For your safety
Information on these instructions
These operating instructions contain important information for proper
and safe operation of the product.
Therefore, read the operating instructions through in full before you
use the product. Otherwise there is a risk of hazards to personnel
and damage to the product.
Keep the operating instructions safe. If you pass on the product to
third parties, you must also hand over the operating instructions with
it.
Intended use
The product is used for giving aroma to the air in closed indoor
rooms only. The product is not intended for commercial use but
rather only domestic use.
Intended use also includes compliance with all information and spec-
icationscontainedintheseoperatinginstructions.Anyuseother
than for its intended purpose shall be deemed as misuse.
L Misuse
Misuse of the product can lead to hazardous situations.
Onlyeverlltheproductwithwater.Donotuseanyotherliquids.
Do not use the product in wet rooms, such as bathrooms or sau-
nas.
Donotusetheproductinroomswithopenre(replace,gas
cooker, candles etc.).
Do not insert any objects into the openings of the product.
Do not place the product directly in front of an air conditioning unit
or other electrical devices.
The device must be used only with the adaptor (GQ05-050080-AG)
supplied with the appliance.
GB
GB
10
For your safety
L Children
This device can be used by children of 8 years of age and above
and by persons with restricted physical, sensory or mental capacity
or lack of experience and knowledge if they are supervised or have
been instructed on the safe use of the device and understand the
resultant hazards.
Make sure that the product is set up out of the reach of children.
Make sure that children are not allowed to play with the product at
any time.
Cleaning and user maintenance must not be performed by children
without supervision.
Do not leave packaging material lying around unattended. There is
a risk of asphyxiation.
L 
Improper handling
Improper handling of the product can cause injuries.
Make sure that the product is connected properly. In the process,
adhere to these operating instructions.
Make sure that the product is used properly. Never cover it.
Beawarethatunauthorisedconversionand/ormodicationofthe
product is prohibited. In case of unauthorised conversion and / or
modicationthewarrantycoverwillberenderednullandvoid.
Never open the water tank during operation.
Beforellingoremptyingtheproduct,alwayspullthemainsplug
from the socket.
Before installation, cleaning or a period in which the product is not
used, pull the mains from the socket.
Empty the water tank before a period in which the product is not
used.
GB
Art. 60080
11
For your safety
Contact the manufacturer or a specialist if you have any doubts
regarding the way the product works, its safety or how to connect
the product.
L Setting up
Ifliquids,dampairorrecomeintocontactwiththeproduct,thereis
a risk of injuries.
Do not set up the product in rooms with high air humidity, such as
bathrooms or saunas.
Make sure that no liquids enter into the inside of the housing. This
willnotonlydestroytheproductbutthereisalsoariskofre.
Protect the product from the effects of the elements. Do not set it
up outdoors.
Onlyeverplacetheproductonatsurfaces.Ifplacedonan
inclined surface, water from the water tank may enter into the
housing.
Make sure that the air inlet openings on the base of the product are
not covered or sealed.
GB
12
For your safety
Functions
The aroma diffuser is a modern fragrance diffuser which uses ultrasound technology to generate a
nemistandthusdistributethefragrancethroughoutthewholeroom.
Operating buttons
The aroma diffuser is controlled using an operating button.
Button Function
Power button:
This button is used to switch the device on and off.
Ifthedeviceismovedduringoperation,anLEDashesandthediffusionoffragrancestops.Insuch
an event, the device has to be switched back on using the power button.
Cleaning and servicing
Before cleaning, pull the mains plug.
Empty the device after each use and dry the water tank with a cloth.
Wash the water tank with clear water when you wish to change the aroma. This prevents mixing
different aromas.
Only clean the outside of the device with a soft, slightly damp cloth. Then rub it dry with a soft, dry
cloth.
Do not under any circumstances us brushes, sharp cleaning implements, benzene, thinners or
alcohol.
Descaling
Descalethedeviceafterveorsixusesorevery14days.Todoso,proceedasfollows:
1. Disconnect the device from the power supply.
2. Fill the water tank with a maximum of 80 ml of water and add a tablespoonful of citric acid.
3. Allowtheliquidtotakeeffectforatleastfteenminutes.
4. Empty out the liquid.
5. Wipe out the water tank with a dry cloth.
However, if you have any questions, please contact our service department. The service department
address is included on the separate supplementary sheet.
Disposal
Electrical and electronic components must not be disposed of with the domestic waste.
Once the product reaches the end of its service life, dispose of it and its components sepa-
rately in accordance with the local valid regulations for disposal.
GB
Art. 60080
13
Technical data / Warranty
Technical data
AC adapter (GQ05-050080-AG)
Input: 100-240 V ~ 50/60 Hz, 0.2 A
Output:
Voltage: DC 5 V
Current: 0.8 A
Device
Voltage: DC 5 V
Current: 0.8 A
Power: 4 W
Water tank capacity: 80 ml
Dimensions: approx. 68 mm x 120 mm x 90 mm
Weight: approx. 115 g
We reserve the right to make technical and design changes in the interest of constant product
improvements.
The current version of these operating instructions can be found at http://www.medisana.com.
Warranty and repair terms
Please contact your dealer or the service centre in case of a claim under the warranty. If you have to
return the unit, please enclose a copy of your receipt and state what the defect is.
The following warranty terms apply:
1. The warranty period for MEDISANA products is three years from date of purchase. In case of a
warranty claim, the date of pur chase has to be proven by means of the sales receipt or invoice.
2. Defects in material or workmanship will be removed free of charge within the warranty period.
3. Repairs under warranty do not extend the warranty period either for the unit or for the replacement
parts.
4. The following is excluded under the warranty:
a. All damage which has arisen due to improper treatment, e.g. non-observance of the user instruc-
tions.
b. All damage which is due to repairs or tampering by the customer or unauthorised third parties.
c. Damage which has arisen during transport from the manufacturer to the consumer or during
transport to the service centre.
d. Accessories which are subject to normal wear and tear.
5. Liability for direct or indirect consequential losses caused by the unit are excluded even if the
damage to the unit is accepted as a warranty claim.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54

Medisana AD 610 Owner's manual

Category
Aroma lamps
Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI