Mitsubishi Electric PAC-SG59SG-E Installation guide

Category
Split-system air conditioners
Type
Installation guide

Mitsubishi Electric PAC-SG59SG-E is an air outlet guide designed to change the air blowing direction of compatible outdoor units. It can be used to prevent short cycles and is especially useful in areas where strong winds or obstacles may disrupt airflow. The guide can be installed in four different directions: upward, downward, or to the left or right. It is compatible with a range of Mitsubishi Electric outdoor units, including the PUHZ-ZRP60,71VHA2, PUZ-ZM60VHA, PU-P71,100VHAR3, PUHZ-SHW112VHA, and PU-P125,140YHAR6.

Mitsubishi Electric PAC-SG59SG-E is an air outlet guide designed to change the air blowing direction of compatible outdoor units. It can be used to prevent short cycles and is especially useful in areas where strong winds or obstacles may disrupt airflow. The guide can be installed in four different directions: upward, downward, or to the left or right. It is compatible with a range of Mitsubishi Electric outdoor units, including the PUHZ-ZRP60,71VHA2, PUZ-ZM60VHA, PU-P71,100VHAR3, PUHZ-SHW112VHA, and PU-P125,140YHAR6.

E-258
OPTIONAL
PARTS
571.4
559 (Installation pitch of air outlet grille and support)
571.4
559 (Installation pitch of support and outdoor unit)
4-6×8 hole
49.7
17.8
24
20×24 (=480)
517.7
32°
A part to change air direction from outdoor unit.
Can also be used to prevent short cycles.
Photo
Specications
PUZ-ZM60VHA
PUZ-ZM71VHA PUHZ-ZRP60,71VHA2
PU-P71,100VHAR3
PU-P71,100YHAR3
only 1 piece required
PUHZ-SHW112VHA
PUHZ-SHW112,140YHA
PU-P125,140YHAR6
2 pieces required
Air Outlet Guide
PAC-SG59SG-E
Descriptions
Applicable Models
Dimensions Unit: mm
Air outlet grille: PP resin
Ivory (3.0Y 7.8/1.1)
Air outlet direction
Washer faced screw (M5x35) x 4 (Iron
wire (SWCH18A)/Zinc nickel plated)
Color (Munsell)
Material
Weight 1.2kg
Changeable between up, down or sideways
Accessory name x Qty.
<Material/Surface treatment>
Exterior
(to change air blowing direction)
* Air Guide prevents reverse rotation of outdoor unit fan when it enters low speed rotation mode with fan controller
being operated. It is also used for protection of fan when strong winds, such as a typhoon, wind blowing through tall
buildings, etc., directly strike the air outlet. In addition, installation of this product is necessary when cooling opetation
is to be performed in outdoor tempreture of -5 or lower (down to -15).
Note the followings when installing this guide:
1) Be sure not to use "upward discharge" in a place where snowing is possible. Snow may accumulate in the
guard, which could damage the fan, etc.
2) Attaching this unit will decrease the performance (by 2-3%) and increase noise from outdoor unit (by approx. 1-2 dB).
3) Do not use "upward discharge" when there are any obstacles at the back and on both sides of outdoor unit
(air is taken in from top of unit): This could cause a short cycle.
4) To eliminate the influence of external wind, be sure to install the unit with its back facing to wall.
5) Do not install this unit in a place where wind directly blows to the back of the unit.
CAUTION
[R410A type]
[R32 type]
E-259
OPTIONAL
PARTS
How to Use / How to Install
Air Outlet Guide to change air blowing directions PAC-SG59SG-E
1 
Checking provided parts
Make sure that this package has the following parts as well as the installation sheet:
Support × 2
(For the upper and lower sides)
Support × 2
(For right and left) Attachment screw × 4 Spacer × 4
Attachment screw × 8
PAC-SG58SG-E
(Screw hole×6) PAC-SG58SG-E
(Screw hole×2)
Air Discharge guide × 1
2-fan type outdoor unit
PAC-SG58SG-E(5×10)
PAC-SG59SG-E(5×35)
PAC-SG58SG-E(4×10)
PAC-SG59SG-E
2 
Checking Installation Space
3 
Installation Complete Diagrams
4 
Installation Method
Setting blow-off direction
Upward Downward Sideways (to left or right)
(In the following diagrams, dimensions in parentheses are for 2 fan type models.
Dimensions not in parentheses are common for all series models. Unit: mm)
Secure the necessary surrounding space shown below and select a place with less obstacles, to prevent a short cycle.
1) Surrounding space needed when installing one unit
Do not use "upward discharge" in cases of figures (3) and (5) below.
(1) Obstacle at front
(open at back, sides and top)
(1) Obstacle at front
(open at back, sides and top) (2) Obstacles at back and front
(open at sides and top) (4) Installing units, one in each row
(5) Installing multiple units in multiple rows
(3) Obstacles at back and top
(open at front and sides)
(2) Obstacles at back and front
(open at sides and top) (3) Obstacles at back and top
(open at front and sides)
(4) Obstacles at back, and sides
(open at front and top) (5) Obstacles at back, sides
and top (open at front)
2) Surrounding space needed when installing multiple units
When installing units horizontally in a series, leave at least 350 mm space between units for RP2, 50 type or lower
models, and at least 10 mm for RP2.5, 60 type or higher models.
Do not use "upward discharge" in case of figure (3) below.
Keep at least 1000 (2000) when using
discharge guide in directions other than
"upward discharge".
Keep at least 2000 (3000) when using
discharge guide in directions other
than "upward discharge".
For RP1.6, 2, 35, 50
1) Fix the two supports (2) and two supports (3), using four screws (5) to make a frame.
2) Attach the assembled supports to the outdoor unit using four screws (5), and then attach blowout guide (1)
to the support (2), using four screws (4).
Four blowout directions can be selected: Check the orientation of blowout vane, and attach the blowout guide in the direction
that matches the situation at local site.
For (R)P2.5 - 6, 60 - 140: (Two sets of support and blowout guide are necessary for two-fan type models.)
1) Remove the 4 screws that hold the existing fan guard.
2) Fit the 4 spacers into the hole in fan guard, and then use the 4 screws to install the provided blowout guide to the
outdoor unit above the existing fan guard.
 ・The four blowout directions can be selected: Check the orientation of blowout vane, and install the blowout guide in the
direction that matches the circumstance at local site.
discharge
500 or more
500 or more
150
100 or more
1000
300
500 or less
200 or more
1000 or more
200 or more
300
100 or more
200
200
100 or more
RP1.6, 2, 35, 50
350 or more
500 or less
300 or more
500
150 or more
250250
150 or more
RP1.6, 2, 35, 50
350 or more
1000 or more
1500
1000 or more
1000 or more
1500
500
300 or more
300 or more
500
300 or less
1000 or more
1500
1000 or more
1500
1000 or more
1500
Limit of 3 units can be installed horizontally
in series. When installing a larger number
of units, maintain the space between units
shown above.
1000 or more
1000 or more
300 or more
500
1500
1500
600
400 or more
100 or more
500 or more
1000
1000
150
600
500 or more
400 or more
Models RP2.5, 3, 60, 71Models RP1.6, 2, 35, 50
188
Models RP46,100140
86 64
RP1.6, 2, 35, 50
Discharge vane
Air Discharge guide
14
<(R)P2.5 - 6, 60 - 140
Air Discharge guide
fanguard
  • Page 1 1
  • Page 2 2

Mitsubishi Electric PAC-SG59SG-E Installation guide

Category
Split-system air conditioners
Type
Installation guide

Mitsubishi Electric PAC-SG59SG-E is an air outlet guide designed to change the air blowing direction of compatible outdoor units. It can be used to prevent short cycles and is especially useful in areas where strong winds or obstacles may disrupt airflow. The guide can be installed in four different directions: upward, downward, or to the left or right. It is compatible with a range of Mitsubishi Electric outdoor units, including the PUHZ-ZRP60,71VHA2, PUZ-ZM60VHA, PU-P71,100VHAR3, PUHZ-SHW112VHA, and PU-P125,140YHAR6.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI