INSTALLATION DATA
41-411 HOT SURFACE FURNACE
IGNITOR EXACT REPLACEMENT
RHEEM 62-22868-82 / 62-22441-01
The Robertshaw® 41-400 Series Hot Surface lgnitors deliver
dependable ignion in heang systems of every descripon.
from furnaces and boilers to roof top heaters, infrared burners,
unit heaters, water heaters, and many other types of HVAC
equipment.
The 41-411 is specically designed to replace Rheem part
number 62-22868-82, and 62-22441-01.
The 41-400 Series Hot Surface lgnitors are made of high-pu-
rity recrystallized silicon carbide (Crystar )which combines
physical and thermal strength with stable electrical properes.
The 41-400 Series are designed to reach ignion temperature(s)
within 17 seconds. They have 18-gauge nickel chrome lead
wires embedded and metalized in place for maximum holding
strength and electrical conducvity. The lead wires are also
enclosed with a special high-temperature ber glass insulaon
providing total electrical protecon.
CAUTION: THIS DEVICE SHOULD BE INSTALLED BY A
QUALIFIED TECH NICIAN WITH DUE REGARD FOR
SAFETY AS IMPROPER IN STALLATION COULD RESULT IN
A HAZARDOUS CONDITION.
Hot surface ignitors get hot! up to 2500°F.
Therefore wait several minutes allowing the
ignitor to cool down, before aempng any
service work. Failure to do so will cause severe
personal injury.
Turn o all gas and electrical power to the
equipment being serviced. Failure to do so can
cause severe injury, death or property damage.
1. Locate model number of the furnace rang plate then nd it
in the chart below.
2. Refer to gure 1 and then 2 or 3 as directed on back page,
when installing new ignitor.
3. Remove old ignitor from furnace. Save all mounng
hardware.
4. To install new ignitor bracket refer to gure 2 or 3 on back
page.
5. Installaon is now complete, put system back in service and
let it run through two or three start-ups to verify proper
operaon.
WARNING
CAUTION
FURNACE MODEL FIGURE NO. FURNACE MODEL FIGURE NO. FURNACE MODEL FIGURE NO.
RHEEM/RUDD HEAT CONTROLLER CENTER ENVIRONMENTAL
SYSTEM
GDA 3 GAD 3 P-UXD 3
GDB 3 GAU 3
GDD 3 GSD 3 WEATHERKING
GDE 2 GSU 3 GDW 3
GEB 3 GYDA 2 GDWE 3
GKA 3 GYUA 2 GDWHC 3
GLA 3 GZD 3 GDWHE 2
GLB 3 GZU 3 GHCA 2
GLD 3 GHID 2
GLE 2 NORDYNE GHST 2
GUH 2 RFYDC 3 GUW 3
GUJ 2 RFYDD 2 GUWE 3
GVC 2 RFYUA 3 GUWHC 3
GWH 2 RFYUC 3 GUWHE 2
GYC 2 RFYUD 2
NOTE: On models GDG, GLG, GVG, WGDAG, WGLAG, WGVAG, use the exisng bracket not the new bracket.
www.Uni-Line.com
www.Robertshaw.com
©2014 Robertshaw
07/14 – 1-867 RevB
INSTALLATION INSTRUCTIONS
Customer Service Telephone 1.800.304.6563
Customer Service Facsimile 1.800.426.0804
Robertshaw®, Ranco®, Paragon® and Uni-Line® are
trademarks of Robertshaw its subsidiaries and/or
affiliated companies. All other brands mentioned
may be the trademarks of their respective owners.
For Technical Service
Telephone 1.800.445.8299
Facsimile 1.630.260.7294
  • Page 1 1
  • Page 2 2

Robertshaw 41-411 Hot Surface Furnace Ignitor Exact Replacement Rheem 62-22868-82 / 62-22441-01 User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI