AOS U600

Air-O-Swiss AOS U600, AOS U650, AOSU600 User manual

  • Hello! I am an AI chatbot trained to assist you with the Air-O-Swiss AOS U600 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
AOS U600 / U650
17
en
Instructions for use
18
en
Foreword
CongratulationsonchoosingtheUltrasonicHumidifier
U600 / U650!
Didyouknowthatdryroomair:
• Driesoutthemucousmembranes,andalsocauses
chappedlipsandstingingeyes?
• Encouragesinfectionsandillnessesoftherespiratory
system?
• Causesweariness,tirednessandpoorconcentration?
• Stresseshouseholdpetsandhouseplants?
• Encouragestheformationofdustandtheelectrostatic
chargingoftextilesmadeofsyntheticfibers,aswellas
carpetsandplasticflooring?
• Damageswoodenfurnitureandespeciallyparquet
floors?
• Causesmusicalinstrumentstogooutoftune?
General information
Acomfortableindooratmosphereisachievedatarelative
humidityofbetween40and60%.Yourapplianceautoma-
ticallycontrolsthehumiditylevelaccordingtoyourchosen
setting.Iftheairistoodry,theunitwillautomaticallyswitch
on.Assoonasthedesiredhumiditylevelisreached,itwill
automaticallyswitchoff.
Safety instructions
• Readtheoperatinginstructionscarefullybeforeusing
theapplianceandkeeptheminasafeplaceforlater
reference.
• ConnecttheunitonlytoanACsupplywithavoltage
accordingtotheratinglabel.
• Onlyusetheapplianceindoorsandwithinthepara-
metersstatedinthetechnicalspecifications.Usingthe
applianceforapurposeforwhichitisnotintended
couldposeaserioushazardtohealthandlife.
• Childrencannotrecognizethehazardsassociatedwith
theusageofelectricalappliances.Forthisreason,
alwayssupervisechildrenwhentheyareneartheap-
pliance(image1).
• Personswhoareunfamiliarwiththeoperatingin-
structions,aswellaschildrenandpersonsunderthe
influenceofmedication,alcoholordrugsarenotper-
mittedtooperatetheappliance,orareonlypermitted
tooperateitundersupervision.
• Neverusetheapplianceifthereisanydamagetothe
applianceorcable(2),aftermalfunctionhasoccurred,
aftertheappliancehasbeendropped(3)ordamaged
inanyotherway.
• Onlyoperatetheappliancewhenitiscompletelyas-
sembled.
• Repairstoelectricalappliancesmayonlybecarriedout
byqualifiedserviceengineers(4).Improperrepairwork
canposeaconsiderablehazardtotheuser.
• Disconnecttheappliancefromthemainspowerbefore
filling/emptyingthewatertank,beforecleaning,before
assembling/dismantlingofindividualpartsandbefore
movingtheappliance.
• Donotreachinsidethenebuliserspaceduringopera-
tion.Thehighfrequencyoscillationcausesthememb-
ranetobecomehot.
• Neverpulltheplugfromthemainssocketbythecable
orwithwethands.
• Alwaysplacetheapplianceonadry,levelsurface(5).
• Donotplacetheappliancedirectlyonthefloorornext
toheating.Ifthemistcomesincontactwiththefloor
beforeithasfullyevaporated,thesurfacecouldbeda-
maged(6).Wedonotacceptanyliabilityfordamages
duetotheincorrectplacementoftheunit.
• Theunitshouldbeplacedinanelevatedposition(7),
e.g.onatable,chest,etc.
• Donotpourwaterintothemistoutletoftheappliance.
•
Donotimmergethemainbodyinwaterorotherliquids.
• Positiontheappliancewhereitcannotbeeasilykno-
ckedover(8).
• Alwaysdisconnectfromthemainspowerwhennotin
use.
• Donotrunthepowercordunderacarpetorother
objects.Positiontheappliancesothatyouwillnottrip
overthecord.
• Donotusetheapplianceinareaswherecombustible
materials,gasesorvapoursarepresent.
• Donotexposetheappliancetorain,anddonotuseit
indamplocations.
• Donotinsertforeignobjectsinthedevice.
• Donotblocktheairintakeormistoutlet.
• Donotsit,standorplaceanyheavyobjectsonthe
appliance.
• Theuseoffragances,suchasessentialoils,water
conditionersandaromaswilldamageyourappliance!
Appliancesthataredamagedbysuchadditiveswillnot
becoveredbythemanufacturer‘swarranty.
• Thehighfrequencyvibrationscannotbeheardbyhu-
mansoranimals,andarecompletelysafe.
19
en
5
1
3 6
4
82
7
9
20
en
Membrane
IonicSilverStick
®
(optional)
Description of the appliance Filling the tank
Alwaysswitchofftheappliancebeforeremoving
thewatertank.Donotreachinsidethenebuliser
spacewhiletheapplianceisrunning!
Donotoperatetheappliancewhenthewatertankisempty!
When the water reaches the minimum level, the unit swit-
chesoffautomatically.
• Makesurethattherearenoforeignobjectsinsidethe
watertank.
• Removethewatertankcapfromthetank(11).Fillthe
tankwithclean,coldtapwater(12).Closethecapof
thewatertanksecurely!Placethewatertankontothe
base(13).Donotaddanyadditivestothewater(14)!
• Inserttheplugintothepowersocketandswitchonthe
appliance(15).
Unpacking
• Carefullyremovetheunitfromitsbox.
• Removetheunitfromtheplasticbag.
• Reviewtheinformationgivenontheratingplateabout
themainssupply.
• Usetheoriginalpackagingforstoringtheapplianceif
youdonotuseitallyearround.
Putting into operation
Findtheideallocationforyourappliance:
• Donotplaceitdirectlynexttoaradiatororona
floorwithfloorheating.Themoistureofthemistcan
damagethefloorsurface(6and7)(seeSafetyIn-
structions).
• Themistoutletmustnotbepointeddirectlyatplantsor
otherobjects.Keepadistanceofatleast50cm)(10).
• Soakthedemineralisationcartridgeinabowlofwater
foratleast24hoursbeforeusingit.Thegranuleshave
toabsorbwatertoreachfullperformance.
• Onaveragethedemineralisationcartridgeshouldbe
replacedevery2–3months.Thisintervalcanbe
shorterorlongerdependingonthehardnessofyour
water.
• Readtheinstructionsunder«FillingtheTank»forfilling
thewatertank(12).
• Placethewatertankontothebase(13).
• Inserttheplugintothemainssocketandswitchon
theapplianceusingtheon/offswitch(15).
• Theappliancewillreachfullcapacityabout10to
15minutesafterbeingswitchedon.
• Makesurethatthepowercordisnotpinchedany-
where(9).Donotoperatetheapplianceifthecordis
damaged(2).
Mistoutlet(rotating)
Evaporation
chamber
Water tank
Demineralisationcartridge
Mainbody
Controlpanel
Watertankcap
Brush
Nebuliserspace
21
en
Water quality maintenance
(recommended optional accessory)
TheIonicSilverStick
®
(ISS)utilizestheantimicrobialpro-
pertyofsilverandprovidesayearofoptimumwaterquality
maintenanceinallAIR-O-SWISSandBONECOhumidifiers.
TheISSbeginsworkingassoonasitcomesintocontact
withwater–eveniftheunitisswitchedoff.TheISSis
intendedexclusivelyforuseinhumidifiers.Lookatpicture
16forthepositionoftheISSintheappliance.Donotreach
insidethenebuliserspaceduringoperation.Switchoffthe
unitfirst.
Do not use additives
Wateradditives(e.g.essentialoils,fragrances,watercon-
ditionersetc.)mustNOTbeused!Evenasmallamount
cancausedamagetothetankmaterial.Thematerialisnot
suitablefortheuseofsuchadditives.Onedropisenough
todamage the tankandrendertheappliance unusable.
Appliancesthataredamagedbysuchadditiveswillnotbe
coveredbythemanufacturer’swarranty.
14
16
10
12
11
13
R
RENT DESIRED
15
22
en
C) Operation with pre-heating
ButtonCisusedforswitchingthepre-heatingonandoff
(symbol Dlightsup).Asaresult,thewaterispre-heatedto
atemperatureof80°Cbeforeenteringthenebuliserspace.
Ittakesapprox.10to15minutesforthewaterinthebase
towarmup.Themistnowleavesthenebuliserspaceata
pleasanttemperatureof40°C.Theadvantageofthisis
thattheroomtemperaturedoesnotdropand,inaddition,it
significantlyimprovesthewaterqualitymaintenance.
D) Pre-heating Indicator
E) Empty indicator (red)
Thewaterleveliseasytosee,thankstothetransparent
watertank.Theappliancealsoalertsyouwhen thewa-
tertankisempty.Theredemptyindicatorisilluminated
(symbolE).Pleasereadthechapter«Fillingthetank»for
moreinformation.TheredsymbolEmaystayilluminated
for some seconds with a refilled tank until the base is filled
withwater.
A) On-off switch
Turningtherotaryswitchclockwiseswitchestheappliance
onandatthesametimeregulatesthemistoutputfrom
lowtohigh.
B) Hygrostat (setting the humidity level)
Thedesiredhumiditylevelcanbesetbyturningtherotary
switchclockwise.Arelativehumiditybetween40and60%
isrecommended.Youcanachievethislevelbyrotatingthe
switchuntilitisroughlyintheverticalposition.Theaccu-
racyofmeasurementis+/-5%.Theunitwillswitchoff
whenthemoisturelevelexceedsthedesiredsetting.The
appliancedoesnotswitchoffiftheswitchisturnedallthe
waytotheright.Thisactivatesthecontinuousoperation
function.
Operation U600
A
C
B
D
E
23
en
C) Timer
UsingbuttonC,theoperationtimecanbeset–adjustable
between 1 and 8 hours, or continuous operation (CO).
Symbol Gshowstheoperatingperiodthathasbeenset
(1h/2h/3h/4h/5h/6h/7h/8h/CO).Thedisplaywillautomati-
callyshowthecurrentvalueafterafewseconds.
D) Controlling mist output and Evaporator
output
ByrepeatedlypressingbuttonDyoucancontrolthemist
output.Symbol Hshowswhichofthethreelevels(low/
medium/high)youhaveselected.
E) Operation with pre-heating
ButtonEisusedforswitchingthepre-heatingonandoff
(symbol Ilightsup).Asaresult,thewaterispre-heatedto
atemperatureof80°Cbeforeenteringthenebuliserspace.
Ittakesapprox.10to15minutesforthewaterinthebase
towarmup.Themistnowleavesthenebuliserspaceata
pleasanttemperatureof40°C.Theadvantageofthisis
thattheroomtemperaturedoesnotdropand,inaddition,it
significantlyimprovesthewaterqualitymaintenance.
F) Auto/Sleep Mode
Theautomaticandsleepmodescanbeactivatedbypres-
singbuttonF.Bypressingthebuttononce,theautomatic
functionisswitchedon(symbol Jappearsonthedisplay),
maintainingtheoptimumhumiditysubjecttothetempe-
rature.Control takes place by means of output quantity
andpre-settargetvalue.Bypressingthebuttontwice,the
sleepfunctionisswitchedon(symbol Kappearsonthe
display),thetargethumidityis50–65%;theoperationtime
issetat6hours;theheatingisswitchedonandthedisplay
brightnessisautomaticallydimmed.Inaddition,theoutput
quantityisalsocontrolledsubjecttothedifferencebetween
thetargetvalueandtheactualvalue.
Thehygrostatandmistoutputsettingscannotbechanged
ineithermode.IfthebuttonsBorDarepressed,theunit
willnolongerbeinautoorsleepmode.
A) On/Off Dial and Display Dimmer
BypressingbuttonAonce,youcanswitchtheuniton.By
pressingittwice,thedimmerisswitchedonwhichauto-
matically dims the displaybrightnessandsymbol N
comeson.Whenchanginganysettingsthedisplaywillillu-
minateforafewsecondsbeforereturningtodimmermode.
BypressingbuttonAathirdtime,theunitisswitchedoff.
This button is also used to reset the cleaning indicator light
(byholdingdown).
B) Hygrostat (pre-set moisture level)
BypressingbuttonByoucansetthedesiredmoisturele-
velin%.Arelativemoistureofbetween40and60%is
recommended.Theaccuracyofmeasurementis+/-5%.
The unit will switch off when the moisture level exceeds
thedesired setting. During selection the target value is
displayed(symbol DESIRED).Thedisplaywillautomati-
callyshowthecurrenthumidityvalueafterafewseconds
(symbol CURRENT).
Operation U650 G) Timer Indicator
H) Mist Output Indicator
I) Pre-heating Indicator
J) Auto Mode Indicator
K) Sleep Mode Indicator
L) Empty indicator
Thetransparentwatertankmakesitpossibletoseethe
waterlevelwell.Furthermore,theunitshowsonthedisplay
(L)whenwatermustbeadded.
Pleasereadthechapter«Fillingthetank»formoreinforma-
tion.ThesymbolLmaystayilluminatedforsomeseconds
witharefilledtankuntilthebaseisfilledwithwater.
M) Cleaning indicator
IfsymbolMand«CLEAN»appearonthedisplay,theappli-
anceshouldbecleanedasrecommendedbythemanufac-
turer.Thissymbolcomesonautomaticallyevery2weeks,
dependingonthelevelofuse.Thedisplaycanbecancelled
bydepressingbuttonAforbetween10and15seconds.
N) Dimmer Indicator
DisplayDimmerOff
DisplayDimmerOn
For instructions see button A
CURRENT
TIME
DESIRED
A
C
D
EF
M
L
H
G
I
K
B
J N
24
en
Cleaning/Maintenance
Alwaysswitchtheapplianceoffbeforeremoving
thewatertank.Donotreachinsidethenebuliser
spacewhiletheapplianceisrunning!
• Switchofftheappliance(17)andremovetheplugfrom
themainssocket(18)beforecleaning.
• Cleanthewatertankandthenebuliserspaceregularly
onceaweek(useonlywater,withoutdetergent)(19).
• Decalcifythewaterbaseregularlyusingcommercially
availabledecalcificationagents(20).Rinseoutthe
decalcificationagentthoroughlywithplentyofwater.
• Toremovethemistoutlet(21):Twistthemistoutletto
eithertherightortheleft.Alignthearrowonthemist
outletwiththearrowontheringaroundthemistoutlet.
Pulluponthemistoutletoncethearrowsarealigned.
20
18
R
RENT DESIRED
19
17
21
25
en
Important
• Makesurethatnowatergetsintothelowerpartofthe
mainbody(22).
• Cleantheinnerpartswithasoftcloth.Neveruseany
solventsoraggressivecleaningagents(23).
• Onlyusethebrushtocleanthemembrane(24).This
shouldbedoneonceaweek.
• Changethewaterinthetankatleastonceaweek.
ACIDACID
23
22 24
26
en
allgranulesareinthecartridge(32).
•Removetheplasticcupandthepinkstyrofoampiece
fromthecartridge(33)andretainforfutureuse(the
refillresinconsistsof3refillbags)(34).
• Closethecap(35).
• Soakthedemineralisationcartridgeinabowlofwater
foratleast24hoursbeforeuse(38).Thegranuleshave
toabsorbwatertoreachfullperformance.
• Nowscrewthecartridgeontothewatertankcap(39).
Closethetankcapsecurely!Placethewatertankonto
thebase(40).
Option B: Replace the entire cartridge
• Removethewatertankfromthebaseandunscrewthe
watertankcap(25).
• Thedemineralisationcartridgeisattachedtotheinside
ofthetankcap.Unscrewthecartridgefromthecapby
turningitcounter-clockwise(26).Important:doNOT
disposeofthetankcap!
• Disposeoftheoldcartridge(36).
• Unpackthenewcartridge(37).
• Soakthenewcartridgeinabowlofwaterforatleast
24hoursbeforeuse(38).Thegranuleshavetoabsorb
watertoreachfullperformance.
• Nowscrewthecartridgeontothewatertankcap(39).
Closethetankcapsecurely!Placethewatertankonto
thebase(40).
Replacement of the demineralisation
cartridge
Alwaysswitchofftheappliancebeforeremoving
thewatertank.Donotreachinsidethenebuliser
spacewhiletheapplianceisrunning!
Thecartridgemustbereplacedevery2–3months.Ifthe
waterisveryhard,itmaybenecessarytoreplacethecart-
ridgeearlier.Whitedustaroundtheapplianceisasuresign
thatthecartridgeneedsreplacing.Ifwhiteresiduescon-
tinuestoformaroundtheapplianceafteranewcartridge
hasbeeninserted,pleasemakesurethatthewateryouare
usingisuntreated.Ifthewaterflowsthroughadomestic
decalcificationsystembeforeitisusedintheunit,saltwill
precipitatearoundtheappliance.
Option A: Replace the granules
• Removethewatertankfromthebaseandunscrewthe
watertankcap(25).
• Thedemineralisationcartridgeisattachedtotheinside
ofthecap.Unscrewthecartridgefromthecapby
turningitcounter-clockwise(26).Important:doNOT
disposeofthetankcap!
• Openthecartridge(27).
•Throwthecontent(granules)intothewaste(28).Atten-
tion!Disposedgranulescanmakethefloorslippery!
•Placetheenclosedpinkstyrofoampieceinthecenter
ofthecartridge.Donotpushittothebottomasitwill
bedifficulttoremoveafterwards(29).
•Pourthecontentsofonerefillresinbagintotheplastic
cupthatisincludedwiththerefillresinpackaging(30).
•Placetheemptycartridgewiththepluginthecenter
ontotheplasticcup(31).
•Turntheplasticcupandcartridgeoverandshakeuntil
25
26
27 28
27
en
40
39
29 30
31
32
33
34
36
38
35
37
28
en
Storing the appliance for extended periods
Cleantheapplianceasdescribedearlierandallowtodry
thoroughly.Preferablystoretheapplianceinitsoriginalbox,
inadryplaceawayfromhightemperatures.
Disposal
Return your worn out unit to your dealer for
properdisposal.Youcanobtaininformationon
otherwaystodisposeoftheunitfromyourlocal
districtortowncouncil.
Warranty
Thewarrantyconditionsaredefinedbyourrepresentative
inthecountryofsale.Pleasecontactyourdealerif,despite
strictqualitycontrol,yourappliancebecomesdefective.You
mustpresentyouroriginalreceiptwhenmakingaclaim
underthewarranty.Repairstoelectricappliancescanonly
be carried out by specialists.Through improper repairs,
considerabledangerfortheoperatorcanresultandwar-
rantyclaimslapse.
Technical specifications
Mainsvoltage 230–240V/50Hz
Powerconsumption 40 / 125–140W*
Humidityoutput 400/550g/h*
Suitableforroomsupto 60 m
2
/150m
3
Watercapacity 5.5 litres
Dimensions 280x240x355mm
Weight(empty) 4.0kg
Operatingnoiselevel <25dB(A)
Accessories Demineralisationcartridge
optional:IonicSilverStick
®
(ISS)
*whenusedwithpre-heatingto80°C
Problem Possible cause What to do
Unitdoesnotoperate Powerplugnotpluggedin Pluginpowerplugintomainssocket
Nowaterinthetank Filltankwithwater
(Emptyindicatorison)
Nomistoutput Desiredhumiditylevellower Increasehumiditysetting
than actual
Cleaningagentresidues Rinsewithclearwater
Weakmistoutput Watertemperaturetoolow Setmistoutputtomaximum.The
appliancewillworkproperlyagain
after10minutes.
Mineraldepositsonmembrane Cleanmembrane
Whitedepositaroundthe Demineralisationcartridgeexhausted Replacedemineralisationcartridgeorgranules
appliance
Troubleshooting