can still return to the start of the line by pressing the F12 key on a VTxxx
terminal, or you can enter Ctrl/V Ctrl/H Ctrl/H.
If you set your terminal to re-map Ctrl/H to DEL, the driver does not perform the re-mapping operation if
the terminal is in one of the following states:
o
Terminal attribute is set to PASSALL
o Terminal attribute is set to PASTHRU
o IO$_READALL
o IO$_READPBLK
o Entering Ctrl/V tells the driver to pass the next character and skip the re-map check.
Console Input, Output, and Error
Currently, OpenVMS has two console restrictions for both the BMC and MP consoles:
1. The input, output, and error devices of these must point to a serial line console.
2. They must all be the same serial device.
If these conditions are not met you receive a warning out to the VMS_LOADER, and you may see other
errors in later parts of the boot. Additionally, you may lose output that you would normally expect to see
when booting.
Version 1.2 Page 6 4/22/04
Setting the Console Device
Step 1 Power on the system. You should initially hook up to the console line on the
management processor.
******************************************************************
Only default users are configured.
Use one of the following user/password pairs to login:
Admin/Admin
Oper/Oper
******************************************************************
MP login: Admin
MP password: *****
Hewlett-Packard Management Processor
(c) Copyright Hewlett-Packard Development Company, L.P. 1999-2003. All
Rights Reserved.
MP Host Name: kthulu
Revision E.02.22
******************************************************************
MP ACCESS IS NOT SECURE
Default MP users are currently configured and remote access is enabled.
Modify default users passwords or delete default users (see UC command)
OR
Disable all types of remote access (see SA command)
******************************************************************
MP MAIN MENU:
CO: Console
VFP: Virtual Front Panel
CM: Command Menu
CL: Console Log
SL: Show Event Logs
CSP: Connect to Service Processor
SE: Enter OS Session
HE: Main Help Menu
X: Exit Connection
MP Host Name: kthulu
MP> cm
(Use Ctrl-B to return to MP main menu.)
MP Host Name: kthulu
MP:CM> pc -on -nc
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84

HP RX2600 User manual

Category
Networking
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI