USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 1
SHEER 500
Owner’s Manual
MODELS:
WFS512R1 WFS524R1 WFS536R1 WFS548R1 WFS560R1
WFS512B1 WFS524B1 WFS536B1 WFS548B1 WFS560R6
WFS512R6 WFS524R6 WFS536R6 WFS548R6
WFS512B6 WFS524B6 WFS536B6 WFS548B6
IMPORTANT SAFETY INSTRUCTIONS
Basic safety precautions s
h
ou
ld
a
l
ways
b
e fo
ll
owe
d
, inc
l
u
d
ing t
h
e fo
ll
owing: Fai
l
ure to fo
ll
ow instructions
can cause severe injury and/or death.
This is the safety-alert symbol. When you see this symbol on your equipment or in this manual, look for
one of the following signal words and be alert to the potential for personal injury.
WARNING warns about hazards that could cause serious personal injury, death or major property
damage and if ignored presents a potential hazard.
CAUTION warns about hazards that will or can cause minor or moderate personal injury and/or property
damage and if ignored presents a potential hazard. It can also make consumers aware of actions that are
unpredictable and unsafe.
The NOTICE label indicates special instructions that are important but not related to hazards.
Hayward Pool Products
620 Division Street, Elizabeth, NJ 07207
Phone: (908) 355-7995
www.hayward.com
Contents
General Warnings…………………2
Installation……….……………..……4
Plumbing Connection…………….5
Dimensions……………………………6
Warranty………………………………..7
Cutting Extended Lip………………7
ISWFS126 Rev B
WA
R
follow ins
t
WA
R
Suction in
s
severe inju
Hair Entra
Limb Entr
a
cracked, m
Body Suc
t
Eviscerati
sump or s
u
disembow
e
Mechanic
opening of
WAR
o
W
b
e
a
p
o D
o D
o T
h
o N
o R
e
o I
n
g
u
o I
n
WA
R
suction o
u
WA
R
material c
a
WA
R
replaced
a
CAU
T
being use
d
on this pro
positioned
WAR
start up, n
o
follow safe
and clamp
pool and s
p
be in open
back to th
e
open filter
is dischar
g
WAR
of pump a
n
servicing p
circulation
circulation
circulatio
n
air can cau
high volu
m
R
NING
-
Re
a
ructions can
R
NING
– Suc
uction outlets
ry and/or deat
h
pment
- Hair c
a
a
pment
- A lim
b
issing, or not s
ion Entrapm
on/ Disembo
ction outlet co
e
lment.
l Entrapmen
a suction outl
NING
- To R
e
hen outlets ar
installed. Su
art, as measu
ual suction fitt
ual suction fitt
e maximum s
ever use Pool
place damag
addition two
idelines, follo
stallation of a
R
NING
Fail
u
tlets can resu
R
NING
Fail
n result in an
R
NING
Suc
t least every t
T
ION
Com
p
as means of
uct. Closely
to prevent chil
NING
– Haz
rmal operatio
ty and operati
due to pressur
a water circul
position. Befo
pool. Do not
manual air reli
ed.
NING
Sep
d/or filter com
ool and spa cir
system if a sys
system unless
system at m
se component
e blower when
USE ONL
Y
a
d and foll
o
ause severe i
tion Entrap
and/or suctio
due to the fol
n become ent
inserted into
ecurely attach
e
nt
- A negative
w
elment
- A n
e
er which is, d
t
- There is pot
e
t cover resulti
duce the ris
small enough
tion outlets in
ed from near
ngs shall be pl
ngs shall not b
y
stem flow rate
r Spa if any su
d, broken, cra
r more suction
all National,
v
acuum releas
e
re to remove
lt in an increa
ure to keep su
increase pot
tion outlet co
m
n years or if
onents such
access to the
upervise child
dren from usin
ardous Pres
, and after pu
n instructions
in the system
tion system, a
re starting sys
hange filter co
f valve. Do no
aration Haza
ponents. Strai
culation syste
tem compone
filter manual a
re than 50 PS
to explode, w
air purging th
HAYWARD G
w all inst
jury and/or d
ent Hazard.
outlet covers
lowing entrap
ngled in sucti
an opening of
d can result in
pressure appli
gative pressu
maged, broke
e
ntial for jewelr
y
g in mechanic
k of Entrapm
to be blocked
the same plan
oint to near po
aced in such l
e located on s
shall not exce
tion outlet co
ked, missing,
outlets per pu
State, and Loc
or vent syste
pressure test
e potential f
ction outlet c
ntial for sucti
ponents hav
ound to be da
as the filtrati
pool by young
en at all times
them as a m
s
ure.
Pool an
d
p shut off. St
could result in
, which could
ll system and
em pump, all s
ntrol valve pos
t close filter m
rd. Failure to
f
ner cover must
, filters manu
t is not assem
ir relief valve b
I
. Do not purg
e
th risk of seve
pump, filter,
NUINE REPL
r
uctions
in
t
eath.
hich are, da
m
ent hazards:
n outlet cover
suction outle
a mechanical
d to a large p
r
e applied dire
c
, cracked, mis
, swimsuit, ha
a
l entrapment.
ent Hazards:
by a person, a
e (i.e. floor or
int.
cations and di
ating areas or
d 6 ft/sec in t
ponent is da
o
r not securely
p installed in
l codes applic
, which reliev
plugs and/or
o
r suction entr
a
mponents cl
n entrapmen
a finite life,
maged, broke
n system, pu
m
children. To
r
.
Components
s
ans of access
spa water circ
nd clear of cir
violent separa
ause property
ump controls
ystem valves
ition while sys
nual air relief
ollow safety a
be properly se
l air relief valv
led properly,
ody is in locke
the system
e injury or dea
o
r piping.
CEMENT PA
his owner’s m
aged, broken,
.
sump or sucti
ind or swellin
rtion of the bo
tly to the intes
sing, or unsec
ir decorations,
:
minimum of tw
all), must be i
stances to avo
on the backre
e return main
aged, broken,
attached sucti
accordance w
able.
s entrapping
lugs used in
pment as de
ar of debris,
as described
he cover/grat
n, cracked, mi
ps and heate
educe risk of i
such as the filt
t
o the pool.
ulation system
ulation syste
ion of the pum
damage, seve
ust be in off
ust be set in a
em pump is ru
alve until a st
d operation in
cured to pump
e must be in o
amaged, or m
position in fil
ith compress
h to anyone n
R
TS
anual and on
cracked, missi
on outlet cove
g
of the limb.
dy or limbs ca
tines through
red can result
finger, toe or
o functioning
nstalled a mini
d “dual block
t for such seat
l
ine.
cracked, miss
n outlet comp
th latest ASM
uction, is reco
interization
cribed above
uch as leaves
above.
e should be i
ssing, or not
r must be pos
jury, do not p
ration system,
s operate und
equipment d
p housing and
e personal inj
osition and fil
position to all
nning. Before
ady stream of
structions cou
housing with
p
en position.
D
ssing. Do not
ter upper body
ed air. Purgin
g
arby. Use onl
the equipmen
ng, or unsecur
that is damag
result in an e
n unprotected
in evisceratio
nuckle to be c
uction outlets
mum of three
a
ge” by a user.
i
ng areas.
ng, or not sec
onents immed
, APSP Standa
mmended.
f the pool/sp
.
, dirt, hair, pa
spected freq
ecurely attac
itioned so as
rmit children t
pumps, and h
r hazardous p
ring pump sta
cover, and/or
ry, or death. B
er manual air r
w system wat
tarting syste
water (not air
l
d result in viol
e
trainer cover l
o not operate
perate pool a
. Never opera
t
the system wi
y
a low pressur
t. Failure to
e
d can cause
e
d, broken,
n
trapment.
suction outlet
n
/
a
ught in an
per pump mus
f
eet (3’) [1 met
e
u
rely attached.
i
ately.
r
ds and CPSC
a from the
p
er and other
u
ently and
h
ed.
o prevent the
o
use or climb
e
aters must be
r
essure during
rt up. Failure t
o
f
ilter housing
efore servicing
elief valve mu
s
e
r to return
m
pump, fully
o
r air and wate
r
nt separation
o
ck ring. Befor
e
p
ool and spa
n
d spa
t
e or test the
th compresse
e (below 5 PSI)
2
t
e
r]
r
o
t
r
)
e
,
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 3
WARNING Risk of Electric Shock. All electrical wiring MUST be in conformance with applicable local codes,
regulations, and the Canadian Electrical Code, ANSI/NFPA70). Hazardous voltage can shock, burn, and cause death or serious
property damage. To reduce the risk of electric shock, do NOT use an extension cord to connect unit to electric supply. Provide a
properly located electrical receptacle. Before working on any electrical equipment, turn off power supply to the equipment. To
reduce the risk of electric shock replace damaged wiring immediately. Locate conduit to prevent abuse from lawn mowers, hedge
trimmers and other equipment. Do NOT ground to a gas supply line.
WARNING Risk of Electric Shock Failure to ground all electrical equipment can cause serious or fatal electrical shock
hazard. Electrical ground all electrical equipment before connecting to electrical power supply.
WARNING Risk of Electric Shock Failure to bond all electrical equipment to pool structure will increase risk for
electrocution and could result in injury or death. To reduce the risk of electric shock, see installation instructions and consult a
professional electrician on how to bond all electrical equipment. Also, contact a licensed electrician for information on local
electrical codes for bonding requirements.
Notes to electrician: Use a solid copper conductor, size 6 or larger. Run a continuous wire from external bonding lug to
reinforcing rod or mesh. Connect a No. 6 AWG (13.3 mm2) solid copper bonding wire to the pressure wire connector provided on
the electrical equipment and to all metal parts of swimming pool, spa, or hot tub, and metal piping (except gas piping), and
conduit within 5 ft. (1.5 m) of inside walls of swimming pool, spa, or hot tub.
IMPORTANT - Reference Canadian Electrical Code, ANSI/NFPA70 codes for all wiring standards including, but not limited to,
grounding, bonding and other general wiring procedures.
CAUTION – HAYWARD® pumps are intended for use with permanently-installed pools and may be used with hot tubs and
spas if so marked. Do not use with storable pools. A permanently-installed pool is constructed in or on the ground or in a
building such that it cannot be readily disassembled for storage. A storable pool is constructed so that it is capable of being
readily disassembled for storage and reassembled to its original integrity.
WARNING Risk of Hyperthermia. To avoid hyperthermia the following “Safety Rules for Hot Tubs” are recommended by
the U.S. Consumer Product Safety Commission.
1. Spa or hot tub water temperatures should never exceed 104°F [40°C]. A temperature of 100°F [38°C] is
considered safe for a healthy adult. Special caution is suggested for young children. Prolonged
immersion in hot water can induce hyperthermia.
2. Drinking of alcoholic beverages before or during spa or hot tub use can cause drowsiness, which
could lead to unconsciousness and subsequently result in drowning.
3. Pregnant women beware! Soaking in water above 100°F [38°C] can cause fetal damage during the first
three months of pregnancy (resulting in the birth of a brain-damaged or deformed child). Pregnant women
should adhere to the 100°F [38°C] maximum rule.
4. Before entering the spa or hot tub, users should check the water temperature with an accurate ther-
mometer; spa or hot tub thermostats may err in regulating water temperatures by as much as 4°F
(2.2°C).
5. Persons taking medications, which induce drowsiness, such as tranquilizers, antihistamines or anti-
coagulants, should not use spas or hot tubs.
6. If the pool/spa is used for therapy, it should be done with the advice of a physician. Always stir pool/ spa
water before entering the pool/spa to mix in any hot surface layer of water that might exceed healthful
temperature limits and cause injury. Do not tamper with controls, because scalding can result if safety
controls are not in proper working order.
7. Persons with a medical history of heart disease, circulatory problems, diabetes or blood pressure
problems should obtain a physician’s advice before using spas or hot tubs.
8. Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above
normal body temperature of 98.6°F [37°C]. The symptoms of Hyperthermia include: drowsiness,
lethargy, dizziness, fainting, and an increase in the internal temperature of the body.
The effects of Hyperthermia include:
1. Unawareness of impending danger.
2. Failure to perceive heat.
3. Failure to recognize the need to leave the spa.
4. Physical inability to exit the spa.
5. Fetal damage in pregnant women.
6. Unconsciousness resulting in danger of drowning.
SAVE THESE INSTRUCTIONS
INS
NO
T
unit
IM
P
ori
g
Thi
s
is i
n
da
m
See
Wa
l
For
1
sho
u
dep
t
plu
s
a le
v
Set
t
Set
t
app
r
(ap
p
and
Afte
the
g
TALLATI
W
a
d
T
T
ICE:
This
S
must be r
P
ORTANT:
g
inal pac
k
a
g
guard will
n
stalled. D
o
m
age the S
H
the chart b
of your
S
l Prepara
” lip mode
ld be notc
h of 1” to
½ inch. B
el and flat
ing of th
he unit wit
oximately
roximately
exposure t
r final inst
rout guar
N INSTR
W
ARNING -
R
nd on the
eath.
his produc
S
HEER unit
,
moved and
Inspect th
e
g
ing until r
e
protect th
not opera
EER.
elow for th
S
HEER.
tion
ls, the wall
ed to a de
ccommod
e sure to in
surface.
e
SHEER
h a levelin
/8”. Fill t
¼”) with a
sunlight
llation, inc
d
.
USE ONL
Y
U
CTIONS:
R
ead throu
quipment
should be
includes
replaced.
unit for d
ady to ins
e
SHEER op
e
e mechani
approxim
should be
pth of 4” (t
te the lip s
clude notc
compoun
e gaps bet
non-expan
ntil it is pe
uding all p
HAYWARD G
gh and fol
. Failure t
installed a
o servicea
mage prio
t
all. Do not
ning from
al soil co
te projecti
otched to
accomm
ction. The
for plumb
such that
een the e
ding seala
rmanently
lastering, r
NUINE REPL
ow all ins
follow in
d serviced
le parts. I
r to install
remove gr
o
amage. P
pactors n
on of the S
H
a depth of
4
date the w
width of t
ng if requi
the lip will
ds of the
t. Once s
c
overed.
e
move
CEMENT PA
ructions e
tructions
only by a
the event
a
tion. Lay
S
o
ut guard
u
rotect the
e
ar SHEER i
n
H
EER. Use
t
”. For 6” l
terbox) wi
e notch sh
ed. The t
extend bey
aterfall an
t, cover th
R
TS
tirely, in
an cause
ualified p
of a produ
S
HEER on fl
a
ntil the ins
nit from di
n
stallation
his chart i
ip models,
h the rest
uld be the
p of the w
nd the fin
d the end
unit to pr
his owner’
severe inj
ol professi
t failure, t
t surface i
tallation is
rect sunlig
areas, as t
h
planning
he back o
f the wall
length of t
ll must be
shed pool
f the notch
tect it from
s manual
u
ry and/or
o
nal.
h
e entire
n the
complete.
h
t until uni
t
h
is may
t
he layout
f
the wall
otched to
e waterfal
f
inished to
w
all by
damage
4
t
a
l
PU
M
PLU
M
M
P SIZING:
In gener
a
example
,
wall of w
a
BING CO
The mos
t
as illustr
a
For multi
p
Two pum
70” of S
H
NOTICE:
Hayward
any larg
e
plumbin
g
If SHEER
recomm
e
The plu
m
NOTE: T
h
Plumb th
turning t
h
fitting. E
If more t
h
filter to t
h
a
l, the pump
,
a pump for
ter. Ratios
NECTIONS
common in
a
ted below.
p
le SHEERs, H
a
ps can be c
H
EER is insta
Only filtere
separate p
u
the SHEER.
recommend
e
debris from
line is acc
flow rate ex
e
nded.
bing conne
e water sup
e unit using
e plumbin
nsure that p
h
an 60” of S
H
h
e SHEERs.
USE ONL
Y
should be s
a 24 inch S
H
of flow appl
:
tallation of
yward recom
nnected to
lled.
water sho
mp is insta
s the use of
constructio
ssible in fin
eeds more
tion is a 1.5
ply line sho
standard P
down as cl
lumbing is s
H
EER length
HAYWARD G
ized to sup
H
EER should
, as can be
the SHEER i
s
mends that i
m
ultiple SH
E
ld be used
led an addi
a plumbing
n to fall out
o
l installati
han 40% of
US standa
u
ld be flush
e
C cement.
se to the ba
ized approp
is installed,
NUINE REPL
ly the SHEE
R
produce ap
p
seen on ch
utilizing th
dividual valv
E
ERs. This i
s
ith this pr
ional prope
trap in front
f the flow s
n, it is reco
the filtered
f
d pipe sock
e
d prior to p
l
or rear mou
ck of the wa
riately for th
2” plumbin
g
CEMENT PA
R
one (1) gal
l
p
roximately
2
rt on page 4
e main pool
e
s and lines
b
the recom
duct. As no
ly sized filt
of each SH
eam, avoid
mended th
low, a sepa
t. This fitti
umbing the
t units, mi
ll as possibl
e required fl
g
, or larger,
i
R
TS
l
on per min
u
24 gallons p
.
pump. A th
e installed to
ended inst
ed in the fi
r is require
ER. As illus
ng damage
at the cap b
ate pump a
g also acce
SHEER.
imize stres
e with a 90
ow to the S
H
s recomme
u
te per inch
o
er minute t
ee way valv
allow balanc
i
llation whe
ures above
between t
rated this tr
to the sheer
e
removable
d filter syst
pts a 2” cou
on the wat
egree elbo
H
EER.
ded from th
Tra
o
f width. Fo
r
o
provide a
e is installe
i
ng of the flo
w
more than
when a
e pump an
ap will allo
. If the
.
em are
pling.
e
rbox by
w
or sweep
e pump and
p
Illustrate
d
5
r
d
w
.
d
w
d
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 6
DIMENSIONS
MODEL NO. A(inch) B(inch) C(inch) D(inch) Port
Location
WFS512R1 12 3 ¾* 3 1 Rear
WFS512B1 12 3 ¾ 3* 1 Bottom
WFS512R6 12 8 ¾* 3 6 Rear
WFS512B6 12 8 ¾ 3* 6 Bottom
WFS524R1 24 3 ¾* 3 1 Rear
WFS524B1 24 3* 1 Bottom
WFS524R6 24 8 ¾* 3 6 Rear
WFS524B6 24 8 ¾ 3* 6 Bottom
WFS536R1 36 3 ¾* 3 1 Rear
WFS536B1 36 3 ¾ 3* 1 Bottom
WFS536R6 36 8 ¾* 3 6 Rear
WFS536B6 36 8 ¾ 3* 6 Bottom
WFS548R1 48 3 ¾* 3 1 Two (2) Rear
WFS548B1 48 3 ¾ 3* 1 Two (2) Bottom
WFS548R6 48 8 ¾* 3 6 Two (2) Rear
WFS548B6 48 8 ¾ 3* 6 Two (2) Bottom
WFS560R1 60 3 ¾* 3 1 Two (2) Rear
WFS560R6 60 8 ¾* 3 6 Two (2) Rear
*Dimension does not include Coupling (Socket)
SHEER with Rear Port
FREEZE PROTECTION and WINTERIZING:
To prevent system damage due to freezing, the plumbing to the SHEERs must be installed such that
water drains easily. The SHEERs have been designed to allow a minimum of water to remain in the unit,
if the plumbing is installed such that the plumbing drains. It is recommended that normal procedures
for winterizing be followed, and all pipes including those to the SHEER, be winterized.
SHEER with Bottom Port
Cut
t
The
e
the l
3/8
finis
lip.
of cl
e
surf
a
To
o
pe
r
Th
e
be
c
un
f
Pro
sol
e
To
o
Ha
y
Ha
y
or
r
Th
e
res
p
Th
e
wa
r
res
p
So
m
lim
ing The
xtended lip
ip is to be r
beyond the
hing. Remo
v
Use the rib r
arance. Re
ce. Replac
riginal purchas
iod of ONE (1) ye
limited warrant
ome defective d
oreseen delays,
of of purchase is
determination
btain warranty
ward Authorize
ward shall not b
r
epair.
Hayward Pool p
ective manufac
express limited
ranties express
onsible for any
e states do not
itation may not a
*Superse
d
xtended
(6”) model
moved, allo
final finish
o
e the Grout
emoval tool
move all br
the Grout
H
rs of this equip
r from the date
excludes dama
ring the warran
w
ithout charge.
required for war
f the purchase
ervice, please c
Service Center
e responsible fo
oducts warranty
t
urer will apply.
warranty above
d or implied, inc
consequential, s
allow a limitatio
pply to you. Thi
s
es all previous
USE ONL
Y
L
ip
can be cut
ing for roo
of
the wall.
A
Guard befo
to remove t
ken pieces
G
uard.
AYWAR
ent, Hayward P
f purchase, wh
e from freezing,
y period shall b
anty service. In
d
ate.
ntact the place
lease visit us at
cartage, remov
does not apply t
c
onstitutes the e
n
luding warrantie
pecial or inciden
on how long an
warranty gives
publications.
HAYWARD G
o custom s
for the til
minimum
e cutting th
e ends of t
f
rom the SH
E
D
®
Pool P
r
ol Products, Inc.
n used in single
negligence, imp
repaired or repl
the event proof
o
f purchase or th
www.hayward.c
o
l, repair or instal
o components m
tire warranty of
of merchantabi
al damages of a
implied warrant
ou specific legal
NUINE REPL
apes depe
and thin se
ength of 1
e
lip. Cut ca
r
h
e exposed r
i
E
ER. Sand,
o
oducts L
warrants its SH
E
family residenti
oper installatio
ced, at our opti
f purchase is no
nearest Haywa
o
m.
lation labor or a
anufactured by
Hayward Pool Pr
ity or fitness for
ny nature.
lasts, or the ex
rights, and you
CEMENT PA
ding on the
t such that t
” on the lip
efully to av
ibs, back fr
r use a flam
imited W
E
ER to be free fro
m
a
l applications.
, improper use o
n, within 90 da
t available, the
d Authorized Se
y other such co
thers. For such
ducts with resp
a particular purp
lusion of incide
ay also have ot
R
TS
application
he lip will p
must remai
id creation
m the cut e
e on the ed
a
rranty
defects in mat
r care or any Act
s of the receipt
anufacturing da
vice Center. For
ts incurred in ob
roducts, the wa
ct to its pool pr
ose. In no event
tal or conseque
her rights, which
Determine
otrude a mi
after cutti
f jagged ed
ge, to provi
e to provide
rials and workm
s
of God. Parts th
o
f defective prod
u
te of the product
assistance on y
o
b
taining warranty
rranty establish
e
ducts and is in l
shall Hayward P
o
n
tial damages, s
o
vary from state
Haywa
62
Eliz
how much
n
imum of
n
g and
ges on the
d
e about 1”
a smooth
m
anship for a
at fail or
u
ct, barring
will be the
o
ur nearest
replacements
e
d by the
ieu of all other
o
ol products be
o
the above
t
o state.
rd Pool Products
0 Division Street
abeth, NJ 07207
7
f
Plea
s
First
Stre
e
City
_
Pho
n
E-M
a
Mod
Pool
If yo
u
nece
Inst
e
seri
a
Ple
a
Mail
Attn
:
Or R
E
----
-
S
DATE O
F
Hayward is a re
g
© 2015 Haywar
d
e Print Clear
Name_____
t Address_
__________
e Number_
il Address_
el Number__
Capacity___
r product con
ssary to comp
ad, complete
l number that
se include me o
to: Hayward
:
Warranty De
p
GISTER YOU
DETACH
H
---------------
HEE
INSTALLA
Retain this W
istered trademark o
d
Industries, Inc.
l
y:
_________
__________
_________
__________
__________
__________
__________
tains compon
lete warranty
arranty regis
is located on
n
all e-mail com
m
Pool Product
p
t
WARRANTY
H
ERE:
Fill out b
o
-
---------------
R
5
0
0
USE ONL
Y
T
ION __
_
rranty Certific
f Hayward Industries
____ Last N
__________
_______ Sta
________ P
_
_________
_
___________
(U.S. Gallons
nts that hav
egistration fo
tration only f
he outside of
m
unications rega
r
, 620 Divisio
O
N-LINE AT W
W
ttom portion c
----------------
0
HAYWARD G
PRODUC
T
(Retain
________
ate (upper po
, Inc.
a
me_______
_
_________
e_________
rchase Date
__________
__________
)
individual se
r those indivi
r the overall
the product p
r
ding Hayward
®
E
n Street, Eliz
W.HAYWAR
mpletely and m
----------------
NUINE REPL
REGISTR
For Your Recor
d
_
________
tion) in a saf
__________
__________
_ Zip_____
_________
__________
__________
ial numbers,
ual compone
roduct, using
ackaging.
quipment or pro
beth, NJ 072
D
.COM
ail within 10 da
---------------
CEMENT PA
A
TION
d
s)
and conveni
_
______
_
_____
_
______
_
______
_
_____
_
_____
it is not
n
ts.
the
motions.
07
s of purchase/
---------------
Warr
a
Y
ear
s
< 1
Purc
h
Bu
i
Com
p
Addr
City
_
Pho
n
Type
C
o
Ot
N
e
Inst
a
In
R
TS
nt location fo
installation or r
---------------
nty Ca
Pool has been i
year 1-3
ased from____
ilder Retailer
any Name____
ess___________
_____________
e____________
of Pool:
ncrete/Gunite
her___________
e
w Installation
a
llation for:
Ground Ab
o
r your records
e
gister online.
---------------
d Regis
n service
4-5 6-10
1
_____________
Pool Service
_____________
_____________
_____ State___
_____________
Vinyl Fib
e
_____________
Rep
l
o
ve Ground
.
--------------
t
ration
1
1-15 >15
_
__________
Internet/Catalo
g
_____________
_
_____________
_ Zip_________
_____________
e
rglass
_
___
l
acement
Spa
8
_
_
_
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Hayward Sheer 500 Owner's manual

Category
Above ground pool accessories
Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI