Quick Start Technical Support (800) 726-8663 61200323L1-13B
November 2001
Copyright © 2001 ADTRAN All rights reserved
For more detailed documentation, visit us online at www.adtran.com
TOTAL ACCESS
®
4303 BNC MODULE
R1
C12
C13
FB2 FB3
C2
R5
C3
C6
C9
O
N
C1
C5
C15
C10
C11
SW1
R6
R3
R4
P1
P2
R9
R10 R2
C7
C14
R11
1 2 3 4 5
O
N
R 8
C 4
EXT STA CLK
P50 P52 P51
A - IN A - OUT B - IN
P53
B - OUT
+
_
s
+
_
s+
_
s
+
_
s
NTWK MGMT
A MISC B
TRS
TRS ABAB AB AB
AUX1 AUX2
ACO RMT
AUX1 AUX2
NO COM NC
NO COM NC
-48 VDC PRI
-48 VDC RET
-48 VDC SEC
-48 VDC RET
E - NET B E - NET A
NO COM NC NO COM NC NO COM NC
AUD. ALARM OUTPUTS
CRI - A MAJ - A MIN - A
VIS. ALARM
OUTPUTS
CRI - V MAJ - V MIN - V
NO COM NC NO COM NC NO COM NC
TX 4
TX 3
ADTRAN 1999 © COPYRIGHT
5200330-1B
RX 4
RX 3
RX 2
TX 2
RX 1
TX 1
ADMIN
BNC Module
Slots 1&2
BNC Module
Slots 3&4
INSTALLATION INFORMATION
• Connect the module to the I/O Module connectors located on the backplane of the TA 4303 unit. For
Slots 1 and 2, use the I/O Module connectors at the top of the backplane, labeled J1 and J2. For
Slots 3 and 4, use the I/O Module connectors at the bottom of the backplane, labeled J3 and J4.
Refer to the above figure for a diagram of installed BNC Modules.
• The installed BNC Module provides two dual BNC Female connectors. Continue the installation by
connecting the appropriate cables to the TA 4303.
• Once powered, the SCU will automatically activate the BNC Module using the current module switch
settings. No further configuration is necessary to activate the interfaces.
• Once installed, use the terminal menus to configure and control the DS3 or STS-1 modules (see the
SCU Quick Start, 61200334L1-13A).
• Use the arrow keys on your VT-100 terminal keyboard to move to the Modules menu; press Enter in
the Menu column of the appropriate module.
Disconnect the TA4303 Chassis from power before installing the BNC Module.
CLEI Code: SLL34Y4J_ _