LY International Electronics H-8500 Series Owner's manual

Type
Owner's manual

This manual is also suitable for

OWNER'S MANUAL
INFRARED WIRELESS CONFERENCE
SYSTEM
H-8500 SERIES
Version: REV2.0 (2010)
1
[Table of Contents]
Overview
1. System Configuration and description-----------------------------------------------3
1.1 System features-----------------------------------------------------------------------3
1.2 Infrared conference system main unit ----------------------------------------------3
1.2.1 Picture of the actual object -----------------------------------------------------------3
1.2.2 Features of infrared conference system main unit -----------------------------------3
1.2.3 Schematic diagram of infrared conference system main unit -----------------------4
1.2.4 Parameter of infrared conference system main unit----------------------------------5
1.3 Infrared conference system microphone unit ---------------------------------------5
1.3.1 Picture of the actual object -----------------------------------------------------------5
1.3.2 Features of infrared delegate microphone -------------------------------------------6
1.3.3 Features of infrared chairman microphone ------------------------------------------6
1.3.4 Schematic diagram of infrared microphone ------------------------------------------6
1.3.5 Parameter of infrared microphone unit -----------------------------------------------7
1.4 Distributor ----------------------------------------------------------------------------8
1.4.1 Picture of the actual object -----------------------------------------------------------8
1.4.2 Features of distributor ----------------------------------------------------------------8
1.4.3 Schematic diagram of distributor ----------------------------------------------------8
1.4.4 Parameter of distributor --------------------------------------------------------------8
1.5 Infrared receiver unit -----------------------------------------------------------------9
1.5.1 Picture of the actual object------------------------------------------------------------9
1.5.2 Features of receiver unit--------------------------------------------------------------9
1.5.3 Schematic diagram of receiver unit---------------------------------------------------9
1.5.4 Parameter of receiver unit------------------------------------------------------------9
1.6 Battery charger ---------------------------------------------------------------------10
1.6.1 Picture of the actual object----------------------------------------------------------10
1.6.2 Features of battery charger----------------------------------------------------------10
1.6.3 Schematic diagram of battery charger----------------------------------------------10
1.6.4 Parameter of battery charger--------------------------------------------------------11
1.7 Infrared conference system external antenna -------------------------------------11
1.7.1 Picture of the actual object----------------------------------------------------------11
1.7.2 Schematic diagram of external antenna--------------------------------------------11
1.7.3 Parameter of external antenna------------------------------------------------------12
1.8 Infrared conference system LIP battery -------------------------------------------12
1.8.1 Picture of the actual object----------------------------------------------------------12
1.8.2 Features of LIP battery---------------------------------------------------------------12
1.8.3 Schematic diagram of LIP battery---------------------------------------------------12
1.8.4 Parameter of LIP battery-------------------------------------------------------------12
1.9 AC power adapter -------------------------------------------------------------------13
1.9.1 Picture of the actual object----------------------------------------------------------13
1.9.2 Schematic diagram of AC power adapter--------------------------------------------13
1.9.3 Parameter of AC power adapter-----------------------------------------------------13
2. System installation------------------------------------------------------------------14
2.1 System connection diagram---------------------------------------------------------14
2.2 Warning------------------------------------------------------------------------------15
2
2.2.1 CAUTION on handling of the microphone unit---------------------------------------15
2.2.2 CAUTION on installation-------------------------------------------------------------16
2.2.3 CAUTION on battery charger handling----------------------------------------------16
2.2.4 CAUTION on battery handing--------------------------------------------------------16
2.2.5 CAUTION on handling the AC adapter-----------------------------------------------16
2.3 Identify room layout-----------------------------------------------------------------17
2.3.1 Check coverage area-----------------------------------------------------------------17
2.3.2 The relationship between ceiling height and infrared emitting and receiving
coverage area------------------------------------------------------------------------17
2.3.3 Check quantity of receiver unit------------------------------------------------------17
2.3.4 System configuration----------------------------------------------------------------18
2.4 Installation and connection of IR main unit-----------------------------------------18
2.4.1 IR main unit installation-------------------------------------------------------------18
2.4.2 IR main unit to IR receiver unit------------------------------------------------------18
2.4.3 IR main unit to sound system--------------------------------------------------------19
2.4.4 IR main unit to video processor------------------------------------------------------19
2.4.5 IR main unit to external antenna----------------------------------------------------20
2.5 Installation of IR receiver unit-------------------------------------------------------20
2.5.1 IR Receiver operating range---------------------------------------------------------20
2.5.2 Installation diagram of IR receiver unit---------------------------------------------22
2.5.3 Wiring between IR receiver unit and main unit when using distributors------------22
2.5.4 Caution item-------------------------------------------------------------------------24
2.6 Installation of IR microphone unit---------------------------------------------------24
2.6.1 Mounting and dismounting the battery----------------------------------------------24
2.6.2 Mounting and dismounting the microphone-----------------------------------------24
2.6.3 Microphone operating range and distance------------------------------------------25
2.6.4 Examples of square arrangements--------------------------------------------------25
2.7 System setting-----------------------------------------------------------------------26
2.7.1 Main unit setting---------------------------------------------------------------------26
2.7.2 Microphone setting------------------------------------------------------------------27
2.8 System LCD--------------------------------------------------------------------------27
2.8.1 Schematic diagram of main unit LCD------------------------------------------------27
2.8.2 Schematic diagram of microphone LCD---------------------------------------------28
3. Troubleshooting---------------------------------------------------------------------30
3
Overview
The infrared conference system has all the advantages of infrared communication
complete with wireless receiver microphone units. Wireless infrared technology provides
the user with greater flexible whilst configuring the system and freedom of choice when
placing microphones, it guarantees conference privacy and protects the system from
wiretapping and radio interference. It’s the best wireless conference solutions for
small-scale conferences.
1. System Configuration and description
Infrared conference system main unit, infrared receiver unit, infrared chairman
microphone, infrared delegate microphone, distributor, battery charger, etc.
1.1 System features
a. Infra-red transmission technology guarantees privacy.
b. Perfect sound quality as CD from the microphone.
c. IR communication system eliminates the need of connecting the conference units.
Installation can be done quick and smart without cumbersome arrangements.
d. Fully functions (Discuss & Video tracing), support FIFO (1/2/3), Limit (1/2/3) and
chairman only mode, microphones in one system up to 128 units.
e. Microphones can be operated on either their built-in rechargeable lithium-ion
batteries or AC power supply. Battery life approx. 8 hours during speech and approx.
30 hours when standby.
f. Microphone LCD can display system and conference information.
g. Excellent immunity to RF interference from mobile phones and RF devices.
1.2 Infrared conference system main unit H-8500M
1.2.1 Picture of the actual object
1.2.2 Features of infrared conference system main unit
a. Support Mode: Limit (1/2/3), FIFO (1/2/3), Chairman Only
b. Support video camera auto-track with video processor
c. 160x32 dot matrix LCD display system information
d. Two group audio output interface to support external audio system
e. Installation: 19-inch frame
f. Designed accordance to UL and CE standards
g. If main unit turn off power, microphone will shut off the power within 60 seconds.
4
1.2.3 Schematic diagram of Infrared conference system main unit
1) Power switch (Press I to turn on the power, power indicator is lighting, press O to turn
off the power)
2) LCD (Display current mode, online microphone number, activity microphone number
and ID)
3) Admin card interface
4) Menu: system volume/LCD contrast/project setting
5) Mode choose/setting key
6) Mode choose/setting key
7) Enter: To confirm the setting
8) Data Communication: Data communication indicator, if main unit data communication
properly, the blue LED will flashing rhythmically.
9) Audio Level indicator
10) Antenna interface
11) Data: External video processor connection interface
12) Audio out interface
13) System line out interface
14) AF IN A: Receiver connection interface
15) AF IN B: Receiver connection interface
16) Fuse (0.5A)
17) AC Power input (AC110~220V 50~60Hz)
5
1.2.4 Parameter of infrared conference system main unit
Items Parameter
Audio channel
Transmission method Wireless infrared
Audio channel 4
Carrier frequency band 6MHz-8MHz
Modulation method FM
Receiving sensitivity -85dBM
Output level 0dB
Infrared operating distance 10M
Frequency response 100Hz-10KHz
S/N Ratio 70dB
T.H.D. 0.5%
Data control
channel
Transmission method Wireless
Data channel 14
Frequency Range 901MHz-927MHz
Modulation method FSK
Receiving sensitivity -80dBM
Transmission consumption 10dBM
Communication rate 100KBPS
Signal covering range Radius 100M
System
Power supply AC110V-240V/50Hz~60Hz
Consumption Rating 10W
Operating temperature range
0-40 degree
Dimensions 484×377×85mm
N.W 6.81kg
1.3 Infrared conference system microphone unit H-8500c,d
1.3.1 Picture of the actual object
6
1.3.2 Features of infrared delegate microphone
a. Newly digital design
b. Portable table moving and microphone pipe can be pull out. Extended pipe optional.
c. Electric capacity type microphone, equipped with windshield cover
d. LCD color red/blue (option)
e. LCD display microphone ID, signal level, battery level, microphone state, control
channel, etc.
f. Equipped with microphone on/off key and indicator.
g. Equipped with 5 function keys to set microphone id, control channel, LCD contrast and
light time.
h. Auto-Close: Microphone will turn off automatically if there is no action of this
microphone in 99 seconds. (option)
i. Microphone will shut off the power in 60 seconds to save battery power if system
communication is error.
j. LCD will display “IR Signal Weak” if the IR signal is weak when microphone working.
1.3.3 Features of infrared chairman microphone
Including the functions of the delegate unit, chairman unit has other following functions:
a. Chairman microphone can turn on any time.
b. In one system microphones just support one chairman microphone and the ID number
should be 1.
c. Priority function: chairman can turn off delegate microphones any time.
d. Chairman only mode: Delegate microphone can not be turned on again after chairman
microphone press priority button. The chairman need quit this mode first, and then
delegate microphone can be turned on again.
1.3.4 Schematic diagram of infrared microphone
7
1) Annular red indicator lamp to show the microphone state.
2) Unidirectional electret MIC
3) LCD
4) IR sensor
5) Menu/Back key: Press this key to enter menu setting or back after setting
6) Left key
7) Right key
8) MIC ON/OFF key
9) Chairman Priority
10) Up key
11) Down key
12) Microphone power switch
13) DC power input
1.3.5 Parameter of infrared conference system microphone unit
Items Parameter
Audio channel
Transmission method Wireless infrared
Audio channel 4
Carrier frequency band 6MHz-8MHz
Modulation method FM
Infrared radiator consumption +10dBM
Mic sensitivity -44dB±2dB
Frequency response 100Hz-10KHz
S/N Ratio 70dB
T.H.D. 0.5%
Reference sound receiving 10-30cm
Data control
channel
Transmission method Wireless
Data channel 14
Frequency Range 901MHz-927MHz
Modulation method FSK
Receiving sensitivity -85dBM
Transmission consumption 10dBM
Communication rate 100KBPS
Microphone
Battery LIP battery12V/4000MAH
Consumption Rating 8W
Operating temperature range 0-40 degree
Length of gooseneck 400mm (optional)
Dimensions 220×155×69mm
N.W 815g (with battery)
8
1.4 Distributor H-8500T
1.4.1 Picture of the actual object
1.4.2 Features of distributor
a. Adopt impedance balancing branch connector (2 input, 1output)
b. Low insertion loss computation
c. Perfect plating surface treatment with excellent shielded function
1.4.3 Schematic diagram of distributor
1) BNC terminal: Connector for the BNC coaxial cable connection
2) Mounting and fixing holes: Holes for mounting distributor body
1.4.4 Parameter of distributor
Items Parameter
Carrier frequency band 6MHz-8MHz
Insertion loss computation 1dBM
Input/Output Impedance 50Ω
Input terminal 2
Output terminal 1
Terminal type BNC
Dimensions 80×65×20mm
N.W 90g
9
1.5 Infrared receiver unit H-8500R
1.5.1 Picture of the actual object
1.5.2 Features of receiver unit
a. Adopt mounting hook installation, easy to install.
b. Wide-angle, receiving range is approximately 150 degrees.
c. Signal gain more than 35dBM
d. Adopt low consumption electro circuit
e. Wall/ceiling installation option.
1.5.3 Schematic diagram of receiver unit
1) Power LED: This Led will light when the main unit turns on after wiring.
2) IR lens
3) BNC connector A ( for wall installation)
4) BNC connector B ( for ceiling installation)
5) BNC connector switch A/B (Please select correct position according to the installation)
1.5.4 Parameter of infrared conference system receiver unit
Items Parameter
Carrier frequency band 6MHz-8MHz
Power supply DC12V from Main unit
Rated current 25mA
Receiving sensitivity -85dBM
Gain 40dBM
Output Impedance 50Ω
Terminal type BNC
Dimensions φ98×74mm
N.W 440g (with bracket)
10
1.6 Battery charger H-8500CG
1.6.1 Picture of the actual object
1.6.2 Features of battery charger
a. Input Voltage: AC 110V~220V
b. Charges 16 PCS of LIP battery per charging
c. Intelligent charging management electro circuit to protect the LIP battery
d. Equipped with extendible handle and pulley, easy for moving.
1.6.3 Schematic diagram of battery charger
1) Pulley
2) Extendible handle
3) Charging status indicator LED
4) Battery holder
5) Power indicator
6) Power on/off switch
7) AC adapter jack (AC110V-220V 50Hz-60Hz)
11
10.3. Parameter of battery charger
Items Parameter
Power supply 110V-240V/50Hz~60Hz
Consumption Rating 200W
Charge quantity 16
MAX charging current of each 700mA
Charging time About 8~10 hours
Charging status Red LED flashing –Charging, Green LED –Full
Operating temperature range 0-40 degree
Dimensions 620×370×260mm
N.W 10.74kg
1.7 Infrared conference system external antenna H-8500AT
1.7.1 Picture of the actual object
1.7.2 Schematic diagram of external antenna
1) Antenna
2) Signal BNC connector
3) Mounting bracket
1.7.3 Parameter of external antenna
12
Items Parameter
Carrier frequency band 915MHz-925MHz
Impedance 50Ω
MAX cable length 20m
Terminal type BNC
Dimensions 345×80mm(with bracket)
N.W 100g (with bracket)
1.8 Infrared conference system LIP battery H-8500B
1.8.1 Picture of the actual object
1.8.2 Features of LIP battery
a. Excellent safety performance, light weight & High capacity ratio.
b. Improved safety: more resistant to overcharge; less change for electrolyte leakage.
c. High Capability: Have nearly double the capacity with half the weight of NiCad or NiMH
battery packs
d. Easy to install
1.8.3 Schematic diagram of LIP battery
1) Battery removal button (RELEASE)
2) Battery detach button
3) Negative
4) Positive
1.8.4 Parameter of LIP battery
Items Parameter
Rated voltage DC12V
Discharge current 500mA
Charging current 700mA
Time of speaking 8 hours
Time of standby 25 hours
Charging voltage DC15V
Dimensions 130×75×20mm
N.W 250g
13
1.9 AC power adapter H-8500A
1.9.1 Picture of the actual object
1.9.2 Schematic diagram of AC power adapter
1) AC Power plug
2) Transformer
3) DC plug
1.9.3 Parameter of AC power adapter
Items Parameter
Input voltage AC110V/220V 50Hz~60Hz
Output voltage DC 18V 600mA
Dimensions 98×70×55mm ( only transformer)
N.W 750g
14
2. System installation
2.1 System connection diagram
15
2.2 Warning
If the units demonstrate any problems, such as abnormal sound, smoke, heat from or
damage to power cables, disconnect the power plug from the outlet and contact your
sales representative.
If the power plug blades are distorted or discolored, do not use the unit
(Main unit, Battery charger)
Uncoil the power cables before use, Do not bundle the cables during use, or fie with
nails. (Main unit, Battery charger)
Do not pull on the cable. Hold the plug section and insert/remove it in a straight line,
damaged cables may result in electric shock, malfunction, or fire.
(Main unit, Battery charger)
Do not place anything on the power cables. Do not route them under a rug or
furniture.
(Main unit, Battery charger)
Do not cover the units with cloth or place them in locations with poor ventilation.
Doing so traps heat, and may result in electric shock or fire
If you do not use the units for long periods of time, disconnect the power plugs from
the outlet
(Main unit, Battery charger)
Do not disassemble the units. Touching the inside of the units may result in electric
shock
Do not expose the units to any strong shock
Do not exposé the units to direct sunlight, heat from heating appliances, high
temperatures, or dust
Do not expose the units to high humidity or moisture
Water that accidentally enters the inside of the units may result in electric shock,
malfunction, or fire
Do not touch the power cables or plugs with wet band
(Main unit, Battery charger)
Main unit is a class I device. Be certain to connect to an AC outlet with a protective
grounding connection
Main unit can be separated from the AC receptacle by turning off the unit by the front
power switch. In case of emergency, turn off this switch or unplug the power cable
from the AC receptacle
2.2.1 CAUTION on handling of the microphone unit
Do not grasp the microphone to lift or pull on the microphone unit: pick up the unit by
its base
Slowly bend and straighten the flexible part of the microphone. Do not bend it with
excessive force
Do not drop the unit
If you do not use the unit for long periods of time, remove the battery
The dedicated lithium-ion battery should be used
Do not cover the infrared section
When the microphone units are too close together, high sound volume may cause
acoustic feedback, In this case, increase the space between the conference units or
16
turn down the volume
After the battery has been removed and replaced, confirm that the power LED turns
off
2.2.2. CAUTION on installation
After mounting the IR receiver units, be certain that they are securely fastened
Do not install the IR receiver units or the microphone units near infrared-emitting
objects such as direct sunlight, incandescent lamps, halogen lamps, inverter
fluorescent lamps, or plasma displays
Noise may be generated by interference regardless of the operating distance between
the IR receiver unit away from infrared-emitting objects
Do not place any obstructions around the microphone units
2.2.3 CAUTION on battery charger handling
If the charging terminal is dirty, poor contact will prevent the battery from being
charged properly. Periodically clean the charging terminals
The battery charger may become hot during charging. Use it in a well-ventilated area
After the battery is fully charged, turn off the battery charger or remove the batteries
2.2.4 CAUTION on battery handling (optional)
The battery is dedicated to the microphone unit. Do not use it for other applications
Use only the designated battery charger
If the battery leaks and the liquid contacts your skin or clothing, immediately flush
with clean water
If the battery leaks and the liquid contacts your eyes, immediately wash thoroughly
with clean water and seek medical assistance
Do not throw the battery into fire or overheat it, Doing so may result in a fire
Do not disassemble or modify the battery
Do not short-circuit the + and terminals with any metal or wire. Do not carry or
store the battery with metal products such as a necklace.
If you discover battery leaks, discoloration, distortion, or the other problems, do not
use the battery
Dispose of used batteries properly as industrial waste or contact our business office in
your neighborhood
2.2.5 CAUTION on handling the AC adapter (option)
If the unit exhibits any problems, such as abnormal sounds and smoke, pull the power
plug from the outlet and contact your sales representative
Do not pull on the cable. Hold the plug and insert/remove it in a straight line.
Damaged cables may result in electric shock, malfunction, or fire
Do not cover the units with cloth. Doing so traps heat and may result in electric shock
or fire
Do not handle the adapter with wet hands
If you do you use the units for long periods of time, disconnect the power plugs from
the outlet
17
2.3 Identify room layout
2.3.1 Check coverage area
Real coverage area of conference room (usually coverage area of conference room is
smaller than the conference room area)
2.3.2 The relationship between ceiling height and infrared emitting and
receiving coverage area.
Note: The height mentioned about is the distance from ceiling to desk.
2.3.3 Check quantity of receiver unit
Please check the ceiling height and coverage area of one receiver unit with above
information (2.3.2), to make sure real coverage area can receive the signal well.
Calculate formula: (A: Receiver quantity, B: Real coverage area, C: Coverage area of one
receiver unit)
AB/C
Note: IR receiver unit quantity may increase according to the actual installation place
Ceiling
height
Coverage
area/receiver
unit
2.5 m 20 m2
3 m 28 m2
3.5 m 38 m2
4 m 50 m2
4.5 m 63 m2
5 m 78 m2
5.5 m 95 m2
6 m 113 m2
6.5 m 130 m2
18
2.3.4 System configuration.
Description Model No. Max Qty Marks
IR Main Unit H-8500M 1
Chairman Microphone H-8500c 1
Delegate Microphone H-8500d ≤127
IR Receiver H-8500R ≤24
Distributor H-8500T
External Antenna H-8500AT 1
Battery Charger H-8500CG
LIP Battery H-8500B
AC adaptor H-8500A
Admin Card
2.4 Installation and connection of IR main unit
2.4.1 IR main unit installation
a. Put on the table or install in 19 inch frame
b. Please keep away from high-power and strong radiation equipments, or it may
influence the equipment performance.
c. Use it in a well-ventilated area
2.4.2 IR main unit to IR receiver unit
Connect one side of coaxial cable to the BNC terminal (RF A/B) of IR main unit; the other
side connects to the BNC terminal of IR receiver unit. If system install more than 2pcs IR
receiver unit, the other side should connect to BNC terminal (RF OUT) of the distributor
first, then connect the IR receiver unit to the BNC terminal (RF IN A/B).
Please note: coaxial cable should be 50Ω.
Please read 2.5 to get detailed information of IR receiver unit installation method.
19
2.4.3 IR main unit to sound system
a. Mono output: Please connect AF OUT interface of IR main unit to input interface of
sound equipment by Φ6.3 audio cable
b. Dual track: Please connect LINE OUT-L/R interface of IR main unit to input interface of
sound equipment by RCA audio cable
2.4.4 IR main unit to video processor
Please connect DATA (A-G-B) interface of IR main unit to DATA interface of video
processor by RJ45 network cable. Please read the user manual of video processor.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31

LY International Electronics H-8500 Series Owner's manual

Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI