DL-500-TB
Accessories
Copyright © Gianni Industries, Inc. All rights reserved.
P-MU-DL-500-TB Published: 2015.07.14
5x50 Wooden
screws x 4
Shim x4
Power Transfer Door Loop
(With Plug-in Terminal Block)
Installation Instructions
【Suitable for woorden door
frames with round drilling holes】
ಏҜ;mm
1.
1.
1.
3
4
24.2
24.8
292
300
280
276
1
Measure the dimension
and depth of DL-500-TB
as per diagram on the left
and mark on the frame.
Pen
Ruler
2
Electric Drill
Drill holes in the marked
positions on the door and
frame to the deepest depth
and trim with the chisel.
Chisel
Wire
Shim x4
5x50 Wooden
screws x4
Wire
Wire
Make sure the DL-500-TB is completely embedded into
the door and frame.
Place the shim behind the DL-500-TB case. Connect the
wires to the terminal block located on the both ends of
DL-500-TB and test the unit .
Use 5x50 wooden screws to secure the unit and fix tightly
with the front locking piece.
Unit: mm
2.
2..
2.
Terminal Block Wiring Diagram
2 Green
Blocks
3 Blue
Blocks
3 Green
Blocks
78
J2 J3 J4
6
7
8
123456
J1
1
2
3
4
5
Grey
White
Orange
Yellow
Green
Blue
Red +
NC
COM
NO
NC
COM
NO
1
2
3
4
5
6
7
8
Black -
Grey
White
Orange
Yellow
Green
Blue
Red
+
NC
COM
NO
NC
COM
NO
1
2
3
4
5
6
7
8
Black
-
2
3
3
Wire Terminal Block
Green
Blocks
Blue
Blocks
Green
Blocks
Installation Steps
3.
3.
3.
Door Opening Angle &
Max 30mm
Max 30mm
1
1
0
°
Installaiotn Distance
4.
4.
4.
Concealed Door Loop
Installation
Note:
Wire color numbers match terminal block
numbers, and the terminal blocks on both
sides are labeled with the same number.
For each side, the Red wire 1 is connected
to the terminal 1 of the Green Block, the
Black wire 2 is connected to the terminal 2
of the Green Block, and so on.
35