U7145

Boneco U7145, U7147, Ultrasonic U7145 Operating instructions

  • Hello! I am an AI chatbot trained to assist you with the Boneco U7145 Operating instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
3
Használati útmutató (77 – 88)
hu
Gebrauchsanweisung (5 – 16)
de
Instructions for use (17 – 28)
en
Instructions d’utilisation (29 – 40)
fr
it
Istruzioni per l’uso (41 – 52)
Gebruiksaanwijzing (53 – 64)
nl
es
Instrucciones para el uso (65 – 76)
Instrukcja obsługi (89 – 100)
pl
Инструкция по эксплуатации (101 – 114)
ru
se
Bruksanvisning (115 – 126)
Käyttöohje (127 – 138)
fi
dk
Brugsanvisning (139 – 150)
Bruksanvisning (151 – 162)
no
17
en
Instructions for use
18
en
Foreword
CongratulationsonchoosingtheUltrasonicHumidifier
U7145 / U7147!
Didyouknowthatdryroomair:
• Driesoutthemucousmembranes,andalsocauses
chappedlipsandstingingeyes?
• Encouragesinfectionsandillnessesoftherespiratory
system?
• Causesweariness,tirednessandpoorconcentration?
• Stresseshouseholdpetsandhouseplants?
• Encouragestheformationofdustandtheelectrostatic
chargingoftextilesmadeofsyntheticfibers,aswellas
carpetsandplasticflooring?
• Damageswoodenfurnitureandespeciallyparquet
floors?
• Causesmusicalinstrumentstogooutoftune?
General information
Acomfortableindooratmosphereisachievedatarelative
humidityofbetween40and60%.Yourapplianceautoma-
ticallycontrolsthehumiditylevelaccordingtoyourchosen
setting.Iftheairistoodry,theunitwillautomaticallyswitch
on.Assoonasthedesiredhumiditylevelisreached,itwill
automaticallyswitchoff.
Safety instructions
• Readtheoperatinginstructionscarefullybeforeusing
theapplianceandkeeptheminasafeplaceforlater
reference.
• ConnecttheunitonlytoanACsupplywithavoltage
accordingtotheratinglabel.
• Onlyusetheapplianceindoorsandwithinthepara-
metersstatedinthetechnicalspecifications.Usingthe
applianceforapurposeforwhichitisnotintended
couldposeaserioushazardtohealthandlife.
• Childrencannotrecognizethehazardsassociatedwith
theusageofelectricalappliances.Forthisreason,
alwayssupervisechildrenwhentheyareneartheap-
pliance(image1).
• Personswhoareunfamiliarwiththeoperatingin-
structions,aswellaschildrenandpersonsunderthe
influenceofmedication,alcoholordrugsarenotper-
mittedtooperatetheappliance,orareonlypermitted
tooperateitundersupervision.
• Neverusetheapplianceifthereisanydamagetothe
applianceorcable(2),aftermalfunctionhasoccurred,
aftertheappliancehasbeendropped(3)ordamaged
inanyotherway.
• Onlyoperatetheappliancewhenitiscompletelyas-
sembled.
• Repairstoelectricalappliancesmayonlybecarriedout
byqualifiedserviceengineers(4).Improperrepairwork
canposeaconsiderablehazardtotheuser.
• Disconnecttheappliancefromthemainspowerbefore
filling/emptyingthewatertank,beforecleaning,before
assembling/dismantlingofindividualpartsandbefore
movingtheappliance.
• Donotreachinsidethenebuliserspaceduringopera-
tion.Thehighfrequencyoscillationcausesthememb-
ranetobecomehot.
• Neverpulltheplugfromthemainssocketbythecable
orwithwethands.
• Alwaysplacetheapplianceonadry,levelsurface(5).
• Donotplacetheappliancedirectlyonthefloorornext
toheating.Ifthemistcomesincontactwiththefloor
beforeithasfullyevaporated,thesurfacecouldbeda-
maged(6).Wedonotacceptanyliabilityfordamages
duetotheincorrectplacementoftheunit.
• Theunitshouldbeplacedinanelevatedposition(7),
e.g.onatable,chest,etc.
• Donotpourwaterintothemistoutletoftheappliance.
•
Donotimmergethemainbodyinwaterorotherliquids.
• Positiontheappliancewhereitcannotbeeasilykno-
ckedover(8).
• Alwaysdisconnectfromthemainspowerwhennotin
use.
• Donotrunthepowercordunderacarpetorother
objects.Positiontheappliancesothatyouwillnottrip
overthecord.
• Donotusetheapplianceinareaswherecombustible
materials,gasesorvapoursarepresent.
• Donotexposetheappliancetorain,anddonotuseit
indamplocations.
• Donotinsertforeignobjectsinthedevice.
• Donotblocktheairintakeormistoutlet.
• Donotsit,standorplaceanyheavyobjectsonthe
appliance.
• Theuseoffragances,suchasessentialoils,water
conditionersandaromaswilldamageyourappliance!
Appliancesthataredamagedbysuchadditiveswillnot
becoveredbythemanufacturer‘swarranty.
• Thehighfrequencyvibrationscannotbeheardbyhu-
mansoranimals,andarecompletelysafe.
20
en
Description of the appliance
Membrane
Mistoutlet(rotating)
Evaporation
chamber
Water tank
Brush
Demineralisationcartridge
Mainbody
Controlpanel
Watertankcap
Nebuliserspace
Filling the tank
Alwaysswitchofftheappliancebeforeremoving
thewatertank.Donotreachinsidethenebuliser
spacewhiletheapplianceisrunning!
Donotoperatetheappliancewhenthewatertankisempty!
When the water reaches the minimum level, the unit swit-
chesoffautomatically.
• Makesurethattherearenoforeignobjectsinsidethe
watertank.
• Removethewatertankcapfromthetank(11).Fillthe
tankwithclean,coldtapwater(12).Closethecapof
thewatertanksecurely!Placethewatertankontothe
base(13).Donotaddanyadditivestothewater(14)!
• Inserttheplugintothepowersocketandswitchonthe
appliance(15).
Unpacking
• Carefullyremovetheunitfromitsbox.
• Removetheunitfromtheplasticbag.
• Reviewtheinformationgivenontheratingplateabout
themainssupply.
• Usetheoriginalpackagingforstoringtheapplianceif
youdonotuseitallyearround.
Putting into operation
Findtheideallocationforyourappliance:
• Donotplaceitdirectlynexttoaradiatororona
floorwithfloorheating.Themoistureofthemistcan
damagethefloorsurface(6and7)(seeSafetyIn-
structions).
• Themistoutletmustnotbepointeddirectlyatplantsor
otherobjects.Keepadistanceofatleast50cm)(10).
• Soakthedemineralisationcartridgeinabowlofwater
foratleast24hoursbeforeusingit.Thegranuleshave
toabsorbwatertoreachfullperformance.
• Onaveragethedemineralisationcartridgeshouldbe
replacedevery2–3months.Thisintervalcanbe
shorterorlongerdependingonthehardnessofyour
water.
• Readtheinstructionsunder«FillingtheTank»forfilling
thewatertank(12).
• Placethewatertankontothebase(13).
• Inserttheplugintothemainssocketandswitchon
theapplianceusingtheon/offswitch(15).
• Theappliancewillreachfullcapacityabout10to
15minutesafterbeingswitchedon.
• Makesurethatthepowercordisnotpinchedany-
where(9).Donotoperatetheapplianceifthecordis
damaged(2).
IonicSilverStick
®
(optional)
21
en
Water quality maintenance
(recommended optional accessory)
TheIonicSilverStick
®
(ISS)utilizestheantimicrobialpro-
pertyofsilverandprovidesayearofoptimumwaterquality
maintenanceinallAIR-O-SWISSandBONECOhumidifiers.
TheISSbeginsworkingassoonasitcomesintocontact
withwatereveniftheunitisswitchedoff.TheISSis
intendedexclusivelyforuseinhumidifiers.Lookatpicture
16forthepositionoftheISSintheappliance.Donotreach
insidethenebuliserspaceduringoperation.Switchoffthe
unitfirst.
Do not use additives
Wateradditives(e.g.essentialoils,fragrances,watercon-
ditionersetc.)mustNOTbeused!Evenasmallamount
cancausedamagetothetankmaterial.Thematerialisnot
suitablefortheuseofsuchadditives.Onedropisenough
todamage the tank and render theappliance unusable.
Appliancesthataredamagedbysuchadditiveswillnotbe
coveredbythemanufacturer’swarranty.
14
10
12
11
13
15 16
22
en
C) Empty indicator (red)
Thewaterleveliseasytosee,thankstothetransparent
watertank.Theappliancealsoalertsyouwhenthewa-
tertankisempty.Theredemptyindicatorisilluminated
(symbolC).Pleasereadthechapter«Fillingthetank»for
moreinformation.TheredsymbolCmaystayilluminated
for some seconds with a refilled tank until the base is filled
withwater.
A) On-off switch
Turningtherotaryswitchclockwiseswitchestheappliance
onandatthesametimeregulatesthemistoutputfrom
lowtohigh.
B) Hygrostat (setting the humidity level)
Thedesiredhumiditylevelcanbesetbyturningtherotary
switchclockwise.Arelativehumiditybetween40and60%
isrecommended.Youcanachievethislevelbyrotatingthe
switchuntilitisroughlyintheverticalposition.Theaccu-
racyofmeasurementis+/-5%.Theunitwillswitchoff
whenthemoisturelevelexceedsthedesiredsetting.The
appliancedoesnotswitchoffiftheswitchisturnedallthe
waytotheright.Thisactivatesthecontinuousoperation
function.
Operation U7145
A
B
C
23
en
D) Controlling mist output and Evaporator
output
ByrepeatedlypressingbuttonDyoucancontrolthemist
output.Symbol Hshowswhichof thethreelevels (low/
medium/high)youhaveselected.
E) Operation with pre-heating
ButtonEisusedforswitchingthepre-heatingonandoff
(symbol Ilightsup).Asaresult,thewaterispre-heatedto
atemperatureof80°Cbeforeenteringthenebuliserspace.
Ittakesapprox.10to15minutesforthewaterinthebase
towarmup.Themistnowleavesthenebuliserspaceata
pleasanttemperatureof40°C.Theadvantageofthisis
thattheroomtemperaturedoesnotdropand,inaddition,it
significantlyimprovesthewaterqualitymaintenance.
F) Auto/Sleep Mode
Theautomaticandsleepmodescanbeactivatedbypres-
singbuttonF.Bypressingthebuttononce,theautomatic
functionisswitchedon(symbol Jappearsonthedisplay),
maintainingtheoptimumhumiditysubjecttothetempera-
ture.Controltakesplacebymeansofoutputquantityand
pre-settargetvalue.Ifthesleepfunctionisswitchedon
(thesymbol Kappearsonthedisplay),thetargethumidity
is50–65%;theoperationtimeisautomaticallysetat6
hours;theheatingisswitchedon.Inaddition,theoutput
quantityisalsocontrolledsubjecttothedifferencebetween
thetargetvalueandtheactualvalue.
Thehygrostatandmistoutputsettingscannotbechanged
ineithermode.IfthebuttonsBorDarepressed,theunit
willnolongerbeinautoorsleepmode.
G) Timer Indicator
H) Mist Output Indicator
A) Switching on/off
YoucanswitchtheunitonoroffbypressingbuttonA.This
buttonisalsousedtoresetthecleaningindicatorlight(by
holdingdown).
B) Hygrostat (pre-set moisture level)
BypressingbuttonByoucansetthedesiredmoisturele-
velin%.Arelativemoistureofbetween40and60%is
recommended.Theaccuracyofmeasurementis+/-5%.
The unit will switch off when the moisture level exceeds
thedesired setting. During selection the target valueis
displayed(symbol DESIRED).Thedisplaywillautomati-
callyshowthecurrenthumidityvalueafterafewseconds
(symbol CURRENT).
C) Timer
UsingbuttonC,theoperationtimecanbeset–adjustable
between 1 and 8 hours, or continuous operation (CO).
Symbol Gshowstheoperatingperiodthathasbeenset
(1h/2h/3h/4h/5h/6h/7h/8h/CO).Thedisplaywillautomati-
callyshowthecurrentvalueafterafewseconds.
Operation U7147 I) Pre-heating Indicator
J) Auto Mode Indicator
K) Sleep Mode Indicator
L) Empty indicator
Thetransparentwatertankmakesitpossibletoseethe
waterlevelwell.Furthermore,theunitshowsonthedisplay
(L)whenwatermustbeadded.
Pleasereadthechapter«Fillingthetank»formoreinforma-
tion.ThesymbolLmaystayilluminatedforsomeseconds
witharefilledtankuntilthebaseisfilledwithwater.
M) Cleaning indicator
IfsymbolMand«CLEAN»appearonthedisplay,theappli-
anceshouldbecleanedasrecommendedbythemanufac-
turer.Thissymbolcomesonautomaticallyevery2weeks,
dependingonthelevelofuse.Thedisplaycanbecancelled
bydepressingbuttonAforbetween10and15seconds.
D
E
F
H
I
J
L
A
B
C
G
K
M
24
en
Cleaning/Maintenance
Alwaysswitchtheapplianceoffbeforeremoving
thewatertank.Donotreachinsidethenebuliser
spacewhiletheapplianceisrunning!
• Switchofftheappliance(17)andremovetheplugfrom
themainssocket(18)beforecleaning.
• Cleanthewatertankandthenebuliserspaceregularly
onceaweek(useonlywater,withoutdetergent)(19).
• Decalcifythewaterbaseregularlyusingcommercially
availabledecalcificationagents(20).Rinseoutthe
decalcificationagentthoroughlywithplentyofwater.
• Toremovethemistoutlet(21):Twistthemistoutletto
eithertherightortheleft.Alignthearrowonthemist
outletwiththearrowontheringaroundthemistoutlet.
Pulluponthemistoutletoncethearrowsarealigned.
20
19
21
17
18
25
en
Important
• Makesurethatnowatergetsintothelowerpartofthe
mainbody(22).
• Cleantheinnerpartswithasoftcloth.Neveruseany
solventsoraggressivecleaningagents(23).
• Onlyusethebrushtocleanthemembrane(24).This
shouldbedoneonceaweek.
• Changethewaterinthetankatleastonceaweek.
23
22 24
26
en
allgranulesareinthecartridge(32).
•Removetheplasticcupandthepinkstyrofoampiece
fromthecartridge(33)andretainforfutureuse(the
refillresinconsistsof3refillbags)(34).
• Closethecap(35).
• Soakthedemineralisationcartridgeinabowlofwater
foratleast24hoursbeforeuse(38).Thegranuleshave
toabsorbwatertoreachfullperformance.
• Nowscrewthecartridgeontothewatertankcap(39).
Closethetankcapsecurely!Placethewatertankonto
thebase(40).
Option B: Replace the entire cartridge
• Removethewatertankfromthebaseandunscrewthe
watertankcap(25).
• Thedemineralisationcartridgeisattachedtotheinside
ofthetankcap.Unscrewthecartridgefromthecapby
turningitcounter-clockwise(26).Important:doNOT
disposeofthetankcap!
• Disposeoftheoldcartridge(36).
• Unpackthenewcartridge(37).
• Soakthenewcartridgeinabowlofwaterforatleast
24hoursbeforeuse(38).Thegranuleshavetoabsorb
watertoreachfullperformance.
• Nowscrewthecartridgeontothewatertankcap(39).
Closethetankcapsecurely!Placethewatertankonto
thebase(40).
Replacement of the demineralisation
cartridge
Alwaysswitchofftheappliancebeforeremoving
thewatertank.Donotreachinsidethenebuliser
spacewhiletheapplianceisrunning!
Thecartridgemustbereplacedevery2–3months.Ifthe
waterisveryhard,itmaybenecessarytoreplacethecart-
ridgeearlier.Whitedustaroundtheapplianceisasuresign
thatthecartridgeneedsreplacing.Ifwhiteresiduescon-
tinuestoformaroundtheapplianceafteranewcartridge
hasbeeninserted,pleasemakesurethatthewateryouare
usingisuntreated.Ifthewaterflowsthroughadomestic
decalcificationsystembeforeitisusedintheunit,saltwill
precipitatearoundtheappliance.
Option A: Replace the granules
• Removethewatertankfromthebaseandunscrewthe
watertankcap(25).
• Thedemineralisationcartridgeisattachedtotheinside
ofthecap.Unscrewthecartridgefromthecapby
turningitcounter-clockwise(26).Important:doNOT
disposeofthetankcap!
• Openthecartridge(27).
•Throwthecontent(granules)intothewaste(28).Atten-
tion!Disposedgranulescanmakethefloorslippery!
•Placetheenclosedpinkstyrofoampieceinthecenter
ofthecartridge.Donotpushittothebottomasitwill
bedifficulttoremoveafterwards(29).
•Pourthecontentsofonerefillresinbagintotheplastic
cupthatisincludedwiththerefillresinpackaging(30).
•Placetheemptycartridgewiththepluginthecenter
ontotheplasticcup(31).
•Turntheplasticcupandcartridgeoverandshakeuntil
25
26
27 28
28
en
Storing the appliance for extended periods
Cleantheapplianceasdescribedearlierandallowtodry
thoroughly.Preferablystoretheapplianceinitsoriginalbox,
inadryplaceawayfromhightemperatures.
Disposal
Return your worn out unit to your dealer for
properdisposal.Youcanobtaininformationon
otherwaystodisposeoftheunitfromyourlocal
districtortowncouncil.
Warranty
Thewarrantyconditionsaredefinedbyourrepresentative
inthecountryofsale.Pleasecontactyourdealerif,despite
strictqualitycontrol,yourappliancebecomesdefective.You
mustpresentyouroriginalreceiptwhenmakingaclaim
underthewarranty.Repairstoelectricappliancescanonly
be carried out by specialists. Through improper repairs,
considerabledangerfortheoperatorcanresultandwar-
rantyclaimslapse.
Technical specifications U7145
Mainsvoltage 230–240 V / 50 Hz
Powerconsumption 45 W
Humidityoutput 400g/h
Suitableforroomsupto 60 m
2
/ 150 m
3
Watercapacity 5.0litres
Dimensions 240x260x310mm
Weight(empty) 3.0kg
Operatingnoiselevel <25dB(A)
Accessories Demineralisationcartridge
optional:IonicSilverStick
®
(ISS)
Technical specifications U7147
Mainsvoltage 230–240V/50Hz
Powerconsumption 40 / 125–140W*
Humidityoutput 400/550g/h*
Suitableforroomsupto 60 m
2
/ 150 m
3
Watercapacity 5.0 litres
Dimensions 240x260x310mm
Weight(empty) 3.0kg
Operatingnoiselevel <25dB(A)
Accessories Demineralisationcartridge
optional:IonicSilverStick
®
(ISS)
*whenusedwithpre-heatingto80°C
Problem Possible cause What to do
Unitdoesnotoperate Powerplugnotpluggedin Pluginpowerplugintomainssocket
Nowaterinthetank Filltankwithwater
(Emptyindicatorison)
Nomistoutput Desiredhumiditylevellower Increasehumiditysetting
than actual
Cleaningagentresidues Rinsewithclearwater
Weakmistoutput Watertemperaturetoolow Setmistoutputtomaximum.The
appliancewillworkproperlyagain
after10minutes.
Mineraldepositsonmembrane Cleanmembrane
Whitedepositaroundthe Demineralisationcartridgeexhausted Replacedemineralisationcartridgeorgranules
appliance
Troubleshooting
AIR-O-SWISS and BONECO are registered trademarks of PLASTON Group, Switzerland